Mass Analyzers. Ion Trap, FTICR, Orbitrap. CU- Boulder CHEM 5181: Mass Spectrometry & Chromatography. Prof. Jose-Luis Jimenez

Similar documents
CEE 772 Lecture #27 12/10/2014. CEE 772: Instrumental Methods in Environmental Analysis

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

CEE 772: Instrumental Methods in Environmental Analysis

Types of Analyzers: Quadrupole: mass filter -part1

MASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps

Tendenze nell innovazione della strumentazione in spettrometria di massa:

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Mass Spectrometry and Proteomics - Lecture 2 - Matthias Trost Newcastle University

Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR-MS)

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

Week 5: Fourier Tranform-based Mass Analyzers: FT-ICR and Orbitrap

The Aerosol Ion Trap Mass Spectrometer (AIMS): Instrument development and first experimental results

Chemistry Instrumental Analysis Lecture 35. Chem 4631

Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

Mass Spectrometry. What is Mass Spectrometry?

LECTURE-11. Hybrid MS Configurations HANDOUT. As discussed in our previous lecture, mass spectrometry is by far the most versatile

Atomic masses. Atomic masses of elements. Atomic masses of isotopes. Nominal and exact atomic masses. Example: CO, N 2 ja C 2 H 4

This is the total charge on an ion divided by the elementary charge (e).

Introduction to the Q Trap LC/MS/MS System

GRADUATE COURSE IN MASS SPECTROMETRY: LECTURE 2

VIII. QUADRUPOLE ION TRAPS: AN ION TRAPPING INST. A. BASIC DESIGN (REF: JMS, 1997, 32, 351)

Mass Spectrometry in MCAL

Introduction to GC/MS

1. The range of frequencies that a measurement is sensitive to is called the frequency

MS Goals and Applications. MS Goals and Applications

Lecture 8: Mass Spectrometry

Lecture 8: Mass Spectrometry

Ionization Techniques Part IV

Harris: Quantitative Chemical Analysis, Eight Edition

Ion traps. Quadrupole (3D) traps. Linear traps

Analysis of Polar Metabolites using Mass Spectrometry

Mass spectrometry gas phase transfer and instrumentation

Quadrupole Storage Mass Spectrometry

MS Goals and Applications. MS Goals and Applications

Autoresonant Ion Trap Mass Spectrometer The RGA Alternative

CHAPTER D4 ORTHOGONAL TIME OF FLIGHT OPTICS

Chem 550, Spring, 2012 Part I: OVERVIEW OF MASS SPECTROMETRY:

Choosing the metabolomics platform

Selecting and planning for the right mass spectrometer

MS/MS .LQGVRI0606([SHULPHQWV

Mass Spectrometry. Quantitative Mass Spectrometry Chiral Mass Spectrometry

for the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai

Simulation of External Ion Injection, Cooling and Extraction Processes with SIMION 6.0 for the Ion Trap/Reflectron Time-of-flight Mass Spectrometer

Ion trap. 3D Quadrupole Trap. -Mass spectrometer -Ion trap (Quadrupol Ion Storage, Quistor) 18. April

Mass spectrometry of proteins, peptides and other analytes: principles and principal methods. Matt Renfrow January 11, 2008

TANDEM MASS SPECTROSCOPY

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

LC-MS Based Metabolomics

Time-of-Flight Mass Analyzers

Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. MAGLAB Summer School Ryan P. Rodgers

Translational Biomarker Core

1 Mass Analysis. Gene Hart-Smith and Stephen J. Blanksby

Mass Selective Ejection by Axial Resonant Excitation from a Linear Ion Trap

PC 235: Mass Spectrometry and Proteomics

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

FOURIER TRANSFORM MASS SPECTROMETRY

Principles of Quadrupole and Ion Trap Mass Analyzers

BST 226 Statistical Methods for Bioinformatics David M. Rocke. January 22, 2014 BST 226 Statistical Methods for Bioinformatics 1

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

Mass Analysers for LC MS

Mass spectrometry: forming ions, to identifying proteins and their modifications Stephen Barnes, PhD

Practical Quadrupole Theory: Peak Shapes at Various Ion Energies

CHAPTER D3 TOF ION OPTICS

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Mass Spectrometry. Fundamental LC-MS. Mass Analysers

Chemistry 311: Topic 3 - Mass Spectrometry

Powerful Scan Modes of QTRAP System Technology

Accurate, High-Throughput Protein Identification Using the Q TRAP LC/MS/MS System and Pro ID Software

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Ion Sponge: A 3 Dimentional Array of Quadrupole Ion Traps for Trapping and Mass-Selectively Processing Ions in Gas Phase

Mass spectrometry.

Beam Diagnostics Lecture 3. Measuring Complex Accelerator Parameters Uli Raich CERN AB-BI

Università degli Studi di Bari CHIMICA ANALITICA STRUMENTALE

Space Charge Effects in Linear. Quadrupole Ion Traps

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

Performance Evaluation of a Hybrid Linear Ion Trap/Orbitrap Mass Spectrometer

Mass spectrometry: forming ions, to identifying proteins and their modifications Stephen Barnes, PhD

MS Interpretation-1: Introduction + Elemental Composition I

Mass Spectroscopy. Base peak. Molecular Ion peak. The positively charged fragments produced are separated, based on their mass/charge (m/z) ratio. M+.

Dynamics of Ions in an Electrostatic Ion Beam Trap

1) Introduction. 2) Types of Mass Analyzers - Overview. Assigned Reading: Nier mass spectrometry paper Extra Reading:

Mass Spectrometry Course

De Novo Metabolite Chemical Structure Determination. Paul R. West Ph.D. Stemina Biomarker Discovery, Inc.

What is a mass spectrum?

Interface (backside) & Extraction Lens

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

Ionization Methods in Mass Spectrometry at the SCS Mass Spectrometry Laboratory

Mass Spectrometry. Ionizer Mass Analyzer Detector

All of us engaged in science face exciting opportunities

Why Make Rare Isotopes?

ICPMS Doherty Lecture 1

Secondary Ion Mass Spectroscopy (SIMS)

2401 Gas (liquid) Chromatography

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

Secondary Ion Mass Spectrometry (SIMS) Thomas Sky

Magnetic Sector Mass Spectrometer Quadrupole mass spectrometer Quadrupole Ion Traps Orthogonal Sampling Time of Flight Mass Spectrometer Fourier

Trapping in 2-D The Radio Frequency Quadrupole

Quantitative Screening of 46 Illicit Drugs in Urine using Exactive Ultrahigh Resolution and Accurate Mass system

Transcription:

Mass Analyzers Ion Trap, FTICR, Orbitrap CU- Boulder CHEM 5181: Mass Spectrometry & Chromatography Prof. Jose-Luis Jimenez Last Update: Oct. 014 Some slides from Dr. Joel Kimmel (007) MS Interpretation Lectures High Vacuum Sample Inlet Ion Source Mass Analyzer Detector Recorder 1 Business Items Questions or comments? Labview Megan C is done

Review Clicker Q on Quadrupoles To operate a quadrupole in a scanning mode, where individual m/z values are transmitted one after the other (e.g., m/z = 100; 101; 10 ) A. U is held constant, while V is scanned B. V is held constant, while U is scanned C. U is held constant, while V and ω are scanned D. U and V are both changed B. A or B 3 Types of Mass Analyzers Time-of-flight (TOF) Quadrupoles Ion traps Ultrahigh resolution Orbitrap Ion-Cyclotron Resonance (ICR) Sector Magnetic Electric Hybrids & specialized 4

Quadrupole Ion Traps Ring electrode (r) End cap electrodes (z) Fundamental RF: Fixed frequency (1.1 MHz) variable voltage (up to 7 kv) applied to Ring Electrode DC: An optional DC voltage may be applied to the ring electrode, which will affect the stability of ion trajectories Resonance AC: Fixed frequency voltage applied to end caps for resonant ejection or fragmentation Note that ions enter and exit along z axis Pressure (1 mtorr) dampens extra kinetic energy and E of repulsion 5 3D Ion Trap Pictures Hand-held dimensions 6

Ion Motion Inside an Ion Trap From Lambert RF fields induce oscillations in r and z directions A trapped ion is stable along both axes 7 Space Charge Effects Trapping lots of ions in a small volume Ions repel each other Good performance based on ions responding to external E field (as in quad simulation). If the E field from other ions is significant, the performance is distorted Space charge, i.e. E field due to charges in 3D space, not only surfaces of our mass analyzer Also a consideration in design of some ion sources, and other traps Ion energy is dampened by collisions with He neutrals. It would be worse under vacuum. SC limits the total number of ions sensitivity 8

Quadrupole vs Quad. Ion Trap Quadrupole RF fields yield m/z band of stability D Manipulation of trajectory Detect those ions that are selectively transmitted with stable trajectories Continuous analysis Quad. Ion Trap RF fields yield m/z band of stability 3D Manipulation of trajectory Detect those ions that are selectively ejected due to destabilized trajectory Pulsed analysis 9 Stability Diagram for an Ion Trap From Watson a U a V 10

m/z Dependent Stability q z m( r o 8ezV z )( ) o Stability boundary at q z = 0.908 Stability diagrams for m/z = 10, 50, and 100 in V(RF) - U(DC) space. Note that, like quadrupole, broadest range of m/z stability at U=0 Increasing V will destabilize low m/z ions. That is, high m/z stable to higher V. From de Hoffmann Clicker Q: if U = 0, can we eject m/z 100 while keeping m/z 50? (A) Yes (B) No (C) I don t know 11 Like a quadrupole mass spectrometer, ion stability described by variables related to RF and DC components. For most operation, DC component is zero. And stability determined by q z Stability Diagram q z m( r o 8ezV z )( ) o q z depends on mass, charge, dimensions, RF frequency, and RF amplitude (V) Ions trapped with stable trajectory up to q z of 0.908 1

True or False. Just like in a quadrupole, I can select only a given m/z value by adjusting U and V so that ions of that m/z ( ) are just inside the apex the stability diagram. A. Definitely True B. Maybe C. Probably Not D. Definitely False E. I don t know Clicker Question 13 Ion Ejection at the Stability Limit From Hoffmann 14

Clicker Question: Ion Traps In a 3D quadrupole ion trap, ions are detected by: A. Ejecting ions by suddenly stopping the DC voltage (U) B. Ejecting ions by suddenly stopping the RF voltage (V) C. Detecting the image current of the ions on the surfaces of the trap D. Ejecting ions by moving U, V to a region where those ions are unstable E. I don t know 15 Secular Frequency Because of inertia, ions do not oscillate at the fundamental frequency applied to the trap, v Instead, ions oscillate at a secular frequency, f, that is lower than v It is possible to calculate the value of f z based on applied V Along the z axis, f z is proportional to q z (See text..) If an RF voltage at frequency = f z is applied to the end caps, ions with secular frequency f z will come into resonance and the amplitude of its oscillation along z axis will increase If the increase is large enough, the ion will be ejected 16

Resonant Ejection f z is proportional to q z Ion at this q z will oscillate in resonance with f z For fixed fundamental frequency, q z of an ion is adjusted by varying V f z applied to end caps creates a hole in the stability diagram at the q z corresponding to ion oscillation frequency f z Scan of V destabilizes ions of changing m/z Figure from: http://www.abrf.org/abrfnews/1996/september1996/sep96iontrap.html 17 Example: v = 1.1 MHz causes z oscillation with f z = 160 khz Apply v = 160 khz to end caps Energy transferred to ion through resonance causes destabilization along z Resonant Ion Ejection Resonant ejection allows selective detection of ions at q z lower than 0.908 From de Hoffmann 18

Ion Trap Movies (linked on course page) Ions from source are focused along z axis of trap by standard transfer optics Continuous beam is gated into trap. Ionization period is set to maximize signal and minimize space charge effects. Cell is filled with inert gas (e.g., He) at 1 mtorr to dampen kinetic energy of ions and contract trajectories toward center improves resolution 19 Resonant Ejection Enables MS N Forward and reverse scanning of V allows user to isolate single m/z value in trap Isolated ions can be fragmented by collisions with background gas Excite ion with resonance Keep amplitude low enough to avoid ejection The ability to repeat the isolation-andfragmentation cycle allows MS N analysis (Demos) 0

How many of the following are true? Clicker Q (i) At any moment, an ion trap detects those m/z values that are stable (ii) Ion traps typically have ~100% duty cycle when coupled to continuous ion sources (iii) In the scanning mode we discussed, the largest m/z of an ion trap is limited by the minimum RF voltage that can be applied while still inducing stable trajectories (iv) In the scanning mode that we discussed, increasing V yields detection of higher m/z ions (a) 0 (b) 1 (c) (d) 3 (e) 4 1 MS/MS with an Ion Trap From Hoffmann

Linear Ion Trap Similar idea with new geometry: RF-only quad with end electrodes Ions can be trapped for several days From http://heart-c704.uibk.ac.at/research/lintrap/ 3 Picture of two ions in the trap Linear Ion Trap II Animation of the Trapping 4

5 ICR Geometry, Excitation, & Ion Motion From Hoffmann 6

FTICR: Animation http://www.youtube.com/watch?v=a5allm9q-xc 7 FTMS: Time to Frequency Conversion From Lambert No traditional detector (multiplier, MCP) Detection of image currents induced by flying ions, measured over and over and over 8

FTMS Extreme Resolution????????? Clicker: resolution is about: (a) 10 3 (b) 10 6 (c) 10 7 (d) 10 8 (e) Don t know From Watson 9 FT-ICR MS: Sensitivity & nondestructiveness Clicker: mean free path? (a) 10 m (b) 1 km (c) 100 km (d) Can t be determined (e) I don t know From Hoffmann 30

How many of the following are true. Clicker (i) An ion trap requires lower vacuum than an FTICR (ii) Resolution in an ion trap depends critically on the precision of the power supplies used to set the voltage of the ring electrode (iii) Resolution in an ion trap depends critically on the speed of the acquisition electronics (iv) For the scanning mode we discussed, the duty cycle of an ion trap depends on the m/z range recorded (a) 0 (b) 1 (c) (d) 3 (e) 4 31 Perspective: The Orbitrap: a new mass spectrometer. Q. Hu, R.J. Noll, H. Li, A. Makarov, M. Hardman, R. Graham Cooks. J. Mass Spec., 40(4): 430 443, 005. Orbitrap Orbitrap Ion axial motion: ( q / m ) k Electric Field: k r U ( r, z ) z r k R ln C m R m Non destructive detection Destructive detection (mass selective instability) a 4 ( / ) q ( / ) Preliminary Results: Transient New type of Fourier Transform mass analyzer High mass accuracy Small size Non-destructive detection FFT Mass Spectrum m/z q m k See also: A. Makarov, Anal. Chem. 000; and Anal. Chem., 003. Cutaway view of the Orbitrap mass analyzer. Ions are injected into the Orbitrap at the point indicated by the red arrow. The ions are injected with a velocity perpendicular to the long axis of the Orbitrap (the z-axis). Injection at a point displaced from z = 0 gives the ions potential energy in the z-direction. Ion injection at this point on the z- potential is analogous to pulling back a pendulum bob and then releasing it to oscillate. http://www.chem.purdue.edu/iii/orbitrap%0instrument.htm 3

Orbitrap Animations http://www.youtube.com/watch?v=zjagpubnv-y 33 Orbitrap II C-Trap for injection Linear ion trap interface Orbitraps have a high mass accuracy (1- ppm), a high resolving power (up to 00,000) and a high dynamic range (around 5000) http://www.thermo.com/com/cda/resources/resources_detail/1,,00176,00.html 34

+5 m/m = 70,000 Example Orbitrap Data Instrument performance for Bovine Insulin +3 1,147 1,148 1,149 +4 m/m = 40,000 +5 m/m = 45,000 1,911 1,91 1,913 1,914 +3 1,434 1,435 1,436 +4 1,00 1,400 1,600 1,800 m/z http://www.chem.purdue.edu/iii/orbitrap%0instrument.htm 35 Clicker Question: High-Resolution MS The use of ultrahigh resolution MS: A. Eliminates the need for chromatographic separation B. Reduces the need for chromatographic separation C. Does not reduce the need for chromatography D. I don t know E. All of the above 36

As Impressive as this is, even ultrahigh resolution often it is not enough on its own! Figure 4: Trend pattern histogram for mathematical possible number of molecular formulae (C, H, N, S, O and P) for the mass range 00 u-300 u. A step size of 0.01 u was taken for counting the number of formulae. Metabolomic database annotations via query of elemental compositions: Mass accuracy is insufficient even at less than 1 ppm. Tobias Kind and Oliver Fiehn. BMC Bioinformatics 006, 7:34, doi:10.1186/1471-105-7-34. http://www.biomedcentral.com/1471-105/7/34 37 Hybrid Instruments From Hoffmann Very common, combine the advantages of various analyzers 38

Progress of MS Analysis From James (Ed.). Proteome Research: Mass Spectrometry. Springer, 000. (QP551.P7558 001 at CU Libraries) 39 Comparison of Mass Analyzers I From Lambert 40

Comparison of Mass Analyzers II G. Siuzdak. Mass Spectrometry for Biotechnology. Academic Press, 1996. QP519.9.M3 S58 1996 at CU Libraries. 41 Comparison of Mass Analyzers III C. Dass. Principles and Practice of Biological Mass Spectrometry. Wiley Interscience, New York, 001. QP519.9.M3 D33 001 at CU Libraries. 4