EXPERIMENTAL STUDY ON MOISTURE TRANSFER THROUGH FIREFIGHTERS' PROTECTIVE FABRICS IN RADIANT HEAT EXPOSURES

Similar documents
A DELAYED FRACTIONAL MODEL FOR COCOON HEAT-PROOF PROPERTY

A Report F.I.E.R.O. Total Heat Loss and Evaporative Resistance Measurements of Eight Firefighter Composites. Report #HP

THE EVALUATION OF MOISTURE PERMEABILITY FOR WATERPROOF BREATHABLE OVERCOAT ON WEARING CONDITON

NUMERICAL APPROACH TO INTER-FIBER FLOW IN NON-WOVENS WITH SUPER ABSORBENT FIBERS

Full Ensemble and Bench Scale Testing of Fire Fighter Protective Clothing

A PREDICTIVE MODEL OF THERMAL CONDUCTIVITY OF PLAIN WOVEN FABRICS

Investigation of the Thermal Insulation Properties of Multilayer Textiles

A Heat Transfer Model for Fire Fighter s Protective Clothing

AN ADSORPTION ISOTHERM MODEL FOR ADSORPTION PERFORMANCE OF SILVER-LOADED ACTIVATED CARBON

SONG, GUOWEN. Modeling Thermal Protection Outfits for Fire Exposures. (Under the

IGNITABILITY ANALYSIS USING THE CONE CALORIMETER AND LIFT APPARATUS

HEAT TRANSFER ANALYSIS OF INSULATION MATERIALS WITH FLEXIBLE MULTILAYERS

Radiant heat transfer network in the simulated protective clothing system under high heat flux

Background Commonly Used Fabric Tests Thermal Physical Test Methods Objective Limitations Conclusions 9/16/2016

SFI TECHNICAL BULLETIN 3.2 EFFECTIVE: FEBRUARY 26, 2014 *

FLAME RETARDANCY AND ULTRAVIOLET RESISTANCE OF SILK FABRIC COATED BY GRAPHENE OXIDE

GLOWING AND FLAMING AUTOIGNITION OF WOOD

International Journal of Advance Engineering and Research Development

INFLUENCE OF WATER-SOAKING TIME ON THE ACOUSTIC EMISSION CHARACTERISTICS AND SPATIAL FRACTAL DIMENSIONS OF COAL UNDER UNIAXIAL COMPRESSION

DYEING BEHAVIOR PREDICTION OF COTTON FABRICS IN SUPERCRITICAL CO 2

Physics 221, March 22

Peltier Application Note

Short Communications

Modeling Exposures of a Nylon-Cotton Fabric to High Radiant Heat Flux

STUDY OF TRANSIENT HEAT TRANSFER OF A SOLID WITH PROTECTIVE FABRIC UNDER HOT AIR JET IMPINGEMENT

AN ANALYTICAL THERMAL MODEL FOR THREE-DIMENSIONAL INTEGRATED CIRCUITS WITH INTEGRATED MICRO-CHANNEL COOLING

Heat Transfer in Single-side Napped Fabrics During Compression

A new method for estimating the effects of thermal radiation from fires on building occupants. Torvi, D. A.; Hadjisophocleous, G. V.; Hum, J.

TEST METHOD TO MEASURE SURFACE VOLTAGES CREATED ON TRIBOCHARGING INHABITED GARMENTS

International Fire Safety Symposium 2015

RELIABILITY TEST DATA SAFETY STANDARD RECOGNIZED CERAMIC CAPACITOR

GEOGRAPHY EYA NOTES. Weather. atmosphere. Weather and climate

Hygrothermal Properties and Performance of Sea Grass Insulation

DEVELOPMENT OF THE MEASURING SYSTEM FOR ANALYSING THE THERMAL PROPERTIES OF CLOTHING

Research Article Predicted Thermal Sensation Index for the Hot Environment in the Spinning Workshop

Modeling Human Thermoregulation and Comfort. CES Seminar

Cone Calorimetric Study of Gangue Flame Retardance of PVC

Investigation of the Thermal Transfer Behavior of Single Layer Woven Fabrics at Different Temperatures

Indoor Environment Quality. Study the world Capture the elements Environmental testing made easy. MI 6201 Multinorm. MI 6401 Poly.

APPLICATION OF ZEOLITE FAU FOR FLAME- RETARDANT FINISHING OF CELLULOSE

Documentation of the Solutions to the SFPE Heat Transfer Verification Cases

Intro to Thermodynamics. With Angry Birds Physics Feb 2014 J. Tobler

Characteristics and Definitions Used for Film Capacitors

SPORTSCIENCE sportsci.org News & Comment: Exercise Physiology A Spreadsheet for Partitional Calorimetry

Preliminary Experimental Study on Heat Transfer Characteristics of Wall with Automatic Adjustment of Heat Transfer Coefficient

WUFI Workshop at NTNU /SINTEF Fundamentals

Solid Liquid Gas 1. Solids have a fixed volume and a definite shape.

Study on the In-situ Coating by Octadecylamine of Pyrotechnically Generated Aerosol Particles for Fire Suppression

Heat Transfer. Conduction, Convection, and Radiation. Review: Temperature

Review: Radiation Heat Transfer through Fire Fighter Protective Clothing

Surface Mount UV LED. NUVA33 Series PART NUMBERING SYSTEM. WAVELENGTH CODES Code Nominal Wavelength

Measurement of wettability for polymer materials using non-contact surface resistivity

Where is the tropical zone? What are three biomes found in the tropical zone?

Science Chapter 13,14,15

The Study of Dynamic Monitor of Rice Drought in Jiangxi Province with Remote Sensing

THERMAL AND SORPTION STUDY OF FLAME RESISTANT FIBERS

Test Report No: RJ Date: September 23, The Client submitted and identified the following test material as Polytec Shutter.

Fig 1. Power Tower during Operation

Trevira Bioactive * For a plus in cleanliness and freshness. Workwear Hospital textiles. Functional apparel. Flame retardant Home textiles

COMPUTATION MODEL OF SHIELDING EFFECTIVE- NESS OF SYMMETRIC PARTIAL FOR ANTI-ELECTRO- MAGNETIC RADIATION GARMENT

Module 2. Measurement Systems. Version 2 EE IIT, Kharagpur 1

LE Accumulation, Net Radiation, and Drying with Tipped Sensors

Large scale diesel oil burns

Transactions on Engineering Sciences vol 5, 1994 WIT Press, ISSN

Where is the tropical zone? What are three biomes found in the tropical zone?

WOOD FRACTURE PATTERN DURING THE WATER DESORPTION PROCESS ABSTRACT

Chapter 5 Test. Directions: Write the correct letter on the blank before each question.

MODELING THE THERMAL DECOMPOSITION OF POLYMER/CARBON NANOTUBE NANOCOMPOSITES

Available online at ScienceDirect. Energy Procedia 69 (2015 )

INVESTIGATION ON CALIBRATION SYSTEM FOR CONDUCTIVE HEAT FLUX GAGES


Mapping the Baseline of Terrestrial Gamma Radiation in China

Sorption isotherms for textile fabrics and foam used in the indoor environment

MODIFICATION OF COTTON MATERIAL WITH PRECURSORS OF SILICON ALKOXIDES FOR IMPROVED FLAME RETARDANCY

Trevira Bioactive * For a plus in cleanliness and freshness. Workwear Hospital textiles. Functional apparel. Flame retardant Home textiles

Supplemental Information. Storage and Recycling of Interfacial. Solar Steam Enthalpy

TEST REPORT. Date. W. O. No.

Biological Process Engineering An Analogical Approach to Fluid Flow, Heat Transfer, and Mass Transfer Applied to Biological Systems

Table of Contents. Chapter: Atmosphere. Section 1: Earth's Atmosphere. Section 2: Energy Transfer in the Atmosphere. Section 3: Air Movement

Department of Mechanical Engineering, University Visvesvaraya College of Engineering, Bangalore University, Bangalore, Karnataka, India

Heat Tracing Basics. By: Homi R. Mullan 1

AN INVESTIGATION OF HEAT FLOW THROUGH KAPOK INSULATING MATERIAL

Activity 13 Planner. Activity 13 Summary. Activity Subject and Content Objective Materials. Just Dew It! Dew point Determine the dew point of the air.

6480(Print), ISSN (Online) Volume 4, Issue 7, November December (2013), IAEME ENGINEERING AND TECHNOLOGY (IJARET)

Metallized polyester film capacitors MKT 470

PHYSICS LICENCE. 6 Marks

An Introduction to Insulation Resistance Testing

MCS 7 Chia Laguna, Cagliari, Sardinia, Italy, September 11-15, 2011

Cold and freeze protection of blueberries in Florida. Dr. Dorota Z. Haman Agricultural and Biological Dept. University of Florida

Xioanan, Ren, Zong, Ruowen, Hu, Yuan, Siuming, Lo, Stec, Anna A and Hull, T Richard

Analytical study of the heat loss attenuation by clothing on thermal manikins under radiative heat loads

UN Regulation No. 118 Annex 8

Numerical Simulation for Flow and Heat Transfer Characteristics of L- Type Chaotic Channel

Method of Thickness Optimization of Textile Structures During Coupled Heat and Mass Transport

THE NEAR-WELLBORE PRESSURE CALCULATION MODEL INCORPORATING THERMOCHEMICAL EFFECT

UNIT TEST PRACTICE TEST

Study on Mathematics Model of Leather Creeping Behavior in Lastometer Deformation States

Relationship between the characteristics of cationic polyacrylamide and sewage sludge dewatering performance in a full-scale plant

The Sun and Water Cycle

APPENDIX 1 DESCRIPTION OF HOT WIRE ANEMOMETER

Transcription:

THERMAL SCIENCE, Year 2017, Vol. 21, No. 4, pp. 1665-1671 1665 EXPERIMENTAL STUDY ON MOISTURE TRANSFER THROUGH FIREFIGHTERS' PROTECTIVE FABRICS IN RADIANT HEAT EXPOSURES by Meng CHEN, Fanglong ZHU *, Qianqian FENG, Kejing LI, and Rangtong LIU College of Clothing, Zhongyuan University of Technology, Zhengzhou, China Original scientific paper https://doi.org/10.2298/tsci160512051c The effects of absorbed moisture on thermal protective performance of firefighters clothing materials under radiant heat flux conditions were analyzed in this paper. A thermal protective performance tester and temperature sensor were used to measure the temperature variations for the facecloth side of four kinds of commonly used flame retardant fabrics in several radiant heat exposures, which varied in moisture content. Experimental results showed that, all of the temperature profiles of these four kinds of moistened fabrics under different radiant heat flux conditions presented the same variation trend. The addition of moisture had a positive influence on the thermal protective performance during the constant temperature period when heat radiation time was more than 60 seconds. As the heat radiation time increased beyond 500 seconds, the thermal protective performance of moistened fabrics became worse than that of dried fabrics in general. Key words: flame retardant fabrics, thermal protective performance, moisture content, radiant heat flux Introduction Firefighters usually have to be exposed to heat radiation produced by fire or hot air while firefighting and thermal protective clothing is crucial to work and for survival for firefighters in extreme environments. The scene of firefighting is not a dry environment, in which some moisture would exist, such as fire water, perspiration produced by sweating firefighters or rains. After these moistures being absorbed by firefighters clothing materials, it will play an important role on the thermal protective performance (TPP) of the materials [1]. Chen [2] tested the temperature of simulated skin under wet and dry fabric layer exposed to radiant heat flux. It was found that the temperature of simulated skin under wet fabric layer was higher than that under dry fabric layer, but the opposite trend appeared with time extending. Perkins [3] tested the distribution of temperature on the surface of protective fabrics exposed to a radiant heat flux of 16.8 kw/m 2. The results showed that the TPP of wet fabrics was better than dry fabrics. Barker et al. [4] measured TPP of turnout system exposed to a heat flux of 6.3 kw/m 2 and pointed out that the addition of moisture negatively impacts the predicted * Corresponding author, e-mail: zhufanglong_168@163.com

1666 THERMAL SCIENCE, Year 2017, Vol. 21, No. 4, pp. 1665-1671 burn protection to the greatest degree when the moisture is added at a comparatively low level of approximately 15% of turnout composite weight. Wang et al. [5] analyzed the influence of outer fabric of firefighters uniform under wetting condition on its TPP. It was observed that the thermal protection performance (TPP) value of the outer fabric tends to increase as its wetting degree increasing. Li [6] tested the TPP value of fabrics in different wet state exposed to a heat flux of 82.21 kw/m 2. It was revealed that moisture contributes to improve the TPP of single layer fabric. Fu et al. [7] conducted thermal manikin experiments with two kinds of multi-layer protective garments in hot environment, which varied in different sweating rates of manikin and ambient humidity ranges. It demonstrated that the internal and external moisture difference influenced the time needed to form the microenvironment, which impact the TPP greatly. This research was conducted to investigate the impacts of absorbed moisture on the ability of firefighters clothing materials to protect against heat exposures by evaluating the temperature variations for the facecloth side of four kinds of commonly used flame retardant fabrics having different moisture content exposed to heat radiation. Materials and methods Materials Four kinds of commonly used flame retardant fabrics were selected and their basic parameters were shown in tab. 1. Table 1. The basic parameters of four kinds of flame retardant fabrics Fabric samples Composition Texture Thickness [mm] Weight [gm 2 ] Fab. 1 50% nomex + 50% viscose twill 0.41 190 Fab. 2 100% nomex interlock 0.95 210 Fab. 3 93% nomex + 5% kevlar + 2% static wire twill 0.49 200 Fab. 4 100% cotton plain stitch 0.57 210 Methods The experiments were conducted with these four kinds of fabrics exposed to radiant heat flux of 5, 20, and 40 kw/m 2. Motis TPP tester was used to provide heat source and Testo temperature tester was applied to test the temperature for the facecloth side of sample fabrics. The moisture content gradients were set as 0, 15, 25, 50, 75, 100, 125, and 150%. Only the experiments of the first six kinds of moisture content were conducted with Fab. 3 due to its poor hygroscopicity. The fabric samples were cut into the size of 140 140 mm. Sufficient water was then sprayed onto the facecloth side of the dry specimen to increase its weight by the desired amount, which was calculated according to the following equation after precise weigh of dry weight: M w = M d (1 + φ) (1) where M d and M w are the dry weight and wet weight of the fabric sample, and ϕ is the moisture content.

THERMAL SCIENCE, Year 2017, Vol. 21, No. 4, pp. 1665-1671 1667 Results and discussion The TPP of these fabrics containing different amount of moisture could be observed through the trend of temperature variations in the same heat condition. Figure 1 illustrated the trend of temperature variations for the facecloth side of these fabrics exposed to a radiant heat flux of 5 kw/m 2 and fig. 2 showed the duration of keeping a constant temperature of these fabrics exposed to this radiant heat flux. Figure 1. The trend of temperature variation of the four kinds of fabrics exposed to radiant heat flux of 5 kw/m 2 It could be seen from fig. 1 that all of the temperature profiles for the facecloth side of these four kinds of moistened fabrics presented same variation trend. As the heat source being turned on, the temperature rose rapidly. After a short period of time, the rising rate gradually slowed down then remained stable (between 35 and 40 C) but began to rise again later. When the heat radiation time was beyond 500 seconds, the temperature showed slight change close to stable. Figure 2 revealed that the higher moisture content ϕ, the longer the temperature keeping constant at a relative low temperature. That means the existence of moisture increases the heat storage capacity of fabrics, which has a positive effect on TPP. The higher the moisture content, the better TPP of fabrics in this stage.

1668 THERMAL SCIENCE, Year 2017, Vol. 21, No. 4, pp. 1665-1671 Figure 2. The duration of keeping a constant temperature of the four kinds of fabrics exposed to radiant heat flux of 5 kw/m 2 The trend of temperature variations for the facecloth side of the four kinds of fabrics exposed to radiant heat fluxes of 20 kw/m 2 and 40 kw/m 2 were illustrated in figs. 3 and 4. The duration of keeping a constant temperature of these fabrics exposed to the two radiant heat fluxes were presented in figs. 5 and 6. By contrasting figs. 1, 3, and 4, it can be found that the curves of temperature variations for the facecloth side of the four kinds of fabrics exposed to the three different radiant heat flux presented same variation trend. The temperature for the facecloth side of fabrics rose more quickly with the enhancement of radiant heat flux. Besides, the temperature after being stable at last was higher when exposed to a higher radiant heat flux. It can be observed in figs. 5 and 6 that the law that the higher moisture content, the longer the temperature keeping constant at a relative low temperature remained unchanged when Figure 3. The trend of temperature variation of four kinds of fabrics exposed to radiant heat flux of 20 kw/m 2

Chen, M., et al.: Experimental Study on Moisture Transfer through THERMAL SCIENCE, Year 2017, Vol. 21, No. 4, pp. 1665-1671 1669 Figure 4. The trend of temperature variation of four kinds of fabrics exposed to radiant heat flux of 20 kw/m2 Figure 5. The duration of keeping a constant temperature of the four kinds of fabrics exposed to radiant heat flux of 20 kw/m2 Figure 6. The duration of keeping a constant temperature of the four kinds of fabrics exposed to radiant heat flux of 40 kw/m2 exposed to radiant heat flux of 20 kw/m2 and 40 kw/m2. By contrasting figs. 2, 5, and 6, it can be found that the duration of keeping a constant temperature shortened as the enhance-

1670 THERMAL SCIENCE, Year 2017, Vol. 21, No. 4, pp. 1665-1671 ment of radiant heat flux. So in conclusion, the situation when exposed to radiant heat flux of 20 kw/m 2 and 40 kw/m 2 were consistent with the situation in radiant heat flux of 5 kw/m 2 except that the temperature rose more quickly, the duration of keeping a constant temperature was shorter and the temperature after being stable was higher. Therefore, high radiant heat environment has a higher request for TPP of fabrics. Figure 7. The influence laws of moisture content ϕ on TPP of fabrics The average temperature for the facecloth side of fabrics during 500 to 600 seconds were took as reference data of their TPP to compare the influence laws in different radiant heat exposures. Figure 7 showed the influence laws of moisture content on TPP in different test conditions. It indicated that these influence laws were not the same when exposed to different radiant heat flux. The temperature for the facecloth side of moistened fabrics was higher than dried fabrics in each radiant heat exposures in general, namely the TPP of moistened fabrics was worse than dried fabrics. Conclusion All of the temperature profiles for the facecloth side of moistened flame retardant fabrics under different radiant heat flux conditions presented the same variation trend. The TPP enhanced with the increase of moisture content when the heat radiation time is more than

THERMAL SCIENCE, Year 2017, Vol. 21, No. 4, pp. 1665-1671 1671 60 seconds. While when heat radiation time increased beyond 500 seconds, the TPP of moistened fabrics became worse than that of dried fabrics in general. Consequently, the absorbed moisture will execute different impacts on the TPP of flame resistant fabrics in different periods of heat radiation. Besides, the moisture will played different roles when exposed to different radiant heat flux. Acknowledgment This study was financially supported by the National Natural Science Foundation of China (51576215), and a joint project between the Henan-Province and the National Natural Science Foundation of China (U1304513). References [1] Rossi, R., Fire Fighting and Its Influence on the Body, Ergonomics, 46 (2003), 10, pp. 1017-1033 [2] Chen, N. Y., Transient Heat and Moisture Transfer to Skin through Thermally Irradiated Cloth,MIT, Cambridge, Mass., USA, 1959, pp. 1-10 [3] Perkins, R. M., Isolative Values of Single-Layer Fabrics for Thermal Protective Clothing, Textile Research Journal, 49 (1979), 4, pp. 202-216 [4] Barker, R. L. et al., Effects of Moisture on the Thermal Protective Performance of Firefighter Protective Clothing in Low-Level Radiant Heat Exposures, Textile Research Journal, 76 (2006), 1, pp. 27-31 [5] Wang, Y. Y. et al., Thermal Protective Performance of Home-Made New Fabrics for Firefighters Protective Clothing, China Textile Leader Journal, (2008), 8, pp. 98-100 [6] Li, H. Y., Testing and Analysis on Wet Thermal Protective Performance of Single Layer Fabrics, Journal of Textile Research, 30 (2009), 12, pp. 53-97 [7] Fu, M. et al., Effects of Moisture Transfer and Condensation in Protective Clothing Based on Thermal Manikin Experiment in Fire Environment, Procedia Engineering, 62 (2013), pp. 760-768 Paper submitted: May 12, 2016 Paper revised: August 28, 2016 Paper accepted: November 3, 2016 2017 Society of Thermal Engineers of Serbia. Published by the Vinča Institute of Nuclear Sciences, Belgrade, Serbia. This is an open access article distributed under the CC BY-NC-ND 4.0 terms and conditions.