LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

Similar documents
AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties

InertSustainSwift C8

State-of-the-art C18 HPLC Columns

InertSustainSwift C8

Inertsil Technical Library

The Evolving HPLC Column Packings

State - of - the -art C18 HPLC Columns

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

Shodex TM ODP2 HP series columns

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Method Development Kits

"Theory and Practice of High Speed Chromatography for Bioanalysis" Stuart Coleman March 20, 2007

LC Technical Information

for Acclaim Mixed-Mode HILIC-1 Column

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Gemini-NX Performance paired with Axia Technology

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Determination of Caffeine by HPLC

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Nexera UC Unified Chromatography

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

HPLC Praktikum Skript

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

A C18 Silica Column With Exceptional Temperature and ph Stability

Fast and Flexible Optimization of Modifier Concentrations Using an Agilent 1290 Infinity LC System with Blend Assist

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Method Transfer between HPLC and UHPLC Instruments Equipment-related challenges and solutions

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

New Product Update. HPLC Columns

Unexpected Peaks in Chromatograms - Are They Related Compounds, System Peaks or Contaminations? From the Diary of an HPLC Detective

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases


ION CHROMATOGRAPHY SYSTEM S 150

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

High Performance Liquid Chromatography

The new Agilent 1290 Infinity Quaternary LC

Transferring Yesterdays Methods to Tomorrows Technology: The Evolution from HPLC to UPLC TM

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

Dilution(*) Chromatography

High Resolution Fast LC

Liquid Chromatography

Impact of Instrument Dispersion on Performance of HPLC Capillary Columns

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

LC and LC/MS Column Selection Flow Chart

637. Thiamethoxam. HPLC method

HPLC. GRATE Chromatography Lab Course. Dr. Johannes Ranke. September 2003

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Advantages of polymerbased. an alternative for ODS

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers.

Determination of trace anions in concentrated hydrofluoric acid

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

GL Chromatodisc. Usage Type Description. GL Chromatodisc Type A GL Chromatodisc Type P GL Chromatodisc Type N 13AI

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

Application Note. Author. Abstract. Xinlei Yang Agilent Technologies Co. Ltd Shanghai, China

H 3 CO H 3 CO S CH 3

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

HPLC Column. Technical Guide

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

It s hot! ZIC -chilic

A New Polymer-based SPE Sorbent to Reduce Matrix Effects in Bioanalytical LC-MS/MS

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Value of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Transferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system

1.7µm Fortis C18 UHPLC Columns

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Successfully Scaling and Transferring HPLC and UPLC Methods

ZirChrom Columns and the Metalox 200-C High Temperature Liquid Chromatography Column Heater - The Future of HPLC has Arrived.

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

LC-MS compatible Separation of the Fungicide Spiroxamine

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

Transcription:

LC800 Smart HPLC Until now UHPLC From now Smart HPLC

Smart HPLC Leads to Ultimate Performance Patent Pending S

LC800 is a completely new and unique concept, designed for maximum performance in high resolution of separations. Take a look at the column oven below and you can see how we have combined all the thermally affected parts inside the column oven. Not only the fluid path is kept as short as possible to minimize dead-volume, but all the tubing connections remain inside the oven. Injection Valve HPLC Column Gradient Mixer Built-in UV detector flow cell unit (other detectors also can be used) The gradient mixer, injector and flow cell are all equilibrated at the setting temperature as the separation column; the result is a significant reduction in band-broadening and sharper peaks, which leads to a dramatic increase in sensitivity and separation. ART HPLC UHPLC and HPLC are now in one Smart HPLC.

Smart HPLC LC800 UHPLC Smart HPLC HPLC LC800 is a new and innovative development concept offering maximum performance for your analysis. Until now, compounds that were difficult to be separated, but these can now be separated easily with LC800. High separation using UHPLC columns are greatly influenced by the system dead-volume. To overcome this we have designed a fully integrated system, consisting of gradient pump, a high capacity autosampler and a range of detectors, together with the unique concept of all the critical system components being built into the column oven. The injection valve, gradient mixer and detector flow cell are thermally stabilized to prevent solvent temperature gradients that can reduce separation efficiency. Hideyuki Uzu LC800 Specialist, R & D Dept.

Minimized Dead - volume Leads to High Performance Separation Until now, compounds that were difficult to be separated, but these can now be separated easily with LC800. LC800 UHPLC 4 Column : Inertsil ODS-4 ( μm, 50. mm I.D) Eluent : CHCN / HO = 65 / 5, v / v Flow Rate : 0.6 ml / min Injection Vol : μl Col. Temp : 40 C Detection : UV 54 nm 4 0. 0.4 0.6 Time(min) Sample.Acetophenone.Benzene.Toluene 0.8.0 4.Naphthalene 0. 0.4 0.6 Time(min) 0.8.0 With long length and large volume of tubing, the peaks become broad. Our integrated system offers the minimized dead-volume. From UHPLC to Smart HPLC Smart HPLC demonstrates the true efficiency of your HPLC column. Using UHPLC components that previously were difficult to separate but these can now be separated easily by LC800. UHPLC requires the use of sub μm packing materials to achieve e high speed separation. Smart HPLC takes advantage of larger r particle size columns to achieve the same rapid separation. There are many benefits in using Smart HPLC, the system and column lifetime are greatly increased due to the lower working pressures and lower possibility of suffering from column-clogging. The improved system performance also means reduced downtime and lower operating costs. So why don't you try Smart HPLC, LC800? Analytical Column ODS.7 μm Inertsil ODS-4 μm Back Pressure High Low Theoretical plate number (Naphthalene) 0000 7500 5000 0 % UP! LC800 UHPLC 5 % UP! Low pressure, but High theoretical plate number! LC800 UHPLC 4

In pursuit of excellent performance Low Carry Over Autosampler LC800 s unique injector washing system means carry-over is virtually eliminated, even in high sensitivity analysis. 00 ng / ml Reserpine Blank Column : Inertsil ODS- ( μm,. 50 mm I.D.) Eluent : A) CHCN B) 0. % HCOOH in HO A / B = 60 / 40, v / v Flow Rate : 0.6 ml / min Col. Temp. : 40 C Detector : LC / MS / MS (ESI, Positive, MRM) 4000Q TRAP (AB SCIEX) Sample Tray LC800 has a high sample capacity, with up to 60 vials(.5 ml) and with a range of different tray options.(option: up to 6 microplates Maintenance Monitor The compact key pad is simple to use with powerful functionality and fits neatly inside the instrument when not being used. 5

Benefits of temperature control When performing very high speed analysis, it is possible that the retention time can become irreproducible due to fluctuations in mobile phase temperature. LC800 offers complete thermostatic stability by building the gradient mixer inside the column oven; the result is excellent retention time reproducibility. Flow Cell with Temperature Control AU C 0.008 40 Flow Cell without Temperature Control AU C 0.008 40 0.006 Cell Temp. 0 0.006 Cell Temp. 0 0.004 0.004 AU 0.00 Baseline 0 0.000-0.00 0 0 0 min 0 0 0 C AU 0.00 0.000-0.00 5 C Baseline 0 0 0 0 min 0 0 0 C Eluent : A) 0.05 % TFA in CHOH B) HO A / B = 5 / 75 Flow Rate : 0. ml / min Detection : UV 4 nm GL Sciences Inc. is certified for ISO 400. GL Sciences Inc. recognizes that the global environmental protection is one of the most important issues to all humankind and that it is essential for companies to try to reduce the environmental burden in order to continue and grow. We contribute to realize a better society through the global environmental protection conscious cooperate activities. The Fukushima Factory is certified for ISO 900. Koji Suzuki Application Specialist GL Sciences Inc. Fukushima factory obtained an International Organization for Standardization ISO 900:008 for quality management system to design, produce and supply instruments, parts, peripheral devices, columns, bulk materials, reagents and spectroscopic cells for gas chromatography and liquid chromatography. 6

Powerful Support for LC/MS High separation efficiency, Minimized dead-volume With the benefits offered by using an integrated oven, it is now possible to separate compounds that previously could not be separated. LC800 system can be used with both a general purpose detector, such as UV-visible etc., also with LC/MS detectors where ion suppression can have a significant effect. Analysis with Smart HPLC offers the sharper peaks with increased peak height and leads to increased sensitivity. AB SCIEX LC800 UHPLC 5s 9s 0.50 0.00 0.50 0.400 0.450 0.50 0.00 0.50 0.400 0.450 0.500 6 4 LC System : LC800 Column : Inertsil ODS- ( μm, 50. mm I.D.) Eluent : A) HO B) CHOH A / B = 50 / 50, v / v Flow Rate : 0.5 ml / min Injection Vol : 5 μl Col. Temp. : 40 C Detection : LC / MS / MS (ESI, Positive, MRM) 4000Q TRAP (AB SCIEX) 4 6 0.0 0. 0.4 0.6 0.8.0..4.6.8.0..4 min 5 Sample. Oxamyl. Methomyl. Aldicarb 4. Bendiocarb 5. Pirimicarb 6. Methiocarb 0.0 0. 0.4 0.6 0.8.0..4.6.8.0..4 min 5 7

Maximum Efficiency The minimized dead-volume increased column performance, and that achieved reducing analysis time. Not just for high speed analysis, but also for routine separations. To get the best out of your column, make sure you choose a system which doesn t compromise on performance. LC800 UHPLC Low theoretical plate number 4 6 8 0 4 6 8 0 4 6 8 Time, min 4 6 8 0 4 6 8 0 4 6 8 Time, min Column : Inertsil ODS-4 ( μm, 50. mm I.D.) Eluent : A) 5 mm Ammonium acetate in CHOH B) 0 mm Ammonium acetate in HO A / B = 85 / 5 - min - 60 / 40 -.5 min 60 / 40 -.5 min - 50 / 50 - min 45 / 55-9.5 min - 5 / 95 -.5 min - 5 / 95, v / v Flow Rate : 0. ml / min Col. Temp. : 40 C Detection : LC / MS / MS (ESI, Positive, MRM) 4000Q TRAP (AB SCIEX) Sample : Pesticides 8

The First Choice Column Inertsil ODS-4 Inertsil, the name of our brand comes from the key word INERT, which is the most important factor in the separation analysis. GL Sciences Inertsil columns delivers the maximum performance of an HPLC column and we would like to support you and your critical analysis. Inertsil ODS-4 column is the most recent addition to the Inertsil line and the most inert columns available.superior peak shapes for all various compounds along with extreme stability under 00 % aqueous mobile phases. Inertsil ODS-4 is just compatible with any type of compounds in any mobile phase conditions delivering highly stable chromatograms for qualitative and quantitative analysis. For more information, please visit our website at : www.glsciences.com/products.html Basic Compound Test 0 0 0 0 0 0 0 0 0 0 0 0 Inertsil ODS-4 Atlantis T Zorbax Eclipse Plus C8 Luna 5μm C8() Column : ODS(5 μm, 50 4.6 mm I.D.) Eluent : A) CHCN B) 5 mm Phosphate buffer ph7.0 A / B = 40 / 60, v / v Flow Rate :.0 ml / min Col. Temp. : 40 C Detection : UV 0 nm Injection Vol. : μl Sample :. Phenol (0.05 mg / ml). Dextromethorphan HBr (0. mg / ml) Acidic Compound Test 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Inertsil ODS-4 Atlantis T Zorbax Eclipse Plus C8 Luna 5μm C8() Column : ODS(5 μm, 50 4.6 mm I.D.) Eluent : A) CHCN B) 0. %HPO4 A / B = 5 / 75, v / v Flow Rate :.0 ml / min Col. Temp. : 40 C Detection : UV 54 nm Injection Vol. : μl Sample :. Brilliant Blue FCF (0.05 mg / ml). Phenol (0. mg / ml). Salicylic acid (0. mg / ml) 9

HPLC and UHPLC are now in one Smart HPLC, LC800. Minimized dead-volume is designed since a column and a detector set in the oven. Dr.Xiaojing Zhou, LC800 Developer, Deputy General Manager of R & D Dept. Until now UHPLC From now Smart HPLC We, GL Sciences do support for your success. Tommy Yoshinaka International Sales Manager 0

For more information Visit our Web site: www.glsciences.com Contact your local GL Sciences Authorized Distributor We reserve the right to change specifications to make improvements without notice. Distributor: - Nishishinjuku 6-chome, Shinjuku-ku, Tokyo 6-0. Japan Tel. +8--5-660 Fax. +8--5-66 http://www.glsciences.com E-mail:world@gls.co.jp