High Pressure DSC Differential Scanning Calorimeter

Similar documents
DSC PT 10. Applications

TGA Thermal Gravimetric Analysis

THERMO- GRAVIMETRIC ANALYZER TGA 1000

LASER FLASH ANALYSIS LFA 1000

LIGHT FLASH ANALYSIS LFA 500

Thermal Analysis Premium

SIMULTANEOUS THERMAL ANALYSIS STA PT 1000 STA PT 1600 STA HP

LSR SEEBECK COEFFICIENT ELECTRIC RESISTANCE ZT-MEASUREMENT NEW. Exciting new features including Harman measurements and Impedance Spectroscopy

Thermal Methods of Analysis Theory, General Techniques and Applications. Prof. Tarek A. Fayed

DSC AND TG/DTA AS PROBLEM-SOLVING TOOLS: CHARACTERIZATION OF PHARMACEUTICAL COMPOUNDS

Calorimetry: differential scanning calorimetry (DSC), isothermal titration calorimetry (ITC)

Chapter 31. Thermal Methods

Couplings / Gas Analysis

C80. Calvet Calorimeter From ambient to 300 C. A trademark of KEP Technologies group

CHEM*3440. Thermal Methods. Thermogravimetry. Instrumental Components. Chemical Instrumentation. Thermal Analysis. Topic 14

Thermal Methods of Analysis

Nutshells of Thermal Analysis. Heat it up! Burn it! Thermal Analysis

PCM specific heat capacity c p (T) measurements

Modulated DSC Paper #8 Use Of Quasi-isothermal Mode for Improved Understanding of Structure Change

Differential Scanning Calorimetry

APPLICATION NOTE. Characterization and Classification of Recycled Polyamides by Means of Identify. Dr. Ekkehard Füglein

Thermal Analysis Excellence

Analyzing & Testing. Simultaneous Thermal Analysis. Method, Technique, Applications STA 449 F3. Leading Thermal Analysis

Analyzing & Testing Business Unit. Tau-R Mode for Advanced DSC Analysis Applications Newsletter 1/ /09, Dr. Stefan Schmölzer

TAWN tests for quantitatively measuring the resolution and sensitivity of DSCs (version 2.1)

Universal Standard Protocols for Temperature and Material Characterization Calibration with Pharmaceuticals by Thermal Analysis

Analyzing & Testing. Comprehensive Material Characterization. Leading Thermal Analysis

Characterization of Solid State Drugs by Calorimetry

Analyzing & Testing. Photocalorimetry Photo-DSC. Method, Technique, Applications. Photo-DSC 204 F1. Leading Thermal Analysis

Heat Transfer in Polymers

DSC Methods to Quantify Physical Aging and Mobility in Amorphous Systems: Assessing Molecular Mobility

Comprehensive Handbook of Calorimetry and Thermal Analysis

Common Definition of Thermal Analysis

A NEW MEASUREMENT AND EVALUATION METHOD FOR DSC OF PCM SAMPLES

Thermal Analysis Excellence

TOPEM the new advanced multi-frequency TMDSC technique

APPLICATIONS OF THERMAL ANALYSIS IN POLYMER AND COMPOSITES CHARACTERIZATION. Wei Xie TA Instruments

Hiden Isochema. Gravimetric Gas & Vapor Sorption Analyzers. Hiden Isochema IGA Series. Advancing Sorption Analysis

States of matter Part 2

Thermal Analysis measurements

Thermal and UV-curing Behavior of Inks, Adhesives, and Coatings by Photo-, In-situ DEA and DMA.

News & Trends for Thermal Analysis

FORCE TENSIOMETER K100 THE HIGH-END SOLUTION FOR MEASURING SURFACE AND INTERFACIAL TENSION

DEVELOPMENT OF IMPROVED METHODS FOR CHARACTERISING THE CURE OF COMPOSITE MATERIALS

INTERNATIONAL STANDARD

SILMALAB is a laboratory of analysis for plastics industry that takes advantage of the experience gained by our engineers in 30 years of work and

Thermal Safety Software (TSS) series

Automated multi-vapor gravimetric sorption analyzer for advanced research applications

Calorimetric Principles and TAM III

How to Use Kinetic Modeling Analysis To Predict Profile Part Failure

DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS.

Uncover the insight with Hyphenation. Gerlinde Wita October 2015

How fast are chemical reactions?

IMPROVED ADIABATIC CALORIMETRY IN THE PHI-TEC APPARATUS USING AUTOMATED ON-LINE HEAT LOSS COMPENSATION

The THT micro reaction calorimeter μrc

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

ISO INTERNATIONAL STANDARD. Plastics Differential scanning calorimetry (DSC) Part 4: Determination of specific heat capacity

Chem Page IX - 1 LAB MANUAL Differential Scanning Calorimetry 09_dsc131.docx EXPERIMENT IX

Thermochimica Acta 531 (2012) Contents lists available at SciVerse ScienceDirect. Thermochimica Acta

The THT micro reaction calorimeter RC

Measurement of heat transfer coefficients for polymer processing simulation

A.2. BOILING TEMPERATURE

Major Concepts Calorimetry (from last time)

Thermal methods. P A Sathe Ramnarain Ruia College, Mumbai

UNIT 11 DIFFERENTIAL THERMAL ANALYSIS, SCANNING CALORIMETRY AND THERMOMETRIC TITRATIONS

Thermogravimetric Analysis Advanced Techniques for Better Materials Characterisation

DSC AS PROBLEM-SOLVING TOOL: BETTER INTERPRETATION OF Tg USING CYCLIC DSC

Thermochemistry/Calorimetry. Determination of the enthalpy of vaporization of liquids LEC 02. What you need: What you can learn about

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FTIR

Analyzing & Testing. Thermogravimetric Analysis TGA. Technique, Instrument, Applications TG 209 F1. Leading Thermal Analysis

Products & Applications VESTASOL. Specialty Solvents & Intermediates

Differential Scanning Calorimetry

INFLUENCES OF SALT HYDRATE MIXTURES AND PORE SIZES ON THE SORPTION HEAT OF COMPOSITE TES MATERIALS. K. Posern, Ch. Kaps

Calorimetry. Chapter 2. Differential Scanning heat flux calorimetry

1) INTRODUCTION 2) ROLE IN PREFORMULATION 3) CLASSIFICATION OF THERMAL ANALYSIS. 4) DIFFERENT METHODS OF THERMAL ANALYSIS.

HFM 100 Series. Thermal Conductivity Meter for measurement of insulation and construction materials.

Total analysis with DSC, TMA and TGA-EGA

FORCE TENSIOMETER K100 THE HIGH-END SOLUTION FOR MEASURING SURFACE AND INTERFACIAL TENSION

A Thermal Analysis Technique That Combines Differential Scanning Calorimetry and Light Microscopy

6.5 Optical-Coating-Deposition Technologies

Unit 4: Gas Laws. Matter and Phase Changes

Application Handbook. Thermal Analysis in Practice Collected Applications

Differential Scanning Calorimeter Analysis of Hydrino-Producing Solid Fuel

Thermal Analysis. Short Courses POLYCHAR 25 Kuala Lumpur. Copyright 2017 by Jean-Marc Saiter

Measuring the Reaction Kinetics of Polyester/PCA-501(HAA) Powder Coatings With Dielectric Analysis (DEA)

DVS Intrinsic Compact and Economical Dynamic Vapor Sorption System

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

FUNDAMENTALS OF THERMAL ANALYSIS AND DIFFERENTIAL SCANNING CALORIMETRY Application in Materials Science Investigations

Humidity Calibration Solutions

Thermal analysis unlocks the secrets of elastomers

RH7-D & RH10-D CAPILLARY RHEOMETERS

Design, Testing and Pharmaceutical Applications of a Gas Pressure Controller Device for Solid - Gas Microcalorimetric Titration

T h e r m a l a n a l y s i s a n d c a l o r i m e t r y s o l u t i o n s

Melting and solidi cation of Pb nanoparticles embedded in an Al matrix as studied by temperature-modulated di erential scanning calorimetry

Applications Note 164 October 2007

Defining quality standards for the analysis of solid samples

APPLICATION NOTE. Investigation of Alkali Salts with the STA 449 F5 Jupiter. Dr. Alexander Schindler and Dr. Michael Schöneich.

CHEMISTRY Topic #2: Thermochemistry and Electrochemistry What Makes Reactions Go? Fall 2018 Dr. Susan Findlay See Exercises in Topic 8

Technical Data Sheet: Thermokinetics 3

Humidity Calibration Solutions

Transcription:

High Pressure DSC Differential Scanning Calorimeter

Introduction The Differential Scanning Calorimetry (DSC) is the most popular thermal analysis technique to measure endothermic and exothermic transitions as a function of temperature. The instrument is used to characterize polymers, pharmaceuticals, foods/biologicals, organic chemicals and inorganics. Transitions measured include Tg, melting, crystallization, curing, cure kinetics, onset of oxidation and heat capacity. Unsurpassed performance Revolutionary Sensor Design Combined Heat Flux & Power Compensation in one Sensor Unsurpassed sensitivity for detection of melts and weak transitions Benchmark resolution precise separation of close lying events Reliable Automation up to 64 position autosampler Widest temperature range from -150 C to 725 C in one measurement The LINSEIS Differential Scanning Calorimeters (DSC) operates in agreement with national and international standards such as: ASTM D 6186, D 5483, E 1858, E 1782, C 351, D 3417, D 3418, D 3895, D 4565, E 793, E 794, DIN 51004, 51007, 53765, 65467, DIN EN 728, ISO 10837, 11357, 11409. LINSEIS DSC 1000 HP This product was developed to provide a High pressure DSC with a broad temperature range (-150 725 C) for all common applications. Furthermore emphasis was placed on an extremely stable baseline and high reproducibility. The design allows manual and automatic operation. The conception of the cell guarantees maximum mechanical and chemical resistance. The 120 thermocouple sensor MR12 provides highest resolution and outstanding sensitivity. Application areas Adsorption, desorption Oxidation induction time Vulcanisation Curing Hydration Reaction seperation DSC 1000 High Pressure 2

Technology Sensors MR12 120 Thermocouples in a row ensure unparalleled resolution. The glass ceramic sensor designs ensure highest resolution and durability. This sensor is perfectly suited for day to day operation in research and quality control. Crucibles HR24 The combined heat flux & power compensation sensor for most demanding application, 240 thermocouples ensure unsurpassed sensitivity and resolution. Even with smallest sample quantities and slow heating rates weak transitions can be detected. Sensors The key part of every DSC is the sensor, so don t make any compromise. Up to now it has been impossible to achieve highest resolution and sensitivity in one sensor. The revolutionary design of the HiperRes Sensor line now enables just that. The 120 or 240 thermocouples deliver the highest resolution on the market. This permits the detection of smallest thermal effects. The glass ceramic sensor structure ensures shortest possible time constants, permitting the separation of overlapping effects over the full temperature range. Unlike competing metal sensors the ceramic design does not oxidize and thus can be used ongoing over the full temperature range without aging effect. 3

Technical specifications Software Technical specifications DSC 1000 Temperature range -150 up to 725 C Heating and Cooling Rates Sensor Pressure Ultra high pressure option LN 2 -option Gases 0.01 to 150 C/min Highest Sensitivity Shortest Time Constant heat flux MR 120 or HR24 100 bar 300 bar liquid nitrogen cooling option (-150 C) Measurement under static or dynamic conditions Measurement under static or dynamic preassure conditions Software All thermo analytical devices of LINSEIS are PC controlled and the individual software modules exclusively run under Microsoft Windows operating systems. The complete software consists of 3 modules: temperature control, data acquisition and data evaluation. The Linseis 32 bit software encounters all essential features for measurement preparation, execution and evaluation with a DSC run, just like with other thermo analytical experiments. Due to our specialists and application experts LINSEIS was able to develop this easy understandable and highly practical software. Features Temperature Modulated DSC Repetition measurements with minimum parameter input Evaluation of current measurement Curve comparison up to 32 curves Curve subtraction Multi-methods analysis (DSC TG, TMA, DIL, etc.) Zoom function 1. and 2. Derivative Multiple smoothing functions Complex peak evaluation Multipoint calibration for sample temperature Multipoint calibration for change of enthalpy Cp calibration for heat flow Storage and export of evaluations Program capable of text editing Export and import of data ASCII Data export to MS Excel Signal-steered measuring procedures Zoom in function Undo function The following interesting physical properties of materials can be measured: Enthalpy, melting energy Specific heat Glass point Crystallinity Reaction enthalpy Thermal stability Oxidation stability Aging Purity Phase transformation Eutectics Polymorphs Product identification 4

Applications Oxidation Induction Time (OIT) 3 2 1 Heat Flow [W/g] 0 1 2 123.16min 300 psi O 2 142.71min 200 psi O 2 211.27min 100 psi O 2 3 4 0 50 100 150 200 250 Time [min] The OIT method is a standardized procedure, providing information about the thermal and oxidative stability of raw materials. Its main application is the investigation of polymers and plastic materials which are undergoing continous aging processes and therefore have to be equipped with various stabilizers according to their oxidation liability. There are two different OIT procedures: Using the dynamic procedure (characteristic: temperature), the sample is heated at a defined heating rate from the beginning in air or oxygen atmosphere. The beginning of an oxidation process will be detected as an exothermic divergence of the baseline which is characterized by a specific temperature. Advantages and Disadvantages of the dynamic procedure are the short expenditure of time as well as the lower sensitivity of the measurement that comes along with it, especially at higher temperatures. The more common, standardized static procedure (characteristic: time) differs in the atmosphere while heating the sample: Here the sample is heated at inert nitrogen atmosphere to a temperature (200 C) beyond the melting point. Afterwards the atmosphere is changed to air or oxygen atmosphere and the isothermal measurement starts. Depending on the substance, after a while an oxidation process can be observed as divergence of the baseline at a specific time. This point marks the so called OIT time. 5

Vapor pressure diagramm of water If the vapour pressure of any liquid reaches the value of it s environmental pressure, the substance begins to boil. In case of water this point is usually reached at 100 C at normal atmosphere. By increasing the environmental pressure, the boiling point will change to higher temperatures, too. This effect is different for each substance (due to their individual vapour pressures) and therefore it is often necessary to measure phase diagrams. This can be done with the LINSEIS High Pressure DSC, as shown in the example. The boiling point of water was determined at different pressures, where it appeared as an evaporation peak. These peaks can be plotted to a phase diagram according to the Clausius Clapeyron equation, where the resulting diagram fi ts the literature values in a good way. This procedure can be done with almost every non corrosive liquid. 200 mw Heating rate: 5 C/min Atmosphere: N 2 Crucibles: Al with pierced lids 1.25 bar 5.0 bar 25.0 bar 50.0 bar 120.0 bar 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 Temperature [ C] 6 Measured: H V = 40.6 KJ/mol Literature: H V = 40.5 KJ/mol 5 In (p/p 0 ) = 4855.2/T + 13.1 4 3 In (p/p 0 ) 2 1 0-1 -2 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 1/T [1/1000K] LINSEIS Application Handbook: Polymer Applications DTA DSC HDSC TG TMA DIL MS/FTIR Coupling 6

LINSEIS GmbH Vielitzerstr. 43 95100 Selb Germany Tel.: (+49) 9287 880-0 Fax: (+49) 9287 70488 E-mail: info@linseis.de LINSEIS Inc. 109 North Gold Drive Robbinsville, NJ 08691 USA Tel.: (+1) 609 223 2070 Fax: (+1) 609 223 2074 E-mail: info@linseis.com LINSEIS China Kaige Scientific Park 2653 Hunan Road 201315 Shanghai Tel.: (+86) 21 5055 0642 Fax.: (+86) 21 6806 3576 www.linseis.com.cn LINSEIS France Bureaux Paris 52 Boulevard Sébastopol 75003 Paris Tel.: (+33) 173-028 272 www.linseis.fr www.linseis.com Products: DIL, TG, STA, DSC, HDSC, DTA, TMA, MS/FTIR, In-Situ EGA, Laser Flash, Seebeck Effect, Thin Film Analyzer, Hall-Effect Services: Service Lab, Calibration Service