TEST REPORT REPORT NO.: QAV PAGE: 1 OF 31

Similar documents
Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight

TEST REPORT. Test Method : See the attached sheets.

Application of IEC for the assessment of blue light hazard to light sources and luminaires

TEST REPORT. Page 1 of 11

TEST REPORT IEC Photobiological safety of lamps and lamp systems

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

REPORT NO. Projection Lighting Date of Issue: 12/10/11 (Life) Issue G. Description: LED Luminaire Status at: 11/10/11

TEST REPORT IEC Photobiological safety of lamps and lamp systems

Photobiological safety of lamps and lamp systems

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

IEC TR RSZ Guangdong, China. China. shown above and for N.A. None

TEST REPORT IEC Photobiological safety of lamps and lamp systems

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

IEC TR Harrison Huang. China. shown above and for. None

Cat# LED Linear High Bay 100W

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

Photobiological safety of lamps and lamp systems

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada

Cat# LED High Bay

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

TEST REPORT IEC Photobiological safety of lamps and lamp systems

Application. Report. Testing. Testing. China IEC TR Test in. shown. in part without (Dongguan). N.A. Manufacturer... Rating.

solid state LED LED LED LED LED LED Light Emitting Diode: LED LED module Self - ballasted LED module Integral LED module

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

TEST REPORT IEC / EN Photobiological safety of lamps and lamp systems

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

Photobiological safety of lamps and lamp systems

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

Photometric Test Report

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

Photometric Test Report

Morris Products 53 Carey Road, Queensbury, NY 12804

Photobiological safety of lamps and lamp systems

Photometric Test Report

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063

Wet Locations Use 71400A 120 W PF V 2.9A 93% 144 pcs. Philips 130 LM/W 5000K Hrs. 5 Years. 24-1/4 Lbs 665*530*120 1 PCS

IES LM MEASUREMENT AND TEST REPORT For

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A

Photometric Test Report. Keystone Technologies

Photometric Test Report. Keystone Technologies

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

Morris Products 53 Carey Road, Queensbury, NY 12804

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)

LM Test Report. for. Forest Lighting Corporate. LED Tube. Model: FL-T8U BN

LED Entryway Light RoHS

Photometric Test Report

SHP-TS GroLux. SHP-TS 600W GroLux PRODUCT OVERVIEW

LEDs in ERCO luminaires

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire

TEST REPORT IEC Photobiological safety of lamps and lamp systems

Report No 247/ This Report consists of 41 pages

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50

TEST REPORT IES LM For Signlite Opto-electronics Co.,Ltd.

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50

CERTIFIED TEST REPORT No

TEST REPORT IEC Photobiological safety of lamps and lamp systems

LM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W

SHP-T Basic Plus. Sa Shp-T 150w Basic Plus E40 PRODUCT OVERVIEW DATA TABLE. Optical data. Range Features. Colour temperature (K) 2000 CRI (Ra) 20

Test report of IES LM Approved Method: Electrical and Photometric

IES LM TEST REPORT For Shenzhen sunper opto co., ltd

Compliance with the National requirements of EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES for EN 62471:2008.

The official directions are written in Chinese, this English edition is for your reference only -1-

PLWK1595Cx8 COB Series

CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC LVD TEST REPORT

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount. EPA Rating 2.

Photobiological safety of lamps and lamp systems

Lighting Sciences

CLUSTERLITE CONTENTS MEGAMAN

LED Modules. Fortimo LED Strip NA LV4. 24in 2200lm

IES LM TEST REPORT For EIKO GLOBAL, LLC

Test Report. Report No.: EED35I R1. Address : 701 Millennium Boulevard Greenville, SC : P , P , P , P

Test Report. Report No.: EED35I Address : 701 Millennium Boulevard Greenville, SC : P , P , P , P

IESLM-79-08TESTREPORT For KINGLUMI CO., LTD

Product Description HPI-T. Quartz metal halide lamps with clear outer bulb

Report No.: HZ p. (Lumens) Stabilization Time CRI (K)

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LED Modules. Fortimo LED Line

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS Jeanne Han/Safety Manager

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL

Economic and Social Council

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Standard-Tech Co. Ltd Testing Center

Transcription:

QAV Technologies Sdn. Bhd. (616788-U) 116, Lintang Kampung Jawa, NFIZ 3, Taman erindustrian Bayan Lepas, MK 12, 11900 enang, Malaysia. Tel No : 604 643 8317 Fax No : 604 643 8597 Email : qavtech@qavtech.com TEST REORT REORT NO.: QAV-1015-1808 AGE: 1 OF 31 lease refer overleaf for Conditions Relating To The Use Of Test Report. Applicant Address Manufacturer Address roduct : HILIS (M) SDN. BHD. Level 8&9, Menara Axis, No. 2, Jalan 51A/223, 46100, etaling Jaya, Selangor, Malaysia. : hilips (China) Investment Co., Ltd. : No.9, Lane 888, Tian Lin Road, 200233, Shanghai, China : T8 LED Tube (MAS LEDtube) Reference Standard : IEC/AS 62612, Edition 1.0 2009-06 MS 2598: 2014 Minimum Energy erformance Standards Method of test : Compliance with rocedure IEC/AS 62612, Edition 1.0 2009-06 Description of sample :- Brand Name : HILIS Main Model : 9290011785 Model in Series : 9290011786; 9290011787; 9290011788; 9290011789; 9290011790 Rating :- Voltage : 220-240V Frequency : 50/60Hz Wattage : 18W [9290011785; 9290011786; 9290011787] 10W [9290011788; 9290011789; 9290011790] Base : G13 Date Received : 19 th June 2015 Description of overall Test result: -ASS (Refer appendices for details) Issued date : 6 th November 2015 Approved Signatory,.. ( Bin Mohamad Ruskor ) ( See Keat Siang ) Jr roject Engineer Technical Manager

7.0 CONDITIONS RELATING TO THE USE OF QAV TECHNOLOGIES TEST REORT 7.1 A Test Report will be issued in respect of Testing Services conducted and shall relate only to the Sample actually tested. QAV Technologies makes no warranty whatsoever and the Applicant shall not represent in any manner that only duplication or mass roduct is same as Sample actually tested or that QAV Technologies has tested any of the duplicated or mass produced roduct. 7.2 The Test Report shall not be amended, changed, varied or modified in any manner whatsoever by the Applicant or otherwise. 7.3 If the Test Report is to be furnished to any third party or to the public, each such Test Report shall be furnished in full, legible and in its entirety. 7.4 The Test Report shall not be reproduced and shall not in any manner be used for any advertising purposes or whatsoever without written approval from the Managing Director of QAV Technologies of 116 Lintang Kampung Jawa, NFIZ3, Taman erindustrian Bayan Lepas, Mk12, 11900 enang, MALAYSIA. 7.5 Further or in the alternative, it is strictly forbidden unless with prior written approval from the Managing Director of QAV Technologies, to represent in any manner whatsoever that QAV and/or other QAV s subsidiaries has endorsed, approved or validated the roduct of the Applicant in any manner whatsoever. 7.6 The use of QAV Technologies, QAV or other QAV s subsidiaries logo and/or words such as QAV: Tested and roven and similar representations are strictly forbidden in any manner whatsoever without the prior written approval from the Managing Director of QAV Technologies. 7.7 In the event the Applicant is found in breach of this provision, QAV Technologies, QAV or other QAV s subsidiaries without prejudice to any other right and remedies may take whatever action necessary including but not limited to: a) Informing and placing a notice in the media; b) Obtaining an injunction from court (cost on a solicitor-client basis to be borne by Applicant); c) Refusing to accept any further roduct for Testing Services from the Applicant or whosoever related to the Applicant, whether subsidiary or otherwise; d) Instructing the Applicant to withdraw and recall the advertisement, statement or document in question and advertise a clarification and apology to QAV Technologies, QAV or other QAV s subsidiaries twice in national publication of QAV Technologies choice at the Applicant s sole cost; and e) Informing or lodging a report pertaining the Applicant s Test Report with the relevant authorities. 7.8 In the event of an investigation from any third party concerning the Applicant s Test Report, QAV Technologies may disclose the same for purposes of such investigation. 7.9 If such approval is obtained from the Managing Director of QAV Technologies, the Applicant may only include the phrase. A sample of this product has been tested by QAV Technologies (Test Report No.) (dated) (for what test) (to which standard) or such similar words which stress that only the Sample was actually tested. 7.10 Certified true copies of the Test Report may be issued upon request by Applicant upon payment of the relevant fee.

REORT NO.: QAV-1015-1808 AGE: 3 OF 31 SUMMARY OF TESTS: 1. This is a type test report as requested by the applicant. 2. This test report is the QAV test report no. QAV-1015-1808 dated 6 th November 2015 3. This test report covers LED tubes for: 9290011785 9290011786 9290011787 9290011788 9290011789 9290011790 4. All the tests were carried out at the ambient temperature of 25 ± 1 C and the rated voltage / frequency of 220-240V AC 50/60 Hz, unless otherwise specified. ADDITIONAL INFORMATION: Tested by Checked by : Bin Mohamad Ruskor : Lim Sai Seong

REORT NO.: QAV-1015-1808 AGE: 4 OF 31 This Test Report refers only to sample submitted by applicant to QAV Technologies Sdn. Bhd. and tested by QAV Technologies Sdn. Bhd. This test report shall not be reproduced, except in full and shall not be used for advertising purposes by any means or forms without written approval TEST REORT IEC/AS 62612, Edition1.0 2009-06 Self-ballasted LED-lamps for general lighting services erformance requirements Reports Reference No. : QAV-1015-1808 Tested by (name + signature) : Bin Mohamad Ruskor Supervised by (name + signature..: Lim Sai Seong Approved by (name + signature).. : See Kiat Siang Date of issue. : 6 th November 2015 Testing Laboratory : QAV Technologies Sdn Bhd Address : 116, Lintang Kampung Jawa, NFIZ3, Taman erindustrian Bayan Lepas, MK.12, 11900 inang, Malaysia Testing location... : enang Testing location/address... : Same as above Applicant s name : HILIS (M) SDN. BHD. Address. : Level 8&9, Menara Axis, No. 2, Jalan 51A/223,, 46100, etaling Jaya, Selangor, Malaysia Test specification: Standard : IEC/AS 62612, Edition 1.0 2009-06 MS 2598: 2014 Minimum Energy erformance Standards Test rocedure.. : Compliance with rocedure IEC/AS 62612, Edition 1.0 2009-06 and rocedure Deviation. : N/A Non-standard Method.. : N/A Test item description: Trade Mark : Manufacturer. : hilips (China) Investment Co., Ltd. Address. : As above Model/Type reference... : 9290011785; 9290011786; 9290011787; 9290011788; 9290011789; 9290011790 Ratings... : AC 220-240V, [18W, 10W], 50/60Hz

REORT NO.: QAV-1015-1808 AGE: 5 OF 31 Copy of marking plate (sample): Summary of Report: Initial data was taken at initial hours. The test units undergo burn-in test for 1000 hours to meet Suruhanjaya Tenaga (ST) requirements. This report is an preliminary report followed IEC/AS 62612, Edition1.0 2009-06 and also MS 2598: 2014 Minimum Energy erformance Standards for burning 1000 hrs. Full report will be issue after the model complete their test as per require by IEC/AS 62612, Edition1.0 2009-06. A representative sample of the product covered by this report has been evaluated and tested to comply with the requirement of this standard.

REORT NO.: QAV-1015-1808 AGE: 6 OF 31 Test item particulars.: T8 LED TUBE (MAS LEDtube) ossible test case verdicts in this report: -test case does not apply to the test object.....: N/A (Not Applicable) -test object does meet the requirement..: (ass) -test object does not meet the requirement : F (Fail) Testing : Date of received of test item...: 19 th June 2015 Date(s) of performance of tests...: 26 th June 2015 General remarks: This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. This report is not valid as a CCA Test Report unless signed by an approved CCA Testing Laboratory and appended to a CCA Notification of a CCA Notification of Test Result issued by an NCB in accordance with a CCA Group ermanent Documents. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a comma (point) is used as the decimal separator. General product information: This is LED tubes manufacturer by hilips (China) Investment Co., Ltd. The Rating for LED tubes are stated as below: Voltage Frequency Wattage : 220-240 V : 50/60 Hz : 18W; 10W Tested main model: 9290011785 Tested models in series: 9290011786 9290011787 9290011788 9290011789 9290011790

REORT NO.: QAV-1015-1808 AGE: 7 OF 31 IEC/AS 62612, Edition 1.0 2009-06 Clause Requirement + Test Result - Remark Verdict 4 MARKING - mark of origin... : HILIS -model name or model identification... : 9290011785 - rated voltage... : 220-240V - rated input power... : 18W - rated frequency... : 50/60Hz - rated luminous flux...: 2000lm - lamp color code..: N/A - rated life and the related lumen maintenance factor (L x) : 40,000 Hours - failure rate (F x )... : N/A - lumen maintenance category.: N/A - rated correlated color temperature (K)... : 3000K - CCT tolerance category... : N/A - rated color rendition index.....: 83 - location of the making roduct or ackaging 5 DIMENSIONS N/A Length; limit (mm)...: N/A Diameter; limit (mm)...: N/A Others...: N/A Not exceed those of the lamp to be replaced N/A 7 LAM WATTAGE Measured lamp power... : See Appendix A1 The power dissipated by the LED-lamp shall not exceed the rated wattage by more than 15%... : <15% 8 LUMINOUS FLUX Measured total luminous flux (lm)... : See Appendix A1 The initial luminous flux of a LED lamp measured shall not be less than 90% of the rated luminous flux... : > 90%

REORT NO.: QAV-1015-1808 AGE: 8 OF 31 IEC/AS 62612, Edition 1.0 2009-06 Clause Requirement + Test Result - Remark Verdict 9 CORRELATED COLOUR TEMERATURE AND COLOUR RENDERING N/A 9.1 Measured initial CCT... : Measured CCT after an operation time of 25% of rated lamp life (max 6000 hours)... : Not move beyond the CCT tolerance category 9.2 Measured initial CRI... : Measured CRI after an operation time of 25% of rated lamp life (max 6000 hours)... : N/A Not have decreased by more than 5 points from the rated CRI value N/A 10 LAM LIFE N/A 10.1 Lumen maintenance Measured initial luminous flux... : See Appendix A1 Measured luminous flux after an operation time of 25% of rated lamp life (max 6000 hours)... : After 1000 hrs See Appendix A1 The measured flux value after an operation time of 25% of rated lamp life (max 6000 hours) not less than the maximum lumen maintenance related to the rated life The measured lumen maintenance should correspond with the lumen maintenance category > L 80 > Cat B 10.2 Endurance test for built-in electronic ballast N/A 10.2.1 Temperature cycling shock test N/A Supply voltage switching test The LED lamp should operate and remain alight for 15 minutes 10.2.2 The LED lamp should then be operated at test voltage and at an ambient of +45 until a test period equal to 25% of rated lamp life (max 6000 hours) After cooling down to room temperature, the LED lamp should remain alight for at least 15 mins N/A N/A N/A N/A

REORT NO.: QAV-1015-1808 AGE: 9 OF 31 ADDITIONAL OF REQUIREMENT Electricity Regulation 1994 - Minimum Energy erformance Standards (MES) and efficiency rating Table below shows data of testing at 1000 hours. LUMEN MANTAINANCE AT 1000 HRS Table: Data Testing at 1000 Hours Measured initial luminous flux... : Min= 1906.36lm Luminous flux at given time in the life (1000 hrs) divided by the initial value of the luminous flux. Measured lumen maintenance express as percentage (%) : Lumen maintenance of LED after 1000 hrs shall not less than 80%...: The measured lumen maintenance should correspond with the lumen maintenance category FAILURE RATE ercentage of number of tested lamps of the same type that have reached the end of their individual life. Express in term of F x..: Min= 98.01% >L 80 >Cat B F x = 0% Failure rate after 1000 hrs shall not exceed F 10 F 10 EFFICACY The lamp efficacy shall be calculated from the measured luminous flux divided by the measured input power. Measured efficacy (lm/w)... : The efficacy of LED luminaire shall follows Minimum Energy erformance Standards (MES) for lamps... : Min= 101.94lm/W > 75 lm/w From tabulated datas above, the test units pass the requirement state by Suruhanjaya Tenaga (ST) and MES Minimum Energy erformance Standard (MES) for self-ballasted light emitting diode lamps Table: Self Ballasted Light Emitting Diode Lamps for General Lighting Service Lamp Cap Type (as in MS IEC 60061-1) Minimum Efficacy (Lm/W) G13 75 GU10 50 E27 or B22d 60 E14 60

1000 HRS INITIAL REORT NO.: QAV-1015-1808 AGE: 10 OF 31 This Test Report refers only to sample submitted by applicant to QAV Technologies Sdn. Bhd. and tested by QAV Technologies Sdn. Bhd. This test report shall not be reproduced, except in full and shall not be used for advertising purposes by any means or forms without written approval Appendix A1 Model: 9290011785 Data of Testing at Initial Data of Testing at 1000 hours Unit Flux,lm CCT Ra ower (Watt) Efficacy (lm/w) Unit Flux,lm CCT Ra ower (Watt) Efficacy (lm/w) DUT 1 1950.81 3096.00 84.1 19.0 102.67 DUT 1 1911.92 3102.53 84.1 18.9 101.16 DUT 2 1961.92 3090.76 83.1 19.0 103.26 DUT 2 1923.03 3106.30 84.1 19.1 100.68 DUT 3 1950.81 3088.01 83.1 18.9 103.22 DUT 3 1917.47 3107.87 84.1 18.9 101.45 DUT 4 1934.14 3094.98 84.1 18.7 103.43 DUT 4 1900.80 3115.25 84.1 18.8 101.11 DUT 5 1939.70 3089.77 83.1 18.6 104.28 DUT 5 1917.47 3117.55 84.1 18.6 103.09 DUT 6 1928.59 3085.88 83.1 18.7 103.13 DUT 6 1911.92 3112.92 84.1 18.8 101.70 DUT 7 1934.14 3092.40 83.1 18.9 102.34 DUT 7 1923.03 3117.14 84.1 18.9 101.75 DUT 8 1923.03 3093.25 84.1 18.7 102.84 DUT 8 1895.25 3107.84 84.1 18.8 100.81 DUT 9 1950.81 3092.46 84.1 19.0 102.67 DUT 9 1939.70 3118.10 84.1 18.9 102.63 DUT 10 1934.14 3092.05 83.1 18.6 103.99 DUT 10 1923.03 3116.17 84.1 18.7 102.84 DUT 11 1967.48 3096.45 84.1 18.7 105.21 DUT 11 1945.25 3115.05 84.1 18.8 103.47 DUT 12 1945.25 3082.33 83.1 18.8 103.47 DUT 12 1923.03 3106.69 84.1 18.8 102.29 DUT 13 1950.81 3090.20 83.1 18.8 103.77 DUT 13 1934.14 3110.68 84.1 18.7 103.43 DUT 14 1928.59 3088.24 83.1 18.6 103.69 DUT 14 1900.80 3112.18 84.1 18.8 101.11 DUT 15 1945.25 3087.19 83.1 18.7 104.02 DUT 15 1911.92 3101.24 84.1 18.9 101.16 DUT 16 1950.81 3096.96 84.1 19.0 102.67 DUT 16 1917.47 3107.31 84.1 19.0 100.92 DUT 17 1939.70 3086.27 84.1 19.0 102.09 DUT 17 1928.59 3106.93 84.1 18.9 102.04 DUT 18 1961.92 3091.71 84.1 19.1 102.72 DUT 18 1961.92 3109.85 84.1 19.1 102.72 DUT 19 1939.70 3094.94 83.1 18.7 103.73 DUT 19 1911.92 3116.75 84.1 18.8 101.70 DUT 20 1906.36 3086.77 83.1 18.7 101.94 DUT 20 1906.36 3105.85 84.1 18.7 101.94

REORT NO.: QAV-1015-1808 AGE: 11 OF 31 Appendix A2 Figures of model : 9290011785 Outlook view of Test Unit 9290011785 Close-up View of Cap Test Unit 9290011785

REORT NO.: QAV-1015-1808 AGE: 12 OF 31 IEC/AS 62612, Edition 1.0 2009-06 Clause Requirement + Test Result - Remark Verdict 4 MARKING - mark of origin...: HILIS - model name or model identification...: 9290011786 - rated voltage or voltage range...: 220-240V - rated input power...: 18W - rated frequency....: 50/60Hz - rated luminous flux...: 2100lm - lamp colour code...: N/A - rated life and the rated lumen maintenance factor(l x ): 40,000 Hours - Failure rate (F x )...: N/A - lumen maintenance category...: N/A - rated correlated colour temperature...: 4000K - CCT tolerance category...: N/A - rated Colour Rendering Index... : 83 Location of the marking roduct or packaging 7 LAM WATTAGE Measured lamp power... : See Appendix B1 The power dissipated by the LED-lamp shall not exceed the rated wattage by more than 15%... : <15% 8 LUMINOUS FLUX Measured total luminous flux (lm)... : See Appendix B1 The initial luminous flux of a LED lamp measured shall not be less than 90% of the rated luminous flux... : > 90% 10.1 Lumen maintenance Measured initial luminous flux... : See Appendix B1 Measured luminous flux after an operation time of 25% of rated lamp life (max 6000 hours)... : After 1000 hrs See Appendix B1 The measured flux value after an operation time of 25% of rated lamp life (max 6000 hours) not less than the maximum lumen maintenance related to the rated life The measured lumen maintenance should correspond with the lumen maintenance category > L 80 > Cat B

REORT NO.: QAV-1015-1808 AGE: 13 OF 31 Electricity Regulation 1994 - Minimum Energy erformance Standards (MES) and efficiency rating Table below shows data of testing at 1000 hours. LUMEN MANTAINANCE AT 1000 HRS Table: Data Testing at 1000 Hours Measured initial luminous flux... : Min= 1944.65lm Luminous flux at given time in the life (1000 hrs) divided by the initial value of the luminous flux. Measured lumen maintenance express as percentage (%) : Lumen maintenance of LED after 1000 hrs shall not less than 80%...: The measured lumen maintenance should correspond with the lumen maintenance category FAILURE RATE ercentage of number of tested lamps of the same type that have reached the end of their individual life. Express in term of F x..: Min= 98.93% >L 80 >Cat B F x = 0 % Failure rate after 1000 hrs shall not exceed F 10 F 10 EFFICACY The lamp efficacy shall be calculated from the measured luminous flux divided by the measured input power. Measured efficacy (lm/w)... : The efficacy of LED luminaire shall follows Minimum Energy erformance Stanards (MES) for lamps... : Min= 102.89 lm//w > 75 lm/w From tabulated datas above, the test units pass the requirement state by Suruhanjaya Tenaga (ST) and MES Minimum Energy erformance Standard (MES) for self-ballasted light emitting diode lamps Table: Self Ballasted Light Emitting Diode Lamps for General Lighting Service Lamp Cap Type (as in MS IEC 60061-1) Minimum Efficacy (Lm/W) G13 75 GU10 50 E27 or B22d 60 E14 60

1000 HRS INITIAL REORT NO.: QAV-1015-1808 AGE: 14 OF 31 Appendix B1 Model: 9290011786 Data of Testing at Initial Data of Testing at 1000 hours Unit Flux,lm CCT Ra ower (Watt) Efficacy (lm/w) Unit Flux,lm CCT Ra ower (Watt) Efficacy (lm/w) DUT 1 2109.01 4068.00 83.8 18.8 112.18 DUT 1 2097.68 4088.34 84.8 18.8 111.58 DUT 2 2114.68 4071.75 83.8 18.6 113.69 DUT 2 2092.01 4096.67 83.8 18.7 111.87 DUT 3 2120.35 4055.03 83.8 19.0 111.60 DUT 3 2097.68 4094.40 84.8 19.0 110.40 DUT 4 2092.01 4049.82 83.8 18.8 111.28 DUT 4 2086.34 4089.38 84.8 18.7 111.57 DUT 5 1944.65 3826.26 83.8 18.9 102.89 DUT 5 1944.65 3850.97 83.8 19.0 102.35

REORT NO.: QAV-1015-1808 AGE: 15 OF 31 Appendix B2 Figures of model: 9290011786 Outlook View of Test Unit 9290011786 Marking of Test Unit 9290011786

REORT NO.: QAV-1015-1808 AGE: 16 OF 31 IEC/AS 62612, Edition 1.0 2009-06 Clause Requirement + Test Result - Remark Verdict 4 MARKING - mark of origin...: HILIS - model name or model identification...: 9290011787 - rated voltage or voltage range..: 220-240V - rated input power.....: 18W - rated frequency..: 50/60Hz - rated luminous flux...: 2100lm - lamp colour code...: N/A - rated life and the rated lumen maintenance factor(l x ): 40,000 Hours - Failure rate (F x )...: N/A - lumen maintenance category...: N/A - rated correlated colour temperature...: 6500K - CCT tolerance category...: N/A - rated Colour Rendering Index... : 83 Location of the marking roduct or packaging 7 LAM WATTAGE Measured lamp power... : See Appendix C1 The power dissipated by the LED-lamp shall not exceed the rated wattage by more than 15%... : <15% 8 LUMINOUS FLUX Measured total luminous flux (lm)... : See Appendix C1 The initial luminous flux of a LED lamp measured shall not be less than 90% of the rated luminous flux... : > 90% 10.1 Lumen maintenance Measured initial luminous flux... : See Appendix C1 Measured luminous flux after an operation time of 25% of rated lamp life (max 6000 hours)... : After 1000 hrs See Appendix C1 The measured flux value after an operation time of 25% of rated lamp life (max 6000 hours) not less than the maximum lumen maintenance related to the rated life The measured lumen maintenance should correspond with the lumen maintenance category > L 80 > Cat B

REORT NO.: QAV-1015-1808 AGE: 17 OF 31 Electricity Regulation 1994 - Minimum Energy erformance Standards (MES) and efficiency rating Table below shows data of testing for the 1000 hours. LUMEN MANTAINANCE AT 1000 HRS Table: Data Testing at 1000 Hours Measured initial luminous flux... : Min= 2045.24 lm Luminous flux at given time in the life (1000 hrs) divided by the initial value of the luminous flux. Measured lumen maintenance express as percentage (%) : Lumen maintenance of LED after 1000 hrs shall not less than 80%...: The measured lumen maintenance should correspond with the lumen maintenance category FAILURE RATE ercentage of number of tested lamps of the same type that have reached the end of their individual life. Express in term of F x..: Min= 98.89% >L 80 >Cat B F x = 0 % Failure rate after 1000 hrs shall not exceed F 10 F 10 EFFICACY The lamp efficacy shall be calculated from the measured luminous flux divided by the measured input power. Measured efficacy (lm/w)... : The efficacy of LED luminaire shall follows Minimum Energy erformance Standards (MES) for lamps... : Min= 108.79 lm/w > 75 lm/w From tabulated datas above, the test units pass the requirement state by Suruhanjaya Tenaga (ST) and MES Minimum Energy erformance Standard (MES) for self-ballasted light emitting diode lamps Table: Self Ballasted Light Emitting Diode Lamps for General Lighting Service Lamp Cap Type (as in MS IEC 60061-1) Minimum Efficacy (Lm/W) G13 75 GU10 50 E27 or B22d 60 E14 60

1000 HRS INITIAL REORT NO.: QAV-1015-1808 AGE: 18 OF 31 Appendix C1 Model: 9290011787 Data of Testing at Initial Data of Testing at 1000 hours Unit Flux,lm CCT Ra ower (Watt) Efficacy (lm/w) Unit Flux,lm CCT Ra ower (Watt) Efficacy (lm/w) DUT 1 2045.24 6929.00 86.3 18.8 108.79 DUT 1 2050.93 6930.77 86.3 18.7 109.68 DUT 2 2050.93 6923.18 86.3 18.8 109.09 DUT 2 2062.33 6965.96 86.3 18.8 109.70 DUT 3 2056.63 6945.54 86.3 18.8 109.40 DUT 3 2033.85 6973.22 86.3 18.9 107.61 DUT 4 2062.33 6938.14 86.3 18.8 109.70 DUT 4 2050.93 6970.65 86.3 18.8 109.09 DUT 5 2068.02 6935.37 86.3 18.7 110.59 DUT 5 2045.24 6965.10 86.3 18.7 109.37

REORT NO.: QAV-1015-1808 AGE: 19 OF 31 Appendix C2 Figures of model: 9290011787 Outlook View of Test unit 9290011787 Marking of Test Unit 9290011787

REORT NO.: QAV-1015-1808 AGE: 20 OF 31 IEC/AS 62612, Edition 1.0 2009-06 Clause Requirement + Test Result - Remark Verdict 4 MARKING - mark of origin...: HILIS - model name model identification...: 9290011788 - rated voltage or voltage range..: 220-240V - rated input power...: 10W - rated frequency...: 50/60Hz - rated luminous flux...: 1000lm - lamp colour code...: N/A - rated life and the rated lumen maintenance factor(l x ): 40,000 Hours - Failure rate (F x )...: N/A - lumen maintenance category...: N/A - rated correlated colour temperature...: 3000K - CCT tolerance category...: N/A - rated Colour Rendering Index... : 83 Location of the marking roduct or packaging 7 LAM WATTAGE Measured lamp power... : See Appendix D1 The power dissipated by the LED-lamp shall not exceed the rated wattage by more than 15%... : <15% 8 LUMINOUS FLUX Measured total luminous flux (lm)... : See Appendix D1 The initial luminous flux of a LED lamp measured shall not be less than 90% of the rated luminous flux... : > 90% 10.1 Lumen maintenance Measured initial luminous flux... : See Appendix D1 Measured luminous flux after an operation time of 25% of rated lamp life (max 6000 hours)... : After 1000 hrs See Appendix D1 The measured flux value after an operation time of 25% of rated lamp life (max 6000 hours) not less than the maximum lumen maintenance related to the rated life The measured lumen maintenance should correspond with the lumen maintenance category > L 80 > Cat B

REORT NO.: QAV-1015-1808 AGE: 21 OF 31 Electricity Regulation 1994 - Minimum Energy erformance Standards (MES) and efficiency rating Table below shows data of testing at 1000 hours. LUMEN MANTAINANCE AT 1000 HRS Table: Data Testing at 1000 Hours Measured initial luminous flux... : Min= 929.20 lm Luminous flux at given time in the life (1000 hrs) divided by the initial value of the luminous flux. Measured lumen maintenance express as percentage (%) : Lumen maintenance of LED after 1000 hrs shall not less than 80%...: The measured lumen maintenance should correspond with the lumen maintenance category FAILURE RATE ercentage of number of tested lamps of the same type that have reached the end of their individual life. Express in term of F x..: Min= 97.67% >L 80 >Cat B F x = 0 % Failure rate after 1000 hrs shall not exceed F 10 F 10 EFFICACY The lamp efficacy shall be calculated from the measured luminous flux divided by the measured input power. Measured efficacy (lm/w)... : The efficacy of LED luminaire shall follows Minimum Energy erformance Standards (MES) for lamps... : Min= 92.00 lm/w > 75 lm/w From tabulated datas above, the test units pass the requirement state by Suruhanjaya Tenaga (ST) and MES Minimum Energy erformance Standard (MES) for self-ballasted light emitting diode lamps Table: Self Ballasted Light Emitting Diode Lamps for General Lighting Service Lamp Cap Type (as in MS IEC 60061-1) Minimum Efficacy (Lm/W) G13 75 GU10 50 E27 or B22d 60 E14 60

1000 HRS INITIAL REORT NO.: QAV-1015-1808 AGE: 22 OF 31 Appendix D1 Model: 9290011788 Data of Testing at Initial Data of Testing at 1000 hours Unit Flux,lm CCT Ra ower (Watt) Efficacy (lm/w) Unit Flux,lm CCT Ra ower (Watt) Efficacy (lm/w) DUT 1 945.45 3116.00 84.4 10.0 94.55 DUT 1 923.40 3118.58 84.4 10.0 92.34 DUT 2 929.20 3112.49 84.4 10.1 92.00 DUT 2 922.23 3121.89 84.4 10.1 91.31 DUT 3 932.10 3098.57 83.4 10.0 93.21 DUT 3 922.23 3114.89 84.4 10.0 92.22 DUT 4 930.36 3100.02 84.4 9.9 93.98 DUT 4 926.30 3114.95 84.4 9.9 93.57 DUT 5 934.42 3103.15 84.4 10.1 92.52 DUT 5 926.30 3115.48 84.4 10.0 92.63

REORT NO.: QAV-1015-1808 AGE: 23 OF 31 Appendix D2 Figures of Model: 9290011788 Outlook View of Test unit 9290011788 Marking of Test Unit 9290011788

REORT NO.: QAV-1015-1808 AGE: 24 OF 31 IEC/AS 62612, Edition 1.0 2009-06 Clause Requirement + Test Result - Remark Verdict 4 MARKING - mark of origin...: HILIS - model name model identification...: 9290011789 - rated voltage or voltage range..: 220-240V - rated input power...: 10W - rated frequency...: 50/60Hz - rated luminous flux...: 1050lm - lamp colour code...: N/A - rated life and the rated lumen maintenance factor(l x ): 40,000 Hours - Failure rate (F x )...: N/A - lumen maintenance category...: N/A - rated correlated colour temperature...: 4000K - CCT tolerance category...: N/A - rated Colour Rendering Index... : 83 Location of the marking roduct or packaging 7 LAM WATTAGE Measured lamp power... : See Appendix E1 The power dissipated by the LED-lamp shall not exceed the rated wattage by more than 15%... : <15% 8 LUMINOUS FLUX Measured total luminous flux (lm)... : See Appendix E1 The initial luminous flux of a LED lamp measured shall not be less than 90% of the rated luminous flux... : > 90% 10.1 Lumen maintenance Measured initial luminous flux... : See Appendix E1 Measured luminous flux after an operation time of 25% of rated lamp life (max 6000 hours)... : After 1000 hrs See Appendix E1 The measured flux value after an operation time of 25% of rated lamp life (max 6000 hours) not less than the maximum lumen maintenance related to the rated life The measured lumen maintenance should correspond with the lumen maintenance category > L 80 > Cat B

REORT NO.: QAV-1015-1808 AGE: 25 OF 31 Electricity Regulation 1994 - Minimum Energy erformance Standards (MES) and efficiency rating Table below shows data of testing at 1000 hours. LUMEN MANTAINANCE AT 1000 HRS Table: Data Testing at 1000 Hours Measured initial luminous flux... : Min= 966.46 lm Luminous flux at given time in the life (1000 hrs) divided by the initial value of the luminous flux. Measured lumen maintenance express as percentage (%) : Lumen maintenance of LED after 1000 hrs shall not less than 80%...: The measured lumen maintenance should correspond with the lumen maintenance category FAILURE RATE ercentage of number of tested lamps of the same type that have reached the end of their individual life. Express in term of F x..: Min= 99.74% >L 80 >Cat B F x = 0 % Failure rate after 1000 hrs shall not exceed F 10 F 10 EFFICACY The lamp efficacy shall be calculated from the measured luminous flux divided by the measured input power. Measured efficacy (lm/w)... : The efficacy of LED luminaire shall follows Minimum Energy erformance Standards (MES) for lamps... : Min= 95.69 lm/w > 75 lm/w From tabulated datas above, the test units pass the requirement state by Suruhanjaya Tenaga (ST) and MES Minimum Energy erformance Standard (MES) for self-ballasted light emitting diode lamps Table: Self Ballasted Light Emitting Diode Lamps for General Lighting Service Lamp Cap Type (as in MS IEC 60061-1) Minimum Efficacy (Lm/W) G13 75 GU10 50 E27 or B22d 60 E14 60

1000 HRS INITIAL REORT NO.: QAV-1015-1808 AGE: 26 OF 31 Appendix E1 Model: 9290011789 Data of Testing at Initial Data of Testing at 1000 hours Unit Flux,lm CCT Ra ower (Watt) Efficacy (lm/w) Unit Flux,lm CCT Ra ower (Watt) Efficacy (lm/w) DUT 1 966.46 4136.00 84.0 10.1 95.69 DUT 1 966.46 4136.00 84.0 10.1 95.69 DUT 2 984.21 4149.21 84.0 10.0 98.42 DUT 2 981.64 4166.20 84.0 10.0 98.16 DUT 3 971.01 4176.77 85.0 10.0 97.10 DUT 3 971.01 4176.77 85.0 9.9 98.08 DUT 4 996.06 4162.42 85.0 10.2 97.65 DUT 4 996.06 4162.42 85.0 10.1 98.62 DUT 5 992.64 4169.67 85.0 10.1 98.28 DUT 5 992.64 4169.67 85.0 9.9 100.27

REORT NO.: QAV-1015-1808 AGE: 27 OF 31 Appendix E2 Figures of Model: 9290011789 Outlook View of Test unit 9290011789 Marking of Test Unit 9290011789

REORT NO.: QAV-1015-1808 AGE: 28 OF 31 IEC/AS 62612, Edition 1.0 2009-06 Clause Requirement + Test Result - Remark Verdict 4 MARKING - mark of origin...: HILIS - model name model identification...: 9290011790 - rated voltage or voltage range..: 220-240V - rated input power...: 10W - rated frequency...: 50/60Hz - rated luminous flux...: 1050lm - lamp colour code...: N/A - rated life and the rated lumen maintenance factor(l x ): 40,000 Hours - Failure rate (F x )...: N/A - lumen maintenance category...: N/A - rated correlated colour temperature...: 6500K - CCT tolerance category...: N/A - rated Colour Rendering Index... : 83 Location of the marking roduct or packaging 7 LAM WATTAGE Measured lamp power... : See Appendix F1 The power dissipated by the LED-lamp shall not exceed the rated wattage by more than 15%... : <15% 8 LUMINOUS FLUX Measured total luminous flux (lm)... : See Appendix F1 The initial luminous flux of a LED lamp measured shall not be less than 90% of the rated luminous flux... : > 90% 10.1 Lumen maintenance Measured initial luminous flux... : See Appendix F1 Measured luminous flux after an operation time of 25% of rated lamp life (max 6000 hours)... : After 1000 hrs See Appendix F1 The measured flux value after an operation time of 25% of rated lamp life (max 6000 hours) not less than the maximum lumen maintenance related to the rated life The measured lumen maintenance should correspond with the lumen maintenance category > L 80 > Cat B

REORT NO.: QAV-1015-1808 AGE: 29 OF 31 Electricity Regulation 1994 - Minimum Energy erformance Standards (MES) and efficiency rating Table below shows data of testing at 1000 hours. LUMEN MANTAINANCE AT 1000 HRS Table: Data Testing at 1000 Hours Measured initial luminous flux... : Min= 979.84 lm Luminous flux at given time in the life (1000 hrs) divided by the initial value of the luminous flux. Measured lumen maintenance express as percentage (%) : Lumen maintenance of LED after 1000 hrs shall not less than 80%...: The measured lumen maintenance should correspond with the lumen maintenance category FAILURE RATE ercentage of number of tested lamps of the same type that have reached the end of their individual life. Express in term of F x..: Min= 97.66% >L 80 >Cat B F x = 0 % Failure rate after 1000 hrs shall not exceed F 10 F 10 EFFICACY The lamp efficacy shall be calculated from the measured luminous flux divided by the measured input power. Measured efficacy (lm/w)... : The efficacy of LED luminaire shall follows Minimum Energy erformance Standards (MES) for lamps... : Min= 96.29 lm/w > 75 lm/w From tabulated datas above, the test units pass the requirement state by Suruhanjaya Tenaga (ST) and MES Minimum Energy erformance Standard (MES) for self-ballasted light emitting diode lamps Table: Self Ballasted Light Emitting Diode Lamps for General Lighting Service Lamp Cap Type (as in MS IEC 60061-1) Minimum Efficacy (Lm/W) G13 75 GU10 50 E27 or B22d 60 E14 60

1000 HRS INITIAL REORT NO.: QAV-1015-1808 AGE: 30 OF 31 Appendix F1 Model: 9290011790 Data of Testing at Initial Data of Testing at 1000 hours Unit Flux,lm CCT Ra ower (Watt) Efficacy (lm/w) Unit Flux,lm CCT Ra ower (Watt) Efficacy (lm/w) DUT 1 1006.97 7009.00 85.5 10.0 100.70 DUT 1 983.38 7026.62 85.5 10.0 98.34 DUT 2 992.22 7025.15 86.5 10.2 97.28 DUT 2 975.71 7037.77 85.5 10.2 95.66 DUT 3 982.20 7019.36 85.5 10.2 96.29 DUT 3 966.27 7039.34 85.5 10.2 94.73 DUT 4 979.84 7033.29 85.5 10.1 97.01 DUT 4 969.81 7042.74 85.5 10.0 96.98 DUT 5 992.22 7023.30 85.5 10.2 97.28 DUT 5 979.84 7029.90 85.5 10.1 97.01

REORT NO.: QAV-1015-1808 AGE: 31 OF 31 Appendix F2 Figures of Model: 9290011790 Outlook View of Test unit 9290011790 Marking of Test Unit 9290011790