CHEM 221 Instrumental Analysis FINAL EXAM May 10, 2016

Similar documents
CHEM 221 Instrumental Analysis FINAL EXAM May 10, 2016

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

Spectroscopy Problem Set February 22, 2018

Atomization. In Flame Emission

high temp ( K) Chapter 20: Atomic Spectroscopy

The rest of topic 11 INTRODUCTION TO ORGANIC SPECTROSCOPY

NMR = Nuclear Magnetic Resonance

Chemistry 524--Final Exam--Keiderling Dec. 12, pm SES

Lecture 7: Atomic Spectroscopy

Experiment 2 - NMR Spectroscopy

Chem 454 instrumental Analysis Exam 1 February 6 th, 2008

Ch 313 FINAL EXAM OUTLINE Spring 2010

Optical Atomic Spectroscopy

Inorganic Spectroscopic and Structural Methods

NMRis the most valuable spectroscopic technique for organic chemists because it maps the carbon-hydrogen framework of a molecule.

Welcome to Organic Chemistry II

10/2/2008. hc λ. νλ =c. proportional to frequency. Energy is inversely proportional to wavelength And is directly proportional to wavenumber

CHEM*3440. Photon Energy Units. Spectrum of Electromagnetic Radiation. Chemical Instrumentation. Spectroscopic Experimental Concept.

INTRODUCTION Atomic fluorescence spectroscopy ( AFS ) depends on the measurement of the emission ( fluorescence ) emitted from gasphase analyte atoms

Infrared Spectroscopy: Identification of Unknown Substances

very high temperature for excitation not necessary generally no plasma/arc/spark AAS

1. The range of frequencies that a measurement is sensitive to is called the frequency

Emission spectrum of H

1. Cyclic voltammetry involves the measurement of a diffusion controlled at an electrode in which the is controlled. (4 points)

Chem 325 NMR Intro. The Electromagnetic Spectrum. Physical properties, chemical properties, formulas Shedding real light on molecular structure:

12. Structure Determination: Mass Spectrometry and Infrared Spectroscopy

NUCLEAR MAGNETIC RESONANCE AND INTRODUCTION TO MASS SPECTROMETRY

3) In CE separation is based on what two properties of the solutes? (3 pts)

Chapter 12 Mass Spectrometry and Infrared Spectroscopy

7a. Structure Elucidation: IR and 13 C-NMR Spectroscopies (text , , 12.10)

Chemistry Instrumental Analysis Lecture 18. Chem 4631

Analytical Topics to Consider in preparation for the MFAT/GRE

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

Ch. 9 Atomic Absorption & Atomic Fluorescence Spectrometry

CHMC 16 Instrumental Analysis (Syllabus)

2101 Atomic Spectroscopy

Organic Chemistry: CHEM2322

Complete the following. Clearly mark your answers. YOU MUST SHOW YOUR WORK TO RECEIVE CREDIT.

16.1 Introduction to NMR Spectroscopy. Spectroscopy. Spectroscopy. Spectroscopy. Spectroscopy. Spectroscopy 4/11/2013

Classification of spectroscopic methods

Atomic Absorption & Atomic Fluorescence Spectrometry

sample was a solution that was evaporated in the spectrometer (such as with ESI-MS) ions such as H +, Na +, K +, or NH 4

ATOMIC SPECROSCOPY (AS)

Unit 11 Instrumentation. Mass, Infrared and NMR Spectroscopy

Department of Chemistry SUNY/Oneonta. Chem Organic Chemistry I

CH Exam #4 (Take Home) Date Due: 11/25,26/2013

9/13/10. Each spectral line is characteristic of an individual energy transition

Questions on Instrumental Methods of Analysis

CHEM 241 UNIT 5: PART A DETERMINATION OF ORGANIC STRUCTURES BY SPECTROSCOPIC METHODS [MASS SPECTROMETRY]

Nuclear Magnetic Resonance (NMR) Spectroscopy Introduction:

Chemistry 213 Practical Spectroscopy

- 1/2. = kb o = hνν + 1/2. B o increasing magnetic field strength. degenerate at B o = 0

ORGANIC - CLUTCH CH ANALYTICAL TECHNIQUES: IR, NMR, MASS SPECT

UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2004/2005. March KAA 502 Atomic Spectroscopy.

Principles of Molecular Spectroscopy: Electromagnetic Radiation and Molecular structure. Nuclear Magnetic Resonance (NMR)

Lecture 2 nmr Spectroscopy

高等食品分析 (Advanced Food Analysis) I. SPECTROSCOPIC METHODS *Instrumental methods: 1. Spectroscopic methods (spectroscopy): a) Electromagnetic radiation

ORGANIC - CLUTCH CH ANALYTICAL TECHNIQUES: IR, NMR, MASS SPECT

ATOMIC ABSORPTION SPECTROSCOPY (AAS) is an analytical technique that measures the concentrations of elements. It makes use of the absorption of light

Chem 434 Instrumental Analysis Test 1

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

Objective 4. Determine (characterize) the structure of a compound using IR, NMR, MS.

Spectroscopy. Practical Handbook of. J. W. Robinson, Ph.D., D.Sc, F.R.C.S. Department of Chemistry Louisiana State University Baton Rouge, Louisiana

Final Exam. Physical Constants and Conversion Factors. Equations

Partial Energy Level Diagrams

a. An emission line as close as possible to the analyte resonance line

CHEM311 FALL 2005 Practice Exam #3

Chapter 13 Structure t Determination: Nuclear Magnetic Resonance Spectroscopy

Module 13: Chemical Shift and Its Measurement

Structure Determination: Nuclear Magnetic Resonance Spectroscopy

Experiment 11: NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY

Determining the Structure of an Organic Compound

William H. Brown & Christopher S. Foote

What is spectroscopy?

Ultraviolet-Visible and Infrared Spectrophotometry

CHAPTER 3 QUESTIONS. Multiple-Choice Questions

3.15 Nuclear Magnetic Resonance Spectroscopy, NMR

Chapter 15 Lecture Outline

Chapter 9. Nuclear Magnetic Resonance. Ch. 9-1

FLAME PHOTOMETRY AIM INTRODUCTION

SECOND YEAR ORGANIC CHEMISTRY - REVISION COURSE Lecture 2 MOLECULAR STRUCTURE 2: SPECTROSCOPIC ANALYSIS

PRINCIPLE OF ICP- AES

DEPARTMENT OF CHEMISTRY UNIVERSITY OF SWAZILAND

Chapter 13: Molecular Spectroscopy

Spectroscopy in Organic Chemistry. Types of Spectroscopy in Organic

Chem 434 -Instrumental Analysis Hour Exam 1

(2) Read each statement carefully and pick the one that is incorrect in its information.

Chapter 14. Nuclear Magnetic Resonance Spectroscopy

Nuclear Magnetic Resonance

3 - Atomic Absorption Spectroscopy

Atomic Absorption Spectroscopy (AAS)

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy


OAT Organic Chemistry - Problem Drill 19: NMR Spectroscopy and Mass Spectrometry

Chapter 13 Spectroscopy

Nuclear Magnetic Resonance Spectroscopy Thomas Wenzel Department of Chemistry Bates College, Lewiston ME

Spectroscopy. Empirical Formula: Chemical Formula: Index of Hydrogen Deficiency (IHD)

Nuclear Magnetic Resonance Spectroscopy

Nuclear Magnetic Resonance (NMR)

Transcription:

CHEM 221 Instrumental Analysis FINAL EXAM May 10, 2016 Name: Khee INSTRUCTIONS: Read through the entire exam before you begin. Answer all of the questions. For questions involving calculations, show all of your work -- HOW you arrived at a particular answer is MORE important than the answer itself! The entire exam is worth a total of 400 points. Provided are a periodic table and a formula sheet jam-packed with useful stuff! Good Luck! 1

1. QUICKIES - Limit response to about 2 sentences, please! - 20 pts each a. The parent ion peak in the mass spectrum for Br 2 actually consists of more than one peak. How many parent ion peaks would there be for Br 2 and at what masses would they be found? Explain. (There are two stable isotopes of Br ( 79 Br and 81 Br) and they have identical natural abundances.) The two isotopes of Br can combine to form Br 2 in THREE different combos: 79 Br 79 Br - 158 amu 79 Br 81 Br 81 Br 79 Br - 160 amu 81 Br 81 Br - 162 amu Since there is an equal probability of obtaining each of the four combos, they should have abundance ratios of 1:2:1 at masses 158, 160 and 162. b. Explain the differences between the chemical ionization mass spectrum for a compound and its corresponding electron impact ionization mass spectrum. -Decreased fragmentation due to lower energy ionization -Molecular ion peak will occur at either M+1 or M-1 due to addition or abstraction of proton during ionization process. c. Explain why increasing the magnetic field strength results in an increased signal in NMR. -increased magnetic field results in an increase in the energy of the transition ( E B o). According to Bolzmann: N 2/N 1 = e - E/kT So, increasing E will decrease N 2/N 1, allowing more transitions to occur between the two states per unit time (and so, an increased signal). 2

2. Congratulations! After a semester of instrumental analysis, you have been selected as the senior analytical chemist at a local environmental analysis firm. In spite of the fact that they are very understaffed (hence, your inflated starting position), they are remarkably wellequipped and have most of the analytical instruments that we discussed this semester (surprise, surprise!). The methods available include: Flame Atomic Absorption Spectrometry (AAS) Graphite Furnace AAS Flame Atomic Emission Spectroscopy (AES) Inductively Coupled Plasma (ICP) AES ICP-Mass Spec FT-IR Spectroscopy GC-Mass Spec Electrospray Ionization (ESI)- Mass Spec Mass Spectrometry Raman Spectroscopy Molecular Fluorescence Spectroscopy Nuclear Magnetic Resonance (NMR) Hydrodynamic Voltammetry Anodic Stripping Voltammetry a. [20 pts] Your lab has developed a method for quantifying a particular pesticide commonly found in the soil. This method involves an automated extraction followed by an on-line fluorescence measurement at the emission maximum for the pesticide. One of the samples analyzed in this fashion gave a result that showed an unusually large amount of this pesticide in this soil sample. You suspect that this result is not due to an abnormally large pesticide concentration, but is actually due to a problem with the analytical method. Choose ONE technique (from the above list) that you would select to investigate this anomalous result. Briefly justify your choice. Need a separation plus a technique to provide structural info: GC-MS GC: Will confirm sample is a mixture and will separate into component parts MS: Will provide structural info and MW s of the compounds b. [15 pts] From the list of techniques above, choose one that would benefit from the use of the method of internal standards for quantitative measurements. Explain. Most Obvious: GC: corrects for sample introduction variability MS: corrects for sample intro and ionization variability AES: corrects for excitation source temperature variability 3

c. [15 pts] The EPA requires that the cooling water effluent from a local manufacturing plant be monitored for various metals as it is discharged into a stream from which drinking water is obtained. Since the plant still uses Cr in its aluminum oxidation processes, you must test for Cr(VI) in the effluent each day. From the list of methods on the previous page, choose the best one for this analysis; briefly justify your choice. Need a method that will provide oxidation state selectivity: Hydrodynamic Voltammetry (or other Echem method) is the best choice. There are other (acceptable) ways: UV/Vis Spec: Form a metal complex that is specific to Cr(VI) and quantify by measuring absorption spec. Any Atomic Spec: Extract just Cr(VI) and then quantify using AES or AAS d. [20 pts] You've been using a GC with an electron-capture detector (ECD) to quantify the components of a mixture which contain chlorine (think of the ECD as a halogenspecific detector). Alas, the old ECD has decided to cease functioning the day that a new batch of samples arrived for analysis. "No problem!" you tell your boss, "I'll just interface the GC with some other instrument, and we'll be back in business." Unfortunately, the only mass spec in the company is tied up with another project and is unavailable. So, with your new job on the line, what "hyphenated" instrument would you construct (GC-??) -- justify your answer based solely on functionality (i.e., ability to give the information desired). You may choose from any of the instruments listed on the previous page, EXCEPT those that have a mass spec. ECD gave a signal that was specific for halogenated compounds we are specifically interested in Cl-containing compounds So, use an element-specific method that can be selective for Cl: Atomic Spec ICP-AES would work: Measure Cl-emission as chromatogram is run Obtain a chromatogram with ONLY peaks for Cl-containing compounds Even MORE SELECTIVE than the ECD! 4

3. Below are proton NMR spectra of N-sec-butylaniline obtained on 60 MHz and 220 MHz instruments: a. [10 points] Based on the chemical shifts shown, which protons are most heavily shielded? Explain. The 1 protons are most heavily shielded, as they have the smallest chemical shift (0 ppm is defined by TMS, which has very heavily shielded protons). These methyl protons are farthest away from any electron withdrawing groups, so there is very little opportunity for deshielding. 5

b. [15 points] Why are the resonances for the 6 and 7 protons split into 2 and 3 peaks, respectively? Give the expected relative peak areas under the split peaks. Explain. The 7 protons have 2 protons on adjacent carbons which can result in spin-spin splitting, resulting in the following spin alignments: or or. This gives three possible configurations and will split the 7 peak into three peaks with relative areas of 1:2:1. The 6 protons have only one proton on an adjacent carbon which will result in two different spin orientations, splitting the 6 peak into two peaks having identical areas. c. [15 points] Explain why the resonances for the phenyl protons are observed at the greatest chemical shift values for this compound. The phenyl protons (6, 7, and 8) are influenced by the magnetic field generated by the ring current arising from the delocalized electrons circulating the phenyl ring. This magnetic field enhances the applied magnetic field, so these protons on the phenyl ring experience a greater magnetic field than they would if there were no ring current. This results in a shift to a greater frequency (similar to what would be observed for deshielded protons). This effect is referred to as magnetic anisotropy. d. [10 points] If these two NMR spectra were plotted as a function of frequency instead of chemical shift (δ, ppm), explain how the values of the spin-spin coupling constants (J) and how the chemical shift values (remember, in Hz) would be affected by the magnetic field strength of the instrument. Increasing the magnetic field will: 1. Have no effect on J-values, as they depend only on the nuclear spin environment near the proton J values (in Hz) remain unaffected by a change in applied field. 2. Increase absolute chemical shift values (Hz), as the field increase will increase the resonance frequency for each peak (ν and B o). Since all resonance frequencies will be shifted proportionately, the relative shift (ppm) is unaffected. 6

4. QUICKIES - Limit response to about 2 sentences, please! - 20 pts each a. If the C-H stretch for an alkane occurs at 2900 cm -1, to what wavenumber would the absorption band shift for the deuterated analog? ν = (5.3 x 10-12 )(k/µ) ½ Assuming k is constant: ν1/ν2 = (µ2/µ1) ½ 2900 cm -1 /ν2 = (1.8571) ½ µ 1 = [12(1)/(12+1)] = 12/13 µ 2 = [12(2)/(12+2)] = 24/14 µ 2 = 24/14 = 13 = 1.8571 µ 1 12/13 7 ν2 = 2128 cm -1 = 2100 cm -1 b. Briefly explain why spectrofluorometric (emission) measurements are potentially more sensitive than spectrophotometric (absorption) measurements. In spectrofluorometry, detection is ultimately limited by the ability to distinguish between two very small signals (the blank and the emission from a very low concentration sample). In spectrophotometry (absorption), detection is limited by the ability to distinguish between two very LARGE signals (I o and the transmitted signal through a very weakly absorbing sample). Since shot noise is related to the magnitude of the signal, the ability to differentiate between two LARGE signals is considerably less than the ability to differentiate between two SMALL signals. Thus, spectrofluorometric detection limits are lower than corresponding spectrophotometric detection limits. c. Continuum light sources work just fine for molecular absorption spectrophotometry, yet narrow line sources must be used for atomic absorption spectrophotometry Explain. For absorbance spectrophotometry, λeff should be less than 10% of the peak width. For molecules, this is easily attainable with a monochromator ( λeff ~ nm), but for atoms ( λeff ~ 10-3 Å) it is impossible with conventional monochromators, necessitating the use of narrow line sources, such as hollow cathode lamps. 7

5. QUICKIES - Limit response to about 2 sentences, please! - 20 pts each a. When recording the spectrum of a new compound you have just synthesized, you find that a critical spectral feature is buried in the background noise of the spectrum. If, after signal averaging 105 spectra, the S/N for this feature is 0.50, calculate the S/N for this spectral feature after signal averaging the spectrum for an entire weekend (48 hours). Assume that it takes 0.50 minutes to scan a single spectrum. S/N after 105 scans = 0.50 So: (S/N) n=105 = (105) ½ (S/N) n=1 = 0.50 (S/N) n=1 = 0.048795 At 1.0 min/scan, in 48 hours: 48 hours x 60 min x 1 scan = 5.760 x 10 3 scans 1 hour 0.50 min So, S/N after 5.760 x 10 3 scans: (S/N) n = n 1/2 (S/N) n=1 = (5.760 x 10 3 ) 1/2 (0.048795) (S/N) n = (75.895)(0.048795) = 3.703 = 3.7 b. Calculate the frequency of electromagnetic radiation (EMR) in the IR spectral region at a wavelength (in a vacuum) of 7.291 µm. Compare this with the frequency of EMR commonly encountered in NMR spectroscopy and explain why an interferometer is only needed for FT-IR but not FT-NMR. ν = c/λ = 2.9979 x 10 8 m/sec = 4.1117816 x 10 13 sec -1 = 4.112 x 10 13 sec -1 = ν 7.291 x 10-6 m In NMR, the frequencies are in the 10 8 Hz range, which is 100,000 times lower frequency than EMR in the IR. At these lower frequencies (MHz), the oscillations of the EMR can be measured directly, which is not possible at the frequencies encountered in the IR (which then requires an interferometer to modulate the intensity of the EMR at frequencies proportional to the frequencies of the IR EMR). c. Anodic Stripping Voltammetry (ASV) has the best detection limits of any voltammetric methods available today. Briefly outline the steps involved in an ASV analysis and indicate why it has detection limits superior to the other Echem methods we covered. Two steps: 1. Electrolysis: apply potential about 200 mv more negative than the E 0 of the analyte, stir to ensure high rate of reduction; reduced analyte forms an amalgam with Hg, preconcentrating the analyte within the HMDE this is what is responsible for the superior detection limits with ASV. 2. Anodic Linear Sweep Voltammetry. Slow anodic sweep to oxidize analyte in HMDE; measure anodic current (proportional to concentration of analyte) In the measurement process, current is proportional to the concentration of the analyte in the HMDE, which is far greater than the concentration in the much greater volume of the original bulk solution. 8

6. TRUE or FALSE. - 20 pts each Indicate whether the following statements are TRUE or FALSE and briefly explain WHY. a. In a magnetic sector mass analyzer, resolution is limited by the rate at which the magnetic field can be swept. FALSE! Resolution is limited by the spread of kinetic energies of the ions entering the mass analyzer (separation assumes that all ions are accellerated to exactly the same potential). This uncertainty in K.E. translates to an uncertainty in the mass that will pass through the mag sector. b. The flame atomic emission signal from sodium atoms at 589 nm in a sample containing only sodium will increase as an easily ionizable element (such as potassium) is added to the sample. TRUE! Na Na + + e - Adding K results in: K K + + e - This increases the concentration of electrons, shifting the Na ionization equilibrium to the left, increasing the population of Na atoms. So, Na atom emission increases. c. Lock-in amplification is an effective method of improving the S/N of a measurement plagued by environmental noise occurring at a known specific frequency. TRUE! It can be used this way, if the signal can be modulated to a frequency different from that of the noise, then it can be amplified at the modulation frequency (with a specific phase relationship). In this way, in addition to reducing both flicker and white noise, the environmental noise (at the specific frequency) will be reduced in magnitude relative to the signal. FALSE! The sure-fire way to get rid of the environmental noise would be to employ a Fourier Filter, in which the signal is transformed into the frequency domain (via Fourier Transform), where the environmental noise can be isolated and all signal at that frequency eliminated, before performing an inverse Fourier Transform, bringing the signal (without the environmental noise) back to the time domain. 9

7. Still more TRUE or FALSE. - 20 points each, unless stated otherwise. Indicate whether the following statements are TRUE or FALSE and briefly explain WHY. a. Spectral interferences are not experienced with ICP-AES methods; rather, spectral interferences are more of a problem with AAS methods. FALSE! In ICP-AES methods, resolution is determined by the dispersive device (typically a spectrometer), which limits resolution to about 0.1-0.01 Å. In atomic absorption methods, the hollow cathode lamp provides the selectivity, with linewidths that are typically about 0.01-0.001 Å. So, spectral overlap problems in atomic absorption are very unlikely, whereas they can be problematic (for complex materials) in atomic emission methods. b. The ICP is an excellent elemental ionization source for mass spectrometry, even though most elements are only about 0.01% ionized in the ICP. FALSE! While it is true that the ICP is an excellent ionization source for mass spectrometry, most elements are >90% ionized due to the very high temperatures to which atomized samples are exposed to in the ICP. The fraction of elements excited in an ICP is, however, quite low (typically 0.01% or less), but it is a very efficient ionization source. c. [5 pts] Instrumental analysis is my life... TRUE! (always and forever... at least for this semester ) Have a great summer! 10