TRIAXIAL TESTS ON UNDISTURBED SAMPLES RETRIEVED FROM FAILED SLOPES DUE TO 2004 NIIGATA-KEN CHUETSU EARTHQUAKE

Similar documents
POSSIBILITY OF UNDRAINED FLOW IN SUCTION-DEVELOPED UNSATURATED SANDY SOILS IN TRIAXIAL TESTS

1.8 Unconfined Compression Test

the tests under simple shear condition (TSS), where the radial and circumferential strain increments were kept to be zero ( r = =0). In order to obtai

Soil strength. the strength depends on the applied stress. water pressures are required

UNDRAINED FLOW CHARACTERISTICS OF PARTIALLY SATURATED SANDY SOILS IN TRIAXIAL TESTS

THE CONSTRUCTION OF EARTHQUAKE DAMAGE DATA ARCHIVES FOR EARTHQUAKE DISASTER MITIGATION

Cyclic Triaxial Behavior of an Unsaturated Silty Soil Subjected to Suction Changes

LIQUEFACTION STRENGTH OF COARSE WELL GRADED FILL UNDER TORSIONAL SIMPLE SHEAR

Theory of Shear Strength

SHEAR STRENGTH OF SOIL

Chapter 5 Shear Strength of Soil

SOIL SHEAR STRENGTH. Prepared by: Dr. Hetty Muhammad Azril Fauziah Kassim Norafida

Effect of Frozen-thawed Procedures on Shear Strength and Shear Wave Velocity of Sands

Theory of Shear Strength

SHEAR STRENGTH OF SOIL UNCONFINED COMPRESSION TEST

Extremely large post-liquefaction deformations of saturated sand under cyclic torsional shear loading

walls, it was attempted to reduce the friction, while the friction angle mobilized at the interface in the vertical direction was about degrees under

Chapter (12) Instructor : Dr. Jehad Hamad

Effect of cyclic loading on shear modulus of peat

SHEAR STRENGTH OF SOIL

10th Asian Regional Conference of IAEG (2015)

Stress and Strains in Soil and Rock. Hsin-yu Shan Dept. of Civil Engineering National Chiao Tung University

Following are the results of four drained direct shear tests on an overconsolidated clay: Diameter of specimen 50 mm Height of specimen 25 mm

Laboratory Testing Total & Effective Stress Analysis

LOCAL DEFORMATION PROPERTIES OF SEGREGATED SAND SPECIMEN IN HOLLOW CYLINDRICAL TORSIONAL SHEAR TESTS

Prof. B V S Viswanadham, Department of Civil Engineering, IIT Bombay

Experimental Study on the Rate Effect on the Shear Strength

On the Role of ph in the Cyclic Behavior of Fine-Grained Soils

(Refer Slide Time: 02:18)

Triaxial Shear Test. o The most reliable method now available for determination of shear strength parameters.

Reduction of static and dynamic shear strength due to the weathering of mudstones

Finite Deformation Analysis of Dynamic Behavior of Embankment on Liquefiable Sand Deposit Considering Pore Water Flow and Migration

The Shear Strength of Clayey Soils from Reactivated Landslides

POST-CYCLIC RECOMPRESSION CHARACTERISTICS OF A CLAY SUBJECTED TO UNDRAINED UNI-DIRECTIONAL AND MULTI-DIRECTIONAL CYCLIC SHEARS

SHEAR MODULUS AND DAMPING RATIO OF SANDS AT MEDIUM TO LARGE SHEAR STRAINS WITH CYCLIC SIMPLE SHEAR TESTS

Landslide FE Stability Analysis

Estimation of Multi-Directional Cyclic Shear-Induced Pore Water Pressure on Clays with a Wide Range of Plasticity Indices

NUMERICAL ANALYSIS OF DAMAGE OF RIVER EMBANKMENT ON SOFT SOIL DEPOSIT DUE TO EARTHQUAKES WITH LONG DURATION TIME

8.1. What is meant by the shear strength of soils? Solution 8.1 Shear strength of a soil is its internal resistance to shearing stresses.

Cyclic Behavior of Sand and Cyclic Triaxial Tests. Hsin-yu Shan Dept. of Civil Engineering National Chiao Tung University

CHARACTERISTICS OF LIQUEFIED SILTY SANDS FROM MEIZOSEISMAL REGION OF SHILLONG PLATEAU, ASSAM AND BHUJ IN INDIA

Cite this paper as follows:

D1. A normally consolidated clay has the following void ratio e versus effective stress σ relationship obtained in an oedometer test.

Resonant Column and Torsional Cyclic Shear System

Residual Deformation Analyses to Demonstrate the Effect of Thin Steel Sheet Piles on Liquefaction-Induced Penetration Settlement of Wooden Houses

EFFECT OF SILT CONTENT ON THE UNDRAINED ANISOTROPIC BEHAVIOUR OF SAND IN CYCLIC LOADING

1.5 STRESS-PATH METHOD OF SETTLEMENT CALCULATION 1.5 STRESS-PATH METHOD OF SETTLEMENT CALCULATION

Soil Properties - II

SMALL STRAIN SHEAR STIFFNESS OF TOYOURA SAND OBTAINED FROM VARIOUS WAVE MEASUREMENT TECHNIQUES

CHARACTERISATION OF SLOPE FAILURES DURING THE 2004 NIIGATA-KEN CHUETSU AND THE 2007 NIIGATA-KEN CHUETSU-OKI EARTHQUAKE

Ch 4a Stress, Strain and Shearing

SOME OBSERVATIONS RELATED TO LIQUEFACTION SUSCEPTIBILITY OF SILTY SOILS

Case Study - Undisturbed Sampling, Cyclic Testing and Numerical Modelling of a Low Plasticity Silt

AMPLIFICATION OF GROUND STRAIN IN IRREGULAR SURFACE LAYERS DURING STRONG GROUND MOTION

Numerical model comparison on deformation behavior of a TSF embankment subjected to earthquake loading

Module 12:Insitu Ground Reinforcement and liquefaction of soils Lecture 38:Definition and mechanism of Liquefaction. The Lecture Contains:

Shear Strength of Soils

Comparison of the post-liquefaction behaviour of hard-grained and crushable pumice sands

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 1, No 4, 2011

RELIQUEFACTION POTENTIAL OF CEMENT-TREATED SANDY SOILS

Seismic Stability of Tailings Dams, an Overview

CYCLIC LIQUEFACTION POTENTIAL OF LACUS- TRINE CARBONATE SILT FROM JULIAN ALPS

EFFECTS OF SAMPLING DISTURBANCE ON DYNAMIC PROPERTIES OF SATURATED SANDS

Excess Pore Pressure Generation in Sand Under Non-Uniform Strain Amplitudes

SIMPLIFIED METHOD IN EVALUATING LIQUEFACTION OCCURRENCE AGAINST HUGE OCEAN TRENCH EARTHQUAKE

Pre-failure Deformability of Geomaterials. Hsin-yu Shan Dept. of Civil Engineering National Chiao Tung University

Urgent Report of the Landslide Disasters by the Mid Niigata Prefecture Earthquake in 2004, Japan

6 th International Conference on Earthquake Geotechnical Engineering 1-4 November 2015 Christchurch, New Zealand

Study of the liquefaction phenomenon due to an earthquake: case study of Urayasu city

Mudflow type Failure of Volcanic soil during the Earthquake

Welcome back. So, in the last lecture we were seeing or we were discussing about the CU test. (Refer Slide Time: 00:22)

EVALUATION OF STRENGTH OF SOILS AGAINST LIQUEFACTION USING PIEZO DRIVE CONE

With high enough plate forces in opposite directions Bolts. How do these fail? Each pin has sheared into two pieces.

A COMPARISON BETWEEN IN SITU AND LABORATORY MEASUREMENTS OF PORE WATER PRESSURE GENERATION

POST CYCLIC SHEAR STRENGTH OF FINE GRAINED SOILS IN ADAPAZARI TURKEY DURING 1999 KOCAELI EARTHQUAKE

Landslide Stability Analysis Utilizing Shear Strength of Slip Surface Soil: Asato and Tyunjun Landslides, Okinawa, Japan

Y. Shioi 1, Y. Hashizume 2 and H. Fukada 3

MEDAT-2: Some Geotechnical Opportunities. Site Characterization -- Opportunities. Down-hole CPT & vane (Fugro)

EFFECTIVE STRESS ANALYSES OF TWO SITES WITH DIFFERENT EXTENT OF LIQUEFACTION DURING EAST JAPAN EARTHQUAKE

3-D Numerical simulation of shake-table tests on piles subjected to lateral spreading

Formation and Propagation of Localized Deformation in marine clays under plane strain condition

Soil and Rock Strength. Chapter 8 Shear Strength. Steel Strength. Concrete Strength. Dr. Talat Bader May Steel. Concrete.

Numerical analysis of effect of mitigation measures on seismic performance of a liquefiable tailings dam foundation

A STUDY ON DAMAGE TO STEEL PIPE PILE FOUNDATION ON RECLAIMED LAND DURING HYOGO-KEN-NANBU EARTHQUAKE

EFFECTS OF OVERCONSOLIDATION ON LIQUEFACTION STRENGTH OF SANDY SOIL SAMPLES

Evaluation of undrained response from drained triaxial shear tests: DEM simulations and Experiments

Drained Against Undrained Behaviour of Sand

Mitigation of Earthquake-Induced Catastrophic Landslide Hazard on Gentle Slopes by Surface Loading

EARTHQUAKE-INDUCED SETTLEMENT AS A RESULT OF DENSIFICATION, MEASURED IN LABORATORY TESTS

EFFECT OF LOADING FREQUENCY ON CYCLIC BEHAVIOUR OF SOILS

APPENDIX J. Dynamic Response Analysis

Numerical Study of Relationship Between Landslide Geometry and Run-out Distance of Landslide Mass

Experimental Study on The Seismic Assessment of Pile Foundation in Volcanic Ash Ground

Liquefaction Resistance and Internal Erosion Potential of Non-Plastic Silty Sand

New Criterion For The Liquefaction Resistance Under Strain-Controlled Multi-Directional Cyclic Shear

Transactions on the Built Environment vol 3, 1993 WIT Press, ISSN

Effective stress analysis of pile foundations in liquefiable soil

Soil Behaviour in Earthquake Geotechnics

3 DYNAMIC SOIL PROPERTIES

CONTINUOUS OBSERVATION OF MICROTREMOR AT A GEO- DISASTER SITE BEFORE AND AFTER THE 2011 OFF THE PACIFIC COAST OF TOHOKU EARTHQUAKE

Transcription:

Institute of Industrial Science, University of Tokyo Bulletin of ERS, No. 41 TRIAXIAL TESTS ON UNDISTURBED SAMPLES RETRIEVED FROM FAILED SLOPES DUE TO 24 NIIGATA-KEN CHUETSU EARTHQUAKE Jianliang DENG 1, Yukika TSUTSUMI 2, Hiroshi KAMEYA 3, Takeshi SATO 4 and Junichi KOSEKI 5 ABSTRACT: Triaxial compression tests were performed on undisturbed specimens to reveal the mechanism of slope failure in the 24 Niigata-ken Chuetsu Earthquake. The specimens were retrieved from two failed slopes which were located at Yokowatashi and Higashi-Takezawa, respectively. Drained monotonic loading test results showed that the mobilized friction angle is significantly larger than the inclination angle of slope in both cases. Undrained cyclic loading test results showed that full liquefaction did not occur. For the specimens retrieved from Yokowatashi site, the characteristics of shear band showed several different patterns which are likely to be relevant to material type, degree of weathering and existence of cavities in the sandy layer. Key Words: Triaxial compression test, thin weak layer, slope failure, earthquake INTRODUCTION The Niigata-ken Chuetsu Earthquake, with a main shock of Mj=6.8, triggered extensive slope failures in Mid Niigata Prefecture, Japan on October 23 in 24. After the mainshock, many large aftershocks repeatedly struck this area within about two months. According to aerial photo interpretation (MLIT, 25), 3,791 slopes failed with total breakdown volume of about 11 6 m 3 over an area of about 1,31 km 2. Besides the main shock and large aftershocks, the rainfall before the earthquake is likely to affect the extensive slope failure as well. This area had been subjected to a continuous heavy rainfall, more than 1 mm/day, leading up to 2th October, so the soil was well saturated and the ground water level was raised from the normal level. With saturated soil and higher ground water level, slope failure is more likely to occur than under normal conditions. This study intends to investigate the mechanism of slope failure triggered in the Chuetsu Earthquake by performing triaxial compression (TC) tests. Two cases of failed slope in the earthquake were investigated: one is located at Yokowatashi, Ojiya City near Shinano River, and the other is at Higashi-Takezawa at Yamakoshi Village (currently Nagaoka City). In Yokowatashi case, the failed slope is 4 m wide and 7 m long with a dip angle of about 22 degrees, and its conditions before failure required more detailed investigation. A feature of this failure is that, on the planar sliding 1 Graduate student 2 Technical staff 3 Expert engineer, Core Laboratory, OYO Corporation 4 Support promotion member 5 Professor

surface, there was a sandy soil layer with a thickness of 1 to 3 cm which is sandwiched by silt softrocks. This sandy layer is the emphasis of this study, but may be easily overlooked at the time of geotechnical survey. In Higashi-Takezawa case, the failed slope is 295 m wide, 35 m long with a dip angle of 18 at top region and 2 at toe region of the slope. Regarding its morphological characteristics, Chigira et al. (26) argued that the earthquake reactivated a pre-existing failure plane which then formed most of the present sliding plane. This paper focuses on the triaxial compression test results on undisturbed cylindrical specimens from Yokowatashi site and prismatic specimens from Higashi-Takezawa site. Comparison will be made between the present test results and the results of plane strain compression (PSC) tests and TC tests on prismatic specimens from Yokowatashi site in Deng et al. (27). The conclusion in this paper can be used to analyze the stability of the two slopes before failure, which will be reported elsewhere. Failed slope Elementary school a) b) (photo by Kokusai Kogyo, 24) Figure 1. Investigated failed slopes a) at Yokowatashi and b) at Higashi-Takezawa APPARATUS, SPECIMENS AND TEST PROCEDURES Apparatus Although direct shear tests and ring shear tests are usually conducted in studies on slope failure, triaxial compression tests were performed in this research due to the existence of the weak layer. Some of the specimens used in this research had a weak layer as described later in this paper, and a shear band formed within the weak layer. However, the exact location of the shear band could not be predicted accurately before shear. This inaccuracy may induce large scatter in the measured strengths. Direct shear tests and ring shear tests have disadvantages in investigating the strength of such specimens, because a clear sliding surface should be determined before shear in these tests. On the contrary, in triaxial compression tests, shear band can form without any artificial interference. The apparatus used in this study was a modified version of PSC test apparatus (Salas Monge et al., 22, and Deng et al., 27). Without employing the lateral confining plates, this apparatus can be used to perform TC test on prismatic specimens and cylindrical specimens by changing the top cap and pedestal. An external displacement transducer was used to measure the global axial strain, and Local Deformation Transducers (LDTs) were used to measure the deformation near the weak layer and the deformation of softrock. The volume change was measured by a Low Capacity Differential Pressure Transducer (LCDPT), and the minor principal stress was measured by a High Capacity Differential Pressure Transducer (HCDPT). A.3-mm-thick membrane was used, and dots were imprinted on the membrane at a spacing of 5 mm. For prismatic specimens, a digital camera with a resolution of 8 mega pixels was used to take photos of these dots for image analysis.

Specimens and Test procedures In total, seven types of specimens retrieved from two failed slopes were used in the current study for various purposes as listed in Table 1. Table 1. Summary of test conditions test No. test type 1) saturation condition 2) test condition for shear 3) B-value effective confining pressure 3i q 4) t 6) (mm R-1 7) PSC DVS D 67.5 5 - - - R-2 7) PSC DVS UD 94.2 54 - - - PSC-1 7) PSC DVS UD 97.4 49 39 61.7 - TC-1 7) TC DVS UD 86.7 48 45 54.4 - TC-2 7) TC DVS UD 98.9 51 45 54.8 - TC-3 7) TC DVS D 98.2 9-56.3 - TC-4 7) TC DVS D 97.6 2-6.1 - TC-5 7) TC US D - 45-47.5 - TC-6 7) TC US D - 9-51.9 - TC-7 7) TC US D - 2-62.2 - TC-8 7) TC DVS UD 98.5 52 44 53.1 - TC-9 7) TC DVS UD 98.8 45 45 51.3 - R-P-1 UcC Air-dried - - - - - R-P-2 UcC Air-dried - - - - - TC-PU-1 TC DV UD 99. 43 37 6.4 - TC-PU-2 TC DV UD 98.3 44 2 64. - TC-PU-3 TC DV UD 99.2 2 45 62.6 - TC-PB-1 TC DV UD 99.2 45 45 66.7 - TC-PB-2 TC DV UD 98.7 46 45 67.4 - TC-PB-3 TC DV UD 99.1 45-6.1 - H-1 TC DV UD 99.1 46 28 67.9 3 H-2 TC DV D 99.1 44-66.4 3-24 H-3 TC DV D 98.3 2-65.4 7-32 H-4 TC DV D 98.8 9-62.5 3 H-5 TC DV D 98.8 9-54.9 12-22 H-6 TC DV D 99.2 89-55.9 3-18 H-7 TC DV UD 98.8 45 6. 3 H-8 TC DV UD 99.2 45 45 56. 3 1) UcC: Unconfined Compression test; TC: Triaxial Compression test. 2) DV: Saturated by double vacuuming method 3) D: Drained; UD: Undrained. 4) deviator stress during creep, q 5) orientation of sandy or clay layer, 6) clay layer thickness, tmm 7) reported in detail by Deng et al. (27) Undisturbed cylindrical specimens ( 123 mm, typically as shown in Figure 2 a)) including R-P-group, TC-PU-group and TC-PB-group were retrieved by a rotary sampler using a planet gear (Sugawara et al., 1996) from the Yokowatashi site. Figure 3 is a sketch showing the sampling location, where the sketched cross-section corresponds to the direction of the arrow shown in Figure 1. Although only one boring hole is shown in Figure 3,the other holes were also drilled in parallel to this hole at a horizontal distance of 2~8m from the sketched surface. As shown in Figure 3, R-P-group specimens were softrock which did not contain the thin sandy layer; TC-PU-group contained a slightly weathered sandy layer which was located about 2m higher than the sliding plane; TC-PB-group

contained a sandy layer on which the sliding took place. The sandy layer in TC-PB-group was weathered, while the weathered soil did not flow away with water except one small cavity that was found in the sandy layer in specimen TC-PB-2. All the specimens were trimmed in laboratory to avoid contact between the sandy layer and top cap or pedestal, with the exception of TC-PB-3, where a small part of sandy layer was in contact with the pedestal which is discussed later in the paper. 1 1 Softrock Sandy layer 3mm t Softrock 3 3 16 mm Softrock 12mm Direction of pedestal momvement Softrock Sandy clay layer Previously sliding plane 6 mm Direction of pedestal momvement 8 mm a). Cylindrical specimen (TC-PB-1) b). Prismatic specimen (H-2) Figure 2. Sandwiched specimen Boring hole No. 1 2m TC-PU- group R-P- group TC-PB- group Sliding plane Figure 3. Sampling location at Yokowatashi site R-group prismatic specimens (Deng et al., 27) were retrieved by the block sampling corresponding to the R-P-group (Figure 3). TC-group and PSC-group prismatic specimens (Deng et al., 27) which contained a sandy layer were also retrieved by block sampling near the sketched surface which is marked as a shadowed area in Figure 3. H-group specimens (widthlengthheight=6816 mm, typically as shown in Figure 2 b)) were retrieved from the Higashi-Takezawa siteby block sampling method at the location where the previous sliding plane passed through (Figure 4). According to Kameya et al. (27), some small cavities were found in the sandy clay layer. Except for the specimens R-P-1 and R-P-2, all the other specimens in Table 1 were saturated, and filter paper was used at the side of the specimen to ensure saturation and possible drainage. With an effective confining stress 3 of 2~3 kpa, the specimens were firstly saturated by using the double vacuuming method which consists of vacuuming, flushing with de-aired water and back pressurization

(Ampadu and Tatsuoka, 1993). For undrained shearing tests, TC-PB-1, TC-PB-2, H-1 and H-7, after isotropic consolidation, drained loading was performed until the deviator stress q 1 (= 1 3 ) reached the prescribed value (q ) to reproduce the in-situ drained state before earthquake. After a 5-minute drained creep loading with the deviator stress q 1 =q, undrained creep loading was applied for 1 minutes to reproduce the in-situ stress condition just before the earthquake. Finally, undrained monotonic/cyclic shearing was applied until the end of test. For the other undrained shearing tests, undrained shearing was started from the isotropic stress state. Ground water level Sliding plane Sampling location Previous sliding plane 2 35m 18 Figure 4. Sampling location at Higashi-Takezawa site (sketch by SABO Technical Center et al. (25)) In the cyclic loading tests, undrained cyclic loadings with a double amplitude deviator stress, q d, of 3, 6, 9, 12 and 15 kpa were applied step by step. At each loading step, ten cycles were applied. Finally, undrained monotonic loading was applied to the specimen. For saturated drained test, the specimens were consolidated isotropically. The B value was measured after saturation. Finally, drained monotonic loading was applied under a constant confining stress. For unsaturated tests, specimens were sheared directly after consolidation under a constant confining stress, while maintaining the initial water content. For all the H-group tests, lubrication was applied at the interfaces between the specimen and the top cap and pedestal. The pedestal used in this group tests could move horizontally in one direction (Figure 2 b)). For the other groups of specimens, the pedestal could move in any arbitrary direction in the horizontal plane (Figure 2 a)), making lubrication at the interfaces between the specimen and the top cap and pedestal unnecessary. For all the tests, during monotonic loading and cyclic loading, the axial strain rate was.2%/min. TEST RESULTS AND DISCUSSION Test results on R-P-group specimens Figure 4 shows that softrock specimens (R-P-group) had a peak strength of about 3 kpa and their corresponding secant Young s modulus E sec, measured with the external displacement transducer, was about 13~23 MPa. As compared to the previous test results on R-group in Deng et al. (27), the strength of R-P-group was similar to that of the R-group, while its secant Young s modulus E sec was significantly smaller than that of R-group. Similarly, a smaller secant Young s modulus was also confirmed by LDT measurement as shown in Figure 5. The softer behavior of R-P-group specimens was likely to be relevant to the cross-sectional cracks, possibly induced during the sampling process, while the strength of softrock seemed to be unaffected by the cracks.

Test results on TC-PU-group specimens Figure 6 shows the undrained test results of TC-PU-group specimens with different effective confining stresses. In Figure 6 a), the specimen TC-PU-3 had a peak strength of over 5 kpa with an initial effective confining stress of 2 kpa. It can be seen in Figure 6 b) that though the specimens (= 1-3 ) 4 3 2 1 E sec No. R-P-1 R-P-2 R1 5 R2 54 1 undrained 1 2 3 4 Axial strain by external transducer, 1,EXT Figure 4. Stress-strain relationships measured by external transducer in R-P-group specimens (= 1-3 ) 4 3 2 1 E sec 1..5 1. 1.5 2. Axial strain by LDT, 1,EXT No. R-P-1 R-P-2 R1 5 R2 54 undrained Figure 5. Stress-strain relationships measured by LDT in R-P-group specimens (= 1-3 ) 16 12 8 4 No. TC-PU-1 43 TC-PU-2 44 TC-PU-3 2 16 12 8 4 No., 3i TC-PU-1 43 TC-PU-2 44 TC-PU-3 2 peak peak q 1 2 16 12 8 4 peak 2 4 6 8 2 4 6 8 Axial strain by external transducer, 1,EXT 2 4 6 8 Effective mean principal stress, p, a) Stress-strain relationships b) p -q 1 relationships p, Stress ratio on shear band, R= ' 2. 1.6 1.2.8.4. not on sandy layer No. TC-PU-1 43 TC-PU-2 44 TC-PU-3 2 4 8 12 16 2 Sandy layer Crack by sampling Shear band Nominal shear strain, c) R- relationships d) Failure in TC-PU-1 Figure 6. Tests on TC-PU-group

were contractive at the beginning of shearing, the dilative behavior was mobilized at the peak state. The contractive behavior of this group at the start of undrained shear may be affected partly by horizontal cracks which were possibly induced during sampling. Figure 6 c) shows the R- relationships in TC-PU-group on shear band, where R is shear stress ratio on shear band, and is nominal shear strain. R- relationships were fairly similar to each other. Refer (= 1-3 ) 16 12 8 4-4 No. TC-PB-1 45 TC-PB-2 46 TC-PB-3 45 16 12 8 4-4 No. TC-PB-1 45 5 1 15 2 Axial strain by external transducer, 1,EXT 2 4 6 8 Effective mean principal stress, p, a) Stress-strain relationships in TC-PB-group b) p -q 1 relationship in specimen TC-PB-1 16 16 12 8 4 No. TC-PB-2 46 12 8 4 No. TC-PB-3 45-4 -4 2 4 6 8 2 4 6 8 Effective mean principal stress, p, Effective mean principal stress, p, c) p -q 1 relationship in specimen TC-PB-2 d) p -q 1 relationship in specimen TC-PB-3 Stress ratio on sandy layer, R= ' 1.5 1..5. -.5 No. TC-PB-1 45 TC-PB-2 46 TC-PB-3 45 Stress ratio on sandy layer, R= ' 1.5 1..5. -.5 No. TC-8 52 TC-9 45 8 16 24 32 8 16 24 32 Nominal shear strain, Nominal shear strain, e) R- relationships in TC-PB-group specimens f) R- relationships in TC-group specimens Figure 7. Test results on TC-PB-group and TC-group specimens

to Deng et al. (27) for the details on measurement of shear band orientation and the calculation of nominal shear strain. As shown in Figure 6 d), the shear band in specimen TC-PU-1 was not on the sandy layer. In addition, the peak of stress ratio R max was over 1.6 which was much higher than that of specimens in TC-PB-group as shown later (Figure 7 e)). These two facts suggest that the sandy layer in this group was not deeply weathered and had high strength, so it did not fail during the earthquake. Test results on TC-PB-group specimens Figure 7 shows undrained cyclic loading test results on TC-PB-group specimens. In Figure 7 a), under similar test conditions, specimens TC-PB-1 and TC-PB-2 exhibited a peak deviator stress of about 8 kpa. In the subsequent cycles, no significant accumulation of excess pore water pressure can be seen in Figures 7 b) and c). For all the three tests, although the excess pore water pressure increased dramatically before exhibiting a peak deviator stress, the effective stress path did not pass the origin as shown in Figures 7 b), c) and d). These results were possibly affected by the membrane compliance as described in Deng et al. (27). In Figures 7 e) and f), R- relationships in TC-BP-group specimens and TC-group specimens (TC-8 and TC-9) are plotted respectively. TC-PB-group specimens exhibited similar R- relationships to those of TC-group specimens, except that their mobilized residual stress ratios were higher than those of TC-group specimens which were retrieved very near the failed slope. The pattern of shear band formation observed in the current study was different from the one observed in the previous prismatic specimens TC-8 and TC-9. In this TC-PB-group, the shear band (Figure 8) was thin and always located on the lower boundary which was between the sandy layer and the bottom softrock, except for a small part of shear band in TC-PB-3 (Figure 9) that was formed along the upper boundary between the sandy layer and the upper softrock as the bottom boundary touched the pedestal. In the previous tests of TC-group (Figure 1), on the other hand, the shear band was much thicker and contained some crushed blocks. Soft rock Dense sandy layer Upper boundary Lower boundary Lower boundary Soft rock Figure 8. Failure in TC-PB-1 Figure 9. Failure in TC-PB-3 Monotonic loading test results on H-group specimens Figure 11 shows monotonic loading test results on H-group specimens. In Figure 11 a), no significant strain soft was observed. As the bottom rock block of specimen H-5 touched the top cap and pedestal after the axial strain exceeded 1.7%, its peak deviator stress was much higher than those the other specimens that were tested under similar conditions. In Figure 11 c), the peak value of the shear stress ratio that was mobilized on the sandy clay layer varied within a range of.6 to.9, and its residual value is only slightly lower than the peak value. Figure 11 d) summarizes relationships in monotonic loading tests in H-group. The failure envelopes for the peak and residual stress states were also drawn in the figure. As a result, the strength parameters as listed in Table 2 were obtained.

Soft rock Sandy layer Intermediate Block Sandy layer Lower boundary Soft rock a) before shearing b) after shearing Soft rock Sandy layer Crushed block Sandy layer Lower boundary Soft rock Figure 1. Crushing of intermediate blocks in specimen TC-5 (= 1-3 ) 5 4 3 2 1 undrained ' c =9kPa ' c =45kPa ' c =2kPa H-1 H-2 H-3 H-4 H-5 H-6 5 4 3 2 1 H-1 H-2 H-3 H-4 H-5 H-6 undrained 5 1 15 2 Axial strain by external transducer, 1,EXT 5 1 15 2 25 Effective mean principal stress, p, a) Stress-strain relationships b) p -q 1 relationships Stress ratio on clay layer, R= ' 1..8.6.4.2. H-1 H-2 H-3 H-4 H-5 H-6 undrained Shear stress on clay layer, 24 2 16 12 8 4 H-1 H-2 H-3 H-4 H-5 H-6 undrained 8 16 24 32 Nominal shear strain, 5 1 15 2 25 Normal stress on clay layer, c) R- relationships d) Shear stress-normal stress relationships on sandy clay layer Figure 11. Test results on H-group in monotonic loading

Table 2. Strength parameters of H-group specimens in monotonic loading peak (deg.) c peak res (deg.) c res Saturated specimens 36.2 35.4 Strain localization occurred within the whole region of the sandy clay layer having a width in the range of 3 mm to 32 mm (Figure 12) that had irregular interfaces with the soft rock blocks. Their stiffnesses were different from each other: increasing in the order the sandy clay layer, the upper softrock block, the lower soft rock block. The sandy clay layer can be pinched by finger easily, while the lower softrock block can not be pierced even by a scoop. Upper softrock block Sandy clay layer Upper softrock block Sandy clay layer Upper softrock block Lower softrock block Lower softrock block Sandy clay layer Lower softrock block a) H-1 b) H-2 c) H-3 Figure 12. Sandy clay layers in H-group Cyclic loading test results on H-group specimens Neither specimen H-7 nor specimen H-8 liquefied as shown in Figure 13. As is the case with the test results on TC-PB-group as shown in Figure 7, the test results on specimens H-7 and H-8 were possibly affected by the membrane compliance as described in Deng et al. (27). Summary of test results on specimens retrieved from Yokowatashi The previous test results on prismatic specimens (Deng et al., 27) and the current test results on cylindrical specimens are summarized in this section. The strength was likely to be affected by the soil type, degree of weathering and degree of erosion. The softrock specimens of R-group in Deng et al. (27) and R-P-group in this paper, which did not contain the sandy layer, had a peak strength of over 3 MPa in unconfined compression tests or TC tests. The specimens, with slightly weathered sandy layer (TC-PU-group), had a peak strength of over 5 kpa under an initial effective confining stress of 2 kpa, and the corresponding shear stress ratio mobilized on the sandy layer was over 1.6. The specimens in TC-PB-group, which had been deeply weathered while having a few cavities in the sandy layer, mobilized the peak stress ratio of 1.3 in undrained tests. Specimens in TC-group in Deng et al. (27), which contained deeply weathered sandy layer and many visible cavities, were the weakest among the five groups tested in this present study, so the failure occurred along this sandy layer. The failure patterns were different among the six groups. The R-group and R-P-group specimens failed in the test like a common softrock. In two cases of specimens in TC-PU-group, the shear band was mostly formed within the sandy layer. The shear band of specimens in TC-PB-group was formed along the boundary between the sandy layer and the lower softrock when the boundary did not touch

16 16 (= 1-3 ) 12 8 4-4 No. H7 45 H8 45 12 8 4-4 No. H7 45 H8 45-2 2 4 6 8 1 12 14 16 18 Axial strain by external transducer, 1,EXT 2 4 6 8 Effective mean principal stress, p, 1. Stress ratio on clay layer, R= '.8.6.4.2. No. H7 45 H8 45 4 8 12 16 2 24 28 32 Nominal shear strain, the pedestal. For the specimens in TC-group and PSC-group which contained many visible cavities, the shear band was very thick and crushing of intermediate sandy softrock blocks were observed. The failure pattern seems to contribute to the large residual displacement of slope that was induced by the earthquake. It is reasonable to extrapolate that in the failed slope there were more cavities in the saturated sandy layer. So, when these cavities, that were sandwiched between adjacent softrocks, having low permeability were compressed during sliding, the pore water pressure could increase significantly. Summary of test results on specimens retrieved from Higashi-Takezawa site The H-group specimens also had a weak sandy clay layer which was 3 to 32mm thick according to the measurement after failure. The shear band with an irregular interface was always formed within this sandy clay layer. The peak strength of H-group was c=, Figure 13. Cyclic loading test results on H-group 36.2 which was weaker than that of the TC-group from Yokowatashi site. As the dip angle was 18~2, the slope was stable under normal condition when there was no earthquake and the ground water level was not extremely high. The increment of strain induced by cyclic loading was very limited, and full liquefaction did not occur under undrained cyclic loading conditions. CONCLUSIONS The following conclusions can be drawn from the test results presented in this paper: 1) For the specimens retrieved from Yokowatashi site, the strength was affected by material type and

degree of weathering. The TC-group specimens which were retrieved very near the failed slope were the weakest among the tested specimens. 2) For the specimens retrieved from Yokowatashi site, the failure pattern was affected by the material type, the degree of weathering and the existence of cavities. The TC-group specimens had a very thick shear band, while the TC-PU-group specimens which were retrieved from the locations far from the failed slope had a thin shear band along the boundary between the sandy layer and the lower softrock. 3) For the specimens retrieved from Higashi-Takezawa site, the strength was lower than that of the specimens retrieved from Yokowatashi site. In both cases, a weak layer was found on the shear band formed in the tests. 4) In the cyclic loading tests, full liquefaction did not occur. This may be affected by the effects of membrane compliance. ACKNOWLEDGMENT This study was conducted as a part of the research on "Earthquake damage in active-folding areas: Creation of a comprehensive data archive for remedial measures for civil-infrastructure systems" that is supported by Special Coordination Funds for Promoting Science and Technology of Japan Ministry of Education, Culture, Sports, Science and Technology. REFERENCES Ampadu, S.K. and Tatsuoka, F. (1993). Effect of setting method on the behavior of clays in triaxial compression from saturation to undrained shear. Soils and Foundations, 33 (2), 14-34. Chigira M. and Yagi H. (26). Geological and geomorphological characteristics of landslides triggered by the 24 mid Niigata prefecture earthquake in Japan. Engineering Geology, 82(4), pp. 22 221. Deng J., Tsutsumi Y., Kameya H., Sato T. and Koseki J. (27). Plane Strain and Triaxial Tests on Undisturbed Samples Retrieved from Failed Slope due to Earthquake. Bulletin of ERS, No. 4, pp. 99-112. Kameya, H., Kanai T., Deng J., Tsutsumi Y. and Koseki J. (27). Field investigation and retrieval of samples from a failed slope by Chuetsu Earthquake at Higashi-Takezawa. Proc. Japan National Conf. on Engrg. Geology in 27, JSEG, Osaka, pp. 153-154 (in Japanese) Kokusai Kogyo Co. LTD. (24), http://www.kkc.co.jp/social/disaster/241_niigata_eq/n/9.html (in Japanese) Ministry of Land, Infrastructure and Transport (25). Information on the Chuetsu Earthquake. http://www.mlit.go.jp/kisha/kisha5/5/5113_.html (in Japanese). SABO Technical Center et al. (25). A business report on the examination of countermeasure for landslides at Terano and Higashi-Takezawa in 24. (in Japanese). Salas Monge, R. and Koseki,J. (22). Plane strain compression tests on cement treated sand. Proceedings of the Fourth International Summer Symposium, JSCE, Kyoto, pp. 223-226. Sugawara N., Ito Y. and Kawai M. (1996). New core sampler with planet gear for investigating the cement-mixed ground, Proc. of IS-Tokyo'96/the second international Conf. on Ground Improvement Geosystems, Tokyo, pp.653-658