UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2004/2005. March KAA 502 Atomic Spectroscopy.

Similar documents
Atomic Absorption & Atomic Fluorescence Spectrometry

9/13/10. Each spectral line is characteristic of an individual energy transition

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

FLAME PHOTOMETRY AIM INTRODUCTION

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

a. An emission line as close as possible to the analyte resonance line

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

3 - Atomic Absorption Spectroscopy

high temp ( K) Chapter 20: Atomic Spectroscopy

AN INTRODUCTION TO ATOMIC SPECTROSCOPY

CH. 21 Atomic Spectroscopy

Elemental analysis of river sediment using the Agilent 4200 MP-AES

2101 Atomic Spectroscopy

Optical Atomic Spectroscopy

Emission spectrum of H

very high temperature for excitation not necessary generally no plasma/arc/spark AAS

Determination of the inorganic ion composition of standing surface water

Chem 155 Quiz 3 Review Topics: Quiz 3 outline

EXPERIMENT 7. Determination of Sodium by Flame Atomic-Emission Spectroscopy

Atomic Absorption Spectrophotometry. Presentation by, Mrs. Sangita J. Chandratre Department of Microbiology M. J. college, Jalgaon

Lecture 7: Atomic Spectroscopy

MASTERING THE VCE 2014 UNIT 3 CHEMISTRY STUDENT SOLUTIONS

Test Method: CPSC-CH-E

A Spectrophotometric Analysis of Calcium in Cereal

Determination the elemental composition of soil samples

International Journal of Scientific & Engineering Research, Volume 8, Issue 1, January ISSN

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Atomic Absorption Spectroscopy

Chapter 9. Atomic emission and Atomic Fluorescence Spectrometry Emission spectrophotometric Techniques

ICP-OES Application Note Number 35

PRINCIPLES OF AAS atomization flame furnace atomization absorption

DRAFT EAST AFRICAN STANDARD

Analysis of domestic sludge using the Agilent 4200 MP-AES

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

ATOMIC ABSORPTION SPECTROSCOPY (AAS) is an analytical technique that measures the concentrations of elements. It makes use of the absorption of light

Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Debjani Banerjee Department of Chemical Engineering IIT Kanpur

PRINCIPLE OF ICP- AES

Journal of Chemical and Pharmaceutical Research, 2014, 6(5): Research Article

INTRODUCTION Atomic fluorescence spectroscopy ( AFS ) depends on the measurement of the emission ( fluorescence ) emitted from gasphase analyte atoms

Atomic Absorption Spectroscopy (AAS)

HEAVY METALS IN LAKE NAKURU ATOMIC SPECTROSCOPY

ATOMIC SPECROSCOPY (AS)

Atomic Emission Spectroscopy

Sodium Chloride - Analytical Standard

Investigation of Nutrient Elements in Cucurbita pepo Using Atomic Absorption Spectrometry

Atomic Spectroscopy AA/ICP/ICPMS:

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

Final Exam. Physical Constants and Conversion Factors. Equations

10/2/2008. hc λ. νλ =c. proportional to frequency. Energy is inversely proportional to wavelength And is directly proportional to wavenumber

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

GB Translated English of Chinese Standard: GB

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

The Investigation of Fertilizer Analyses Using Microwave Digestion and the Agilent 720-ES

Ch. 9 Atomic Absorption & Atomic Fluorescence Spectrometry

COMPARISON OF ATOMIZERS

Investigation of Nutrient Elements in Cucurbita pepo Using Atomic Absorption Spectrometry

Trace elemental analysis solutions for your application. June 6, 2018

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

ISO INTERNATIONAL STANDARD. Water quality Determination of trace elements using atomic absorption spectrometry with graphite furnace

Spectroscopy Problem Set February 22, 2018

II. Spectrophotometry (Chapters 17, 19, 20)

Chapter 8: An Introduction to Optical Atomic Spectrometry

Complete the following. Clearly mark your answers. YOU MUST SHOW YOUR WORK TO RECEIVE CREDIT.

novaa 800 D Atomic Absorption Spectrometer

Partial Energy Level Diagrams

Chemistry Instrumental Analysis Lecture 18. Chem 4631

INTRODUCTION TO OPTICAL ATOMIC SPECTROSCOPY (Chapter 8)

Atomization. In Flame Emission

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Brooklyn College Department of Chemistry

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

CHEM 221 Instrumental Analysis FINAL EXAM May 10, 2016

Quality Assurance is what we do to get the right answer for our purpose FITNESS FOR PURPOSE

SELİN CANSU ÖZTÜRK ŞEYMA ATAKUL SEZİN GÜNER

5. Is Chlorine important (far UV option for some ICP-OES spectrometers)?

DETERMINATION OF TRACE METALS IN MAHAWEEL RIVER SEDIMENTS BY ACID EXTRACTION

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Atomic absorption spectroscopy

METHOD 6010A INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROSCOPY

Quantitative analysis of Na, K and Ca in milk and yogurt using the MH-5000 Ultra Compact Elemental Analyzer

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

Atomic Absorption Spectrometer ZEEnit P series

Ar Ar + e - INDUCTIVELY+COUPLED+ PLASMA+SPECTROMETRY+ What+is+Plasma?+ FuncDon+of+Plasma+

Exam 3 Chem 454 April 25, 2018, Name

V. LAB REPORT. PART I. ICP-AES (section IVA)

CHAPTER V ANALYTICAL METHODS ESTIMATION OF DICLOFENAC. Diclofenac (gift sample from M/s Micro Labs Ltd., Pondicherry)

Experiment 1 (Part A): Plotting the Absorption Spectrum of Iron (II) Complex with 1,10- Phenanthroline

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

Samples compliant with the WATER

NOTICE: This method: The laboratories have to study the instrumental conditions appropriate for their own instrumentation.

METHOD 7000B FLAME ATOMIC ABSORPTION SPECTROPHOTOMETRY

Analysis of Arsenic, Selenium and Antimony in Seawater by Continuous-Flow Hydride ICP-MS with ISIS

Ch 313 FINAL EXAM OUTLINE Spring 2010

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

Application note. Determination of exchangeable cations in soil extracts using the Agilent 4100 Microwave Plasma-Atomic Emission Spectrometer

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Chemistry 311: Topic 2 - Atomic Spectroscopy Topic 2: Spectroscopy:

Handbook of Inductively Coupled Plasma Spectrometry

Transcription:

UNIVERSITI SAINS MALAYSIA Second Semester Examination Academic Session 2004/2005 March 2005 KAA 502 Atomic Spectroscopy Time: 3 hours Please make sure this paper consists of FIVE typed pages before answering the questions. Answer FIVE questions only. This paper contains SIX questions. Only the first five questions answered by the candidate will be marked. 2/-

- 2-1. (a) How would you carry out the determination of calcium in a yogurt sample using flame atomic absorption spectrometry? Please include the sample preparation method and calibration technique used. Outline all steps taken to ensure that all chemical and physical interferences are overcome. How do you validate your results? How is background correction based on the Zeeman effect performed in a graphite furnace atomic absorption spectrometer? (6 marks) (c) The maximum burning velocity for an air/acetylene flame is 160 cm s -1 whereas that for a nitrous oxide/acetylene flame is 285 cm s -1. How does this influence the kind of slot burners used for both flames? (4 marks) 2. (a) Explain how matrix modification may lead to more efficient matrix removal in electrothermal atomization. Give an example. (4 marks) Why is an echelle monochromator most suitable to be used with an array detector? 3/-

- 3 - (c) The determination of trace elements in seawater is carried out using a graphite furnace atomic absorption spectrometer. Calibration is achieved by the method of standard additions. The trace metals are first separated from their complex in high salt matrix by coprecipitating them with Fe 3+. A 5.00 ml of 2000 ppm Fe 3+ solution was added to a 1.00 L sample of sea water to precipitate the Fe(OH) 3 after the ph is adjusted to 9. The precipitate is isolated, rinsed and dissolved in 2 ml concentrated HNO 3 and diluted to volume in a 50 ml volumetric flask. To analyze for Mn 2+, a 1.00 ml sample of this solution was diluted to 100 ml in a volumetric flask. The following samples were injected into a graphite furnace and analyzed. Solution Absorbance 2.5 µl sample + 2.5 µl 0 ppb Mn 2+ standard 0.223 2.5 µl sample + 2.5 µl 2.5 ppb Mn 2+ standard 0.294 2.5 µl sample + 2.5 µl 5.0 ppb Mn 2+ standard 0.361 Report the concentration of Mn 2+ in the sample of seawater in ppb. (11 marks) 3. (a) The requirements for a monochromator in flame emission and atomic absorption are rather different. Assume that your laboratory is considering the purchase of a monochomator. Your choice is a variable slit width system (lowest spectral bandwidth = 0.5 Å) with high resolution but is expensive and another system with fixed slit widths (spectral bandwidth = 10 Å), medium resolution and is less expensive. Which system will you choose for your laboratory if you are only involved with atomic absorption measurements? Give reasons for your choice (with respect to functions of the monochromator for both techniques and the role of the monochromator in overcoming interferences). Suggest the most suitable method for the following determinations. Please give justifications for your answer. (i) (iii) Calcium in blood serum. Selenium in milk. Calcium in tap water. 4/-

(iv) (v) Chromium in blood. - 4 - Antimony in air particulates. 4. (a) Give a scientific reason for the following statements: (i) Ionization interferences are usually not as severe in the inductively coupled plasma (ICP) as in flames. Potassium salts (such as KCl) are frequently added when one wants to measure elemental sodium by flame photometer. Potassium concentration in a blood serum is to be analyzed using the method of standard addition by flame emission spectrometry. Two extractions of 0.5 ml of serum were taken to create two identical solutions and then both were diluted further with distilled water to a final volume of 5 ml. A 10 µl of 0.2 M KCl is introduced to one of these. The values obtained from the apparatus were 32.1 and 58.6 arbitrary units. What is the potassium concentration (M) of the serum? 5. (a) (i) What advantages does an ICP source offer over an electrical discharges source? Do electrical discharge sources have any advantages over ICP sources? Explain. (iii) Flame atomic absorption spectrometry has achieved very wide use as a routine method for the determination of trace metals in solution. However, for alkali metals flame photometry has remained popular. Why is this? What is the purpose of an internal standard in ICP-MS? 5/-

- 5 - The chromium in a series of steel samples was determined by ICP-AES. The spectrometer was calibrated with a series of standards containing 0, 2.0, 4.0, 6.0 and 8.0 µg K 2 Cr 2 O 7 per ml. The instrument readings for these solutions were 3.1, 21.5, 40.9, 57.1 and 77.3 respectively, in arbitrary units. The following data were obtained for replicate 1.00 g samples of cement dissolved in HCl and diluted to 100.0 ml after neutralization. Calculate the percentage of Cr 2 O 3 in each sample. What is the reproducibility for each determination? Emission readings Blank Sample A Sample B Replicate 1 5.1 28.6 40.7 Replicate 2 4.8 28.2 41.2 Replicate 3 4.9 28.9 40.2 6. (a) Explain clearly why atomic emission methods with an ICP source are better suited for multielement analysis than flame atomic absorption methods. What are the main ionization and excitation mechanisms that occur in the ICP? (c) How does an ion sampling interface system used for ICP-MS compare with those used for ICP-AES? (d) Give your opinions why has ICP-MS become an important and widely used analytical method. -ooo O ooo-