Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy

Similar documents
Component specific particle characterisation of the active components in a pharmaceutical topical formulations

Discriminating between polymorphs of acetaminophen using Morphologically-Directed Raman Spectroscopy (MDRS)

Use of DLS/Raman to study the thermal unfolding process of lysozyme

Understanding the colloidal stability of protein therapeutics using dynamic light scattering

Overcoming and quantifying Wall Slip in measurements made on a rotational rheometer

GPC/SEC Analysis of Polymer Degradation

Optimization of PLA/PLGA molecular weight and structure to suit final application requirements

The power of multi-detector SEC in the analysis of antibodies

Determining cure profile and post-cure shrinkage of photopolymers using UV accessory on a rotational rheometer

Differentiation of polymer branching and composition using the Mark Houwink plot

Nanobubble Applications and Characterization by Nanoparticle Tracking Analysis

Understanding the conformational stability of protein therapeutics using Raman spectroscopy

GPC/SEC Analysis of Polymer Solutions Used in Inkjet Printing

10 REASONS THAT THE ZETASIZER NANO IS CHOSEN FOR SCIENTIFIC SUCCESS

How to use GPC/SEC for compositional analysis

Introduction to the calculators in the Zetasizer software

Using rheology to study the hardness and spreadability of butter

Studying the Effect of Steric Layer Thickness on Emulsion Stability

Evaluating the rheological properties of hyaluronic acid hydrogels for dermal filler applications

Characterization of Single Wall Carbon Nanotubes (SWNTs) by combining Dynamic Light Scattering and Raman Spectroscopy

Executive Summary. Introduction WHITEPAPER

How switching mobile phases can improve your OMNISEC results

Laser diffraction and automated imaging: complementary techniques for nasal spray development

Using the Zetasizer Nano to optimize formulation stability

DEVELOPING A BIOFORMULATION STABILITY PROFILE

Application of Micro-Flow Imaging (MFI TM ) to The Analysis of Particles in Parenteral Fluids. October 2006 Ottawa, Canada

Measuring the rheology of thermoplastic polymer melts

Introducing the Morphologi G3 ID The future of particle characterization

Measurements of protein electrophoretic mobility using the Zetasizer Nano ZSP

next generation Welcome to the Dispersion options Smarter particle sizing Your sample, expertly processed and prepared Particle size

Morphologically directed chemical identification Coupling particle characterization by morphological imaging with Raman spectroscopy

REVERSE ENGINEERING PHARMACEUTICAL FORMULATION USING THE MORPHOLOGI G3-ID.

MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

SEE WHAT S REALLY IN YOUR FORMULATION WITH BACKGROUNDED MEMBRANE IMAGING

ZS90. The ultimate in desktop particle characterization. Particle size. Zeta potential. Molecular weight

The ultimate in desktop particle characterization

Inform is a series of white papers designed to provide advice on material characterization issues. Mie theory The rst 100 years

Zeta potential - An introduction in 30 minutes

MORPHOLOGI 4 RANGE. Automated imaging for advanced particle characterization

The Diffusion Barrier Technique, Practical Aspects and Data interpretation

MEASURING PROTEIN AGGREGATION WITH THE VISCOTEK SEC-MALS 20

The ultimate in desktop particle characterization

Sample measurements to demonstrate Zetasizer specifications (Zetasizer Nano, Zetasizer APS, Zetasizer μv)

KINEXUS DSR SERIES REDEFINING RHEOMETER CAPABILITIES FOR ASPHALT TESTING

Measuring the rheology of polymer solutions

Gold Nanoparticle Applications and Characterization by Nanoparticle Tracking Analysis

A basic guide to particle characterization

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR

ORTHOGONAL PARTICLE CHARACTERIZATION TECHNIQUES FOR BIO-APPLICATIONS: AN INTRODUCTION TO DLS (DYNAMIC LIGHT SCATTERING), NTA (NANOPARTICLE

Flow Microscopy: Dynamic Image Analysis for Particle Counting

Bohlin. Rheological instruments backed with rheological experience. Rheological properties

Standardization of Optical Particle Counters

KINEXUS SERIES REDEFINING RHEOMETER CAPABILITIES

The Ultimate Guide to Dynamic Imaging Particle Analysis for Protein Therapeutics:

Visualize and Measure Nanoparticle Size and Concentration

Agilent Cary 630 FTIR sample interfaces combining high performance and versatility

KINEXUS SERIES REDEFINING RHEOMETER CAPABILITIES

Introduction to Fourier Transform Infrared Spectroscopy

Micro-Flow Imaging: Flow Microscopy Applied to Sub-visible Particulate Analysis in Protein Formulations

Supporting information

Holographic Characterization of Protein Aggregates

Electrophoretic Light Scattering Overview

Highly automated protein formulation development: a case study

Experimental details. General

Analytical methods to characterize aggregates and subvisible particles

Verification of Pharmaceutical Raw Materials Using the Spectrum Two N FT-NIR Spectrometer

MASTERSIZER 3000 SMARTER PARTICLE SIZING

A Basic Guide to INFORM WHITE PAPER. Abstract:

ISO INTERNATIONAL STANDARD

Method Development. Creating the Perfect Standard Operating Procedure (SOP) 2007 HORIBA, Ltd. All rights reserved.

Method validation for laser diffraction measurements

Confirmation of Coal Quality Using the Agilent ExoScan 4100 Handheld FTIR Spectrometer

Analysis of Subvisible Particles. Linda O. Narhi Formulation and Analytical Resources, R&D Amgen, Inc.

Snowy Range Instruments

Positive and Nondestructive Identification of Acrylic-Based Coatings

ZETASIZER NANO Series PERFORMANCE, SIMPLICITY, VERSATILITY

429 LIGHT DIFFRACTION MEASUREMENT OF PARTICLE SIZE

Correlative Raman Imaging of Polymeric Materials

MicroCell User manual

Malvern Macromolecular Solutions. Innovative Solutions in Material Characterization

Introduction to Fourier Transform Infrared Spectroscopy

SUPPORTING INFORMATION. A New Approach for the Surface Enhanced Resonance Raman Scattering (SERRS)

Biophysical characterization of SMALPs and nanodiscs

Exploiting the Interaction of Pyranine-3 with Poly(L-Lysine) to Mediate Nanoparticle Assembly: Fabrication of Dynamic ph-responsive Nanocontainers

YOUR PARTNER IN PARTICLE CHARACTERIZATION

Physicochemical Characterization of Binary Ionic Polymer Blends: Polyvinyl Acetate Phthalate and Eudragit E PO

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Application Note 12: Fully Automated Compound Screening and Verification Using Spinsolve and MestReNova

Supplementary Information

Pulsar. Delivering NMR to your benchtop

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Lorentz Contact Resonance for viscoelastic measurements of polymer blends

Testing for particles in injectable products

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

RamanStation 400: a Versatile Platform for SERS Analysis

Holographic Characterization of Agglomerates in CMP Slurries

Particle Size and Shape Analysis in PHARMACEUTICAL INDUSTRY.

The solution for all of your

ISO INTERNATIONAL STANDARD

Transcription:

Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy Morphologi G3-ID CHEMICAL IDENTIFICATION PARTICLE SHAPE PARTICLE SIZE PROTEIN AGGREGATION PROTEIN STABILITY Introduction Optical microscopy has long been used to characterize particulates present in biotherapeutic formulations, providing their size, shape, and transparency characteristics, which can then be used to group particulates into distinct classes (i.e. aggregates, silicone oil, sundry contaminants). However, the ability of a microscope to provide explicit identification is limited to the two-dimensional images it collects. The addition of Raman spectroscopy to an automated microscopy system provides a robust primary identification method for the verification of particle chemistry, and together the techniques offer the potential to enumerate, characterize, and identify particulates in native formulations, as well as those immobilized on a filter substrate. This range of capabilities directly addresses FDA quality requirements for drugs administered by injection, in terms of particulate count per unit volume. These regulations are put into practice through USP <788> 1, which calls for enumeration of particulates in two size categories: larger than 10 μm and larger than 25 μm. The more recent release of USP <787> 2 (and <1787>) has extended recommendations to include sizes below 10 μm. This lower size range has drawn considerable attention from the FDA due to concerns about immunogenic response related to proteinaceous aggregates 3, reduced product efficacy, and general safety. Formulation stability can be affected by many factors that lead to the formation of aggregated material 4,5. The Morphologi G3-ID, a hybrid optical microscope-raman spectrometer from Malvern Instruments, provides the imaging power of a high-resolution optical microscope with the chemical identification capabilities of a benchtop Raman spectrometer, and is completely automatable. This application note explores the use of the Morphologi G3-ID for Morphologically-Directed Raman spectroscopy (MDRS) to identify and analyze contaminants including protein aggregates Malvern Instruments Worldwide Sales and service centres in over 65 countries www.malvern.com/contact 2015 Malvern Instruments Limited

present in a stressed sample of lysozyme, and to compare particles held in suspension within a thin path wet cell with those collected on a filter membrane. Materials and Methods A Morphologi G3-ID from Malvern Instruments was used to locate particulates for morphological characterization (size, shape, and transparency), and identify the species chemically using Raman spectroscopy. The Morphologi G3-ID was run with a magnification of 10x, providing an effective lower size limit of 2 μm for particle count. The practical upper size limit at this magnification is around 200 μm, although this can be extended significantly with the included particle stitching routine, which is capable of reassembling the images of particulates that span more than one field of view. Raman spectra were collected using a 3 μm spot at 50x magnification of 785 nm excitation (~20 mw) from 150 cm -1 to 1850 cm -1 at 6 cm -1 resolution. Two separate 100 mg/ml, ph 7.1 solutions of lysozyme were stressed to produce aggregates: one was used for the filter-based analysis and the other for the suspension-phase analysis. Membrane Filter One of the lysozyme preparations was stirred rapidly at room temperature for 16 hours. Aliquots (1 ml) of this aggregated suspension, spiked with a small amount of polystyrene latex spheres as a reference species, were vacuum filtered using a 47 mm cellulose-based Millipore GSWP filter. The filter was taped to a glass slide and allowed to dry before examination. A circular scan area of 15 mm radius was scanned at 10x magnification in order to characterize particulates and record their locations. The particulates were then divided into groups according to their size and morphology, and a subset of each group was chosen for Raman spectral analysis. Suspended Sample The second lysozyme preparation was stirred at 45 o C for four hours and then analyzed in suspension-phase. An aliquot (55 μl) of suspension was delivered to a proprietary thin-path wet cell (25 μm path length) with quartz windows. The cell was allowed to reach thermal equilibrium for 15 minutes before examination. A 20 mm radius scan area was investigated, corresponding to 31.4 μl in volume. 2 Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy

Results The size groups defined for particle counting included 2 μm to 10 μm (small), 10 μm to 25 μm (medium), and greater than 25 μm (large), with the addition of a specific group for the 40 μm polystyrene latex spheres. A selection of images from each group of particles detected on the membrane filter sample is shown in Figure 1. Figure 1: Representative particle images from each size band defined for the lysozyme sample on a membrane filter. Note that the scale is not the same for each group. The polystyrene particles were bright white in color due to the top-light (episcopic) illumination geometry used to collect data. Particles from the aggregate groups appeared darker and had a variety of shape characteristics. The final count data is shown in Figure 2. Figure 2: Particle counts collected for a mixed sample of lysozyme aggregates and 40 µm polystyrene latex on a membrane filter. Note the logarithmic X-axis The results displayed in Figure 2 show increasing particle counts as particle size decreases, and that similar numbers of large aggregate-type particles and 3 Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy

polystyrene particles were detected in the experiment. The overall particle count was much higher than would be expected for a commercial sample that has not been stressed, but serves to illustrate the counting and characterization capabilities of the Morphologi G3-ID. Raman spectra were collected for 30 particles from the group labeled polystyrene. Of these, 29 were identified as polystyrene latex, and one gave a proteinaceous spectrum. After examination, there appeared to be a lysozyme aggregate in proximity to the polystyrene particle that gave rise to the recorded spectrum. Additionally, 14 spectra were collected from the large (> 25 um) group. All spectra were collected for 30 seconds integration time at the available low power settings (~5 mw). Of the 14 additional spectra collected, 13 were identified as lysozyme aggregates, and one gave rise to a broad fluorescence spectrum and was taken to be rubber (inset, green spectrum). Example spectra of the background filter, a proteinaceous particle, a latex sphere and a rubber particle are shown in Figure 3. The spectra collected for the sample illustrate the ability of the Morphologi G3-ID to identify subvisible particulates on a membrane filter, even when they are weakscattering materials such as protein aggregates. Figure 3: Representative spectra collected from the filtered lysozyme sample: membrane filter background (black), lysozyme aggregate (blue), polystyrene sphere (red). The inset (green) shows the spectrum of a rubber particle that was found in the sample A selection of images from each group of particles examined in the thinpath wet cell are shown in Figure 4. Observation of these particle images 4 Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy

revealed a distinctly different particulate morphology than that recorded for the samples captured on the membrane filter. The filtered aggregates appeared to be crystalline, while those observed for the suspended samples appeared more diffuse. In fact, it could be argued that the particulates in the lysozyme suspension seemed to be a series of smaller aggregates collected together in a larger body (Figure 5). This result suggests that changing the stress conditions (sample preparation and/or collection) may have altered the aggregation mechanism for lysozyme. Figure 4: Representative particle images from each of the size bands defined for the lysozyme sample in suspension. Note that the scale is not the same for each group. Figure 5: Image of the largest recorded aggregate particle from the filtered sample (left) and from the suspended sample (right) The morphological results for the suspended sample were grouped according to size in the same fashion as for the filtered sample: size bins covering 2 μm -10 μm 5 Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy

(small), 10 μm - 25 μm (medium), and 25 μm+ (large), with the results summarized in Figure 6. Particle counts were considerably higher for the suspended sample than for the filtered sample, except in the case of the largest aggregates. This result, together with the observed morphology of the two sample types, does suggest that the aggregation mechanism differs between the samples. Particle spectra were collected for a small series of the large aggregates at 2 minutes integration time. 25 particles were examined, with three identified as cellulose and the other 22 identified as proteinaceous. Example spectra are shown in Figure 7. 6 Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy

Figure 7: Representative spectra collected from the suspended lysozyme sample: Cellulose particle (black), lysozyme aggregates (blue and red). Regions associated with common Raman features for proteinaceous materials are highlighted in green Although the spectra are noisy, identification of the species was accomplished using approximate band positions. For example, the red and blue spectra were identified as proteinaceous by examination of the 760 cm -1 tryptophan band, the 1000 cm -1 phenylalanine band, the 1250 cm -1 Amide III band, 1400 cm -1 asymmetric CH 2 stretch band, and the 1650 cm -1 Amide I band. The spectrum in black, that of a cellulose particle, shows the characteristic ~1100 cm -1 doublet and ~1400 cm -1 triplet of cellulose. Thus, even for microspectroscopy on 50 μm particles in suspension, the Morphologi G3-ID can provide spectra useful for identification of particulates. It should be noted that no conclusions have been drawn regarding detailed structural information about the proteinaceous particles seen either on the filter or in suspension,e.g.,α-helix,β-sheet, or random coil conformations. Data collection times could be increased to improve the signal-to-noise ratio of the spectra, which may provide more detail. 7 Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy

Discussion Particulate enumeration and characterization are of particular interest in the field of biotherapeutic formulation. USP <788> calls for the assessment of particles in the 10 μm to 25 μm and also the 25 μm and larger size ranges. However, there is new industry interest in accessing the sub-10 μm size range, in line with expectations for new FDA suggestions. Optical microscopes, such as the Morphologi G3-ID, are well-suited to operation in this size range, and offer the promise to provide high-resolution images and 100 percent particle counting for the sample volume delivered. Raman spectroscopy extends these capabilities, allowing for chemical identification of particles. This directly addresses the requirements outlined in USP <787> for enumeration and morphological characterization, with the added strength of direct explicit chemical identification of subvisible (2 μm -100 μm) particles. Raman spectroscopy is well known as a technique with high chemical specificity, and is capable of discriminating between chemically-similar materials due to the unique vibrational structure of discrete chemical entities. Typically, unknown materials are identified through interrogation of a library of reference materials that can be updated to include user-specific compounds. Conclusions The combination of automated microscopy and Raman spectroscopy was used successfully to detect and identify particulate species from lysozyme samples both held in suspension within a thin-path wet cell and also after filtration through a membrane. This technology combination offers users the flexibility to measure samples in their native state, or to isolate particulates on a substrate suitable for further analysis methods. Particle morphology may be used to distinguish between extrinsic contaminants and aggregates, as well as between different types of aggregates. Additionally, this technique offers the promise to study structural differences between aggregate species through changes in their Raman spectra. References 1. United States Pharmacopeia, <788>: Particulate Matter in Injections 2. United States Pharmacopeia, <787>: Subvisible Particulate Matter in Therapeutic Protein Injections 3. A.S. Rosenberg, Effect of protein aggregates: an immunologic perspective. The AAPS Journal 8, E501-E507 (2006) 8 Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy

4. H.C. Mahler, W. Friess, U. Grauschopf, and S. Kiese, Protein Aggregation: Pathways, induction Factors and Analysis. Journal of Pharmaceutical Sciences 98 (9), 2909-2934 (2009) 5. S. Amin, G.V. Barnett, J.A. Pathak, C.J. Roberts, and P.S. Sarangapani, Protein aggregation, particle formation, characterization & rheology. Current Opinion in Colloid & Interface Science (2014) 9 Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy

Malvern Instruments Limited Grovewood Road, Malvern, Worcestershire, UK. WR14 1XZ Tel: +44 1684 892456 Fax: +44 1684 892789 www.malvern.com Malvern Instruments is part of Spectris plc, the Precision Instrumentation and Controls Company. Spectris and the Spectris logo are Trade Marks of Spectris plc. All information supplied within is correct at time of publication. Malvern Instruments pursues a policy of continual improvement due to technical development. We therefore reserve the right to deviate from information, descriptions, and specifications in this publication without notice. Malvern Instruments shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Malvern Instruments owns the following registered trademarks: Bohlin, FIPA, Insitec, ISYS, Kinexus, Malvern, Malvern 'Hills' logo, Mastersizer, MicroCal, Morphologi, Rosand, 'SEC-MALS', Viscosizer, Viscotek, Viscogel and Zetasizer. 2015 Malvern Instruments Limited AN150722G3-IDProteinSuspensionAnalysis