MODIFIED DIRECT-ZBR METHOD PSO POWER FLOW DEVELOPMENT FOR WEAKLY MESHED ACTIVE UNBALANCED DISTRIBUTION SYSTEMS

Similar documents
A LOOP BASED LOAD FLOW METHOD FOR WEAKLY MESHED DISTRIBUTION NETWORK

Performance analysis and comparison of load flow methods in a practical distribution system

A PROPOSED STRATEGY FOR CAPACITOR ALLOCATION IN RADIAL DISTRIBUTION FEEDERS

CHAPTER 2 LOAD FLOW ANALYSIS FOR RADIAL DISTRIBUTION SYSTEM

PROPOSED STRATEGY FOR CAPACITOR ALLOCATION IN RADIAL DISTRIBUTION FEEDERS

Power Flow Analysis of Radial Distribution System using Backward/Forward Sweep Method

Optimal Placement and Sizing of Distributed Generation for Power Loss Reduction using Particle Swarm Optimization

Optimal Capacitor placement in Distribution Systems with Distributed Generators for Voltage Profile improvement by Particle Swarm Optimization

OPTIMAL LOCATION AND SIZING OF DISTRIBUTED GENERATOR IN RADIAL DISTRIBUTION SYSTEM USING OPTIMIZATION TECHNIQUE FOR MINIMIZATION OF LOSSES

Multiple Distribution Generation Location in Reconfigured Radial Distribution System Distributed generation in Distribution System

Distributed vs Bulk Power in Distribution Systems Considering Distributed Generation

APPLICATION OF FORWARD BACKWARD PROPAGATION ALGORITHM FOR THREE PHASE POWER FLOW ANALYSIS IN RADIAL DISTRIBUTION SYSTEM

OPTIMAL DISPATCH OF REAL POWER GENERATION USING PARTICLE SWARM OPTIMIZATION: A CASE STUDY OF EGBIN THERMAL STATION

Comparison of Loss Sensitivity Factor & Index Vector methods in Determining Optimal Capacitor Locations in Agricultural Distribution

Optimal Placement of Capacitor Banks in order to Improvement of Voltage Profile and Loss Reduction based on PSO

Optimal Capacitor Placement in Distribution System with Random Variations in Load

Optimal DG allocation and sizing in a Radial Distribution System using Analytical Approach

Chapter-2 Literature Review

Harmonic Modeling of Networks

CAPACITOR PLACEMENT USING FUZZY AND PARTICLE SWARM OPTIMIZATION METHOD FOR MAXIMUM ANNUAL SAVINGS

Network Topology Based Back/Forward Sweeping for Load Flow of Radial Distribution Systems

ABSTRACT I. INTRODUCTION

PARTICLE SWARM OPTIMIZATION BASED APPROACH FOR LOSS REDUCTION IN UNBALANCED RADIAL DISTRIBUTION SYSTEM

Application of Teaching Learning Based Optimization for Size and Location Determination of Distributed Generation in Radial Distribution System.

OPTIMAL POWER FLOW BASED ON PARTICLE SWARM OPTIMIZATION

Optimal Placement of Multi DG Unit in Distribution Systems Using Evolutionary Algorithms

Enhanced Newton Method Based Radial Distribution System Load Flow Analysis with Extrapolation Techniques

Optimal Performance Enhancement of Capacitor in Radial Distribution System Using Fuzzy and HSA

Meta Heuristic Harmony Search Algorithm for Network Reconfiguration and Distributed Generation Allocation

A Particle Swarm Optimization for Reactive Power Optimization

Performance Improvement of the Radial Distribution System by using Switched Capacitor Banks

KINGS COLLEGE OF ENGINEERING Punalkulam

A Simplified Approach for Load Flow Analysis of Radial Distribution Network

Optimal Placement & sizing of Distributed Generator (DG)

LOAD FLOW SOLUTION FOR UNBALANCED RADIAL DISTRIBUTION SYSTEMS

METHODS FOR ANALYSIS AND PLANNING OF MODERN DISTRIBUTION SYSTEMS. Salem Elsaiah

Fast Decoupled Power Flow for Unbalanced Radial Distribution Systems

Journal of Artificial Intelligence in Electrical Engineering, Vol. 1, No. 2, September 2012

Optimal Sizing And Placement Of Capacitor In A Radial Distribution System Using Loss Sensitivity Factor And Firefly Algorithm.

Optimal capacitor placement and sizing using combined fuzzy-hpso method

State Estimation and Power Flow Analysis of Power Systems

Incorporation of Asynchronous Generators as PQ Model in Load Flow Analysis for Power Systems with Wind Generation

B.E. / B.Tech. Degree Examination, April / May 2010 Sixth Semester. Electrical and Electronics Engineering. EE 1352 Power System Analysis

FEEDER RECONFIGURATION AND CAPACITOR SETTINGS ON DISTRIBUTION SYSTEMS : AN APPROACH FOR SIMULTANEOUS SOLUTION USING A GENETIC ALGORITHM

International Journal of Mechatronics, Electrical and Computer Technology

ENERGY LOSS MINIMIZATION AND RELIABILITY ENHANCEMENT IN RADIAL DISTRIBUTION SYSTEMS DURING LINE OUTAGES

SSSC Modeling and Damping Controller Design for Damping Low Frequency Oscillations

Power system reconfiguration and loss minimization for a distribution systems using Catfish PSO algorithm

Simultaneous placement of Distributed Generation and D-Statcom in a radial distribution system using Loss Sensitivity Factor

OPTIMAL CAPACITOR PLACEMENT USING FUZZY LOGIC

Optimal Compensation of Reactive Power in Transmission Networks using PSO, Cultural and Firefly Algorithms

J. Electrical Systems x-x (2010): x-xx. Regular paper

DG-Embedded Radial Distribution System Planning Using Binary-Selective PSO

THE loss minimization in distribution systems has assumed

A PARTICLE SWARM OPTIMIZATION TO OPTIMAL SHUNT-CAPACITOR PLACEMENT IN RADIAL DISTRIBUTION SYSTEMS

Network reconfiguration and capacitor placement for power loss reduction using a combination of Salp Swarm Algorithm and Genetic Algorithm

Farzaneh Ostovar, Mahdi Mozaffari Legha

OPTIMAL CAPACITORS PLACEMENT IN DISTRIBUTION NETWORKS USING GENETIC ALGORITHM: A DIMENSION REDUCING APPROACH

1 Unified Power Flow Controller (UPFC)

Optimal Capacitor Placement in Radial Distribution System to minimize the loss using Fuzzy Logic Control and Hybrid Particle Swarm Optimization

Capacitor Placement for Economical Electrical Systems using Ant Colony Search Algorithm

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 03 Issue: 03 Mar p-issn:

Classification of Capacitor Allocation Techniques

EE5250 TERM PROJECT. Report by: Akarsh Sheilendranath

Smart Grid State Estimation by Weighted Least Square Estimation

Fast Decoupled Power Flow to Emerging Distribution Systems via Complex pu Normalization

CHAPTER 3 FUZZIFIED PARTICLE SWARM OPTIMIZATION BASED DC- OPF OF INTERCONNECTED POWER SYSTEMS

Reactive Power Contribution of Multiple STATCOM using Particle Swarm Optimization

A Novel Analytical Technique for Optimal Allocation of Capacitors in Radial Distribution Systems

Optimal Capacitor Placement in Radial Distribution Systems Using Flower Pollination Algorithm

The Existence of Multiple Power Flow Solutions in Unbalanced Three-Phase Circuits

A Comparative Study Of Optimization Techniques For Capacitor Location In Electrical Distribution Systems

OPTIMAL LOCATION OF COMBINED DG AND CAPACITOR FOR REAL POWER LOSS MINIMIZATION IN DISTRIBUTION NETWORKS

Analytical approach for placement and sizing of distributed generation on distribution systems

DISTRIBUTION SYSTEM OPTIMISATION

Fault Location in Distribution Feeders with Distributed Generation using Positive Sequence Apparent Impedance

CAPACITOR PLACEMENT IN UNBALANCED POWER SYSTEMS

EE2351 POWER SYSTEM ANALYSIS UNIT I: INTRODUCTION

A COMPUTER PROGRAM FOR SHORT CIRCUIT ANALYSIS OF ELECTRIC POWER SYSTEMS

Received: 7 October 2015; Accepted: 1 December 2015; Published: 5 December 2015 Academic Editor: Neville Watson

Particle Swarm Optimization. Abhishek Roy Friday Group Meeting Date:

An Adaptive Approach to Posistioning And Optimize Size of DG Source to Minimise Power Loss in Distribution Network

Optimal Unified Power Quality Conditioner Allocation in Distribution Systems for Loss Minimization using Grey Wolf Optimization

Two-Layer Network Equivalent for Electromagnetic Transients

International Journal of Scientific & Engineering Research, Volume 8, Issue 1, January-2017 ISSN

DESIGNING POWER SYSTEM STABILIZER WITH PID CONTROLLER

Selected paper. Particle Swarm Optimization Based Technique for Optimal Placement of Overcurrent Relay in a Power System

Energy Conversion and Management

Operation of the Power Distribution System via Sensitivity Analysis

DISTRIBUTION TRANSFORMERS MODELING WITH ANGULAR DISPLACEMENT - ACTUAL VALUES AND PER UNIT ANALYSIS

Secondary Frequency Control of Microgrids In Islanded Operation Mode and Its Optimum Regulation Based on the Particle Swarm Optimization Algorithm

Single objective optimization using PSO with Interline Power Flow Controller

Elevated Neutral to Earth Voltages Due to Harmonics A T&D Update

SECTION 5: POWER FLOW. ESE 470 Energy Distribution Systems

J. Electrical Systems 10-1 (2014): Regular paper. Optimal Power Flow and Reactive Compensation Using a Particle Swarm Optimization Algorithm

Electrical Power and Energy Systems

OPTIMAL PLACEMENT OF DISTRIBUTED GENERATION AND CAPACITOR IN DISTRIBUTION NETWORKS BY ANT COLONY ALGORITHM

Optimal capacitor placement in radial distribution networks with artificial honey bee colony algorithm

EE 581 Power Systems. Admittance Matrix: Development, Direct and Iterative solutions

STATE ESTIMATION IN DISTRIBUTION SYSTEMS

Transcription:

MODIFIED DIRECT-ZBR METHOD PSO POWER FLOW DEVELOPMENT FOR WEAKLY MESHED ACTIVE UNBALANCED DISTRIBUTION SYSTEMS Suyanto, Indri Suryawati, Ontoseno Penangsang, Adi Soeprijanto, Rony Seto Wibowo and DF Uman Putra Electrical Engineering Department, ITS, Surabaya, Indonesia E-Mail: suyanto13@mhs.ee.its.ac.id ABSTRACT Electrical distribution system is a part of electrical system that is directly connected to the customers. Reliability and power quality of electrical distribution system must be maintained so that they can use electricity continuously. Many methods can be done to improve them of electrical distribution system, such as penetration of Distributed Generations (DG s) and weakly meshed distribution network reconfiguration. These methods will change a passive distribution network to an active one with weakly meshed configuration. Due to the special characteristics of distribution systems, this paper introduces a three phase power flow method that can handle passive/active and radial/weakly meshed distribution networks. The Modified direct-z BR method is developed in this proposed method and combined with Particle Swarm Optimization (PSO). The proposed method is applied to 20 kv distribution network in Surabaya city, East Jawa, Indonesia. Three simulation cases are studied for the test system. The computational speed of three simulation cases shows the number of iterations for these cases are increased but the apparent losses decrease. It means that the proposed method is robust and suitable for weakly meshed reconfiguration. The results show that the proposed power flow method can handle the active unbalanced distribution system with weakly meshed configuration. Keywords: modified Direct-Z BR method, particle swarm optimization (PSO), unbalanced load flow, weakly meshed active distribution networks. INTRODUCTION Due to the special characteristics of electrical distribution systems, this paper introduces a three phase power flow method that can handle passive/active and radial/weakly meshed distribution networks. The Modified direct-z BR method is developed in this proposed method and combined with Particle Swarm Optimization (PSO) and the PSO variation s in existing distribution networks. The interconnection of distributed generations (DG s) to existing distribution networks has gained its importance and altered a distribution network from a passive system to an active one. Distribution systems nowadays are becoming an important part of a power system. Not only because of these systems are directly connected to the consumers, but also these systems have unique characteristics in comparison with transmission systems such as unbalanced loads, high resistance-to-reactance (R/X) ratios, single- or two-phase lines, radial topology, etc. Therefore, threephase load flow methods have been developed for the past twenty years and can be broadly classified into four categories, which are Bus Impedance methods [4], Newton-type methods [5-7], Forward-Backward (FB) and its variations [2, 8-9], and Sequential Power Flow (SPF) methods [10-13]. A three phase load flow method using K-matrix that can handle both passive and active unbalanced radial distribution networks has been developed in [1]. The method combines direct-zbr method and Modified Lambda iteration in handling DG s which are operated as voltage controlled (PV) buses. Many methods can be done to improve reliability and power quality of a distribution system, such as penetration of Distributed Generations (DG s) and weakly meshed distribution network reconfiguration [16-19], [20-21]. The K-matrix, introduced in [2, 14] and also used in [1], is modified in this paper and combined with PSO for solving three phase power flow method that can handle both passive and active unbalanced radial distribution networks with weakly meshed configuration. METHODOLOGY Methodology in this paper is based on simulation of experimental results. The methodology steps consist of the first is K-matrix construction, the second is the modified K-matrix construction. And finally in the proposed method, the K-matrix [1, 2, 14] is modified and combined with PSO and the PSO variation s to handle passive/active and radial/weakly meshed distribution networks. The flow chart of the proposed method is shown in Figure-1. Reference [1] describes the construction of K- matrix in the Direct Z BR power flow method for three phase, radial, passive distribution systems with one and/or two phase lines. For active distribution systems, Modified Lambda iteration is used to estimate reactive power of PVbuses. The following steps describe the modification of K-matrix for weakly meshed distribution systems. 1476

Start Read Data of Distribution Networks PASIVE Check ACTIVE Pasive /Active? Direct ZBR Load Flow Using Modified K- Matrix Direct ZBR Load Flow Using Modified K- Matrix PSO for Var(Q) Tuning Converged? NO YES Load Flow Results Stop Figure-1. Flow diagram of the proposed power flow method. For ease of illustration, a six bus system (shown in Figure-2) is used to describe the modification of K- matrix. The reference bus is bus number 1 and the load (PQ) buses are bus number 2 until 6. B 1,, B6 are the branches/branch currents and B 6 is the branch/branch current which makes the system weakly meshed. In the radial distribution systems with weakly meshed configuration, the loops do not affect the branch currents calculation. These loops make the number of branches increases, and will add the number of branches in the primitive impedance matrix [1]. Step 1: K- matrix construction As described in reference [1,2], the K-matrix of the network shown in Figure-2 without branch B 6 (radial) for branch current calculation is given in Eqn. (1) and Eqn. (2). 1477

VOL. 9, NO. 9, SEPTEMBER 2014 ISSN 1819-6608 (4) Equation 4 can be written as: Figure-2. Simple distribution system with one loop [20]. (5) (1) (2) Eqn. (5) can be expressed as: (6) where, current in branch B6 can be calculated as Eqn.(7). Step 2: Modified K-Matrix construction Branch B6 changes the radial distribution system to a weakly meshed configuration as shown in Figure-2. Current injections in bus 5 and 6 can be calculated as: (3) Therefore, the K-matrix [1] for the six bus system with one loop is: (7) For three phase distribution system, Eqn. (5) can be expressed as shown in Eqn. (8). The modified K-matrix is represented by the addition of [LILC] [B ] in Eqn. (6), and these matrixes ([LILC] and [B ]) represent the loop appearance in a weakly meshed configuration. The flowchart of three phase power flow using direct ZBR method [1, 2] with modified K-matrix is shown in Figure-3. (8) MODIFIED K-MATRIK + PSO POWER FLOW FOR ACTIVE DISTRIBUTION SYSTEMS This paper introduces an application of threephase load flow approach using the direct ZBR method with modified K-matrix which is combined with the Particle Swarm Optimization (PSO). PSO is chosen because it is a robust and simple optimization algorithm [22]. PSO is a heuristic algorithm that inspired by swarm of birds looking for food source [22]. In this paper, PSO is used for tuning the value of reactive power on the buses with specified injected active powers and constant voltage magnitudes (PV buses). PSO variation s performed several types of inertia weight used in this research. In the first experiment, four fixed inertia weights ranging from 0.4 and 0.9 were tested and n in experiment 2 with two types of decreasing inertia weight and a stochastic inertia weight were tested. This experiment is well known as Inertia Weighting Approach PSO (IWA PSO). Figure-4 describes the steps of Modified Kmatrix-PSO power flow algorithm as follows: 1478

Step 1. Input load, line and generation data Step 2. Input PSO parameter Step 3. Random initialization of Var(Q) for each PV bus. Step 4. Run modified K-matrix Power Flow Step 5. Evaluate the fitness Step 6.Getting the best particle (Pbest) and best global particle (Pgbest) Step 7. Update velocity and Position by equation: k 1 k ( k k V + ) i = ωvi + crx 11 Pbesti Xki + ( k k crxgbest ).. + 2 2 i Xi (9) V BUSnl V BUS V BUS X = V + V k+ 1 k k+ 1 i i i (10) k where V i is velocity particle i at k-iteration, ω is weight parameter, c 1, c 2 is acceleration coefficient, r 1, r 2 is k rx random value between 0 until 1, 1 i is particle position at k Pbest k iteration, i is Pbest particle i at iteration-k and k Gbest i is Gbest particle at an i iteration-k. Step 8. Check constrains Qmin and Qmax. Step 9. Check stopping criteria, there are two stopping criteria; maximum iteration and tolerance. Z BR I BUS I BR = K * I BUS V BR= Z BR * I BR V t BUS= V BUSnl + K * V BR V BUS Figure-3. Flowchart of direct Z BR power flow with modified K-matrix. 1479

Start system: Three simulation cases are studied for the test Input Data Random Initialization For Velocity and Var as Position Direct ZBR Load Flow Using Modified K-Matrix Fitness Evaluation & Getting Pbest & Gbest Update Velocity & Position Converged? Load Flow Results End Yes No Figure-4. Flow Chart of K-matrix-PSO power flow. TEST RESULTS The proposed method is applied to one feeder of the 20 kv passive distribution network in Surabaya city, East Jawa, Indonesia. The test system is Basuki Rahmat feeder with tie switches are open and DG s are not connected as shown in Figure-5. The tie switches and DG s are provided for simulation purposes. Case-1: passive radial distribution system. Case-2: passive distribution system with weakly meshed configuration Case-3: active distribution system with weakly meshed configuration a. Case 1 In case 1, the test system is a passive radial system (all tie switches are open and DG s are not connected). Therefore, the Direct Z BR with K-matrix power flow [1,2] is applied here. To verify the method, the results are compared with the commercial ETAP software. The voltage magnitudes and phase angles of phase a, b, and c are in very close agreement with those obtained by ETAP software. b. Case 2 The Direct Z BR with Modified K-matrix power flow (Figure-3) is applied in Case 2 for passive distribution system with weakly meshed configuration. The network configuration and data are the same as that in case 1 except that all the tie switches are closed and DG s are not connected. As in Case 1, the results are compared with the commercial ETAP software. The voltage magnitudes of phase a for all buses are shown in Figure- 6. Similar results as in Case 1 are obtained and for phases b and c as well, demonstrating that the proposed method can accurately solve for a passive distribution network with weakly meshed configuration. c. Case 3 For Case 3, active distribution system with weakly meshed configuration is obtained by closing all tie switches and connecting DG s to bus 6, 16 and 23 as shown in Figure-5. The Direct Z BR with Modified K- matrix + PSO power flow (Figure-4) is applied here. As in Case 1 and 2, to verify the proposed method, the results are compared with the commercial ETAP software. The voltage magnitudes and phase angles of phase b for all buses are shown in Figure-7(a) and (b). It can be seen that the values are very close with those obtained by ETAP Software as in Case 1 and 2, similar results are obtained for the other phases as well which demonstrate that the proposed method can also accurately solve for an active distribution network with weakly meshed configuration. 1480

Figure-5. Basuki Rahmat distribution network. Figure-6. Voltage Magnitudes of phase a for passive distribution system with weakly meshed configuration. 1481

(a) Voltage Magnitude in phase b. (b) Voltage Angle in phase b Figure-7. Voltage Magnitudes and angles of phase b for active distribution system with weakly meshed configuration. CONVERGENCE TEST OF THE PROPOSED METHOD In order to examine the convergence ability of the proposed method, a convergence test was done on the Basuki Rahmad distribution network. Based on three simulation cases above, it has been gained some results by using the proposed power flow method. Firstly, case 1 in passive radial distribution system is convergent in the 10 th iteration and the apparent loss s 0.5 MW. Secondly, case 2 in passive distribution system with weakly meshed configuration is convergent in the 15 th iteration and the apparent loss s 0.45 MW. Finally, case 3 in active distribution system with weakly meshed configuration is convergent in the 18 th iteration and the apparent loss s 0.3 MW. The computational speed of three simulation cases shows the number of iterations for these cases is increased but the apparent losses decrease. It means that the proposed method is robust and suitable for weakly meshed reconfiguration. In order to prove that the proposed method can be utilized in severe conditions, IEEE 33-bus test feeder is used. It likes based on three simulation cases above, it so has been gained same result in the computational speed. CONCLUSIONS The test results show that the proposed power flow method can handle passive/active unbalanced distribution system with weakly meshed/radial configuration. 1482

ACKNOWLEDGEMENTS The authors gratefully acknowledge the support by Indonesian Directorate General of Higher Education. REFERENCES [1] Syai in Mat, Penangsang Ontoseno and Soeprijanto Adi. 2013. Real-time unbalanced load flow development using direct-zbr method and modified lambda iteration for on-line monitoring and control. CIRED, 22nd International Conference on Electricity Distribution, Stockholm. [2] Chen T.H. and N.C. Yang. 2009. Three-phase powerflow by direct ZBR method for unbalanced radial distribution systems. Generation, Transmission and Distribution, IET. 3(10): 903-910. [3] Hatami A.R.a.P.M., M. 2007. Three-Phase Fast Decoupled Load Flow for Unbalnced Distribution Systems. Iranian Journal of Electrical and Computer Engineering. 6(1) (Winter-Spring). [4] Chen T.H., et al. 1991. Distribution system power flow analysis-a rigid approach. Power Delivery, IEEE Transactions on. 6(3): 1146-1152. [5] Baran M. and F.F. Wu. 1989. Optimal sizing of capacitors placed on a radial distribution system. Power Delivery, IEEE Transactions on. 4(1): 735-743. [6] P. A. N. Garcia, J.L.R.P., S. Carneiro, V. M. da Costa and N. Martins. 2000. Three-phase power flow calculations using the current injection method. IEEE Transactions on Power Systems. 15(2). [7] V. M. da Costa, N.M. and J. L. R. Pereira. 1999. Developments in Newton Raphson power flow formulation based on current injections. IEEE Transactions on Power System. 14(4). [8] W.H. Kersting. 2002. Distribution System Modeling and Analysis. CRC Press. [9] J.H. Teng. 2000. A Network-Topology Based Three: Phase Load Flow for Distribution Systems. Proceedings of National Science Council ROC (A). 24(4): 259-264. [12] Kamh M.Z. and R. Iravani. 2010. Unbalanced Model and Power-Flow Analysis of Microgrids and Active Distribution Systems. Power Delivery, IEEE Transactions on. 25(4): 2851-2858. [13] Kamh M.Z. a.i., R. 2011. A unified three phase power flow analysis model for electronically coupled distributed energy resources. IEEE Trans. Power Deliv. 26(2): 899-909. [14] Stagg G.W. 1968. Computer Methods in Power System Analysis. McGraw-Hill. [15] S. Civanlar, J.J Grainger, H. Yin, S.S.H Lee. 1988. Distribution Feeder Reconfiguration for Loss Reduction. IEEE Trans. Power Del. 3(3): 1217-1223. [16] M.E Baran and E.E Wu. 1989. Network Reconfiguration in Distribution System for Loss Reduction and Load Balancing. IEEE Trans. Power Del. 4(2): 1401-1407. [17] S.K Goswami and S.K Basu. 1992. A New Algorithm for the Reconfiguration of Distribution Feeders for Loss Minimization. IEEE Trans. Power Del. 7(3): 1484-1491. [18] Vahid Farahani. 2012. Student Member, IEEE, Behrooz Vahidi, Senior Member, IEEE, and Hossein Askarian Abyaneh, Senior Member, IEEE. Reconfiguration and Capacitor Placement Simultaneously for Energy Loss Reduction Based on an Improved Reconfiguration Method. IEEE Publication. 27(2). [19] Nirbhaykumar Navinchandra, Makwana. 2012. Load Flow Analysis of Radial and Weakly Meshed Distribution System. Thesis, Thapar University. [20] S. Sivanagaraju, J. Viswanatha Rao and M. Giridhar. 2008. A loop based load flow method for weakly meshed distribution network. APRN Journal of Engineering and Applied Sciences. 3(4): 55-59. [21] J. Kenedy. 1995. Particle Swarm Optimization. IEEE Trans. 26(2): 1942-1048. [10] Lo K.L. and C. Zhang. 1993. Decomposed three-phase power flow solution using the sequence component frame. Generation, Transmission and Distribution, IEE Proceedings C. 140(3): 181-188. [11] Abdel-Akher M., K.M. Nor and A.H.A. Rashid. 2005. Improved Three-Phase Power-Flow Methods Using Sequence Components. Power Systems, IEEE Transactions on. 20(3): 1389-1397. 1483