CHAPTER 15 PREPARATION 0? REAGENTS. Since the level of iron in serum is so low, contamination is the most important cause of inaccuracy.

Similar documents
Chapter 9. Volumetric Analysis

not to be republished NCERT YOU are already aware that a substance is analysed to establish its qualitative TITRIMETRIC ANALYSIS UNIT-6

Method for estimation of iodine in urine

SPECIFICATION & TEST PROCEDURE SODIUM SALICYLATE Technical. Molecular weight : Reference : In-house

Standardization of Hydrochloric Acid by Anhydrous Sodium Carbonate

EXPERIMENT. Estimate the strength of given sodium carbonate solution by titrating it against HCl solution using methyl orange as indicator.

General Information 1

Set 4 Marking Scheme: Acid Bases & Salts 2010

Form 4 Chapter 7: Acid and Bases

EXPT. 4 DETERMINATION OF pka OF ORTHOPHOSPHORIC ACID

Volumetric Analysis Acids & Bases HL

Acid-Base Titration. M M V a

Modified Adams Assay for Phenolics in Wine

Partner: Alisa 1 March Preparation and Properties of Buffer Solutions

Chemistry 119: Experiment 6. Sampling and Analysis of a Solid Drain Cleaner

Unit 5 Part 2 Acids, Bases and Salts Titrations, Indicators and the ph Scale UNIT 5 ACIDS, BASES AND SALTS

Titrations. Method for Titration. N Goalby chemrevise.org 1. Using the pipette

The method used to determine the concentration of a known substance using another, standard, solution.

METHOD 9200 NITRATE. 1.2 The applicable range of concentration is 0.1 to 2 mg NO -N per liter. 3 of sample.

NCERT. [H O] Since water is in large excess, its concentration can be assumed to be constant and combining it with K provides a new constant K w

EXPERIMENT 8 A SIMPLE TITRATION

LC-Learn. Leaving Cert Chemistry Notes Higher Level Volumetric Analysis

Experiment 8 Introduction to Volumetric Techniques I. Objectives

AP LAB 13a: Le Chatelier's Principle ADAPTED FROM VONDERBRINK: Lab Experiments for AP Chemistry

Partner: Judy 29 March Analysis of a Commercial Bleach

Name: Date: AP Chemistry. Titrations - Volumetric Analysis. Steps for Solving Titration Problems

Volumetric analysis involving acids and alkalis

LACTIC ACID. The method is applicable to the determination of lactic acid and lactate salts (Note 2) in light or heavy steepwater.

GENERAL PHARMACOPOEIA MONOGRAPH

chemrevise.org 22/08/2013 Titrations N Goalby Chemrevise.org Titrations

Standard Methods for the Examination of Water and Wastewater

HONORS LAB 11a: Le Chatelier's Principle ADAPTED FROM VONDERBRINK: Lab Experiments for AP Chemistry

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Unit 3 Chemistry - Volumetric Analysis

BUREAU OF INDIAN STANDARDS. Draft Indian Standard. SPECIFICATION FOR BASIC CHROMIUM SULPHATE (FOR TANNING) (First revision of IS 6301) ICS:

Dharmapuri LAB MANUAL. Regulation : 2013 Branch. : B.E. All Branches GE6163-CHEMISTRY LABORATORY - I E NG

Experiment 20: Analysis of Vinegar. Materials:

Name of the Experiment: Standardization of Commercial Hydrochloric Acid solution with standard Sodium Hydroxide solution

Chemistry 143 Experiment #11 Acid Base Titration Dr. Caddell. Titrating Acid

Cambridge International Examinations Cambridge Ordinary Level

Cyanide, colorimetric, pyridine-pyrazolone

TITRATION OF AN ACID WITH A BASE

Volumetric Analysis: Acids & Bases OL

Chemistry 143 Acid Base Titration Dr. Caddell. Titrating Acid

for free kcse past papers visit:

Concentration of Solutions

BARINGO KOIBATEX DISTRICTS EDUCATIONAL IMPROVEMENT EXAM 2009 Kenya Certificate of Secondary Education (K.C.S.E)

Synthesis and Analysis of a Coordination Compound

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Advanced Subsidiary Level and Advanced Level

CHEMISTRY PRACTICALS FOR CLASS 10 EXPERIMENT 1

NCEA Chemistry 2.1 Quantitative Analysis AS 91161

TKI CU01 V-1.0_EN Cu separation from irradiated targets 01/12/10

LEAD (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 500 C

Determination of Reducing Sugar Content: Clinitest, Benedict s Solution and the Rebelein Titration

CHEM 132 Lab 11 Western Carolina University

Australian National Titration Competition. Basics of Titration

CHEMISTRY LABORATORY - I

1. Making salt an introduction to some basic techniques Student Sheet

Preparation of Iodoform. Aim : To prepare a pure sample of iodoform. Chemicals : Acetone 5 ml Iodine 5 g NaOH 5 % Methylated spirit

First week Experiment No.1 / /2013. Spectrophotometry. 1. Determination of copper via ammine complex formation using standard series method

Annex 2 Formaldehyde

Chemistry Determination of Mixed Acids

Unit of Pressure (P):Pa Unit of Volume (V): m 3 Unit of Temp (T): K n= moles R = Converting temperature. C K add 273

Section B: Some Essential Background Chemistry

Synthesis of Benzoic Acid

THE CATHOLIC UNIVERSITY OF EASTERN AFRICA A. M. E. C. E. A

GE 6163 CHEMISTRY LAB MANUAL

Name Date Class. Chapter 19 Acids, Bases, and Salts EXPERIMENT. ESTIMATION OF ph PURPOSE BACKGROUND MATERIALS (PER PAIR)

Cambridge International Examinations Cambridge Ordinary Level

For this lab, you will determine the purity of the aspirin by titration and by spectrophotometric analysis.

9.1 Qualitative Analysis

Chemistry SPA Experiment Planning. Scientific Experiments

O H 3 O 1 1 A. O 1 1 OH (K w

# 12 ph-titration of Strong Acids with Strong Bases

Edexcel GCSE Chemistry. Topic 3: Chemical changes. Acids. Notes.

National standard of People s Republic of China

EXPERIMENTAL DETAILS

Acid-Base Titration Acetic Acid Content of Vinegar

MANUAL ON ENGINEERING SCIENCE LAB II (2007)

1.22 Concentration of Solutions

DR/4000 PROCEDURE SELENIUM. 4. Measure 100 ml of sample into a second 500-mL erlenmeyer flask (label the flask sample ).

Paper Reference. Wednesday 18 January 2006 Morning Time: 1 hour

She carries out two experiments.

Acid / Base Titrations

Learn to do quantitative titration reactions. Observe the mole ratios of several simple chemical reactions.

#13 ph-titration of Weak Acids with Strong Bases

4-4 Chemical changes Chemistry

Write the ionic equation for this neutralisation reaction. Include state symbols.

DETERMINATION OF CHEMICAL OXYGEN DEMAND COD

Errors. Accuracy and precision

Section Four Structured questions

LAB 8: DETERMINATION OF ACETIC ACID CONTENT IN VINEGAR

(a) What name is given to this method? (1) (b) Which piece of apparatus should be used to measure the 25.0cm 3 of KOH?

In this laboratory exercise we will determine the percentage Acetic Acid (CH 3 CO 2 H) in Vinegar.

Chemistry Assessment Unit AS 3

CHEMISTRY CORE PRACTICALS

NEUTRALIZATION TITRATION-2 TITRATION OF AN ANTACID (Exp. 4)

Experiment 10 Acid-Base Titrimetry. Objectives

EXPERIMENT A7: VINEGAR TITRATION. Learning Outcomes. Introduction. Upon completion of this lab, the student will be able to:

Acids and Bases 2 Science Notes JC-Learn. JC-Learn. Science Notes Acids and Bases 2. 1 P a g e

Transcription:

CHAPTER 15 PREPARATION 0? REAGENTS Since the level of iron in serum is so low, contamination is the most important cause of inaccuracy. Therefore, a great care should he taken to avoid any possible iron contamination during the preparation of reagent which are to be used for the purpose of serum iron estimations. It may also be necessary to discard certain batches of reagents if they produce a strong colour in the Blank. REAGENTS TO BE PREPARED (1) 1 N Oxalic acid. (2) 1 N Sodium hydroxide. (3) Alkaline acetate solution. (4) Trichloracetic acid (60#W/V). (5) 1 N Hydrochloric acid. (6) 0.0l N Hydrochloric acid. (7) Ascorbic acid solution. (8) Dipyridyl reagent. (9) Iron-free water. 254

255 IMPORTANT CONSIDER ATI CBS (1) All the reagents must be of "Anala-R" Grade U.B.Grade) (free from iron-contamination). (2) The various ingredients should be weighed accurately on an analytical balance. (3) All the reagents and solutions should be made with iron-free water (triple glass-distilled water). (4) The reagents and solutions should be stored in previously prepared "iron-free1* glass-stoppered reagent bottles. (5) All the bottles should be labelled properly, corked tightly and preserved carefully. (6) A labelled pipette should be kept SEPARATE for each reagent and must be used only for that particular reagent/solution. PREPARATION OF SOLUTIONS (l) IN Oxalic acid solution : Normal oxalic acid solution is used for preparing normal sodium hydroxide. This is because Oxalic acid is a very stable substance and can be weighed very accurately. Hence, the normal solution can be prepared easily, accurately and is stable (i.e. remains for a long time as such) so that it can be used for standardising normal sodium hydroxide

256 solution at any time. Formula : ( C00H)2.2HgO (Crystalline Oxalic acid) The equivalent weight of Oxalic acid follows s COOH COONa 2NaOH + \ = 1 COOH COONa 90 (Anhydrous Oxalic acid) (Sodium Oxal ate) + 2H20 Hence, the equivalent weight of anhydrous oxalic acid is 90/2 = 45. The equivalent weight of crystalline Oxalic 90+36 126 acid is ------------ = ---- = 63. 2 2 Therefore, 63 gm. of crystalline oxalic acid when dissolved in water to give l litre of final solution will give Normal solution of oxalic acid. Method s A watch glass was weighed accurately on an analytical balance. Then 6.3 gm. of crystalline oxalic acid was weighed accurately in this watch glass. The oxalic acid used was of C.P. grade (chemically pure grade) or of A.R. grade reagent (Analytic al/gr ade). The oxalic acid so weighed was transferred to a 100 ml. flask through a funnel. The washings of the watch glass, funnel and sides of the flask were added. Some more distilled water was also added and the oxalic acid was dissolved

257 by shaking. The volume was made to 100 ml. by adding more distilled water, and the solution was stirred well. The normal solution was thus ready. (2) IN Sodium Hydroxide Solution ; Sodium hydroxide was supplied in form of small pellets, srfctofltjr* It is deliquescent substance and absorbs moisture and carbon dioxide from air so rapidly that it becomes liquid and forms sodium carbonate. It always contains some carbonate.hence, this substance cannot be weighed accurately. (If one tries to weigh it accurately, during the time required, it absorbs considerable moisture and carbon dioxide from air). The equivalent weight of sodium hydroxide is found from the following equation* HC1 4 NaOH = NaCl 4 HgO 36.46 40 Hence, equivalent weight cf NaOH is 40. At first the solution is always to be prepared more concentrated than what is required so that afterwards the required concentratm& ion can be accurately adjusted by necessary dilution. Method : The watch glass was weighed. Then, approximately (not accurately) 20.5 gm. of sodium hydroxide pellets t** were weighed. (NaOH is handled with forceps). 50 ml. of triple glass-distilled water was taken in a beaker

258 which was then kept in a cold water basin. (The beaker was kept in cold water because much heat is evolved - it being an exothermic reaction when NaOH is added to water). The weighed NaOH was transferred to the beaker quickly. It was allowed to cool. During this period it dissolved by Itself. (The beaker was not shaken lest NaOH may absorb COg from air). The contents of the beaker were transferred to a 500 ml. volumetric flask. The volume was made to 500 ml. by adding triple glass-distilled water. This approximately IN NaOH solution was standardised against IN Oxalic acid solution.1 STANDARDISATION AGAINST IN OXALIC ACID SOLUTION 2 NaOH COOH iooe loona OONa + 2HgO 2 x 40 2 x 45 (Anhydrous oxalic acid) Hence 40 gm. of NaOH is drous oxalic acid, or to 63 gm. equivalent to 45 gm. of anhy- of crystalline oxalic acid... 1000 ml. of IN NaOH» 10Q0 ml. of IN oxalic acid..*. 20 ml. of IN NaOH * 20 ml. of IN oxalic acid. Procedure i 20 ml. of IN oxalic acid was measured accurately, and transferred to flask. 1-2 drops of phenolphthalein as indicator were added. (Phenolphthalein gives colourless appearance in acidic medium and pink sad colour in basic medium). Approximate ln NaoH was -aken in burette.

259 Development of persistant pinkish colour marked the end point. The amount of 1 N NaOH solution required was noted. (This should be less than 20 ml. because instead of 20 gm. 20.5 gm. of NaOH was added to 500 ml. This approximately IN NaOH solution is always to be prepared more concentrated than normal solution so that it can be easily adjusted to normal by dilution. If it is more dilute than normal solution, NaOH will have to be added to it and then to be titrated again). Results of First Titration : TABLE NO. 17 STANDARDISATION AGAINST 1 N OXALIC ACID SOLUTION Obs. Amount of Approx. 1 N NaOH solution in No. 1 N oxalic Burette acid solutlon in Initial Final Diffe- Mean tor flask reading read- rence read- (in ml.) (in ml) ing (in ml) (in ml.) ing iln ml) 1. 20.0 0.0 19.4 19.4 Phenol- 19.4 phthal- 2. 20.0 2.0 21.4 19.4 ein. The end point was marked by development of persistent pinkish colour.

260 The end point was reached at 19.4 ml. of approximate 1 N NaOH solution... Every 19.4 ml. of approximate 1 N NaOH solution s 20 ml. of (exact) 1 N NaOH solution... 19.4 ml. of approximate l N solution should be diluted to 20 ml, to give exactly 1 N solution... 194 ml, of approximate 1 N solution should be diluted to 200 ml. This dilution was carried out accordingly. Then, it was retitrated against 1 N oxalic acid solution for confirmation. Results of Second Titration : TABLE NO. 18 STANDARDISATION AGAINST IN OXALIC ACID SOLUTION Obs. Amount of Approximate 1 N NaOH solution No, 1 N oxalic in Burette acid soln. --- Indic- in flask Initial Final Diffe- Mean ator (in ml.) reading read- re nee read- (in ml.) iug(ml)(in ml) Ing(aa) 1. 20.0 0.0 20.0 20.0 Phenol- 20.0 phthal- 2. 20.0 5.0 25.0 20.0 ein. The end point was marked by development of persistent pinkish colour.

261 Thus., the diluted NaOH solution was retitrated similarly against 20 ml. of 31* oxalic acid solution to confirm that exactly 20 ml, of IN NaOH solution neutralised 20 ml. of IN oxalic acid solution. The standardisation of 3N NaOH solution is also possible by using oxalic acid crystals. But the use of oxalic acid solution is more convenient and accurate because the solution once prepared can be used for any number of titration, without any chances of variation in the strength acid of oxalic/s olu ti on. (3) Alkaline Acetate Solution : Alkaline acetate solution is prepared by saturating vkth IN Sodium hydroxide solution (vide supra) with mm solid sodium acetate (26 gm. of solid sodium acetate per 100 ml. of IN sodlim hydroxide solution). Deposits are formed at the bottom of the bottle. Portions of solution* are removed for use without disturbing the deposits. (4) 300 gm. of trichloracetic acid was weighed out accurately and transferred to a 600 ml. volumetric flask. The washings were added to the flask. The volume was made to 600 ml. by adding triple - glass - distilled water. The contents after stiiring well were transferred to the reagent bottle.

262 (5) l N Hydrochloric Acid solution s The commercial cone. Hydrochloric acid has 1.19 sp. gr. and contains about 36# Hcl. by weight (i.e.36 gm. of Hcl. in 100 gm. of the cone.acid.) 100 ml. of cone, acid will weigh 100 x 1.29 * 119 gm. But 100 gm. of cone, acid solution contains 36 gm.of acid. 119 gm. of cone, acid solution will contain 119 x 36 --------= 46.74 gm. of acid. 100 i.e. 100 ml. of cone, acid solution contains 46.74 gm.of acid, «.. Approx. 79 ml. of cone, acid solution contains 36.46 gm. of acid... to prepare a slightly stronger solution than normal, 90 ml. of cone. HC1 were measured in a graduated measuring cylinder. (This was done in a hood because fumes are disagreeable) and was added to 1 litre volumetric flask containing 800 ml. of cold triple-glass-distilled water. (A strong acid or alkali is to be added to water,and not water to the acid or alkali. The reaction of acid or alkali with water is exothermic and much heat is evolved. Hence, to keep the temperature as low as possible, acid car alkali is added to water which is first taken in the container.) It was diluted to the markacsl with triple-glass-distilled water, and was mixed well. This approximate 1 N solution of HCl (slightly stronger than narmal)w*s

263 standardised against pure anhydrous sodium carbonate (C.P.) by using Methyl Orange as an indicator (yellow in basic medium and or^ange in acidic medium), or it may be standardised against 1 N NaOH solution by using Phenolphthalein as an indicator (colourless in acidic medium and pink in basic medium). Standardisation against 1 N NaOH Solution : HC1 + NaOH s NaCl + HgO 36.46 40 1000 ml. of IN NaOH = 1000 ml. of 1 N HC1... 20 ml. of 1 N NaOH «20 ml. of 1 N HC1. HC1 was taken in flask and phenolphthalein was used as an indicator. Be suits of First Titration : STANDARDISATION TABLE NO. 19 AGAINST 1 N NaOH SOLUTION Obs. No. Amount of approx. UN HCl. in flask, (ml) 1 N NaOH solu^:ion in Burrette Initial reading (in ml7 Final reading (in ml.i Difference (in ml) Mean (in ml) India cat or 1. 20.0 0.0 21.3 21.3 Phenol- 21.3 phthal- 2. 20.0 3.0 24.3 21.3 ein. The end point was marked by development of persistent pinkish colour.

264.. Every 33.0 ml. of approx. 1 N HC1 «21.3 ml. of (exact) IN HC1... Every 20.0 ml. of approximate 1 N HC1 should he diluted to 21.3 ml. to give 1 N HC1. Accordingly, the dilution vas carried out and the normality was confirmed by retitra~ing it against 1 N NaOH solution. Results of the Second Titration : TABLE NO. 20 STANDARDISATION AGAINST 1 N NaOH SOLUTION Obs. No. Amount of (exact) 1 N HC1. in flask, (ml.) 1 N NaOH Solution in Burette Indicator Initial Pinal Diffe- Mean re ading reading (ml.) rence (ml.) (ml.) (ml.) 1. 20.0 2.0 22.0 23.0 2. 33.0 0.0 20.0 20.0 20,0 Phenolphthaleln The end point was marked by development of persistent pinkish colour. Thus, 1 N HC1 solution was ready for the use. (6) 0.Oi N Hydrochloric acid solution : This was prepared by 1 in 100 dilution of 1 N hydrochloric acid with triple-glass-distilled water.

265 (7) As cor Me acid Solution : 0.25 gm. of ascormc acid was weighed out accurately on an analytical balance and was transferred carefully to a small test tube. It was dissolved in ikx 3 ml. of 1 N Hydrochloric acid solution. The tube was shaken well till the ascorbic acid dissolved completely. The solution is was prepared FRESHLY Each Day. (8) Dipyrldyl Solution : 0.2 gm. of ascorbic acid and 0.02 gm. of 2 s 2' Dipyridyl (Anala - R Grade) were weighed out accurately on Mettler Balance (Photograph No.89) as follows : Weight 0.153 gm. paper slip + 0.200 gm. ascorbic acid 0.353 Total + 0.020 gm. Dipyrldyl. 0.373 Total weight Then it was transferred to a small "Iron-free te.st tube, containing 4 ml. of triple-glass-distilled water. It was mixed well till a clear solution was obtained. The solutionwfes made FRESHLY each day. (9) Iron-free Water : The iron-free' water is one of the most important and commonest requirements for Serum Iron Estimations. The

266 triple-glass-distilled water was used for the purpose. It was prepared by distillation of water in a metal apparatus, then re-distillation in an all-glass apparatus and again re-redistilletion in an all-glass apparatus. The bottles of water triple-glass-distilled/should be corked nicely,labelled properly and preserved carefully. Main Reagents required for Serum Iron Estimation with s SEPARATE labelled pipette for each reagent.

268 Requirements for preparing Stock Iron Standards PROCEDURE (l) Stock Iron Standard : An "iron-free" -watch g]ass was weighed accurately on an analytical balance. Then exactly 21.59 gm. of Ferric ammonium sulphate (A.R.) was weighed out accurately. The contents of the watch glass were carefully transferred to a 500 ml. volumetric flask through an "iron-free" funnel. Tfte washings of the watch glass, funnel and sides of the flask were added. 50 ml. of concentrated hydrochloric acid (A.R.) and some amount of triple-glass-distilled water were added to the flask. Ferric ammonium sulphate was dissolved by shaking til] a transparent clear solution was obtained. More triple-giss-distilled water was added to make the volume to 500 ml. It was transferred

269 to a iron-free reagent bottle. The stock iron standard solution was thus ready, containing 5 mg. (5000 meg.) Fe per 100 ml. The stock iron standard solution was preserved in a Brown coloured screw capped bottle in refrigerator. The brown colour of the bottle prevents the action of light on the contents cf the bottle when the latter :* is exposed to light. The bottle should be kept in refrigerator immediately after the use. The refrigerator favourably supplies low temperature and darkness. (2) Dilute Iron Standard : by The dilute iron standard was prepared/l in 10 dilution of stock standard solution with 0.01 N hydrochloric acid. Hence exactly 1 ml.of stock iron standard was pipetted out in a test tube or 50 ml. beaker containing 9 ml. of 0.01 N HC1. The

270 s ij 2nci or cl contents were mixed well. The dilute iron/solution thus prepared contains 500 meg. Fe per 100 ml. Preparation of Dilute standard (D.S.) a (3) Working Iron Standard : The working iron standards were prepared by diluting exactly 0.2 ml. and 0.4 ml. respectively of dilute iron standard to 100 ini. with 0.01 N hydrochloric acid. Preparation of working standard (W.S.)

271 The two working iron standards (S^ and Sg) thus prepared contains 100 and 200 meg. Fe per 100 ml. respectively. The working iron standards (3^ and Sg) are to be prepared f/$rom stock iron standard freshly each time. Alternatively, if the working iron standards( and Sg) prepared above are preserved carefully in brown coloured screw capped bottles in refrigerator, the same may be readily used as and when r equired. Preservation of and S The use of ready made working standards saves much time and labour to be spent at each set of experiment.simultaneous use of fresh working standards and stored working standards during the course of present study has given practically the same results.

273 to each flask respectively and the volume In each flask was made to 100 ml. by adding 0.Oi N HC1. (1) Amount of dilute iron standard (containing 500 meg. %) in ml. (2) Final volume to be made (by adding 0.01 N HCl) in ml. S1 S2 S3 S4 ss 0.1 o.a 0.3 0.4 0.5 100 100 100 100 100 (3) Iron concentration in meg. per 100 ml. 50 100 150 200 250 Progressive Dilution of Dilute Iron Standard After the dilution, the contents of each flask were mixed thoroughly by shaking. It was not possible for the pipette to enter the narrow mouth of flask. Therefore,five iron-free test tubes were taken and labelled as Si, S2, S3, S4 and S5. The five different working iron standards prepared above were transferred to these test tubes respectively.

274 A test tube containing triple-glass-distilled water (Blank) was also included. PROCEDURE Twelve small test tubes (3" x l/2 ) were arranged on a copper rack in two rows of six each. Each row of six test tubes was labelled as B, Si, 835 S3, S4 and S5. Copper rack with labelled tubes

13 Development of Different Colour Intensities (l2) Measure the optica], density in Beckman Spectrophotometer at 520 m u, using the Blank soluticn(distilled water Blank) to set the instrument to zero. RESULTS Five such experiments were run and the results of each experiment are given in separate tables along with the Iron Standard Curve (chapter 26). 276