State - of - the -art C18 HPLC Columns

Similar documents
State-of-the-art C18 HPLC Columns

InertSustainSwift C8

Inertsil Technical Library

InertSustainSwift C8

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties

The Evolving HPLC Column Packings

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Inertsil. Catalogue 9. Hichrom Limited

Shodex TM ODP2 HP series columns

ACE Ultra Inert Base Deactivated HPLC Columns

Advantages of polymerbased. an alternative for ODS

Inertsil ODS-EP Technical Information

Comparison Guide to C18 Reversed Phase HPLC Columns

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

Packings for HPLC. Packings for HPLC

Too Polar for Reversed Phase What Do You Do?

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

The Selection of an HPLC Column October

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

Method Development Kits

Alltech Alltima HP Introduction

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

mau 200 ph min

William E. Barber, Ph.D. Applications Chemist October

Choosing Columns and Conditions for the Best Peak Shape

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

Epic Aromatic Selectivity

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

Technical Guide Thermo Scientific Syncronis HPLC Columns

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

ImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Optical Isomer Separation Columns and Packing Materials

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Analyze Nucleotides, Nucleosides, Purine, and Pyrimidine Bases Simultaneously with the Ultra IBD Column

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Sample Preparation TLC Plates

Gemini-NX Performance paired with Axia Technology

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs)

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted

General Hydrosphere C Ordering Information

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

penta-hilic UHPLC COLUMNS

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

Hypersil BDS Columns TG 01-05

LC Technical Information

AQUASIL C18 Columns. AQUASIL 18 Columns TG Compatible with 100% aqueous mobile phase

Optimisil HPLC & UPLC Column catalogue

The Standard for ph Method Development

HPLC UHPLC Columns. Dikma Technologies Inc.

Evaluation of a novel glass vial overcoming adsorption effect for pharmaceutical drugs

ColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

General YMC Hydrosphere C Ordering Information

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Reversed Phase Solvents

INERTSIL (GL Sciences)

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Shim-pack GIST/GISS/GIS/GWS Series

New Product Update. HPLC Columns

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

LC and LC/MS Column Selection Flow Chart

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

Acclaim Mixed-Mode WCX-1

Fast Separation of Vastly Different Compounds by Isocratic HPLC

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Part 2. Overview of HPLC Media

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Packed columns for reversed-phase chromatography TSKgel ODS-100V and 100Z

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Overview Applications of NUCLEODUR HPLC Phases

Comparison of different aqueous mobile phase HPLC techniques

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

First Prebiotic Generation of a Ribonucleotide from Adenine, D Ribose and Trimetaphosphate

Value of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

for Acclaim Mixed-Mode WCX-1

for Acclaim Trinity TM P1

ADVANTAME (TENTATIVE)

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Reversed Phase Chromatography: Mobile phase Considerations

penta-hilic UHPLC COLUMNS

ADVANTAME. Not less than 97.0% and not more than 102.0% on the anhydrous basis. Sweetener, flavour enhancer

HPLC Column Material - Bulk Ware

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

HPLC Method Development with Eclipse Plus: Standard Practices and New Columns. Agilent Technologies

It s hot! ZIC -chilic

8. Methods in Developing Mobile Phase Condition for C18 Column

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

ACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC

Do you need trouble-free speed? The NEW Chromolith HR

Transcription:

An HPLC GL Sciences Newest and Most Advanced ODS Phase -New For State - of - the -art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with % Aqueous s Distributed in Australia & New Zealand WINLAB PTY LTD PO Box, Brendale, Queensland, Australia Ph + () Email sales@winlab.com.au Web www.winlab.com.au

Ultimate deactivation techniques enabling the highest inertness with the silica base HPLC column allow analyses of trace amount of most demanding basic and acidic compounds. Enhanced deactivation has made the column feature much easier to use! Enhancing Sensitivity and High Separation Efficiency Strictly classified particle size with narrow distribution width and ideally designed carbon loading and its procedure allow us to guarantee the high plate count of +,/m. Combined with synergistic effect from the improved peak shapes based on the highest inertness of packing material, Inertsil ODS- can be used as a tool for enhancing sensitivity and high separation efficiency. Excellent peak shapes for both strong acidic and basic compounds Our newly-developed endcapping technique ideally deactivates the silanol groups, suppressing the adsorption of common basic compounds as well as strong ones, which leads to sharper peaks. Moreover, the new endcapping technique prevents the adsorption of strong acidic compounds as a surface of the packing material becomes neutral. Excellent analysis stability of strong metal chelating compounds Excellent analysis stability under % aqueous eluents Inertsil ODS- minimizes the dewetting phenomenon while maintaining the same retention characteristics to that of common ODS columns. Therefore, Inertsil ODS- can be used at ease under % aqueous eluents. Furthermore, the packing material that achieves a stable analysis using % aqueous eluents provides another advantage which reduces the column equilibration time returning to an initial eluent condition in gradient. In order to stably analyze strong metal chelating compounds, samples were injected repeatedly before the analysis to mask the adsorption active sites on the surface of the packing material or addition of EDTA to the eluent were required. equilibration was also time-consuming. Since the trace amount of metals has been eliminated from the surface of the packing material, it allows a stable analysis from the st injection requiring no masking process. Bonded Phase Structure C H Silica gel Highly-pure spherical silica gel Pore volume. ml/g Purity.% Bonded phase Octadecyl group Particle size µm, µm Endcapped Yes Surface area m/g Carbon loading % Pore size Å ( nm) USP Code L Australia & New Zealand contact info@winlab.com.au or call + ()

Comparison of inertness to Dextromethorphan between Inertsil ODS- and commercially available ODS columns Dextromethorphan, a strong basic compound, can be adsorbed by trace amount of residual silanols on the surface of the packing material, resulting in poor peak shapes with the traditional endcapping technique. Due to its newly-developed powerful deactivation, adsorption of compounds are much less and thus enables highly qualitative analysis of strong basic compounds. Symmetry C SunFireTM C Atlantis T GL- HPLC system μm,. mm I.D. A CHCN B mm KHPO ph. ; mm KHPO A/B = /, v/v. ml/min UV nm Injection Vol.. μl. Phenol. mg/ml. Dextromethorphan hydrobromide. mg/ml Dextromethorphan N H O Luna C () ZORBAX Eclipse Plus C HypersilTM GOLD Analysis of Antihistamines by LC/MS/MS Antihistamines are strongly basic and therefore will easily be adsorbed to the residual silanols on the packing material, resulting in deterioration of peak shapes. Generally, in HPLC analysis of strong basic compounds, highly-concentrated buffer or ion-pair reagents are introduced to the eluent to prevent adsorption of strong basic samples on the packing material. However, in LC/MS (/MS), such eluent conditions are not recommended and a packing material with superb inertness is required. Inertsil ODS- prevents the adsorption of strong basic compounds without using the above mentioned eluents. This feature also makes Inertsil ODS- an ideal column for LC/MS (/MS) as well..e.e.e.e.e.e Intensity, cps.e.e.e.e.e.e.e.e.e.e.e.e.e. Time, min. Chlorpheniramine.. Cinnarizin.. Clemastine.. Difenidol.. Diphenhydramine.. Diphenylpyraline.. Hydroxyzine.. Promethazine.. Triprolidine. LC HPLC system Q TRAP Inertsil ODS - μm,. mm I. D. A CH OH B mm CH COONH A/B = / - min- / - min - /. ml/min LC/MS/MS ESI, Positive, MRM Injection Vol. μl Australia & New Zealand contact info@winlab.com.au or call + ()

Comparison of inertness to Brilliant Blue FCF between Inertsil ODS- and commercaily available ODS columns Brilliant Blue FCF, a strong acidic compound, will easily be absorbed if the surface of the packing material shows slightly basic. Symmetry C, SunFire C, and Atlantis T shown in the figures below, which completely elute weak acids, still have compounds remain uneluted and produce poor peak shapes, due to the adsorption to the packing material. Inertsil ODS-, as the surface of the packing material is neutral, does not adsorb even strong acid and produce good peak shapes. Adsorbtion Adsorbtion of peak of peak Symmetry C SunFireTM C Atlantis T GL- HPLC system μm,. mm I.D. A CHCN B.% HPO A/B = /, v/v. ml/min UV nm Injection Vol.. μl. Brilliant Blue FCF. mg/ml. Phenol. mg/ml. Salicylic acid. mg/ml Brilliant Blue FCF N+ N Adsorbtion of peak Luna C () ZORBAX Eclipse Plus C SO- SO- SO- Hypersil GOLDTM Analysis of Haloacetic Acids by LC/MS/MS Haloacetic acid is a harmful substance generated when tap water is chlorinated. With its strong acidity, it is easily adsorbed at basic sites on the surface of the packing material. High-sensitivity analysis by LC/MS (/MS) have received attention in these years. In accordance with the popularity, a column free of adsorption has been greatly required since the adsorption of even a very small amount can adversely affect the precision of such highly sensitive quantitative analyses. Inertsil ODS-, featuring a neutral packing material surface, is also ideal for LC/MS (/MS) analyses of strong acids..e.e.e.e.e.e.e Intensity, cps.e.e.e.e.e.e.e.e.e.e.e.e.e. Time, min. Bromoacetic acid. Dibromoacetic acid. Tribromoacetic acid. Chloroacetic acid. Dichloroacetic acid. Trichloroacetic acid. Bromochloroacetic acid LC HPLC system Q TRAP Inertsil ODS- μm,. mm I.D. A CHOH B.% HCOOH A/B = / -. min- / -. min / - min- /. ml/min LC/MS/MS ESI, Negative, MRM Injection Vol. μl Australia & New Zealand contact info@winlab.com.au or call + ()

Comparison of inertness to Hinokitiol between Inertsil ODS- and commercially available ODS columns Hinokitiol having very strong chelating characteristics, is easily adsorbed with trace metal remaining on a packing material surface. SunFire C in the figure below tend to show a better peak shape every time a new injection is provided, since each new injection covers up more of the adsorption active sites. Inertsil ODS- provides very quantitative peaks from the st injection since it has completely removed metals from the surface of the packing material. st injection st injection st injection st injection nd injection nd injection nd injection nd injection Symmetry C SunFireTM C Atlantis T st injection GL- HPLC system μm,. mm I.D. A CHCN B.% HPO A/B = /, v/v. ml/min UV nm Injection Vol.. μl β-thujaplicin Hinokitiol. mg/ml O st injection nd injection st injection nd injection nd injection OH Luna C () ZORBAX Eclipse Plus C Hypersil GOLDTM Analysis of Tetracyclines by LC/MS/MS Tetracyclines are antibiotics broadly used as pharmaceuticals for animals, and the residues in livestock and sea product are a major issue today. High-sensitivity analysis by LC/MS (/MS) has received attention in these years. As tetracyclines have a very strong chelating characteristics, it has been anticipated that the adsorption on the column deteriorates quantitative precision. Inertsil ODS- is an ideal column for LC/MS (/MS) analyses of chelating compounds as well since it has completely removed metals from the surface of the packing material. LC HPLC system Q TRAP Inertsil ODS- μm,. mm I.D. A.% CHOH B.% HCOOH A/B = / -. min- / - min /. min- /. ml/min LC/MS/MS ESI, Positive, MRM Injection Vol. μl. Tetracycline TC μg/l. Oxytetracycline OTC μg/l. Chlortetracycline CTC μg/l. Doxycycline DC μg/l Australia & New Zealand contact info@winlab.com.au or call + ()

Comparison of analyses under % Aqueous s Under the condition of mobile phase containing very little organic solvent, mobile phase can easily come out from pores in the packing material, resulting in the dewetting phenomenon. As shown in the figures below, such water repellency makes the analysis results unstable over the retention time. Inertsil ODS-, with an ideal chemical processing, minimizes such dewetting phenomenon, achieving very trustable elution with % aqueous eluents. Introduce % water for minutes. Analysis (upper chromatograms) Stop flow for minutes. Introduce eluent for minutes. Stop flow for minutes. Introduce eluent for minutes. Analysis (lower chromatograms) Reduction rate of retention time.% Reduction rate of retention time.% Reduction rate of retention time.% Testing procedure Symmentry C SunFireTM C GL- HPLC system μm,. mm I.D. HO. ml/min UV nm. Cytosine. Uracil. Guanine. Thymine. Adenine Analytical Ordering Information Particle size μm μm Diameter (mm) Length (mm) The joint is Waters / type.. - - - - - - - - - - - -. - - - - - - - - - - - -... - - - - - - - - - - - -. - - - - - - - - - - - -. - - - - - - - - - - - -. - - - - - - - - - - - -.. For other column sizes, please contact us. Preparative Ordering Information Diameter (mm) Length (mm) Guard. - - - - The joint is Waters / type.. - -. - -. - - For other column sizes, please contact us. Cartridge Guard Ordering Information Diameter of the analytical column applicable (mm) Diameter of the guard column (mm) Length of the guard column (mm)..,....,...,.. Replacement cartridge guard columns (/pk) - - - - - - The only joint available is Waters / type. Please specify the packing material and the particle size in your order. We also have other guard column (GL-cart) as well. Please inquire for further details. Holder/Cartridge set ( holder and cartridges) - - - - - - Australia & New Zealand contact info@winlab.com.au or call + ()

Applications Food additives Nucleic acid bases GL- HPLC system Inertsil ODS- μm,. mm I.D. A CH CN B mm CH COONa ph., CH COOH A/B = / - min - / - min - / - min - /. ml/min. Sodium Saccharin UV nm. p-hydroxy benzoic acid Injection Vol. μl. Sorbic acid Food additives. Benzoic acid. p-hydorxy benzoic acid methyl ester. Dehydroacetic Acid. p-toluic acid. p-hydroxy benzoic acid ethyl ester. p-hydroxy benzoic acid n-propyl ester Injection Vol. GL- HPLC system Inertsil ODS- μm,. mm I.D..M KH PO,.M NaClO ph., H PO. ml/min. Cytosine UV nm. Uracil μl. Guanine Nucleobase. Adenine. Cytidine. Uridine. Thymine. Adenosine. Guanosine. Thymidine Efficient ingredients in a cold medicine GL- HPLC system Inertsil ODS- μm,. mm I.D. A CH CN. Maleic acid B.% H PO Derived chlorpheniramine maleate A/B = / - min - /. Acetaminophen. ml/min. Caffein. Chlorpheniramine UV nm Derived chlorpheniramine maleate Injection Vol. μl. Ethenzamide Anti-Cold medicine. Bromovalerylurea. Apronalide. Isopropylantipyrine. Ibuprofen Tricyclic antidepressant LC HPLC system API Inertsil ODS- μm,. mm I.D. A CH CN B mm CH COONH ph., CH COOH A/B = /, v/v. ml/min. Imipramine LC/MS/MS ESI, Positive, MRM. Clomipramine Injection Vol. μl. Amitriptyline Antidepressant agent. Mianserin Australia & New Zealand contact info@winlab.com.au or call + ()