THERMAL AND OPTICAL CHARACTERIZATION OF PARABOLIC TROUGH RECEIVERS AT DLR S QUARZ CENTER RECENT ADVANCES

Similar documents
COMBINED MEASUREMENT OF THERMAL AND OPTICAL PROPERTIES OF RECEIVERS FOR PARABOLIC TROUGH COLLECTORS

HEAT LOSS MEASUREMENTS ON PARABOLIC TROUGH RECEIVERS

Material and Design Requirements for Advanced Concentrators

Available online at ScienceDirect. Energy Procedia 69 (2015 )

Chapter 5 MATHEMATICAL MODELING OF THE EVACATED SOLAR COLLECTOR. 5.1 Thermal Model of Solar Collector System

UNIT FOUR SOLAR COLLECTORS

Characterization of high temperature solar thermal selective absorber coatings at operation temperature

Experimental investigation of the performance of a Parabolic Trough Collector (PTC) installed in Cyprus

Heat Loss Testing of Schott's 2008 PTR70 Parabolic Trough Receiver

Simplified Collector Performance Model

Experimental and Theoretical Evaluation of the Overall Heat Loss Coefficient of a Vacuum Tube Solar Collector

FIELD TEST OF WATER-STEAM SEPARATORS FOR THE DSG PROCESS

Department of Energy Science & Engineering, IIT Bombay, Mumbai, India. *Corresponding author: Tel: ,

University of New Mexico Mechanical Engineering Spring 2012 PhD qualifying examination Heat Transfer

SOME ASPECTS ON PARABOLIC TROUGH FIELD OPERATION WITH OIL AS A HEAT TRANSFER FLUID

Fig 1. Power Tower during Operation

OPTIMIZATION of the GEOMETRY & MATERIAL of SOLAR WATER HEATERS.

N. Lemcoff 1 and S.Wyatt 2. Rensselaer Polytechnic Institute Hartford. Alstom Power

Construction and performance analysis of a three dimensional compound parabolic concentrator for a spherical absorber

Thermal Analysis of Solar Collectors

DETAILED MODELING OF SOLAR FLAT-PLATE COLLECTORS WITH DESIGN TOOL KOLEKTOR 2.2

An Evacuated PV/Thermal Hybrid Collector with the Tube/XCPC design

Available online at ScienceDirect. Energy Procedia 49 (2014 ) SolarPACES 2013

Thermal conversion of solar radiation. c =

HEAT LOSS CHARACTERISTICS OF A ROOF INTEGRATED SOLAR MICRO-CONCENTRATING COLLECTOR

Development of a Flat-Plate Calorimeter for a Small-Scale Heliostat Field

Temperature Measurement

EFFECT OF SOME PARAMETERS ON LINEAR FRESNEL SOLAR CONCENTRATING COLLECTORS

Ndiaga MBODJI and Ali Hajji

Performance Assessment of PV/T Air Collector by Using CFD

Simulation of a linear Fresnel solar collector concentrator

Corresponding author: Tel: , Fax:

EXPERIMENTAL INVESTIGATION OF DIFFERENT TRACKING MODES OF THE PARABOLIC TROUGH COLLECTOR

Experimental Evaluation of Natural Heat Transfer in Façade Integrated Triangular Enclosures

High Flux Solar Simulator and Solar Photo-Thermal Reactor: Characterization and Design

Glint and Glare Analysis

Thermal Performance Characterization of Embedded Pulsating Heat Pipe Radiators by Infrared Thermography

AssessmentofProfileErrorforEfficientSolarParabolicTrough

Collector test according to EN ,2:2002

HEAT LOSS SENSITIVITY ANALYSIS OF DIFFERENT LINEAR FRESNEL COLLECTOR RECEIVER GEOMETRIES

Supplemental Information. Storage and Recycling of Interfacial. Solar Steam Enthalpy

Model 3024 Albedometer. User s Manual 1165 NATIONAL DRIVE SACRAMENTO, CALIFORNIA WWW. ALLWEATHERINC. COM

Solar Flat Plate Thermal Collector

Performance Investigation of Cavity Absorber for Parabolic Dish Solar Concentrator

Effect of Humidity on Thermal Performances of a Non-evacuated Parabolic Trough Solar Collector

Experimental study on heat losses from external type receiver of a solar parabolic dish collector

MNFFY 221/SIF 4082 Energy and Environmental Physics. 2002

Pin Fin Lab Report Example. Names. ME331 Lab

1D and 3D Simulation. C. Hochenauer

Laser induced release of encapsulated noble gas in SCHOTT receiver

Optical analysis of low concentration evacuated tube solar collector

EXPERIMENTAL STUDY ON A CASCADED PCM STORAGE RECEIVER FOR PARABOLIC DISH COLLECTOR

Thermal Performance Analysis of Water Heating System for a Parabolic Solar Concentrator: An Experimental Model based design

Theoretical Analysis of Overall Heat Loss Coefficient in a Flat Plate Solar Collector with an In-Built Energy Storage Using a Phase Change Material

The Peak Flux Constraints on Bladed Receiver Performance in High- Temperature Molten Salt Concentrating Solar Power Systems

Simulation of the temperature distribution in automotive head lamps

Using sand and other small grained materials as heat storage medium in a packed bed HTTESS

Research Article Study on Effect of Number of Transparent Covers and Refractive Index on Performance of Solar Water Heater

Carbon dioxide as working fluid for medium and high-temperature concentrated solar thermal systems

Heriot-Watt University

ELEC9712 High Voltage Systems. 1.2 Heat transfer from electrical equipment

Overview of solar receiver design

Principles of Solar Thermal Conversion

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

Chapter 1 INTRODUCTION AND BASIC CONCEPTS

HELIOSTAT FIELD EFFICIENCY TEST OF BEAM DOWN CSP PILOT PLANT EXPEREMINATAL RESULTS

Heat Loss from Cavity Receiver for Solar Micro- Concentrating Collector

Design Optimisation of Compound Parabolic Concentrator (CPC) for Improved Performance M. M. Isa, R. Abd-Rahman, H. H. Goh

EFFECT OF NON-UNIFORM TEMPERATURE DISTRIBUTION ON SURFACE ABSORPTION RECEIVER IN PARABOLIC DISH SOLAR CONCENTRATOR

MODELING OPTIMIZATION OF FIXED ARBITRARY CONCENTRATORS

THE EFFECTS OF CALORIMETER TILT ON THE INWARD-FLOWING FRACTION OF ABSORBED SOLAR RADIATION IN A VENETIAN BLIND

Chapter 11. Energy in Thermal Processes

Experiment 1. Measurement of Thermal Conductivity of a Metal (Brass) Bar

Examination Heat Transfer

Autumn 2005 THERMODYNAMICS. Time: 3 Hours

Comparison of different composite Nd:YAG rods thermal properties under diode pumping

COMPARISON OF GUNN BELLANI RADIOMETER DATA WITH GLOBAL SOLAR RADIATION SENSOR (PYRANOMETER CM6B) Author. Mungai Peter N.

Optimizing Solar Thermal Power Plants: Influences on Parabolic Mirror Shape Accuracy

Topic 2: Heat Affects Matter in Different Ways

Experimental Studies of Active Temperature Control in Solid Breeder Blankets

PERFORMANCE OPTIMIZATION OF HYBRID SOLAR HEATING SYSTEM USING THERMOELECTRIC GENERATOR

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

11. Advanced Radiation

Performance Analysis of the Solar Linear Fresnel Reflector

NUMERICAL SIMULATION OF THE AIR FLOW AROUND THE ARRAYS OF SOLAR COLLECTORS

EXPERIMENTAL DETERMINATION OF SPECTRAL AND ANGULAR DEPENDENT OPTICAL PROPERTIES OF INSULATING GLASSES

Chapter 3: Fundamentals of Mechanics and Heat. 1/11/00 Electromechanical Dynamics 1

Scholars Research Library

Chapter 1: 20, 23, 35, 41, 68, 71, 76, 77, 80, 85, 90, 101, 103 and 104.

Chapter 3 NATURAL CONVECTION

Collector test according to EN ,2:2006

1 / 17. TÜV Rheinland (Shanghai) Co., Ltd Solar/ Fuelcell Technologies. Test Report

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 6, Issue 11, May 2017

INVESTIGATION ON CALIBRATION SYSTEM FOR CONDUCTIVE HEAT FLUX GAGES

ADVANCED ROOF COATINGS: MATERIALS AND THEIR APPLICATIONS

Lecture 28. Key words: Heat transfer, conduction, convection, radiation, furnace, heat transfer coefficient

Improvements of a Thermal Method for the Determination of Solar Absorptance and Thermal Emittance of Spacecraft Coatings

PERFORMANCE ANALYSIS OF PARABOLIC TROUGH COLLECTOR TUBE WITH INTERNAL INTERMITTENT FINS

An Air-Based Cavity-Receiver for Solar Trough Concentrators

Introduction to Heat and Mass Transfer. Week 5

Transcription:

THERMAL AND OPTICAL CHARACTERIZATION OF PARABOLIC TROUGH RECEIVERS AT DLR S QUARZ CENTER RECENT ADVANCES Johannes Pernpeintner 1, Björn Schiricke 2, Eckhard Lüpfert 2, Niels Lichtenthäler 2, Michael Anger 2, Philipp Ant 2, and Jan Weinhausen 2 1 Dipl.-Phys., Institute of Solar Research / DLR German Aerospace Center, Linder Höhe, 51147 Köln, Germany, Phone: +49 2203 601 3181, Fax: +49 2203 601 4141, Email: Johannes.Pernpeintner@dlr.de 2 Institute of Solar Research / DLR German Aerospace Center, Linder Höhe, 51147 Köln, Germany Abstract The performance of a parabolic trough receiver can be described by two parameters, the specific heat loss at operating temperature and the optical efficiency. DLR operates two test benches for the measurement of these parameters with high accuracy in its QUARZ Center. In the heat loss test bench THERMOREC the receiver is electrically heated to operating temperatures. In a steady state of constant heating power and absorber temperature an energy balance equation yields the thermal losses. Recent work was dedicated to the introduction of end heaters which lead to a significantly more even absorber temperature profile. Furthermore brass is now used for the homogenization tube with far reduced oxidation at the tube surface compared to the formerly used copper. In the ELLIREC, the linear focus test bench for the measurement of optical efficiency, the receiver is irradiated with solar simulator lamps. The enthalpy increase of cooling water flowing through the receiver at ambient temperature indicates the optical efficiency. The test bench has been characterized for reproducibility to 1 σ = 0.25% and homogeneity of the incident radiation in the linear focus to ± 5 % of the average. By comparison of the enthalpy increase to that of the defined reference receiver DLR 70-1 the relative optical efficiency is determined. Keywords: parabolic trough receiver, optical efficiency, thermal loss power, laboratory test bench 1. Introduction The receiver is a central part in every concentrated solar power plant. Due to the advanced market and nature of the technology, in large parabolic trough plants the receiver can be regarded a standardized product with defined dimensions and various available manufacturers. In DLR s QUARZ Center two laboratory test benches are operated to characterize the optical efficiency η opt,geo,rec and the heat loss power P th,loss, the two key parameters of parabolic trough receivers. The energy balance in a parabolic trough collector can be described [1] as P = P, (1) coll opt,geo,rec * Pin - th,loss where P coll is the enthalpy increase in the heat transfer fluid flowing through the receiver and P in is the power of the concentrated radiation intercepted by the receiver. The heat loss power P th,loss of a modern receiver with well evacuated annulus primarily depends on the absorber temperature T abs of the receiver, the emissivity of the absorber coating, and the tube diameter. The influence of ambient conditions like ambient wind speed and ambient temperature influence the heat loss only in the order of a few percent of the total heat loss [2]. The optical efficiency is dependent on transmittance τ of the glass envelope, absorptance of the absorber tube α, and the net area factor ψ. As the geometric effects at the bellows are included in the optical efficiency here, it is also called opto-geometric efficiency η opt,geo,rec. The optical efficiency can be expressed in a first approximation as a product η opt,geo,rec τ α ψ. A more accurate description includes effects of multiple reflections and incidence angle effects.

At DLR s QUARZ Center test benches for the measurement of both the opto-geometric efficiency and the heat loss are available. The measurement of both parameters is advisable, as the manufacturers can optimize one parameter at the expense of the other. This paper presents the current testing procedures of both test benches with an emphasis on recent developments. 2. Heat Loss Testing Heat loss testing of parabolic trough receivers has become a standard laboratory measurement technique. It is applied in measurement institutes like NREL, CENER and DLR but also in industry [3], [4]. A first round robin test for the comparison of test benches of three participating partners was performed in 2009; the results were presented at last years SolarPACES Conference [3] and showed a good agreement with maximal deviations of 10 %. In thermal loss testing the receiver is heated electrically to operating temperature. In the steady state of constant heating power and constant temperature the heating power minus parasitic losses indicate the heat loss of the receiver at the respective absorber temperature. For the electrical heating two methods are common. Either electrical heating elements are inserted into the absorber tube (often a homogenization tube of copper is used to even the temperature profile of the absorber in longitudinal and vertical direction), or heating is performed by direct joule heating of the steel absorber tube that functions as the resistor for the resistance heating. Temperature measurement of the absorber tube is usually performed by thermocouple measurement at the inside surface of the absorber tube. Sometimes absorber tube elongation is used for the temperature measurement, however the steel type and the respective heat expansion coefficient have to be known with sufficient accuracy [3]. The heating concept of the THERMOREC is shown in Figure 1. The bulk of the heating power is delivered by the main heater. It is 4060 mm in active length and provides constant heating power per unit length. It is surrounded by a homogenization tube (not shown in the figure) of copper or brass. While the heat conductivity of brass is lower than that of copper, the handling of brass is much easier as its tendency to oxidation at the surface is lower at typical testing temperatures of up to 400 C. At the ends thermal insulation minimizes thermal losses via the end faces. As these losses cannot be eliminated entirely by insulation, end heaters are used and controlled in order to achieve an even absorber temperature profile. Figure 1: Heating concept of THERMOREC with main heater, end heaters and thermal insulation, chosen system borders exclude bellow losses The energy balance equation in the steady state is P th, loss Pmain + Pend - = P ax,loss, (2) where P main is the electrical heating power of the main heater. P end is the power of the end heaters. Its contribution is typically < 5 % of the total heating power. P ax,loss is the loss power leaving the receiver via the thermal insulation. This correction is at the order of 2 % to 4 % of the overall heat loss. P ax,loss is calculated using the surface temperatures of the thermal insulation surfaces considering free convection and radiation. Typically bellow losses are excluded from heat loss measurement at the THERMOREC by insulating the bellow surface up to the glass-to-metal seal, as shown in Figure 1, however measurements can also be

performed with the original bellow insulation mounted. 16 internal type-n thermocouples are used which measure the temperatures of the absorber and homogenization tube. Thermocouples for the measurement of the absorber are mounted on the brass tube and pressed against the absorber inner surface with spring leafs. Thermocouples are mounted at multiple longitudinal positions and face directly up- and downward in order to measure the temperature of the absorber side facing up- and downwards. Hence the temperature is monitored in longitudinal and vertical direction. The mean temperature T m is calculated according to T m 4 = ΣT i 4 f i, where each measured temperature T i to the 4 th power is weighted with a corresponding factor f i that expresses the attributed fraction of the absorber surface f i = A i / A abs. The corresponding surface A i is typically half the circumference as there are thermocouples for the upper and the lower side of the absorber times the corresponding length, which is the sum of half the distances to both nearest neighbors. Currently the THERMOREC is operated by application of a constant heating power. After 5 to 8 hours depending on the heating power and the quality of the receiver - a quasi steady state is reached. It is planned to implement a PID-control-loop for faster operation in the future, however the current heating mode has the advantage, that for all thermocouples an exponential fit in the form of T(t) = T (1-exp(t/τ)) with the fitting parameters T and τ is possible, if the data range is properly chosen. T then yields a prediction for the steady state temperature and hence an assessment of the quality of the steady state and potential correction value. Typically T differs only 0.2 K from the measured mean absorber temperature after 5 to 8 hours. An error calculation of the absorber temperature measurement that includes the uncertainties of the thermocouple, the thermocouple data acquisition and the steady state quality yields an uncertainty of ± 1.3 K. However, a major uncertainty arises from the question of the quality of the thermal contact of the thermocouple to the absorber tube: As the thermocouple is situated between absorber tube and the homogenization tube, that is 10 40 K hotter than the absorber, it is unclear how well the thermocouple temperature is in agreement with the absorber tube temperature, which is actually intended to be measured. Although the thermocouple is pressed on the absorber by spring leafs, radiation from the homogenization tube and hot air from convection from the homogenization tube and heat conduction via spring leafs and thermocouple cables do also heat the thermocouple. Currently there is no good basis for an estimation of the additional uncertainty. The authors believe it could easily exceed the above stated uncertainty of the thermocouple measurement and hence dominate the overall uncertainty. Furthermore this effect leads to a systematical overestimation of the absorber temperature. The uncertainty in power measurement, including main heater power, end heater power and axial loss power has been calculated to ± 0.5 % at 800 W heating power. As the introduction of end heaters has been a recent change to the THERMOREC test bench, in Figure 2 example measurements of the absorber temperature profile are shown with and without activated end heaters. Although the end losses via the insulation amount for only 2 % to 4 % of the total heating power, a distinct temperature profile emerges, if only the main heater is used. At the temperature level of 300 C the temperature difference from center to the ends amounts to approximately 30 K. By using the end heaters the homogeneity is vastly improved. At a mean value of approximately 350 C deviations are in the order of ± 3 K. These deviations are dependent on the calibration of the thermocouples, the homogeneity of the pressing force of the spring leafs and the homogeneity of the absorber coating itself. Thermocouples with vastly reduced spring force or without any contact to the absorber at all can be detected by their significantly higher temperature levels and are excluded in the evaluation process.

Figure 2: Distribution of absorber temperature in longitudinal direction with and without end heaters 3. Optical Efficiency Testing 2.1. Experimental Setup The ELLIREC test bench is a solar simulator test bench for the optical characterization of linear focus receivers like parabolic trough receivers. Optical characterization is performed by measuring the enthalpy increase P coll (compare equation 1) of water at ambient temperatures through the receiver. Hence the optical properties are measured as the opto-geometric efficiency η opt,geo,rec, that combines glass transmittance τ, absorber absorptance α, and net area factor ψ [1],[5]. The linear focus is achieved by an elliptical cylinder reflector geometry with flat end mirrors, while the metal halide lamps at two positions and the receiver are situated in the respective focal lines, compare Figure 4. Typical measurement conditions are the operation of four lamps with 13 kw e in total, a volume flow of 0.850 m 3 / h, and a temperature increase of 3-4 K resulting in an enthalpy increase P coll = 4.5 kw. P coll is considered to be equal to the absorbed power as thermal losses are neglected. The Reynolds number is in the transitional range of 3000 4000. Figure 3: Geometry of the ELLIREC test bench: Elliptical trough with flat end mirrors. Length 5.0 m, semi-major axis 1.0 m, semi-minor axis 0.7 m. At the place of the receiver a flat target displaying the irradiance distribution in the focal line of the receiver is shown. For illustrative purposes the reflector is cut open, in reality the mirrors fully enclose lamps and receiver; Reproducibility of the enthalpy increase measurement has been investigated and was found to be ± 0.25 % (1 σ) as determined with 17 independent measurements. This figure includes stability of receiver mounting accuracy, radiant flux of the lamps, temperature and flow measurement, mirror shape accuracy, and cleaning over a period of few months. 2.2. Optical characterisation as relative measurement and definition of master standards According to Equation 1, the opto-geometric efficiency of the receiver at ambient temperature is defined as η opt,geo,rec = P coll / P in. Since the incident flux on the total receiver length P in is not exactly known for the test bench, the test bench is used for relative measurements of different receivers. As the measurement is performed at ambient temperatures, an analysis of the bellow design and a correction including the absorber expansion is necessary. In order to provide a long term stable absolute reference DLR has defined two

reference receivers DLR70_1 and DLR90_1 for the two receiver geometries of 70 mm and 89 mm diameter. As the used receivers are state of the art receivers, the measured enthalpy increase is multiplied by an anonymization factor. 2.3. Investigation of geometrical radiation distribution The flux distribution along the receiver length has to be homogenous, if the receiver aperture is to be included in the optical performance characterization. Applying the camera target method [6] the radiation distribution along the focal line was measured. The flat target was oriented as shown in Figure 4. Measurements confirmed the prior ray tracing simulations by showing a nearly flat distribution with about 10 % higher flux near the bellows. The width of the focus as measured on the target is in the order of 10 cm FWHM. In Figure 4 the flux distribution on the circumference of the receiver as simulated for the ELLIREC is compared to Eurotrough data showing a-one-lobe distribution instead of the two lobes at the Eurotrough. As typical parabolic trough receivers are nearly axi-symmetric and blocking elements like evacuation nipple or getters are turned to the 180 -position for the measurement, this is considered negligible. 5 Intensity in a.u. 4 3 2 1 Ellirec Eurotrough 0-180 -90 0 90 180 Angle in Figure 4: Simulated flux distribution on the circumference of the receiver in the ELLIREC test bench compared to Eurotrough data 5. Conclusion The two test benches for the measurement the specific heat loss at operating temperature and the characterization of the optical efficiency of parabolic-trough receivers have been qualified in detail. Both tests are in use for standardized measurements of such receivers from series production or new developments. The electrical heating with heater inserts in the heat loss test bench THERMOREC leads to very good accuracy of the power measurement and a relatively flexible testing. In a steady state of constant heating power and absorber temperature an energy balance equation yields the thermal losses. End heaters have been added, leading to a significantly more homogeneous absorber temperature profile in the tests. The test bench for the measurement of optical efficiency ELLIREC has been characterized for reproducibility to 1 σ = 0.25 % and homogeneity of receiver incident radiation to ± 5 % of the average. Test results from this optical test bench do not provide an absolute value. A standard reference test sample has been introduced that allows determination of results relative to the DLR 70-1 reference sample. References [1] E. Lüpfert, U. Hermann, H. Price, E. Zaraza, R. Kistner: Towards standard performance analysis for parabolic trough collector fields, (2004), Proceedings of SoarPACES Conference, Mexico, Oaxaca [2] F. Burkholder, C. Kutscher: Heat Loss Testing of Schott s 2008 PTR70 Parabolic Trough Receiver, National Renewable Energy Laboratory, Technical Report NREL/TP-550-45633 (2008) [3] P. Eichel, S. Dreyer, T. Gnaedig, Z. Hacker, S. Janker, Th. Kuckelkorn, K. Silmy, J. Pernpeintner, E. Lüpfert: Heat Loss Measurements on Parabolic Trough Receivers, (2010), Proceedings of SolarPACES Conference, France, Perpignan

[4] P. Garcia, M. Sanchez, E. Nateu, F. Villuendas, C. Heras, R. Alonso: Optical and Thermal Characterisation of Solar Receivers for Parabolic Trough Collectors, (2010), Proceedings of SolarPACES Confernce, France, Perpignan [5] J. Pernpeintner, B. Schiricke, E. Lüpfert, N. Lichtenthäler, M. Macke, K. Wiesemeyer: Combined Measurement of Thermal and Optical Properties of Receivers for Parabolic Trough Collectors, SolarPACES Conference, Germany, Berlin [6] E. Lüpfert, K. Pottler, S. Ulmer, K.-J. Riffelmann, A. Neumann, B. Schiricke: Parabolic Trough Optical Performance Analysis Techniques, (2007), Journal of Solar Energy Engineering, Vol. 129