Atomic and nuclear physics

Similar documents
Atomic and nuclear physics

Atomic and nuclear physics

Andrew D. Kent. 1 Introduction. p 1

Solid-state physics. Laue diagrams: investigating the lattice structure of monocrystals. LEYBOLD Physics Leaflets P

CASSY Lab. Manual ( )

Determination of the Rydberg constant, Moseley s law, and screening constant (Item No.: P )

Absorption of X-rays

This experiment is included in the XRP 4.0 X-ray solid state, XRS 4.0 X-ray structural analysis, and XRC 4.0 X-ray characteristics upgrade sets.

Bragg reflection :determining the lattice constants of monocrystals

TEP Examination of the structure of NaCl monocrystals with different orientations

Lab Manual: Determination of Planck s constant with x-rays

Characteristic X-rays of molybdenum

X-RAY SPECTRA. Theory:

Atomic and nuclear physics

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P

Physical structure of matter. Duane-Hunt displacement law and Planck's quantum of action X-ray Physics. What you need:

Physical Structure of Matter. K a doublet splitting of molybdenum X-rays / fine structure Physics of the Electron.

X-ray Absorption Spectroscopy

Electricity. Measuring the force on current-carrying conductors in a homogeneous magnetic field. LEYBOLD Physics Leaflets P


X-ray absorption. 4. Prove that / = f(z 3.12 ) applies.

X-ray Spectroscopy. Danny Bennett and Maeve Madigan. October 12, 2015

Mechanics. Determining the gravitational constant with the gravitation torsion balance after Cavendish. LEYBOLD Physics Leaflets P

X-ray spectroscopy: Experimental studies of Moseley s law (K-line x-ray fluorescence) and x-ray material s composition determination

Physics 476LW. Advanced Physics Laboratory - Franck Hertz

Atomic and Nuclear Physics

X-ray Spectroscopy. c David-Alexander Robinson & Pádraig Ó Conbhuí. 14th March 2011

X-ray fluorescence analysis - calibration of the X-ray energy detector

X-ray practical: Crystallography

Atomic and nuclear physics

X-Rays Edited 2/19/18 by DGH & Stephen Albright

TEP K and L edge absorption Moseley s law and the Rydberg constant

Atomic and Nuclear Physics

X-RAY SCATTERING AND MOSELEY S LAW. OBJECTIVE: To investigate Moseley s law using X-ray absorption and to observe X- ray scattering.

p tot Mechanics LD Physics Leaflets

X-Ray Emission and Absorption

Atomic Spectra HISTORY AND THEORY

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

LAB 01 X-RAY EMISSION & ABSORPTION

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Lab 5: Spectroscopy & the Hydrogen Atom Phy248 Spring 2009

UNIVERSITY OF SURREY DEPARTMENT OF PHYSICS. Level 1: Experiment 2F THE ABSORPTION, DIFFRACTION AND EMISSION OF X- RAY RADIATION

Experiment objectives: measure the ratio of Planck s constant to the electron charge h/e using the photoelectric effect.

Free fall with an interface system

print first name print last name print student id grade

PiCUS Calliper Version 3

Sample Alignment (2D detector) Part

Lab 10 Circular Motion and Centripetal Acceleration

MASS ATTENUATION COEFFICIENT OF LEAD

Measuring Planck s Constant By Martin Hackworth

Photoluminescence Spectrometer (FLS980)

PHYS 3650L - Modern Physics Laboratory

Alpha-Energies of different sources with Multi Channel Analyzer

Relativistic Electrons

THE NATURE OF THE ATOM. alpha particle source

Circular Motion and Centripetal Force

Beamline practice at BL01B1 (XAFS) In-situ XAFS measurement of catalyst samples

product manual H-3220A Benkelman Beam

!!!!! General!Physics!I!&!II!Lab!!! Course!Description!! Lab!Report!Template!and!Sample!! Grading!Rubrics! Pre>Lab!Quizzes!!!!!!!!

Experiment 6 1. The Compton Effect Physics 2150 Experiment No. 6 University of Colorado

Software BioScout-Calibrator June 2013

Alpha-energies of different sources with Multi Channel Analyzer (Item No.: P )

The Spectrophotometer and Atomic Spectra of Hydrogen Physics 246

TALLINN UNIVERSITY OF TECHNOLOGY, INSTITUTE OF PHYSICS 6. THE TEMPERATURE DEPENDANCE OF RESISTANCE

Diffractometer. Geometry Optics Detectors

Concentrations that absorb. Measuring percentage transmittance of solutions at different concentrations

Pracownia Podstaw Fizyczne Laboratorium Mikrokomputerowe Wydział Fizyki Eksperymentu Fizycznego Filami UAM. Radioactive decay

3B SCIENTIFIC PHYSICS

Rutherford experiment with MCA

Experiment 9. Emission Spectra. measure the emission spectrum of a source of light using the digital spectrometer.

Photoelectric Effect

Sample Alignment Part

Determining the Concentration of a Solution: Beer s Law

Coherence and width of spectral lines with Michelson interferometer

RADIOACTIVITY MATERIALS: PURPOSE: LEARNING OBJECTIVES: DISCUSSION:

THE GEIGER-MULLER TUBE AND THE STATISTICS OF RADIOACTIVITY

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

DAY LABORATORY EXERCISE: SPECTROSCOPY

Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008

PC1144 Physics IV. Atomic Spectra

Absorption of Gamma Rays

H2 Physics Set A Paper 3 H2 PHYSICS. Exam papers with worked solutions. (Selected from Top JC) SET A PAPER 3.


Physics 23 Fall 1989 Lab 5 - The Interaction of Gamma Rays with Matter

Spectrometer User s Guide

Higher -o-o-o- Past Paper questions o-o-o- 3.6 Radiation

Kinematics. Become comfortable with the data aquisition hardware and software used in the physics lab.

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Physics Department. Experiment 03: Work and Energy

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Higher Physics. Particles and Waves

Physics 476LW Advanced Physics Laboratory Michelson Interferometer

Title: ASML Stepper Semiconductor & Microsystems Fabrication Laboratory Revision: B Rev Date: 12/21/2010

Radioactivity INTRODUCTION. Natural Radiation in the Background. Radioactive Decay

Summer Research Final Report. Radiation Shielding - HEP Lab A - Florida Institute of Technology. Eric Hansen

Transpiration. Evaluation copy

Jasco V-670 absorption spectrometer

Nuclear Physics and Astrophysics

Nanoscale work function measurements by Scanning Tunneling Spectroscopy

Experiment C-10 Titration of a Strong Acid and a Strong Base

Transcription:

Atomic and nuclear physics X-ray physics Attenuation of x-rays LEYBOLD Physics Leaflets P6.3.2.2 Investigating the wavelength dependency of the coefficient of attenuation Objects of the experiment To measure the transmittance T of a copper foil and a zirconium foil for x-rays as a function of the wavelength between 30 and 120 pm. To investigate the wavelength-dependency of the attenuation coefficient outside of the absorption edges. To confirme the 3 law as a function of the absorption coefficient. Principles The attenuation of x-rays passing through matter is described by Lambert s law (see experiment P6.3.2.1): R = R 0 e x (I) Here, R 0 is the intensity of the x-ray radiation in front of the attenuator, R is the intensity behind the attenuator, is the linear attenuation coefficient and x is the thickness of the attenuator. Absorption and scattering both contribute to attenuation. The linear attenuation coefficient is thus composed of the linear absorption coefficient and the linear scattering coefficient. = + (II) These coefficients are proportional to the mass and the density of the irradiated material respectively. That is why we often use the so-called mass coefficients m =, m =, m = (III) or for the pure metals observed here the atomic coefficients or cross-sections A A A a = m, N a = m, A N a = m (IV) A N A A: atomic weight N A = 6.022 10 23 1 : Avogadro s number mol Analogously to equation (II), we can say that m = m + m (V) and a = a + a (VI) The absorption of x-rays is essentially due to the ionization of atoms, which release an electron from an inner shell. The absorption cross-section is thus strongly dependent on the quantum energy h resp. the wavelength of the x-ray radiation as well as on the excitation energy of the atoms and thus the atomic number Z. For ionization to occur, the quantum energy of the x-rays must be greater than the binding energy E of the electrons of the respective shell. The absorption cross-section is thus very small once the quantum energy is just slightly below the binding energy. The limit wavelength at which the quantum energy is just sufficient is called the absorption edge (see Fig. 1). Outside of the absorption edges, absorption is described to within a close approximation by the relationship a = C 3 Z 4 (VII). 0708-Ste Fig. 1 Absorption coefficient as a function of the x-ray wavelength (schematic) K: absorption edge of K shell L I, L II, L III : absorption edges of L shell 1

P6.3.2.2 LEYBOLD Physics Leaflets Apparatus 1 X-ray apparatus.............. 554 811 1 End-window counter for,, and x-ray radiation...... 559 01 1 Set of absorber foils........... 554 832 additionally required: 1 PC with Windows 95/98 or Windows NT This experiment verifies the dependence on the wavelength for two different metals, i.e. two different atomic numbers Z. The evaluation exploits the fact that the scattering cross-section a in the wavelength range = 35 100 pm is significantly less than the absorption cross-section and can be estimated approximately using a = 0.2 cm2 g A (VIII) N A By applying a series of transformations to equations (III)-(VII), we can calculate the absorption cross-section as: a = A 0.2 cm2 N A g A (IX) N A This experiment measures the transmittance T = R (X) R 0 of the transilluminated material as a function of the wavelength of the x-ray radiation. When we apply Lambert s law of attenuation T = e x (XI) we can calculate the linear attenuation coefficient and, using this value and equation (IX), the absorption cross-section a : a = ln T x A N A 0.2 cm2 g A N A (XII) Safety notes The x-ray apparatus fulfills all regulations governing an x-ray apparatus and fully protected device for instructional use and is type approved for school use in Germany (NW 807/97 Rö). The built-in protection and screening measures reduce the local dose rate outside of the x-ray apparatus to less than 1 Sv/h, a value which is on the order of magnitude of the natural background radiation. Before putting the x-ray apparatus into operation inspect it for damage and to make sure that the high voltage is shut off when the sliding doors are opened (see Instruction Sheet for x-ray apparatus). Keep the x-ray apparatus secure from access by unauthorized persons. Fig. 2 Diffraction of x-rays at a monocrystal and for 2 coupling between counter-tube angle and scattering angle (glancing angle) 1 collimator, 2 monocrystal, 3 counter tube Do not allow the anode of the x-ray tube Mo to overheat. When switching on the x-ray apparatus, check to make sure that the ventilator in the tube chamber is turning. The goniometer is positioned solely by electric stepper motors. Do not block the target arm and sensor arm of the goniometer and do not use force to move them. A goniometer with NaCl crystal and a Geiger-Müller counter tube in the Bragg configuration are used to record the intensities as a function of the wavelength. The crystal and counter tube are pivoted with respect to the incident x-ray beam in 2 coupling, i.e. the counter tube is turned at an angle twice as large as the crystal (see Fig. 2). In accordance with Bragg s law of reflection, the scattering angle in the first order of diffraction corresponds to the wavelength = 2 d sin (XIII) d = 282.01 pm: lattice plane spacing of NaCl 2

LEYBOLD Physics Leaflets P6.3.2.2 Setup Setup in Bragg configuration: Set up the experiment as shown in Fig. 3. To do this, proceed as follows (see also the Instruction Sheet for the x-ray apparatus): Mount the collimator in the collimator mount (a) (note the guide groove). Attach the goniometer to guide rods (d) so that the distance s 1 between the slit diaphragm of the collimator and the target arm is approx. 5 cm. Connect ribbon cable (c) for controlling the goniometer. Remove the protective cap of the end-window counter, place the end-window counter in sensor seat (e) and connect the counter tube cable to the socket marked GM TUBE. By moving the sensor holder (b), set the distance s 2 between the target arm and the slit diaphragm of the sensor receptor to approx. 5 cm. Mount the target holder with target stage. Loosen knurled screw (g), place the NaCl crystal flat on the target stage (f), carefully raise the target stage with crystal all the way to the stop and carefully tighten the knurled screw (prevent skewing of the crystal by applying a slight pressure). If necessary, adjust the mechanical zero position of the goniometer (see Instruction Sheet for x-ray apparatus). Notes: NaCl crystals are hygroscopic and extremely fragile. Store the crystals in a dry place; avoid mechanical stresses on the crystal; handle the crystal by the short faces only. If the counting rate is too low, you can reduce the distance s 2 between the target and the sensor somewhat. However, the distance should not be too small, as otherwise the angular resolution of the goniometer is no longer sufficient to separate the K and K lines. Preparing the PC-based measurement: Connect the RS 232 output and the serial interface on your PC (usually COM1 or COM2) using the 9-pin V24 cable (supplied with x-ray apparatus). If necessary, install the software X-ray Apparatus under Windows 95/98/NT (see Instruction Sheet for x-ray apparatus) and select the desired language. Fig. 3 Experiment for investigating the wavelength-dependency of the attenuation coefficient Carrying out the experiment Start the software X-ray Apparatus, check to make sure that the apparatus is connected correctly, and clear any existing measurement data using the button or the F4 key. Set the tube high voltage U = 30.0 kv, the emission current I = 1.00 ma and the angular step width = 0.1. At U = 30 kv, the limit wavelength of the bremsstrahlung radiation is min = 41.3 pm (see e.g. experiment P6.3.3.3). This value corresponds to a diffraction angle of 4.19 in the first order of diffraction and 8.42 in the second order of diffraction. Press the COUPLED key to activate 2 coupling of target and sensor and set the lower limit of the target angle to 4.2 and the upper limit to 8.3. Set the measuring time per angular step to t = 5 s. Start measurement and data transfer to the PC by pressing the SCAN key. Once the scan is complete, increase the measuring time to t = 10 s, mount the Cu foil from the set of absorbers (554 832) in the sensor seat (e) and start another measurement by pressing SCAN. Then replace the Cu foil with a Zr foil and run a third measurement. When you have finished measuring, save the measurement series under an appropriate name by pressing the button or the F2 key. To display the measurement data as a function of the wavelength, open the Settings dialog with the button or F5, and in the tab Crystal, click on the button Enter NaCl. 3

P6.3.2.2 LEYBOLD Physics Leaflets Fig. 4 Diffraction spectra of x-rays with the characteristic lines of the molybdenum anode in the wavelength range between 40 and 80 pm (U = 30 kv) Squares: not attenuated Triangles: attenuated with copper foil Circles: attenuated with zirconium foil Fig. 5 Transmittance T in the wavelength range between 40 and 80 pm Triangles: attenuated with copper foil Circles: attenuated with zirconium foil 4

LEYBOLD Physics Leaflets P6.3.2.2 Measuring example See Fig. 4 Evaluation a) Calculating the transmittance T: In the software X-ray Apparatus, click on the Transmission tab and, using the diffraction spectra (see Fig. 4), generate the transmission spectra for copper and zircon foil (see Fig. 5). b) Calculating the absorber cross-section a : To copy data to the Clipboard, position the pointer over the table, click the right mouse button and select the menu command Copy Table. Paste the data from the Clipboard, with the three columns, T(Cu) and T(Zr), into a suitable evaluation program (e.g. a spreadsheet). Calculate the absorption cross-section a for the two foils with equation (XII) using the parameters compiled in table 1 (see Fig. 6). Tab. 1: Parameters of the foils Element Z g cm 3 x cm A g mol 1 Cu 29 8.92 0.007 63.55 Zr 40 6.49 0.005 91.22 c) Verifying the 3 law: Calculate the terms ln ( a /10 24 cm 2 ) and ln (_/pm) and display the wavelength dependency of the absorption cross-section in the representation ln a = f (ln ) (see Fig. 7). Fit straight lines to the diagram at suitable intervals. Results The atomic absorption cross-section of copper increases consistently in the wavelength range between 40 and 80 pm. Zirconium, on the other hand, shows an abrupt change of the absorption cross-section (absorption edge of K-shell). In practice, this property is used for approximately monochromatizing the x-ray output of a molybdenum anode, i.e. to substantially suppress the spectrum of bremsstrahlung and the K line (see Fig. 4). At suitable intervals outside of the absorption edges, the absorption cross-section can be represented in the form ln a = A ln + B The slope of the line A has roughly the value 3, so that the 3 law approximately applies: Outside of the absorption edges the wavelength-dependency of the atomic absorption cross-section is approximately described by the relationship a = C 1 3 Fig. 6 Absorption cross-section a in the wavelength range between 40 and 80 pm Triangles: copper (Cu) Circles: zirconium (Zr) Fig. 7 Absorption cross-section a shows as ln a as a function of. Triangles: copper (Cu) Circles: zirconium (Zr) Lines: best-fit straight lines Slope of line: 2.7 (Cu) and 2.5 (Zr) τ a 10-24 cm 2 10000 5000 0 40 50 60 70 80 λ pm LEYBOLD DIDACTIC GMBH Leyboldstrasse 1 D-50354 Hürth Phone (02233) 604-0 Telefax (02233) 604-222 Telex 17 223 332 LHPCGN D by Leybold Didactic GmbH Printed in the Federal Republic of Germany Technical alterations reserved