Discharge Coefficient Behaviour in Presence of Four Perforated Plates Flow Conditioners

Similar documents
Discharge coefficient behaviour in presence of four perforated plates flow conditioners - Numerical investigation Part 1-

EXPERIMENTAL INVESTIGATION OF THE INSTALLATION EFFECTS ON THE VENTURI FLOWMETER PERFORMANCE

The Expansibility Factor Equations in ISO and ISO : Do They Deliver What They Promise?

NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In. St Andrews, Scotland

ABSTRACT I. INTRODUCTION

QUALIFICATION OF FLOW CONDTIONING DEVICES ACCORDING TO THE NEW API 14.3 PART 2 PROCEDURE. Klaus J. Zanker and Dale Goodson. Daniel Industries, Inc.

Prediction of Performance Characteristics of Orifice Plate Assembly for Non-Standard Conditions Using CFD

Lecture23. Flowmeter Design.

Discharge Coefficient Prediction for Multi hole Orifice Plate in a Turbulent Flow through Pipe: Experimental and Numerical Investigation

Flow Measurement in Pipes and Ducts COURSE CONTENT

[Prasanna m a*et al., 5(6): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

FINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT. FINAL DRAFT: October 25, 2010 Page 0

Process Gas Flow Measurement and Performance Evaluation API TECHNICAL REPORT 2571 SECOND EDITION DRAFT, FEBRUARY 2018

Smart DP Flow Metering A summary of Established Technology and Latest Innovation. Gary Fish

NUMERICAL EVALUATION OF DISTORTED VELOCITY PROFILE EFFECTS ON INSERTION FLOW METERS

Lecture 13 Flow Measurement in Pipes. I. Introduction

Installation effects on an ultrasonic flow meter with implications for self diagnostics

Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras

Analysis of the possibility to optimize the passive pressure pulsations dampers using CFD

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH

ME332 FLUID MECHANICS LABORATORY (PART I)

Head loss coefficient through sharp-edged orifices

NUMERICAL ANALISYS OF FLOW CONDITIONER EFFICIENCY

Predictionof discharge coefficient of Venturimeter at low Reynolds numbers by analytical and CFD Method

Alden Test Results On AMITY Insert Venturi

ABSTRACT I. INTRODUCTION

Wall Pressure Due to Turbulent Flow Through Orifice Plate

Hydraulics and hydrology

Decay of Rotational Airflow with Flow Conditioner in Larger Diameter Ducts for Dust Concentration Measurement using Isokinetic Sampling

FLOW DISTRIBUTION ANALYSIS IN A HEAT EXCHANGER WITH DIFFERENT HEADER CONFIGURATIONS

Conditioning of swirling and stratified pipe-flow: Analysis with laser-doppler velocimetry

Laboratory work No 2: Calibration of Orifice Flow Meter

Experiment No.4: Flow through Venturi meter. Background and Theory

ISO 9906 INTERNATIONAL STANDARD. Rotodynamic pumps Hydraulic performance acceptance tests Grades 1 and 2

CVE 372 HYDROMECHANICS EXERCISE PROBLEMS

EXPERIMENT No.1 FLOW MEASUREMENT BY ORIFICEMETER

AN 8-PATH ULTRASONIC MASTER METER FOR OIL CUSTODY TRANSFERS

TransCanada / Daniel Using Advances Diagnostics to Identify Measurement Uncertainties

Experiment (4): Flow measurement

FACULTY OF CHEMICAL & ENERGY ENGINEERING FLUID MECHANICS LABORATORY TITLE OF EXPERIMENT: MINOR LOSSES IN PIPE (E4)

Comparison between Numerical and Experimental for UVP Measurement in Double Bent Pipe with Out-of-Plane Angle

Numerical Methods Applied to Fluid Flow Metering. Ernst von Lavante University of Duisburg-Essen

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

FLOW MEASUREMENT IN PIPES EXPERIMENT

Orifice and Venturi Pipe Flow Meters

[Ramya, 4 (12): December, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

CHAPTER THREE FLUID MECHANICS

INTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Orifice and Venturi Pipe Flow Meters

ERRATA CRANE FLOW OF FLUIDS THROUGH VALVES, FITTINGS AND PIPE TECHNICAL PAPER NO. 410 METRIC VERSION

Water Circuit Lab. The pressure drop along a straight pipe segment can be calculated using the following set of equations:

POWER UNDERSTANDING MEASUREMENT UNCERTAINTY IN DP FLOW DEVICES

DISCHARGE COEFFICIENT OF SMALL SONIC NOZZLES

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

EXPERIMENTAL INVESTIGATION OF THE HEAT TRANSFER IN A HORIZONTAL MINI-TUBE WITH THREE DIFFERENT INLET CONFIGURATIONS

PRESSURE DROP OF FLOW THROUGH PERFORATED PLATES

Fluid flow simulation in a double L-bend pipe with small nozzle outlets

1-Reynold s Experiment

Experimental Investigations on the Local Distribution of wall static pressure coefficient Due To an Impinging Slot Air Jet on a Confined Rough Surface

CHAPTER (13) FLOW MEASUREMENTS

Measurement of fluid flow in closed conduits

Applied Fluid Mechanics

Applied Fluid Mechanics

Lecture 24. Design of flow meters

Chapter 6. Losses due to Fluid Friction

Experimental and CFD analysis of flow through venturimeter to determine the coefficient of discharge

Major and Minor Losses

VENTURIMETER EXPERIMENT

Basic Fluid Mechanics

Lesson 6 Review of fundamentals: Fluid flow

Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals

APPLIED FLUID DYNAMICS HANDBOOK

An Essential Requirement in CV Based Industrial Appliances.

Flow analysis in centrifugal compressor vaneless diffusers

Piping Systems and Flow Analysis (Chapter 3)

An Experimental Investigation to Control the Flow Emerging From a Wide Angle Diffuser

Bounding the Uncertainties of the Meter Factors for LEFM CheckPlus Flow Elements in Feedwater Flow Measurements

The effect of geometric parameters on the head loss factor in headers

Qsl < > ARNOLD ENGINEERING DEVELOPMENT CENTER

Keywords - Gas Turbine, Exhaust Diffuser, Annular Diffuser, CFD, Numerical Simulations.

DESIGN AND PERFORMANCE OF THE CONVERGING-DIVERGING VORTEX FLOWMETER

EVALUATION OF FOUR TURBULENCE MODELS IN THE INTERACTION OF MULTI BURNERS SWIRLING FLOWS

REPORT OF SPECIAL TEST

INDUSTRIAL APPLICATION EXPERIENCES OF NEW TYPE FLOW- METERING SYSTEM BASED ON ULTRASONIC-DOPPLER FLOW VELOCITY-PROFILE MEASUREMENT

CHARACTERISTICS OF DISCHARGE COEFFICIENT IN INDUSTRIAL BURNER APPLICATIONS

NUMERICAL ANALYSIS OF INSTALLATION EFFECTS IN CORIOLIS FLOWMETERS: SINGLE AND TWIN TUBE CONFIGURATIONS

MCE380: Measurements and Instrumentation Lab

The Mechatronics Design for Measuring Fluid Friction Losses in Pipe Flows Rıza Gurbuz

ENHANCED HEAT TRANSFER CHARACTERISTICS OF CONJUGATED AIR JET IMPINGEMENT ON A FINNED HEAT SINK

VELOCITY PROFILE EFFECTS IN CORIOLIS MASS FLOWMETERS: RECENT FINDINGS AND OPEN QUESTIONS

CFD Analysis of Forced Convection Flow and Heat Transfer in Semi-Circular Cross-Sectioned Micro-Channel

ENHANCED HEAT TRANSFER CHARACTERISTICS OF CONJUGATED AIR JET IMPINGEMENT ON A FINNED HEAT SINK

Throttling Characteristics of Multi-Hole Orifice in Multi Stage Assembly

Lab Section Date. ME4751 Air Flow Rate Measurement

CFD Analysis for Thermal Behavior of Turbulent Channel Flow of Different Geometry of Bottom Plate

CHAPTER 3 BASIC EQUATIONS IN FLUID MECHANICS NOOR ALIZA AHMAD

CFD study of gas mixing efficiency and comparisons with experimental data

Proceedings of Meetings on Acoustics

Transcription:

Proceedings of the 4 th International Conference of Fluid Flow, Heat and Mass Transfer (FFHMT'17) Toronto, Canada August 21 23, 2017 Paper No. 183 DOI: 10.11159/ffhmt17.183 Discharge Coefficient Behaviour in Presence of Four Perforated Plates Flow Conditioners Laribi Boualem 1, Abdellah Hadj Abdellah 2 1 University Djillali Bounaama de Khemis Miliana Route de Theniet El Had, Khemis Miliana, Algeria b.laribi@univ-dbkm.dz 2 University Feres Yahia de Medea LMP2M Laboratory, Medea, Algeria lmp2m_cum@yahoo.fr Abstract - This paper present a numerical experimentation of the behaviour of the discharge coefficient and the effect of four perforated plates like flow conditioners on the discharge coefficient for flow measurement accuracy. Three of the plates are described by the Standard ISO5167 and the fourth one is proposed for study. The flow is subject to two disturbers namely 50% closed valve and 90 double bend in perpendicular planes. The turbulent flow is examined in conduit with an inner diameter of D=100mm. The diameter of orifice meters are respectively d=50, 60, 70 and 75mm which done for β ratio d/d respectively the values of 0.5, 0.6, 0.7 and 0.75. The orifice meters are located in conduit at different stations z/d downstream the disturbers. The flow is examined with air at Reynolds number Re=2.5x10 5. The results showed that the perforated plates have significantly reduced the error on the discharge coefficient. Indeed, the errors recorded downstream disturbers are superior to 12%. Downstream the perforated plates used separately the errors on the discharge coefficient are reduced to a value inferior to 1% for the four plates. It is noted that the standards ISO5167 and AGA3 stipulate that the error on the discharge coefficient Cd must be less than 0.5% for better flow measurement accuracy. By comparing our results with this condition we found that the error obtained on the discharge coefficient with the four perforated plates are substantially reduced especially downstream station z=25d (z =19D downstream disturbers). However the fourth proposed plate with its height porosity produces less lose pressure than those of the other three plates. This is good conditions of exploitation for some installation where height lose pressure are not tolerated. Keywords: Perforated plates flow conditioners, flowmetring, discharge coefficient. 1. Introduction The majority of the orifice meters must be calibrated. This is done in fully developed pipe flow, axisymmetric pipe that is free from swirl and pulsation. Standards such as ISO5167 [1] define a satisfactory flow. While high accuracy about 0.5% flow rate measurement is required, disturbances in the flow caused by valves, bends, and other component introduce errors of more than 3%. Given that most industrial installations include disturbers like bends, valves, expanders and reducers, which are sources of swirl, asymmetries and turbulence distortions, insuring that fully developed flow in terms of mean flow and turbulence structure approach the meter is difficult to achieve in practical situations. For best accuracy, a flow meter needs to be presented with an axisymmetric, fully developed velocity profile with zero swirls. Either very long lengths of straight pipe work upstream of the flow meter must be provided as recommended by standards ISO 5167 and AGA-3 [2], these may need to be of the order of 80 to 100 pipe diameters, which will give a higher installation cost and greater space requirement. Research work by Gallagher J. [2], T.T. Yeh and G. Mattingly [3], Laribi B. and al [4-7], R. Rans [8], Darin L. and Bowles E. B. [9], F. Sharipov [10] and more recently Laribi B. and al [11] have reported a number of computational studies of installation effects on orifice meter performances. Our paper examines the effect of for perforated plates with orifice meters on the shift deviation of the discharge coefficient for best metrological performances basing on the pressure drop across the orifice in non-standard conditions. 183-1

The investigation is conducted to show the effect of the two disturbers namely a 90 double bends in perpendicular planes and a 50% closed valve on the deviation of the discharge coefficient. 2. Turbulence Models The general equation used in CFD code is given by Eq. 1 as bellow: (1) Where: a general variable which can be velocity U (m.s -1 ), turbulence kinetic energy k (kg.m -2.s -2 ) or the dissipation rate (m -2.s -3 ). is the density of fluid (kg.m -3 ). Γ is the diffusion coefficient of the variable. S is the source term of the variable. The turbulence model used for this simulation is k-ε model. It is the simplest and complete model known as two equations. This model assumes that the turbulent regime is fully established throughout the area and that the effects of molecular viscosity are negligible compared to the turbulent viscosity (away from walls). It is based on the Boussinesq hypothesis. It is a semi-empirical model. Two transport equations are used, one for the turbulence kinetic energy k and the other for its dissipation rate ε. The reader can consult the literature Fluent [12] for thorough study. 3. Experimental Facility for the Simulation 3.1. Air Flow Rig The basic experimental facility is presented in figure 1. It consists of a long conduit pipe with 100 mm inner diameter. The air enters the pipe then flows through a straight pipe of 10D length, which is followed by disturbers. The 90 double bend in perpendicular planes and 50% closed valve were used separately. The orifice meter diameters used in this simulation are respectively d= 50, 60, 70 and 75mm diameters which done for ratio d/d respectively the values of 0.5, 0.6, 0.7 and 0.75. The first orifice meter is installed at 97D downstream of the flow disturber, where the flow is fully developed. Stations used for the second orifice meters are respectively 1.5D, 7D, 12D, 17.5D, 25D, 35D downstream the disturber. The two orifice meters have standard geometry. A length of 10D is provided downstream the entrance of flow and downstream the orifice meter installed at station 91D for natural flow development. The Reynolds number of the turbulent flow is 2.5x10 5. Fig. 1: Conduit. 3.2. Perforated Plates used in simulation The three perforated plates flow conditioners (F.C.) used in the study and described by the Standard ISO5167 are shown in figure 2. The forth one is our proposed plate. 183-2

Fig. 2: The four perforated plates. 3.3. Variation of the Discharge Coefficient For testing the effect of disturbers on the discharge coefficients of the orifice meters, the shift deviation for the discharge coefficient by the simulation at different locatio z/d=97 were the flow is fully developed. Eq. 2 shows the calculus formula: (2) The difference pressure is calculated according to the standard ISO 5167 at D upstream and D/2 downstream the orifice meter. This formula was applied for the four orifice plates with the two disturbers. 4. Results and Discussion 4.1. Discharge Coefficient Errors with 50% Closed Valve on Line and Perforated Plates Experiments were conducted to determine the relative change in the orifice meter discharge coefficient when subjected to non-standard approaching flow conditions like 50% closed valve. The test sections were 1.5D, 7D, 12D, 17.5D, 25D, 35D downstream the valve. The effect of valve on the orifice meter with the four orifice meters with = 0.50, 0.60, 0.70 and 0.75 respectively at Reynolds number of 2.5x10 5 is shown in figure 3. The principal remark shown in this figure is that at station z/d=1.5 when increases, Cd (%) increases. This situation is the same in presence of the four perforated plates used in this numerical study. Indeed, we register at station z/d=7 a value close to zero for Cd (%) with =0.5 with the NOVA F.C. This value increases to reach a mean value more than 3% for =0.75 with the other flow conditioners. We have to remember that the Standard ISO 5167 recommend a maximum value for Cd (%) of 0.5%. Our results are in good agreement with the standard for station z/d=17.5 and more for the four flow conditioners. This result let s suppose that if we would like to get a good flow measurement, the orifice meter must be placed at station z/d=25 or more downstream the valve. 183-3

Fig. 3: Discharge coefficient errors for the four F. C. with valve 50% closed. 4.2. Discharge Coefficient Errors with Double Bend on Line In this case, experiments were conducted to determine the relative change in the orifice meter discharge coefficient when subjected to 90 double bend in perpendicular planes. The test sections were 1.5D, 7D, 12D, 17.5D, 25D, 35D downstream the double bend. The effect of this disturbers on the orifice meter with the four orifice meters with = 0.50, 0.60, 0.70 and 0.75 respectively with a Reynolds number of 2.5x10 5 is shown in figure 4. The principal remark shown in this figure is the same which obtained with the valve. Indeed, when increases, Cd (%) increases especially at station z/d=7. This situation is the same for the four perforated plates used in this study. We register at station z/d=7 a value close to 0.3% for Cd (%) with =0.5 with NOVA F.C. and reach a mean value 2.7% for =0.75 for the NEL F.C. Our results are in good agreement with the standard for station z/d=25 and more. This result is the same of results obtained for the valve. 183-4

Fig. 4: Discharge coefficient errors with double bend 90o on line. 5. Conclusion The present numerical investigation examines the effect of upstream conditions on orifice meters otherwise on the discharge coefficient Cd. The flow is disturbed by a 50% closed valve and a 90 double bend in perpendicular planes used separately. The discharge coefficient were measured with four different orifice meters with =0.5, 0.6, 0.70 and 0.75 at Reynolds number Re=2.5x10 5. The principal result shows that when increases the shift deviation on the discharge coefficient Cd (%) increases. This result is the same with the two disturbers. Indeed if we would like to get a good flow measurement, the flow meter must be located at distance z/d=25 downstream the disturber or more. In this situation, a good agreement is obtained with the standards ISO 5167. We also concluded that the valve 50% closed could be considered for further experimental investig double bend in perpendicular planes which gave minimum errors (minimum disturbances) on the discharge coefficient contrary to the valve. At last, the CFD shows their efficiency to predict the flow behaviour in different situations and let us to plain our experimental study in optimal conditions in order to validate the numerical investigations. 183-5

Acknowledgements This study is a part of a research project approved by the Algerian Ministry of Higher Education and Scientific Research under number J0303920130026. The authors acknowledge the High Ministry of Education and Scientific Research of Algeria for supporting financially this project. References [1] ISO 5167, 2003, Measurement of fluid flow by means of orifice plates nozzles and ventury tubes inserted in circular cross section conduits running fuel, [Online]. Available: http://www.iso.org/iso/ [2] AGA-3, 1980, Orifice Metering of Natural Gas and the Related Hydrocarbone Fuels, [Online]. Available: http://www.aga.org [3] T. T. Yeh and G. Mattingly, 1996. E, Flow meter installation effects due to a generic header. NIST Technical note 1419. [Online]. Available: http://catalogue.nla.gov.au/ [4] B. Laribi, P. Wauters and M. Aichouni, Experimental Study of the Decay of Swirling Turbulent Pipe Flow and its Effect on Orifice Flow Meter Performance, ASME Fluids Engineering Division Summer Meeting, FEDSM'01, 2001. [5] B. Laribi, P. Wauters and M. Aichouni, Comparative study of aerodynamic behaviour of three flow conditioners, European Journal of Mechanical and Environmental Engineering, vol. 48, no. 1, pp. 21-30, 2003. [6] B. Laribi, et al, Numerical investigation of contribution of three flow conditioners in the development and establishment of turbulent flows, in Proceedings of ASME 2010 3rd joint USEuropean Fluids Engineering Summer Meeting, and 8th International Conference on Nanochannels, Microchannels and Minichannels, FEDSM2010- ICNMM2010, Canada, 2010. [7] B. Laribi and al, Numerical investigation of turbulent models in the development and establishment of turbulent flows with flow conditioners, in Proceedings of ASME 2010 3rd joint US-European Fluids Engineering Summer Meeting, and 8th International Conference on Nanochannels, Microchannels and Minichannels, FEDSM2010- ICNMM2010, Montreal, Canada, 2010. [8] R. Rans, et al, Flow Conditioning and Effects on Accuracy for Fluid measurement, 7th East Asia Hydrocarbon Flow Measurement Workshop 5th 7th, Malaysia, 2008. [9] L. Darin & E. B. Bowles, Conditioning on Gas Measurement, Pipeline & Gas Journal, pp. 59-62, 2008. [10] F. Sharipov, Numerical simulation of rarefied gas flow through a thin orifice, J. of Fluids Mechanics, vol. 518, pp. 35-60, 2004. [11] B. Laribi and A. Ait-Amrane, Numerical analysis of the discharge coefficient with disturbers for flowmetring accuracy on flow measurement, 16th International Metrology Congress Paris, 2013. [12] Fluent v6.3, Fluent incorporated, Journal Centerra source park, USA, 2006. 183-6