Piezoelectric polymer actuators for active vibration isolation in space applications

Similar documents
INTRODUCTION TO PIEZO TRANSDUCERS

Magneto-Mechanical Modeling and Simulation of MEMS Sensors Based on Electroactive Polymers

10 Measurement of Acceleration, Vibration and Shock Transducers

Finite Element Analysis of Piezoelectric Cantilever

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

Design and Simulation of Comb Drive Capacitive Accelerometer by Using MEMS Intellisuite Design Tool

7. CONCLUSIONS & SCOPE

DEVELOPMENT OF A NOVEL ACTIVE ISOLATION CONCEPT 1

Module 26: Atomic Force Microscopy. Lecture 40: Atomic Force Microscopy 3: Additional Modes of AFM

DAMPING CONTROL OF A PZT MULTILAYER VIBRATION USING NEGATIVE IMPEDANCE CIRCUIT

Measurement Techniques for Engineers. Motion and Vibration Measurement

Transactions on the Built Environment vol 22, 1996 WIT Press, ISSN

SSNEMS Internal Report

Fiber Bragg Grating-Based Acceleration Sensors for Civil and Building Structures

Transduction Based on Changes in the Energy Stored in an Electrical Field

(Refer Slide Time: 1: 19)

Variable Capacitance Accelerometers: Design and Applications

DEVELOPMENT OF DROP WEIGHT IMPACT TEST MACHINE

MAS.836 PROBLEM SET THREE

Piezoelectric Resonators ME 2082

19. Capacitive Accelerometers : A Case Study. 19. Capacitive Accelerometers : A Case Study. Introduction. Introduction (ctnd.)

NIST ELECTROSTATIC FORCE BALANCE EXPERIMENT

C. points X and Y only. D. points O, X and Y only. (Total 1 mark)

CHAPTER 4 DESIGN AND ANALYSIS OF CANTILEVER BEAM ELECTROSTATIC ACTUATORS

2.003 Engineering Dynamics Problem Set 10 with answer to the concept questions

Degradation of Piezoelectric Materials for Energy Harvesting Applications

Simple Harmonic Motion Test Tuesday 11/7

Influence of electromagnetic stiffness on coupled micro vibrations generated by solar array drive assembly

SENSOR DESIGN FOR PIEZOELECTRIC CANTILEVER BEAM ENERGY HARVESTERS

Non-Linear Finite Element Modeling of THUNDER Piezoelectric Actuators

The Analysis of Aluminium Cantilever Beam with Piezoelectric Material by changing Position of piezo patch over Length of Beam

7.Piezoelectric, Accelerometer and Laser Sensors

PHYSICS PRINCIPLES OF FOUCAULT PENDULUM

557. Radial correction controllers of gyroscopic stabilizer

6WDWXVRI/,*2. Laser Interferometer Gravitational-wave Observatory. Nergis Mavalvala MIT IAU214, August 2002 LIGO-G D

DESIGN AND FABRICATION OF THE MICRO- ACCELEROMETER USING PIEZOELECTRIC THIN FILMS

Dynamics of structures

440. Simulation and implementation of a piezoelectric sensor for harmonic in-situ strain monitoring

Dept. of Electrical & Computer Engineering, Dept. of Mechanical Engineering University of Bridgeport, Bridgeport, CT /08/2015

EE C247B / ME C218 INTRODUCTION TO MEMS DESIGN SPRING 2014 PROBLEM SET #1

APPLICATIONS OF VIBRATION TRANSDUCERS

MEMS Tuning-Fork Gyroscope Mid-Term Report Amanda Bristow Travis Barton Stephen Nary

Chapter 8. Model of the Accelerometer. 8.1 The static model 8.2 The dynamic model 8.3 Sensor System simulation

MEMS INERTIAL POWER GENERATORS FOR BIOMEDICAL APPLICATIONS

FINITE ELEMENT MODELLING OF COMPOSITES USING PIEZOELECTRIC MATERIAL

Design and Simulation of Cantilever Based MEMS Bimorph Piezoelectric Energy Harvester

Vibration-Free Pulse Tube Cryocooler System for Gravitational Wave Detectors I

The Cavendish Experiment

PIEZOELECTRIC TECHNOLOGY PRIMER

Wire rope springs for passive vibration control of a light steel structure

LECTURE 12. STEADY-STATE RESPONSE DUE TO ROTATING IMBALANCE

Displacement at very low frequencies produces very low accelerations since:

Chapter 12 Vibrations and Waves Simple Harmonic Motion page

Electrostatic Microgenerators

Module I Module I: traditional test instrumentation and acquisition systems. Prof. Ramat, Stefano

Active Integral Vibration Control of Elastic Bodies

Modal Analysis: What it is and is not Gerrit Visser

The Stanford Gravitational Reference Sensor

Physical Properties of the Spring

Chapter 7 Vibration Measurement and Applications

Module 4: Dynamic Vibration Absorbers and Vibration Isolator Lecture 19: Active DVA. The Lecture Contains: Development of an Active DVA

b. The displacement of the mass due to a constant acceleration a is x=

Modeling and Experimentation: Mass-Spring-Damper System Dynamics

ERROR SOURCE IDENTIFICATION AND STABILITY TEST OF A PRECISION CAPACITANCE MEASUREMENT SYSTEM

Final Exam Solution Dynamics :45 12:15. Problem 1 Bateau

STRAIN GAUGES YEDITEPE UNIVERSITY DEPARTMENT OF MECHANICAL ENGINEERING

Autonomous Mobile Robot Design

Piezoelectric Actuator for Micro Robot Used in Nanosatellite

Oscillations - AP Physics B 1984

Research Article Experimental Parametric Identification of a Flexible Beam Using Piezoelectric Sensors and Actuators

Response Spectrum Analysis Shock and Seismic. FEMAP & NX Nastran

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

Chapter 14: Periodic motion

SIMPLE HARMONIC MOTION

CHAPTER 6 FRICTION AND WEAR ANALYSIS FOR BUSHING

Tracker Tower 01 Prototype Test & Analysis Overview

ANALYSIS AND NUMERICAL MODELLING OF CERAMIC PIEZOELECTRIC BEAM BEHAVIOR UNDER THE EFFECT OF EXTERNAL SOLICITATIONS

SCHOOL OF COMPUTING, ENGINEERING AND MATHEMATICS SEMESTER 1 EXAMINATIONS 2012/2013 XE121. ENGINEERING CONCEPTS (Test)

Active elastomer components based on dielectric elastomers

Institute for Electron Microscopy and Nanoanalysis Graz Centre for Electron Microscopy

Chapter 11 Vibrations and Waves

Introduction to Actuators PK

EE C245 / ME C218 INTRODUCTION TO MEMS DESIGN FALL 2011 C. Nguyen PROBLEM SET #7. Table 1: Gyroscope Modeling Parameters

Simple Harmonic Motion Investigating a Mass Oscillating on a Spring

Practical work: Active control of vibrations of a ski mock-up with a piezoelectric actuator

Lab 11 Simple Harmonic Motion A study of the kind of motion that results from the force applied to an object by a spring

Power Generation Using Piezo Film

Study on Tire-attached Energy Harvester for Lowspeed Actual Vehicle Driving

ACTIVE VIBRATION CONTROL PROTOTYPING IN ANSYS: A VERIFICATION EXPERIMENT

Chapter 23: Principles of Passive Vibration Control: Design of absorber

Physics 41 HW Set 1 Chapter 15 Serway 8 th ( 7 th )

Space Flight Considerations for Precision Optical Instruments

DESIGN AND DEVELOPMENT METHODOLOGY OF ADAPTIVE VIBRATION ABSORBER

Unit 2: Simple Harmonic Motion (SHM)

INC 331 Industrial Process Measurement. Instrument Characteristics

AC : EXPERIMENTALLY DETERMINING MASS MOMENT PROPERTIES

Foundation Engineering Dr. Priti Maheshwari Department Of Civil Engineering Indian Institute Of Technology, Roorkee

Applicability of Self-Powered Synchronized Electric Charge Extraction (SECE) Circuit for Piezoelectric Energy Harvesting

Basic Principle of Strain Gauge Accelerometer. Description of Strain Gauge Accelerometer

Pre-Class. List everything you remember about circular motion...

Transcription:

Piezoelectric polymer actuators for active vibration isolation in space applications Authors: G. Bohannan, V. Hugo Schmidt, D. Brandt, and M. Mooibroek NOTICE: this is the author s version of a work that was accepted for publication in Ferroelectrics. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Ferroelectrics, [VOL# 224, (1999)] DOI# 10.1080/00150199908210569 G. Bohannan, V. Hugo Schmidt, D. Brandt, and M. Mooibroek, Piezoelectric polymer actuators for active vibration isolation in space applications, Ferroelectrics 224, 211-217 (1999). http://dx.doi.org/10.1080/00150199908210569 Made available through Montana State University s ScholarWorks scholarworks.montana.edu

Ferroelrczrrcs, 1999, Vol. 224, pp. 211-217 Reprints available directly from the publisher Photocopying permitted by license only D 1999 OPA (Overseas Publishers Association) N.V. Published by license under the Gordon and Breach Science Publnhers Imprint. Printed in Malaysia Piezoelectric Polymer Actuators for Active Vibration Isolation in Space Applications G. BOHANNAN. H. SCHMIDT, D. BRANDT and M. MOOLBROEK Montana State University, Bozernan, MI: 5971 7, USA (Received August 24,1998; In final form September 14,1998) A lightweight actuator for active vibration isolation in space applications is being developed to replace the heavy electromagnetic systems now in use. The actuator has a low effective spring constant that provides for passive vibration damping down to sub-hertz frequencies while allowing the isolated experiment to follow the neardc bias motion of the spacecraft. The actuator is currently optimized for the vibration level of the Space Shuttle and assembled from a pair of bimorphs in a leaf-spring contiguration. Changing the size and number of sheets used in consmction can vary electromechanical properties. Passive damping has been demonstrated in one and two-dimensional tests. For large (greater than a few kilograms) suspended masses, the system is underdamped and relative velocity feedback must be used to remove the resonance. Real-time control of the resonance frequency is achieved by controlling the voltage applied to the actuator with feedback from a displacement sensor. A folded pendulum seismic monitoring device was adapted for use as a onedimensional low frequency test platform and has obtained accurate measurements of the effective spring constant and damping coefficient. Single-degree-of-freedom active feedback testing is also being conducted using this device. Two-dimensional (threedegree-of-freedom) passive damping tests were conducted on NASA's KC-135 Reduced Gravity Platformin March 1998. Keywords: piezoelectric polymers; vibration isolation; actuators INTRODUCTION An opportunity to demonstrate practical applications of piezoelectric polymers arose with the challenge of replacing the heavy electromagnetic systems now in use on the Space Shuttle for vibration isolation. The goal of [639]/211

212/[640] G. BOHANNAN et al. this project has been to develop a lightweight, low-power system for use in near zero-g applications. By taking advantage of the properties of a springlike device with a low natural spring constant, passive damping down to low frequencies can be used. Active feedback is used to dampen the low frequency resonance. DESIGN REQUIREMENTS In the low gravity environment of the Space Shuttle, a very large experiment (10 s to 100 s of kilograms) can be suspended for vibration isolation using devices exerting very small forces. Small bias forces resulting in one to three micro-g arise due to the fact that the experiments to be isolated are not at the center of gravity of the spacecraft. Vibrations, referred to as g-jitter, occur across the frequency spectrum from sub-hertz to kilohertz. These vibrations measure in the tens to several hundred micro-g. Pulse noise levels produce accelerations on the order of 1000 micro-g, but these contain very high frequency components and passive damping eliminates their effect. Modeling has indicated that, for suspended loads greater than a few kilograms, passive damping can provide isolation for frequencies above a few Hertz. Active damping is added to remove natural resonance. The low force requirement creates an additional requirement for relatively large displacement. For the Space Shuttle environment, a relative displacement of +/- one centimeter is required to achieve a less than 10 micro-g loading on the isolated box. This relative displacement grows with the vibration level of the platform and would be almost a meter for the same level of isolation on an aircraft such as NASA s KC-135 Reduced Gravity Platform. CONSTRUCTION The actuators resemble a small leaf spring. The upper and lower halves of the actuator use a bimorph layout; each bimorph consists of cantilevered-beam sections. Silver is deposited on PVDF sheets to fom the necessary electrode pattern on the top and bottom of each layer. Adhesives are used to bond the layers to form the bimorph and to bond the edges of the two birnorphs to make the leaf spring. The bimorph pre-curvature is obtained by placing the two sheets in a press while the adhesive sets. Copper tabs are attached to the edges to allow routing of control voltages onto the electrode layers. Exposed electrode layers are kept at ground potential for safety. Plus and minus voltages are applied to obtain the appropriate s curvature.

PIEZOELECTRIC POLYMER ACTUATORS [641]/213 In the configuration shown in Figure 1, the voltage polarities cause the actuator to expand. Opposite polarities would produce contraction. Stacking actuators in series allows a larger displacement for the same applied voltage. FIGURE 1 Schematic end view of the actuator. Exposed electrodes are grounded, inner electrode layers are charged with opposite polarity to achieve proper curvature. ELECRICAL AND MECHANICAL TESTING The low force, large displacement characteristics present a challenge for testing. A seismic monitoring device with near zero-g restoring force in one dimension was adapted for use as a test platform. The device, shown in figure 2, consists of a platform suspended between a normal pendulum arm and an inverted pendulum arm[']. The tuning mass and platform have a combined mass of approximately 20-kg. Additional mass may be added for finer tuning. The restoring force from the normal arm is almost canceled by the antirestoring force of the inverted arm. By adjusting the lengths of the arms and the position of the tuning mass it is possible to achieve periods of greater than 20 seconds, or restoring forces of less than 10 micro-g per millimeter of motion. This residual force is small enough that the parameters of the actuator can be readily extracted. Parameters of actuators with dimensions of 5.0x5.0x0.5 cm3 have been measured dynamically using the folded pendulum. Typical values for the passive spring constant are between 15 to 20 N/m and passive damping constants are between 1.3 to 1.6 kg/sec. The variation is due primarily to an inconsistency in construction technique, e.g. controlling the thickness of the adhesive layer. Static measurements show the no-load displacement is approximately 3 mm per kilovolt. The suspended platform provides a near zero-g environment in one dimension, partially simulating the isolated experiment on the Space Shuttle. Data obtained from Shuttle micro-gravity missions contain greater than 10

214/[642] G. BOHANNAN et al. mass Actuator FIGURE 2 Schematic of the folded pendulum test platform. L1 is the normal pendulum arm. L2 is the inverted pendulum arm. micro-g biases, so this test system is well within the error budget of available data. The platform is coupled via the actuator to an exciter driver that simulates the vibrating shuttle Erame. A low-frequency electronic oscillator controls the exciter driver. Position and accelerometer sensor data is wired into a multifunction board in a laboratory PC for data analysis. ACTIVE DAMPING IN ONE DIMENSION Tests conducted using the folded pendulum demonstrated that displacement feedback could be used to change the resonance frequency and induce active damping. An optical position sensing device (PSD) was used to measure the relative displacement between the platform and the exciterldriver. Application of a voltage in-phase with the relative displacement reduced the effective actuator spring constant, while application of voltage out-of-phase with the displacement effectively stiffened the actuator. Measurements of resonant frequency shifts confirmed the adjustment in the effective spring constant. When accelerometer feedback was used to produce a force opposite to the direction of acceleration, measurable damping was observed at frequencies of 5 Hz and above. However, at lower frequencies the signal from the accelerometer dropped below the device noise and damping was not as effective as predicted by modeling. One notable observation made while using the folded pendulum is that the tuning mass may be adjusted to the point that without the actuator in

PIEZOELECTRIC POLYMER ACTUATORS [643]/215 place, the pendulum would soon become unstable. This slight negativetuning appeared to improve the phase accuracy of dynamic measurements. PASSIVE DAMPING ON THE KC-135 NASA has recently been offering opportunities for undergraduates to conduct experiments on their KC-135A Reduced Gravity Platform aircraft. This project was selected for a pair of flights that occurred in March 1998. The KC-135A achieves near zero-g conditions for up to about 25 seconds at a time by flying a series of parabolic loft maneuvers. Each flight typically consists of 40 parabolic maneuvers. The g-jitter experienced by the aircraft is approximately 100 times greater than that of the space shuttle, but a few relatively quiet periods on the order of a few seconds in duration were experienced during each the two flights. The difficulties with the aircraft include air turbulence not felt by the shuttle and the fact that the pilots manually control the aircraft during the maneuvers. The experiment consisted of a suspended mass with three degrees-offreedom (two translational, one rotational) shown in figure 3. Eight sets of two stacked actuators were used. The suspended mass used in this test was less than two kg, which was much smaller than anticipated masses to be isolated on the Space Shuttle. With the higher vibration level, a stiffer system with much faster relaxation time was required. The stiffer system was also necessary to constrain the suspended mass to within the volume of the experiment rack. Even with the stiffening, edge padding was required to constrain the mass during turbulent periods. FIGURE 3 Schematic of the three-degree-of-freedom experiment flown on NASA s KC-135 Reduced Gravity Platform.

216/[644] G. BOHANNAN et al. Due to potential electrical safety problems arising from the separation of the bimorphs, it was necessary to disconnect the actuators from the driver amplifiers and test only the passive characteristics of the system. The accelerometer and position sensing devices remained in operation and control signals were monitored during flight for post facto review of how well the prototype control circuitry operated. Data obtained from the flight indicate that the actuators did suspend the simulated experiment box and provide passive damping for up to several seconds at a time. These periods were too short to obtain accurate measurements of time constants, so the information gained was merely qualitative. PLANNED IMPROVEMENTS One of the major problems with the actuators was that a high percentage of them experienced adhesive failure along the edge joint between the upper and lower bimorph. Since PVDF is a relative of TEFLON, it is not surprising that adhesives are problematic. Alternative bonding techniques, including several types of welding are now being investigated. Higher force levels can theoretically be achieved by increasing the number of layers used, i.e. instead of a two-layer, a "multi-morph" configuration will be used. Progress along this line will depend on the results of the bonding tests. As an alternative to using an accelerometer for deriving the lowfrequency feedback signal, use of a differential circuit applied to the position sensing device signal is being investigated. The difficulty to be overcome here is due to the fact that the differentiated relative position signal is not a direct readout of forces on the suspended box. CONCLUSION The one-dimensional tests have shown that the actuator response matches the predicted response and that the feedback from acceleration and position sensors can be used to induce damping. Flight-testing of a multidimensional system demonstrated that a complete system could be assembled in the volume currently allocated for this purpose while significantly reducing the weight from that of current systems. The experiments that have been completed have shown that these actuators are a viable replacement for the large electromagnets currently being used on the shuttle. Work is ongoing to improve and refine what has been developed to date.

PIEZOELECTRIC POLYMER ACTUATORS [645]/217 ACKNOWLEDGEMENTS This work has been supported by NASA EPSCoR Grant NCCW-0058 and by the Montana Space Grant Consortium. References [l] D. G. Blair, J. Liu, E. F. Moghaddam, L. Ju, Physics Letters A 193 (1994) 223-226