SlimLine Sensors (SLS)

Similar documents
Load Washers. Force kn until kn. Type 9101A A

Load Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B

ED 701 General Industry Pressure Transmitter

ZF Series Force Transducers

Precision Ball Screw/Spline

Tie Bar Extension Measuring Chain

D a t a s h e e t. F o r c e T r a n s d u c e r. S e r i e s K. ( 4 k N k N ) Benefits/Application. Options/Accessories

Benefits/Application. Very high-cycle fatigue resistant up to 100 % of nominal load. Extremely robust against side forces and bending moments

Force Sensors. Transparent Manufacturing Processes Ensure Quality and Reduce Costs.

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction

Rotary modules.

Benefits/Application. For static and dynamic tensile and compressive forces. Easy assembling, lots of possibilities. Options/Accessories

THE NEW 1.1 MN m TORQUE STANDARD MACHINE OF THE PTB BRAUNSCHWEIG/GERMANY

Product description. Compact Modules. Characteristic features. Further highlights

Direct-operated 2/2-way compact solenoid valves Type EV210A

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

Direct-operated 2/2-way solenoid valves Type EV210B

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Investigation of Piezoelectric Force Measuring Devices in Force Calibration and Force. Standard Machines

Hilti North America Installation Technical Manual Technical Data MI System Version

Product Description. Further highlights. Outstanding features. 4 Bosch Rexroth Corporation Miniature Linear Modules R310A 2418 (2009.

TOP Transfer. Data sheet. Force transfer standard. Special features. B en

Solenoid valves 2/2-way direct-operated type EV210A

TOP Transfer. Data Sheet. Force transfer standard. Special characteristics. D 20.TOPTRANS.10 en

Application example. Measuring Force Sensors Rigid. Six series Nano, Mini, Gamma, Delta, Theta, Omega. Range of measurement, force ± 36 N..

Lever-type Dial Test Indicators

Lever-type Dial Test Indicators

The basic dynamic load rating C is a statistical number and it is based on 90% of the bearings surviving 50 km of travel carrying the full load.

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

CHAPTER 6 FRICTION AND WEAR ANALYSIS FOR BUSHING

Type UB1 Load Cell. Option Stainless steel cable gland

E8EB-N0C2B E8EB-N0B2B

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

Relative pressure transmitter type 520

Benefits/Application. Very high-cycle fatigue resistant up to 80 % of nominal load. Easy assembling, lots of possibilities. Options/Accessories

Cat. Multi-Processors. Hydraulic Excavators. Multi-Processor/Hydraulic Excavator Compatibility. Features: Maximum Productivity.

FOUR-POINT CONTACT SLEWING RINGS - without gear [ O ]

Identification Number

Pressure Transmitter ED 701

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

Project PAJ2 Dynamic Performance of Adhesively Bonded Joints. Report No. 3 August Proposed Draft for the Revision of ISO

COMMON BLACK IRON & BLADE PARTS

Cartridge Valves Technical Information. Quick reference

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

Glossary Innovative Measurement Solutions

all stainless steel transducer multimedia compatibility

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Identification system for short product names. Changes/amendments at a glance. 2 Bosch Rexroth AG OBB omega modules R ( )

1 Input data. Profis Anchor Company: Specifier: Address: Phone I Fax: Page: Project: Sub-Project I Pos. No.

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Investigation of basic elements loading and tension of heavy hydraulic presses for metallurgical production

Parallel grippers HGPLE, sturdy with long stroke, electric

HD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 8700 psi Nominal flow rate up to gpm us

Metal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials)

Module 2 Mechanics of Machining. Version 2 ME IIT, Kharagpur

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Flow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31.

Size A DIN EN

Series MHY2/MHW Angular Gripper. Cam actuation style is now standardized! MHZ2 MHZJ2 MHQ MHL2 MHR MHK MHS MHC2 MHT2 MHY2 MHW2 MRHQ 2.

Operating Instructions for Digital Manometer. Model: MAN-SD

CTV series CHARACTERISTICS LINEAR UNITS

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Technical information CONCRETE / SOLID STONE. Reaction resin mortar, epoxy-acrylate-based with styrene USAGE INSTRUCTIONS

ZF Maschinenantriebe GmbH Industrial Drives. Planetary gearboxes Economy Series for Servomotors

TE 75R RESEARCH RUBBER FRICTION TEST MACHINE

Hilti North America Installation Technical Manual Technical Data MI System Version

SKF actuators available for quick delivery. Selection guide

Design and analysis of a piezoelectric film embedded smart cutting tool

2D - STRIP ANCHOR LIFTING SYSTEM

Analyzing and Commanding

10012 Creviston DR NW Gig Harbor, WA fax

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

V 12: Miniature photoelectric switches in M 12 housings

ATEX/IECEx RTD temperature probe

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

The perfect Torque Limiting Clutch for

Pressure transmitters for industrial applications MBS 32 and MBS 33

Elastic Properties of Solids (One or two weights)

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

1 Input data. Profis Anchor Company: Specifier: Address: Phone I Fax: Page: Project: Sub-Project I Pos. No.

Cam Roller Guides. The Drive and Control Company. Service Automation. Electric Drives and Controls. Linear Motion and Assembly Technologies

T e c h n i c a l L e x i c o n

Industrial Pressure Transmitter

Theoretical Calculation and Experimental Study On Sung Torque And Angle For The Injector Clamp Tightening Bolt Of Engine

Design against fluctuating load

MET 301 EXPERIMENT # 2 APPLICATION OF BONDED STRAIN GAGES

Drive Units with Ball Screw Drives R310EN 3304 ( ) The Drive & Control Company

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2..

Cooler-Bypass Thermostat Valve, Size 10

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features

Piezo Theory: Chapter 1 - Physics & Design

Initial Stress Calculations

Example 4: Design of a Rigid Column Bracket (Bolted)

MEMS Project 2 Assignment. Design of a Shaft to Transmit Torque Between Two Pulleys

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2...

Note to reviewers: See next page for basis for the change shown on this page. L-3160 TANGENTIAL CONTACT BETWEEN FLANGES OUTSIDE THE BOLT CIRCLE

Transcription:

Force SlimLine Sensors (SLS) Measurement of Dynamic and Quasistatic Forces, 0 3 kn up to 0 80 kn Quartz sensor series with extremely flat design for measuring dynamic and quasistatic forces. High resolution, high rigidity and extremely small dimensions characterize this sensor. Its characteristics make it ideal for mounting in mechanical structures. Its case is hermetically sealed and it has an integral splash-proof connecting cable with connector. Type 9130... up to 9137 F z SlimLine sensors are supplied uncalibrated and must be calibrated in situ after mounting for absolute measurements. Extremely small size with a wide measuring range Flexible mounting in force shunt mode Also suitable for tensile forces when preloaded Measures practically free of displacement, wear and fatigue Measures even small forces with high resolution Sealed case (rated at IP65) Integral non-detachable cable with Viton cable covering Technical Data Description The force F to be measured acts on the sensor via the preloading or mounting structure and produces an electric charge directly proportional to the force. This is measured by an electrode and fed to the charge amplifier via the integral cable. Application ecause of their high rigidity, SlimLine sensors are especially suitable for measuring rapidly changing forces, but quasistatic measurements over several minutes are also possible. The SlimLine sensor is especially suitable for measuring forces in shunt mode (Fig. 5). This means that the sensor is embedded and preloaded in a structure; it is therefore loaded only with part of the process force. Its small size is ideal for installation in structures such as force plates, fitting strips and tools. The sensor is used in industrial production processes wherever forces are monitored or measured. Used with a ControlMonitor, this sensor is ideal for quality control and monitoring in large scale industrial production. Examples of Application Monitoring of press forces, punching forces etc. Tool monitoring Measurement of large forces in force shunt mode Incorporation in dynamometers with small dimensions Type Measuring Range Overload Sensitivity Rigidity F z [kn] F z [kn] [pc/n] [kn/μm] 9130 0 3 3,5 3,5 1,0 9131 0 2,5 3 4,0 0,7 9132 0 7 8 3,8 1,8 9133 0 14 17 3,8 2,5 9134 0 26 30 3,8 5,6 9135 0 36 42 3,8 7,0 9136 0 62 72 3,8 8,0 9137 0 80 96 3,8 16,0 Linearity (preloaded) %/FSO ±1,0 Hysteresis (preloaded) %/FSO 1,0 Response threshold N < Operating temperature range C 20 120 Preloading force (recommended) F v Direct connection 1) %/FS 50 Shunt mode %/FS 20 Protection rating 2) EN60529 IP65 1) The preloading force must be selected according to the tensile/compression force range required and according to the information on Page 3 concerning bending moment. 2) IP protection based on EN60529 is ascertained with water. Oils, emulsions, coolant/cutting fluids etc. mostly have a better wetting and penetration capacity. For contact with such fluids, the degree of protection must be classified as being correspondingly lower. Page 1/5

Dimensions Type D d H Weight [mm] [mm] [mm] (without cable) m [g] 9130 8,0 2,7 3,0 1 9131 * 7,0 3,0 1 9132 12,0 4,1 3,0 2 9133 16,0 6,1 3,5 3 9134 20,0 8,1 3,5 5 9135 24,0 10,1 3,5 7 9136 30,0 12,1 4,0 14 9137... 36,0 14,1 5,0 27 * Type 9131 without a bore [d] Fig. 2: SlimLine sensor dimensions Sensor Mounting SlimLine sensors should basically be used only preloaded in a mounting structure, either directly in the force flux of a separate component or in force shunt mode embedded in a machine structure. With direct force measurement, the largest part of the process force flows through the sensor, in the case of force shunt measurements it is loaded with only a very small part of the process force. SlimLine sensors are supplied uncalibrated, because in any case they must be calibrated in situ in the mounting structure for absolute measurements. Direct Force Measurement in the Force Flux With direct force measurement, almost the entire process force flows through the sensor. The measuring range must therefore be selected so that the sum of preloading force F p and maximum occurring process force F z is within the measuring range of the sensor. The mounting surfaces must be flat, rigid and ground (Fig. 3). The preloading bolt produces a force shunt of 7 10 % and a correspondingly reduced sensitivity. In general, a preloading force of at least 20 % of the measuring range is recommended; with tensile forces this should be increased accordingly. If possible (considering the process force), preloading of 50 % of the measuring range should be used, because the tolerance with bending moments is then at its greatest, see Page 3. Mounting Dimensions Mounting Dimensions Thread ore Diameter Plate Thickness 1) Type d1 [mm] A [mm] 9130 M2,5 2,9 8,0 9132 M4 4,3 8,0 9133 M6 6,4 12,0 9134 M8 8,4 16,0 9135 M10 10,5 20,0 9136 M12 13,0 24,0 9137... M14 15,0 27,0 1) Recommended minimum plate thickness Fig. 3: Dimensions for direct force flux mounting Fig. 1: Direct force measurement Page 2/5

ending Moments ending moments may not only have a negative influence on the measurement, but may even lead to destruction of the sensor. However, when the sensor is mounted in a thrust rod or a punch press, it is often impossible to avoid bending moments entirely. The permissible value for the bending moment M b is dependent on the sum of the preloading force F p and the current process force F z applied, in which the maximum possible bending moment M b,max is reached at the half of the range limit value (Fig. 4). Maximum Possible ending Moment Type Range Limit Value Max. possible ending Moment M b,max. [kn] [N m] 9130... 3,0 1,50 9131... 2,5 1,50 9132... 7,0 5,15 9133... 14,0 15,00 9134... 26,0 35,00 9135... 36,0 62,00 9136... 62,0 134,00 9137... 80,0 244,00 With the table values for and M b,max, the permissible pure bending moment as a function of the preload force F p and the process force F z can be estimated as follows: (1a) M b,perm. (F p + F z) F p + F z /2 (1b) M b,perm. ( F p F z) F p + F z /2 Attention If a bending moment M b = F x,y h is produced by a lateral force F x,y at a distance h from the reference plane, this will lead to a shear force F x,y in the sensor plane. In this case, the maximum permissible bending moment is lower than the permissible value for a pure bending moment determined using the equations (1). Example 1 A SlimLine sensor Type 9135 is preloaded with F p = 10 kn. What bending moment is acceptable for process forces in the range of F z = 0 12 kn? F p + F z,min /2 10 kn 18 kn (1a) M b,perm = 2 62 N m 10 kn = 34,4 N m 36 kn F p + F z,max /2 22 kn 18 kn (1b) M b,perm = 2 62 N m 14 kn = 48,2 N m 36 kn To avoid a sensor overload within the whole measuring range, the bending moment must not be greater than 34,4 N m. Example 2 A SlimLine sensor Type 9132 is preloaded with 3 kn. How wide is the measuring range with a bending moment M b of 2 N m? y resolving (1) according to F z, we get the equations (2) with which the permissible measuring range for the process force F z can be calculated as a function of a bending moment M b. In the bending moment graph, the equations (1) limit the range of the permissible bending moment as a function of F p and F z. (2a) F z,min M b F p ending Moment Graph (F p + F z) ( F p F z) Permissible bending moment M b as a function of F p and F z Fig. 4: ending moment graph (pure bending moment) (F p + F z) (2b) F z,max (1 M b ) F p Inserting the values for, M b,max and F p produces the permissible measuring range for F z: from (2a) the max. tensil force F z = 1,64 kn and from (2b) the max. press force F z = 2,64 kn Attention Lateral forces F x,y and/or a torque M z further reduce the measuring range. When the equations (2a) and (2b) are resolved according to F p, the minimum preload force required or the maximum permissible preload force can be calculated as a function of the other parameters. Page 3/5

Mounting in Force Shunt Mode The widest variety of measuring problems can be solved with the SlimLine sensor mounted in force shunt mode. The mounting surface must be flat and be ground as finely as possible. Preferably, the SlimLine sensor is mounted with a preloading disk from Kistler (optional accessories) and preloaded to 10 20 % of the measuring range. The surfaces of the structure and preloading disk must all be ground jointly, with the preloaded sensor integrated in the structure. The slight projection P recommended for the preloading disk is achieved by then removing the sensor and grinding over the structure one path with the same depth of cut. This ensures a reproducible force shunt arrangement and good linearity. 0,2 Ma D1 0,5... 1 mm b max. 0,1 3 +0,5 0 0,02 Fig. 7: Installation in force shunt mode F Fig. 5: Force shunt measuring ground together P = Projection Fig. 6: Installation with preloading disk Type 9410A... Fig. 8: Assembly with preloading disk Type 9410A Mounting Dimensions SlimLine Sensor Thread orehole Diameter orehole Depth Undercut Projection Type Ma D1 [mm] t [mm] b [mm] P [μm] 9130... M2 8,5 6,5 1,2 0 2 9132... M2,5 12,5 6,5 1,2 0 2 9133... M3 16,5 7,7 1,2 0 3 9134... M4 20,5 7,7 1,2 0 3 9135... M5 24,5 7,7 1,5 0 3 9136... M6 30,5 9,5 1,5 0 3 9137... M8 36,5 12,0 1,5 0 3 Preloading Disk Type for SlimLine Thread D2 d2 H1 L Sensor [mm] [mm] [mm] [mm] 9410A0 9130... M2 8,0 2,7 3,50 8,0 9410A2 9132... M2,5 12,0 2,7 3,50 8,0 9410A3 9133... M3 16,0 3,2 4,25 10,0 9410A4 9134... M4 20,0 4,3 4,25 10,0 9410A5 9135... M5 24,0 5,3 4,25 10,0 9410A6 9136... M6 30,0 6,4 5,50 14,0 9410A7 9137... M8 36,0 8,4 7,00 16,0 D2 h8 d2 0 H1-0,05 Fig. 9: Preloading disk with countersunk screw L Page 4/5

Optional Accessories Type Preloading disk for SLS sensor Type 9130 9410A0 Preloading disk for SLS sensor Type 9132 9410A2 Preloading disk for SLS sensor Type 9133 9410A3 Preloading disk for SLS sensor Type 9134 9410A4 Preloading disk for SLS sensor Type 9135 9410A5 Preloading disk for SLS sensor Type 9136 9410A6 Preloading disk for SLS sensor Type 9137 9410A7 Adapter KIAG 10-32 neg. NC pos. 1721 Adapter KIAG 10-32 neg. KIAG 10-32 neg. 1729A Further Information SLS Assembly Two, three or four SlimLine sensors are incorporated in a sealed (IP65) plug connection with an individually selected cable length. Signals can be recorded as summation signals (parallel connection) or as single signals (series connection). Further information can be obtained from SlimLine Kit data sheet (9130A_000-168). Fig. 10: Adapter Type 1721 Fig. 11: Adapter Type 1729A (see also data sheets "Cables for Force, Torque and Strain Sensors" 1631C_000-346 and "Coaxial Cable Connectors, Cable Sockets, Couplings and Accessories" 1700A_000-347). Ordering Key Measuring Range 0 3 kn 0 0 2,5 kn 1 0 7 kn 2 0 14 kn 3 0 26 kn 4 0 36 kn 5 0 62 kn 6 0 80 kn 7 with KIAG 10-32 pos. integrated 2 with Mini-Coax neg. 3 Type 913 Fig. 12: SLS assembly SLS Quartz Force Link Calibrated SLS force links Types 9173 to 9176 are suitable for the measurement of tensile and compression forces. SlimLine sensors are mounted ground-isolated in preloading elements. For further information, see the data sheet for Slim- Line force links (9173_000-112). Fig. 13: Quartz force link Cable length L = 2 m (standard) 1 Specify cable length L in m 9 (L min = 0,1/L max = 2 m) The following connections can be used: L =... m KIAG 10-32 pos. int. Mini-Coax neg. Viton is a registered trademark of DuPont Performance Elastomers. Page 5/5