PRINCETON CHROMATOGRAPHY INC

Similar documents
HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

KromasilSFC. Designed for green technology. Introducing Kromasil SFC XT

Packings for HPLC. Packings for HPLC

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

Epic Aromatic Selectivity

Alltech Alltima HP Introduction

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

penta-hilic UHPLC COLUMNS

LC and LC/MS Column Selection Flow Chart

Basic Principles for Purification Using Supercritical Fluid Chromatography

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

Optical Isomer Separation Columns and Packing Materials

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ChromegaChiral TM CSP Media and Columns

Hypersil BDS Columns TG 01-05

penta-hilic UHPLC COLUMNS

HPLC Column Material - Bulk Ware

for Acclaim Mixed-Mode HILIC-1 Column

LC Technical Information

Sample Preparation TLC Plates

Kromasil Eternity Designed for long life. For use in HPLC and UHPLC

Technical Guide Thermo Scientific Syncronis HPLC Columns

ChromegaChiral TM CSP Media and Columns

A Look at Agilent HPLC Columns Choices

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Changing the way you think about HPLC

Next Generation of Phenyl Columns. Chromatography Products.

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Optimisil HPLC & UPLC Column catalogue

Small Molecule Selectivity Sampler

Shodex TM ODP2 HP series columns

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - SOLA & HyperSep. Catalogue 9.

6 Optical Isomer Separation Columns

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

Tracer Excel TRACER EXCEL ODS-A. Total deactivation. Maximum Stability

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Kromasil Eternity Designed for long life

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Fluophase and Fluofix Columns

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Kromasil Eternity Designed for long life

Gemini-NX Performance paired with Axia Technology

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

Stationary phases for prep LC

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

State-of-the-art C18 HPLC Columns

Acclaim Mixed-Mode WCX-1

8. Methods in Developing Mobile Phase Condition for C18 Column

Part 2. Overview of HPLC Media

Do you need trouble-free speed? The NEW Chromolith HR

FAQ's. 1 - Which column would be the most appropriate for my application?

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

The Evolving HPLC Column Packings

Successfully Scaling and Transferring HPLC and UPLC Methods

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Do you need trouble-free speed? The NEW Chromolith HR

Supercritical Fluid Chromatography

1.7 m Fortis UHPLC Columns

TCI Chiral HPLC Column

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Thermo Scientific Acclaim. Catalogue 9. Hichrom Limited

Too Polar for Reversed Phase What Do You Do?

ACE Ultra Inert Base Deactivated HPLC Columns

Method Development Kits

ACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC

for Acclaim Mixed-Mode WCX-1

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Separation of Structurally Similar Steroids on HALO C18 and PFP

HPLC UHPLC Columns. Dikma Technologies Inc.

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases

Analgesics / Cough 1 & Cold Medicine Ingredients

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Inertsil. Catalogue 9. Hichrom Limited

New Product Update. HPLC Columns

Reversed Phase Solvents

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

Supercritical Fluid Chromatography: Past, Present and Future

ColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns

Bringing uhplc Performance to the Separation of Peptides

Gemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Comparison of different aqueous mobile phase HPLC techniques

Sepax SRT -C, Zenix -C SEC Phases

CLIPEUS - A Small Shield for a Big Job

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases

HPLC COLUMNS VaRian, inc. Pursuit XRs EXtRa REsolution. Ma XiMuM lifetime. ultimate PERfoRMancE.

Transcription:

ABOUT US Princeton Chromatography Inc., based in Cranbury, New Jersey, USA, was founded in 99. We have over 0 years experience in chromatography and are one of the earliest developers of novel commercial SFC phases. Princeton Chromatography Inc. delivers the highest quality, cutting edge products backed by unmatched technical support. From SFC to HPLC, analytical to preparative, all columns are manufactured on-site and subjected to rigid quality standards. Every SFC and HPLC column is tested and shipped with an original chromatogram. All stationary phase media are bonded at our facility, so the quality and reproducibility of each batch can be closely monitored. All columns are packed and tested on-site by our team of production specialists to ensure the highest level of satisfaction for our customers. Princeton Chromatography manufactures a wide range of phases for SFC and both reversed-phase and normal-phase HPLC. We are one of the world leaders in the development of innovative SFC phases. With so many stationary phases and column dimensions to choose from, we can make your scale up easy and worry free. From.0 mm screening columns for LC-MS to kilograms of bulk media, we are with you every step of the way. PRINCETON. OFFERS: Widest selection of bonded achiral SFC phases on the market Wide range of HPLC phases for analytical and preparative applications Bulk materials for HPLC Custom column packing services for SFC, SMB and preparative applications Chiral media repacking services Small scale purification service PrincetonSFC SFC Columns...Pages - PrincetonSPHER HPLC Columns... Pages -7 Other Services...Page 8

SFC Overview Supercritical Fluid Chromatography (SFC) is a as the mobile phase. Although SFC has been around for some time, its adaptation as an orthogonal technique to HPLC, particularly in the pharmaceutical industry, has seen an increase over the last few years. This interest has been fuelled by the increasing requirement for high throughput and a desire for green techniques. Large reductions in decreased sample processing and drying-down times in preparative SFC, as well as providing cost and safety Figure. CO Phase Diagram! "#!$ %#""#&'(! )! $* ")& + &,-. /$* $* )$#& #0 ) "#!%* )! "$*)&#' (typically % to 60% v/v) to aid elution of very polar or ionic %#"#&! * "# "#! $*!#')$&6 #/ #0 $*!%$%)' + )& &*)&%! $*!'%$$( #0 $*!))$#&,%$%)' +! %)& *)!#')$&6 #/! similar to organic solvents but with higher diffusivity, lower viscosity and lower surface tension. The lower viscosity )''#/! *6* +#/ )$! %#") $# 78. ')&6 $# 0)!$ methods. Any solute soluble in methanol or a less polar organic solute will elute in SFC. For polar compounds, a more polar additive may also be added to the mobile phase to facilitate elution and improve peak shape. Packed column SFC has developed from HPLC instrumentation and columns. The mobile phase is kept supercritical by an electronically controlled variable pressure restrictor positioned after the detector. Key Benefits of SFC Fast analyses Reduced solvent consumption 9 :;<= >?@ ABCDE F?EE;GHD Lower cost per sample Compatible with MS Excellent for preparative separations Retention mechanisms in SFC are currently not well understood, but depend mainly on the nature of the stationary phase. SFC is generally seen as a normal-phase technique, predominantly using polar stationary phases, along with less polar mobile phases. However, hydrophobic C8 bonded silica phases offer a reversed-phase retention mode and different selectivity. In fact any HPLC phase can be used for SFC, in addition to the wide range of available phases EFDI;JIBHHK LDE;<MDL N?A OPQR The table below shows typical starting conditions for an achiral analytical SFC assay. For basic analytes, a pyridine based column is a good starting point. For acidic compounds, a diol type column may be more retentive. Neutral compounds do not generally require an additive for elution. Typical Analytical Conditions for Achiral SFC Stationary Phase Silica, Diol, -Ethylpyridine etc. Column Dimensions Length i.d. Mobile Phase ST UVWXYZ[ Additive * Gradient, 0, 7, 0, 0 mm.0,.0,.0,.6 mm Flow rate: ml/min Methanol 0.% Diethylamine or mm ammonium acetate (for basic compounds) 0.% TFA or 0.% formic acid (for acidic compounds) \ ] \^_ `VWXYZ[ Pressure 00-00 bar Temperature C Detection UV, MS, ELSD, CAD * - % water may also be added if required

PrincetonSFC Phases Achiral SFC separations typically require normal-phase type polar stationary phases, such as silica, amino, cyano and diol. Although these phases are adequate for many applications, there is still a need for additional polar phases to meet the demands of difficult separations. At Princeton Chromatography we have led the way in developing a series of novel amide, urea and pyridine phases that enhance the capability of the SFC technique by providing increased selectivity and loading capacity. Princeton 00 and later the -Ethylpyridine phase. PrincetonSFC -Ethylpyridine is non-endcapped and has become the column of choice for achiral SFC analysis of basic compounds. This phase generally requires no addition of amines to the eluent, producing excellent peak shape and reproducibility. A diol phase is a popular and versatile stationary phase for SFC. We have also developed several different hydroxylated stationary phases, most notably the HA Series, which offer excellent selectivity and retention characteristics. These phases are a great starting point for impurity analysis. Phase Pore Size (Å) Particle Size (µm) Structure Phase Code -Ethylpyridine 60 00 00,, 0.,,, 0,, 0 77 Silica 60 00,, 0,, 0 0 Cyano 60 00,, 0,, 0 07 60 00,, 0,, 0 60, 0 79 09!" 60 00,, 0,, 0 86 Amino 60 00,, 0,, 0 08 DEAP (Diethylamino) 60,, 0 7 Benzamide 00,, 0 76 PA (Propylacetamide) 60,, 0 80 PPU (Propylpyridylurea) 00,, 0 8

Phase Pore Size (Å) Particle Size (µm) Structure Phase Code Propylurea 00,, 0 6 DNP (Dinitrophenyl) 00,, 0 9 Pyridine Amide 60,, 0 8 -Ethylpyridine 60 00,, 0,, 0 90 Methane Sulfonamide 60,, 0 9 Benzene Sulfonamide 00,, 0 9 -Nitrobenzene Sulfonamide 00,, 0 9 -Fluorobenzene Sulfonamide 00,, 0 96 HA-Pyridine 60,, 0 87 HA-Dipyridyl 00,, 0 88 HA-DEA (Diethylamino) 60,, 0 6 HA-DHP (Dihydroxypropyl) 00,, 0 69,-Dihydroxyphenyl 00,, 0

PrincetonSFC Analytical Columns PrincetonSFC analytical columns are available with lengths of 0 to 0 mm and internal diameters of.0,.0,.0 and.6 mm. All PrincetonSFC columns are individually quality assured by SFC. Available particle sizes are, and 0 μm, with an additional. μm particle size phase available for the PrincetonSFC -Ethylpyridine columns. Pore sizes of 60, 00 and 00Å (for -Ethylpyridine phase) are available. Ordering Information In order to determine the part number of your required PrincetonSFC analytical column, just insert the phase code X from the table below into the part number table (e.g. for a 0 x.6 mm -Ethylpyridine column with a pore size of 60 Å and a particle size of μm, the part number is 006-077). PHASE CODES: Phase Code X Phase Code X Phase Code X -Ethylpyridine 77 Benzamide 76 Benzene Sulfonamide 9 Silica 0 PA 80 -Nitrobenzene Sulfonamide 9 Cyano 07 PPU 8 -Fluorobenzene Sulfonamide 96 09 Propylurea 6 HA-Pyridine 87 79 DNP 9 HA-Dipyridyl 88 86 Pyridine Amide 8 HA-DEA 6 Amino 08 -Ethylpyridine 90 HA-DHP 69 DEAP 7 Methane Sulfonamide 9,-Dihydroxyphenyl Pore Size (Å) Particle Size (µm) Column Length (mm) 6 Column i.d. (mm).0.0.0.6 60 0 0000-0X 0000-0X 0000-0X 0006-0X 60 7 0700-0X 0700-0X 0700-0X 0706-0X 60 00 0000-0X 0000-0X 0000-0X 0006-0X 60 0 000-0X 000-0X 000-0X 006-0X 60 0 000-0X 000-0X 000-0X 006-0X 60 0 0000-0X 0000-0X 0000-0X 0006-0X 60 7 0700-0X 0700-0X 0700-0X 0706-0X 60 00 0000-0X 0000-0X 0000-0X 0006-0X 60 0 000-0X 000-0X 000-0X 006-0X 60 0 000-0X 000-0X 000-0X 006-0X 60 0 0 0000-00X 0000-00X 0000-00X 0006-00X 60 0 7 0700-00X 0700-00X 0700-00X 0706-00X 60 0 00 0000-00X 0000-00X 0000-00X 0006-00X 60 0 0 000-00X 000-00X 000-00X 006-00X 60 0 0 000-00X 000-00X 000-00X 006-00X 00 0 0000-0X 0000-0X 0000-0X 0006-0X 00 7 0700-0X 0700-0X 0700-0X 0706-0X 00 00 0000-0X 0000-0X 0000-0X 0006-0X 00 0 000-0X 000-0X 000-0X 006-0X 00 0 000-0X 000-0X 000-0X 006-0X 00 0 0000-0X 0000-0X 0000-0X 0006-0X 00 7 0700-0X 0700-0X 0700-0X 0706-0X 00 00 0000-0X 0000-0X 0000-0X 0006-0X 00 0 000-0X 000-0X 000-0X 006-0X 00 0 000-0X 000-0X 000-0X 006-0X 00 0 0 0000-00X 0000-00X 0000-00X 0006-00X 00 0 7 0700-00X 0700-00X 0700-00X 0706-00X 00 0 00 0000-00X 0000-00X 0000-00X 0006-00X 00 0 0 000-00X 000-00X 000-00X 006-00X 00 0 0 000-00X 000-00X 000-00X 006-00X 00 0 0000-08X 0000-08X 0000-08X 0006-08X 00 7 0700-08X 0700-08X 0700-08X 0706-08X 00 00 0000-08X 0000-08X 0000-08X 0006-08X 00 0 000-08X 000-08X 000-08X 006-08X 00 0 000-08X 000-08X 000-08X 006-08X 00 0 0000-08X 0000-08X 0000-08X 0006-08X 00 7 0700-08X 0700-08X 0700-08X 0706-08X Guard cartridges are available for PrincetonSFC analytical columns please enquire.

PrincetonSFC Analytical Columns (continued) Pore Size (Å) Particle Size (µm) Column Length (mm) Column i.d. (mm).0.0.0.6 00 00 0000-08X 0000-08X 0000-08X 0006-08X 00 0 000-08X 000-08X 000-08X 006-08X 00 0 000-08X 000-08X 000-08X 006-08X 00 0 0 0000-080X 0000-080X 0000-080X 0006-080X 00 0 7 0700-080X 0700-080X 0700-080X 0706-080X 00 0 00 0000-080X 0000-080X 0000-080X 0006-080X 00 0 0 000-080X 000-080X 000-080X 006-080X 00 0 0 000-080X 000-080X 000-080X 006-080X Guard cartridges are available for PrincetonSFC analytical columns please enquire. PrincetonSFC Semi-preparative and Preparative SFC Columns All Princeton semi-preparative and preparative SFC columns are packed using the same high quality bonded phases as the corresponding analytical columns, making scale up from analytical dimensions seamless and straightforward. Princeton preparative columns are available with internal diameters from 7.8 to 0.0 mm and in lengths from 0 mm to 0 mm. All columns are quality controlled by SFC and individual SFC documentation is included with each column. Ordering Information Part numbers are determined using the same phase codes as for analytical columns (see page for phase code table). e.g. for a 0 x. mm Propylurea column with a pore size of 00 Å and particle size of 0 μm, the part number is 0-006 PrincetonSFC Semi-preparative and Preparative SFC Columns Part Numbers Column Column i.d. (mm) Pore Size Particle Length (Å) Size (µm) (mm) 7.8 0.0. 0.0 0.0 60 0 00078-0X 0000-0X 00-0X 0000-0X 0000-0X 60 00 00078-0X 0000-0X 00-0X 0000-0X 0000-0X 60 0 0078-0X 000-0X 0-0X 000-0X 000-0X 60 0 0078-0X 000-0X 0-0X 000-0X 000-0X 60 0 0 00078-00X 0000-00X 00-00X 0000-00X 0000-00X 60 0 00 00078-00X 0000-00X 00-00X 0000-00X 0000-00X 60 0 0 0078-00X 000-00X 0-00X 000-00X 000-00X 60 0 0 0078-00X 000-00X 0-00X 000-00X 000-00X 00 0 00078-0X 0000-0X 00-0X 0000-0X 0000-0X 00 00 00078-0X 0000-0X 00-0X 0000-0X 0000-0X 00 0 0078-0X 000-0X 0-0X 000-0X 000-0X 00 0 0078-0X 000-0X 0-0X 000-0X 000-0X 00 0 0 00078-00X 0000-00X 00-00X 0000-00X 0000-00X 00 0 00 00078-00X 0000-00X 00-00X 0000-00X 0000-00X 00 0 0 0078-00X 000-00X 0-00X 000-00X 000-00X 00 0 0 0078-00X 000-00X 0-00X 000-00X 000-00X 00 0 00078-08X 0000-08X 00-08X 0000-08X 0000-08X 00 00 00078-08X 0000-08X 00-08X 0000-08X 0000-08X 00 0 0078-08X 000-08X 0-08X 000-08X 000-08X 00 0 0078-08X 000-08X 0-08X 000-08X 000-08X 00 0 0 00078-080X 0000-080X 00-080X 0000-080X 0000-080X 00 0 00 00078-080X 0000-080X 00-080X 0000-080X 0000-080X 00 0 0 0078-080X 000-080X 0-080X 000-080X 000-080X 00 0 0 0078-080X 000-080X 0-080X 000-080X 000-080X Guard cartridges are available for PrincetonSFC preparative columns please enquire. 7

SFC Applications Selectivity of PrincetonSFC -Ethylpyridine, PPU and DIOL PrincetonSFC -Ethylpyridine 6 0 6 8 0 6 PrincetonSFC PPU (Propylpyridylurea) Column Dimensions: 0 x.6 mm Eluent: - CH Flow Rate:.0 ml/min Detection: UV at 0 nm. Ibuprofen. Aspirin. Ketoprofen. Indomethacin. Diclofenac 6. Sulindac 6 Changing stationary phase is a powerful tool for altering selectivity 0 6 8 0 6 8 6 PrincetonSFC DIOL 0 6 8 0 6 8 8

SFC Applications 0 6 8 0 6 8 Separation of Four β-blockers Column: PrincetonSFC -Ethylpyridine, 60 Å, μm Catalog No: 006-077 Dimensions: 0 x.6 mm Eluent: - CH Additive: 0.% N,N-diisopropylethylamine Flow Rate: ml/min Temperature: 0 C Detection: UV at 0 nm Injection Volume: μl. Metopropol tartrate 7. mg/ml. dl-propranolol HCI. mg/ml. Acebutolol HCI 0.8 mg/ml. Pindolol.8 mg/ml Diuretic Compounds Column: PrincetonSFC Benzamide, 00 Å, μm Catalog No: 006-076 Dimensions: 0 x.6 mm Eluent: - CH Flow Rate: ml/min Temperature: 0 C Detection: UV at 0 nm. Diazoxide. Hydrochlorothiazide 0 6 7 8 9 0 0 6 8 7 6 7 8 9 Separation of Basic Compounds Column: PrincetonSFC Propylurea, 00 Å, μm Catalog No: 006-06 Dimensions: 0 x.6 mm Eluent: - CH Additive: 0.% diethylamine Flow Rate:.0 ml/min Detection: UV at nm. 7-Azaindole. -Benzylamino--methylpyridine. H-Pyrido[,,b]-,-oxazin-(H)-one. -Azabenzimidazole. Niacinamide 6. -Aminoisoquinoline 7.,6-Diaminopyridine 8. -(-Pyridyl)piperazine 9

SFC Applications Separation of β-blockers 6 7 Column: PrincetonSFC Silica, μm Dimensions: 0 x.6 mm Eluent: - CH Additive: 0.% TEA Flow Rate:.0 ml/min Detection: UV at 7 nm. Timolol. Metroprolol. Propranolol. Pindolol 6. Acebutolol 7. Atenolol 0 6 8 0 6 8 0 SFC Separation of Test Compounds on PrincetonSFC Methane Sulfonamide Column: PrincetonSFC Methane Sulfonamide, μm Dimensions: 0 x.6 mm Eluent: - CH Additive: 0.% diethylamine Flow Rate:. ml/min Detection: UV at nm. Caffeine. Theophylline. Theobromine. Thymine. Uracil 6. -Fluorouracil 7. Adenine 8. Hypoxanthine 9. -Fluorocytosine 0. Cytosine 0 7 6 8 9 6 8 0 0 6 8 0 6 Separation of Steroids Column: PrincetonSFC Benzamide Dimensions: 0 x.6 mm Eluent: - CH Flow Rate: ml/min Temperature: 0 C Detection: UV at nm. Corticosterone. Cortisone. Prednisone. Prednisolone 0

SFC Applications Test Mixture on PrincetonSFC CN:DIOL Column: μm Dimensions: 0 x.6 mm Gradient: 0- mins % CH! -8 min %-0% CH 8- min 0% CH -0 min - initial conditions Flow Rate: ml/min Temperature: 0 C Detection: UV at nm. Caffeine. Theophylline. Thymine. Uracil. Fenoprofen 6. Flurbiprofen 7. Prednisone 8. Hypoxanthine 9. Hydrocortisone 0. Sulfamerazine. Sulfamethoxazole 0. Sulfaguanidine 6 7 # 9 6 8 0 6 8 Separation of Antimicrobials Column: PrincetonSFC Propylacetamide Dimensions: 0 x.6 mm Eluent: - CH "! Flow Rate: ml/min Temperature: 0 C Detection: UV at nm. Furazolidone. Sulfadimethoxine. Sulfaquinoxiline 0 6 7 8 Separation of Pyridine Amides Column: PrincetonSFC -Ethylpyridine. 00 Å, μm Dimensions: 0 x.6 mm Eluent: CH "! Flow Rate:.0 ml/min Temperature: 0 C Detection: UV at 0 nm. Picolinamide. Niacinamide. Isonicotinamide 0 0. 0. 0.6 0.8.0...6.8

PrincetonSPHER HPLC Phases At Princeton Chromatography we have been developing and manufacturing HPLC columns for over 0 years. We offer a wide variety of bonded phases in a range of particle and pore sizes. PrincetonSPHER-60 Series phases (60 Å pore size) are optimal for compounds under 000 Da molecular weight. In most cases, the high surface area (00 m /g) leads to longer retention times than with the corresponding 00 Å materials. All PrincetonSPHER-60 columns are packed with high purity silica media that are custom bonded at our facility to ensure the highest standards of quality. PrincetonSPHER-00 Series columns are our most versatile, with a large variety of phases available. With a pore size of 00 Å, an average surface area of m /g and excellent batch-to-batch reproducibility, these columns are excellent for method development. PrincetonSPHER-00 Series (00 Å pore size) are the columns of choice for reversed-phase separations of large PrincetonSPHER-HTS is a 60 Å pore size C phase designed for High Throughput Screening and semi-preparative mode. The unique structure of this C ligand facilitates rapid equilibration between gradient runs. PrincetonSPHER C0 is a 00 Å pore size material bonded with a distribution of long chain hydrocarbons that have an average length of C0. This material has been found to successfully separate many isomers in the carotenoid family of long chain molecules. It has also proved useful for the analysis of some larger molecules such as proteins and peptides. PrincetonSPHER PFP separations and is useful for differentiating halogen-containing compounds from their non-halogenated analogues. PrincetonSPHER FO! "#$% & ' their non-halogenated analogues. Princeton ULTIMA bonded phases contain an amide polar embedded functionality, which deactivates neighbouring free silanol groups and enhances the wettability of the bonded ligands. Enhanced ligand wettability makes the ULTIMA C8 column especially suited for applications requiring the use of 00% aqueous mobile phases. PharmaBOND columns are packed with Å pore size 0 μm (or μm for C8 phase) irregular silica particles. C8, Phenyl, CN, Amino and Silica phases are available and are suitable for legacy and pharmacopoeia methods specifying this phase type. They are equivalent to Waters μbondapak and are supplied with internal diameters of.9 and.6 mm.

Specifications of PrincetonSPHER HPLC Phases PRINCETON P P at S e Poa S e( Sa Aa e / C ao o e E pp USP P Co PrincetonSPHER-60 Series C8,, 0 60 00 Yes L 0 C8,, 0 60 00 Yes L7 0 C6,, 0 60 00 0 Yes L 0 C,, 0 60 00 8 No L6 0 Phenyl,, 0 60 00 6 Yes L 0 Diphenyl 60 00 0 Yes L PFP,, 0 60 00 Yes L 06 CN,, 0 60 00 8 No L0 07,, 0 60 00 6 No L8 08,, 0 60 00 6 No L0 09, 0 60 00 9 No L0 79 Silica,, 0 60 00 n/a n/a L 0 PrincetonSPHER-00 Series C8,, 0 00 9 Yes L 0 C8,, 0 00 Yes L7 0 C6,, 0 00 8 Yes L 0 C,, 0 00 6 No L6 0 Phenyl,, 0 00 Yes L 0 PFP,, 0 00 9 Yes L 06 CN,, 0 00 6 No L0 07,, 0 00 No L8 08,, 0 00 No L0 09 Silica,, 0 00 n/a n/a L 0 PrincetonSPHER-00 Series C8, 0 00 00 8 Yes L 0 C8, 0 00 00 Yes L7 0 C, 0 00 00 No L6 0 Phenyl, 0 00 00 Yes L 0 CN, 0 00 00 No L0 07, 0 00 00 No L8 08, 0 00 00 No L0 09 Silica, 0 00 00 n/a n/a L 0 PrincetonSPHER-Phases C0,, 0 00 00 9 No L6 7 HTS (C),, 0 60 00 6 Yes - 70 Cyclohexyl,, 0 60 00 Yes - Fluorooctyl, 0 00 8 Yes - Fluoropropyl, 0 00 No - DEAP, 0 60 00 0. No - 7 ULTIMA Phases C8,, 0 00 6 Yes L C8,, 0 00 Yes L7 Phenyl,, 0 00 Yes L PharmaBOND Phases C8, 0 00 0 Yes L 0 Phenyl 0 00 8 Yes L 0 CN 0 00 6 No L0 07 Amino 0 00 No L8 08 Silica 0 00 n/a n/a L 0

PrincetonSPHER HPLC Columns Column Dimensions Analytical HPLC columns can be supplied with lengths of 0, 7, 00, 0 and 0 mm and with i.d.s of.0,.0 and.6 mm. Semi-preparative and Preparative HPLC columns can be supplied with lengths of 0, 00, 0 and 0 mm and with i.d.s of 7.8, 0.0,., 0.0 and 0.0 mm. Creating a Part Number All Princeton Chromatography column part numbers are of the format XY-ABC where X = column length in mm Y = code for column i.d. A = code for pore size B = code for particle size When creating a part number, please substitute the appropriate codes into this basic format. e.g. for a μm 0 x.6 mm i.d. PrincetonSPHER-00 C8 column, the part number is 006-00. Column i.d. (mm).0.0.0.6 7.8 0.0. 0.0 0.0 Code 00 00 00 06 078 00 00 00 Pore Size (Å) 60 00 00 00 Code 0 0 0 07 08 Particle Size (µm) 0 Code 0 Princeton Guard Column System We recommend that you use guard cartridges in order to extend the lifetime of your column, especially when analyzing samples that are known to contain components which can irreversibly adsorb to the silica phase. The cartridge should be replaced when the column pressure increases, or when the chromatography starts to degrade. The PrincetonGUARD (Analytical and Preparative) column system (holder and cartridge) conveniently attaches to any HPLC column. Princeton Analytical and Preparative guard cartridges (/pack) can be prepared with the same lot of packing material that is in the analytical or preparative column, if requested. Part numbers for guard cartridges are created in the same way as for the analytical columns, by substituting values for A, B and C from the tables above. Princeton AnalyticalGUARD Part Number 0 x.0 mm cartridges (/pk) 0-ABC 0 x.0 mm cartridges (/pk) 0-ABC Holder for.0 and.0 mm i.d. cartridges 0 Princeton PreparativeGUARD Part Number 0 x 0.0 mm cartridges (/pk) 00-ABC 0 x. mm cartridges (/pk) 0-ABC Holder for 0.0 mm i.d. cartridges 0 Holder for. mm i.d. cartridges 0 H o a!! i "ati#e H!! i "ati#e H!! i "ati#e

HPLC Applications 0 6 8 0 Diuretics Column: PrincetonSPHER C8, 00 Å, μm Catalog No: 006-00 Dimensions: 0 x.6 mm Eluent: 60:0 A:B A: 0 mm NH H, ph. B: Acetonitrile Flow Rate:. ml/min Temperature: 0 C Detection: UV at 80 nm Injection: 0 μl ( mg/ml sample). Hydrochlorothiazide. Chlorthalidone. Diazoxide. Furosemide Aromatic Acids Column: PrincetonSPHER C8, 00 Å, μm Catalog No: 0006-00 Dimensions: 00 x.6 mm Eluent: 0:0 A:B A: 0.M H, ph.0 B: Methanol Flow Rate:. ml/min Temperature: Ambient Detection: UV at 0 nm Injection: μl ( mg/ml sample). p-aminobenzoic acid. p-hydroxybenzoic acid. o-aminobenzoic acid. Benzyl alcohol. Salicylic acid 0 6 Steroids Column: PrincetonSPHER C8, 00 Å, μm Catalog No: 006-00 Dimensions: 0 x.6 mm Eluent: 66: A:B A: Acetonitrile B: Water Flow Rate:.0 ml/min Temperature: 0 C Detection: UV at 00 nm Injection: 0 μl ( mg/ml sample) Ethinyl estradiol Norethindrone 0 6

HPLC Applications 6 8 0 6 7 8 9 0 7 9 Explosives Column: PrincetonSPHER C8, 60 Å, μm Catalog No: 006-00 Dimensions: 0 x.6 mm Eluent: 70:0 A:B A: Acetonitrile B: Water Flow Rate:. ml/min Temperature: 0 C Detection: UV at nm Injection: 0 μl ( mg/ml sample).,-dnt., -DPA. N-DPA..,-DPA 6., -DPA 7.,-DPA 8. DPA 9. N-DPA Uracil and -Fluorouracil Column: Catalog No: 006-009 Dimensions: 0 x.6 mm Eluent: 80:0 A:B A: Acetonitrile B: Water FlowRate:.0 ml/min Temperature: 0 C Detection: UV at nm Injection: 0 μl ( mg/ml sample). -Fluorouracil. Uracil 0 6 7 0 6 7 8 9 0 Creatine and Creatinine Column: Catalog No: 0009-000 Dimensions: 00 x.9 mm Eluent: 70:0 A:B* A: 0.% H B: Acetonitrile * with. mg/ml dodecyl sulfate sodium Flow Rate:.0 ml/min Temperature: 0 C Detection: UV at 0 nm Injection: μl ( mg/ml sample). Creatine. Creatinine 6

HPLC Applications Taxol Column: PrincetonSPHER PFP, 60 Å, μm Catalog No: 006-006 Dimensions: 0 x.6 mm Eluent: 0:0 A:B A: Acetonitrile B: Water Flow Rate:.0 ml/min Temperature: 0 C Detection: UV at 0 nm Injection: 0 μl ( mg/ml sample). Taxol 0 6 7 8 9 0 Vanillins Column: Catalog No: 006-0 Dimensions: 0 x.6 mm Eluent: 0:70 A:B A: Acetonitrile B: 0.% H Flow Rate:.0 ml/min Temperature: 0 C Detection: UV at nm Injection: μl ( mg/ml sample). Vanillic acid. Vanillin. Ethyl vanillin 0 6 7 Flavonoids Column: Catalog No. 006-0 Dimensions: 0 x.6 mm Eluent: 60:0 A:B A: 0.% H B: Acetonitrile Flow Rate:.0 ml/min Temperature: 0 C Detection: UV at nm Injection: 0 μl ( mg/ml sample). Quercetin. Naringenin 0 6 7 7

Other Princeton Chromatography Services Bulk Media At Princeton Chromatography, it is our mission to provide our customers with a complete chromatography solution. To that end, we offer the majority of our stationary phases in bulk form. Each SFC and HPLC stationary phase is available in a variety of particle sizes, ranging from 0 μm to 0 μm for spherical and larger for irregular silica. We have the capacity have been proven time and time again to be highly scalable and extremely reliable. All bulk media provided by Princeton Chromatography are custom bonded on site and are subjected to extremely stringent quality standards. Custom Column Packing We are proud to offer custom column packing services at our facility in Cranbury, NJ. At Princeton Chromatography, we have the capability to pack up to 0 mm i.d. columns. No job is too big or too small. With over 0 years of column packing experience, our production team is highly skilled. We can provide one or two day turnaround times on smaller jobs. We columns for SMB applications, with a heavy focus on repacking bulk chiral media (supplied by the customer). We have about our column packing services. Contract Purification! " # $% &' Method Development % selection assistance, to validation, Princeton Chromatography can provide solutions for all of your method development needs. Please contact one of our chromatography experts for more information. C()*+,* -./ Princeton Chromatography Inc. T: -609-860-80 Email: sales@pci-hplc.com Alternatively Contact our Global Partner: Hichrom Ltd, T: + (0) 8 90660 Email: technical@hichrom.co.uk 8

OUR MISSION Our mission at Princeton Chromatography, Inc. is to provide all our customers with the highest quality HPLC and SFC solutions the market has to offer. With over 0 years of combined HPLC experience and close to years serving the SFC market, we are able to provide an unmatched! " # $ $! " %# $& ' team of professional chromatographers is available to assist you not only in the selection and purchase of your columns, but with long-term support. Here at Princeton Chromatography we are constantly innovating and pushing the limits of HPLC and SFC. Quality. Choices. Flexibility. Innovation. Support. Five words one goal. The complete and total satisfaction of our customers. Quality Each and every column is tested and shipped with an original chromatogram. All stationary phase media are bonded at our facility, so the quality and reproducibility of each batch can be closely monitored. All columns are packed and tested on-site by our team of production specialists to ensure the highest level of satisfaction for our customers. Choices We offer a wide range of stationary phases. With new innovative phases still being added periodically, we feel certain we can meet all of your HPLC and SFC needs. All phases are available in a range of particle sizes. From standard to highly specialized custom requirements, nothing is out of reach. We also offer a complete array of column diameters and lengths. Everything from.0 mm i.d. through to 0.0 mm i.d. Flexibility With so many stationary phases and column dimensions to choose from, we can make your scale up easy and worry free. From.0 mm screening columns for LC-MS to kilograms of bulk media, we are with you every step of the way. Innovation Chromatography technology is always moving forward and the challenges facing our customers are constantly changing. We have the ability to react quickly to the changing environment and offer a wide range of products to meet all your needs. Support With over 0 years of hands-on experience, we problems. Our staff are eager to assist you. Please let us know how we can be of service! Princeton Chromatography Inc. 06 Cranbury So. River Road, Cranbury, NJ 08 T: -609-860-80 F: -609-860-80 Email: sales@pci-hplc.com www.pci-hplc.com Global Distribution Partner Hichrom Ltd, The Markham Centre, Station Road, Theale, Reading, Berkshire RG7 PE UK T: + (0) 8 90660 F: + (0) 8 98 Email: sales@hichrom.co.uk www.hichrom.co.uk