DHL Analytical received 2 sample(s) on 6/18/2009 for the analyses presented in the following report.

Similar documents
ANALYTICAL REPORT. Job Number: Job Description: Old Douglas Harbor. For: PND Engineers, Inc West 36th Ave. Anchorage, AK 99503

ANALYTICAL REPORT. Job Number: Job Description: Old Douglas Harbor. For: PND Engineers, Inc West 36th Ave. Anchorage, AK 99503

If you have any questions concerning this report, please feel free to contact me. REPORT OF LABORATORY ANALYSIS

alscience nvironmental aboratories, Inc.

If you have any questions concerning this report, please feel free to contact me. REPORT OF LABORATORY ANALYSIS

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL REPORT. Job Number: Job Description: TO4-2012, RACER, GM Wilmington

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL REPORT. Attn: Richard Boelter

APPENDIX D Laboratory Analytical Reports

Enclosed is a copy of your laboratory report for test samples received by our laboratory on Thursday, February 25, 2010.

~ ALG ANALYTICAL LABORATORY GROUP

Maine DEP DRO. MY05TP220A(0-0.5) MY05TP222A(0-0.5) FD MY05TP223A(0-0.5) FD MY05TP220A (EB) EB-Equipment Rinsate Blank FD- Field Duplicate Samples

ACZ Laboratories, Inc Downhill Drive Steamboat Springs, CO (800)

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL REPORT. Attn: Richard Boelter

GLM & Associates. February 9, 2018

2017 Annual Groundwater Monitoring and Corrective Action Report. Prairie Creek Generating Station Cedar Rapids, Iowa. Alliant Energy.

ANALYTICAL REPORT. Job Number: Job Description: TO4-2012, RACER, GM Wilmington

Analytical Report

KSA Environmental Laboratory Inc.

ANALYTICAL REPORT. Job Number: Job Description: Transform Complete

2017 Annual Groundwater Monitoring and Corrective Action Report. Ottumwa Generating Station Ottumwa, Iowa. Alliant Energy. Prepared for: Prepared by:

2017 Annual Groundwater Monitoring and Corrective Action Report. Lansing Generating Station Lansing, Iowa. Alliant Energy. Prepared for: Prepared by:

American Environmental Testing Laboratory Inc.

Drake Petroleum Company, Inc. Accutest Job Number: JB Total number of pages in report:

BIO-CHEM Laboratories, Inc. Work Order Sample Summary. CLIENT: CTRA Project: 6454 T Lab Order: A 6454 Aqueous 3/1/2013.

Some analyses have been subcontracted outside of the Pace Network. The subcontracted laboratory report has been attached.

Certificate of Analysis FINAL REPORT

ANALYTICAL REPORT. Attn: Thomas W Hensel

KESTREL. April 26, Mr. Stephen Evans Maine Yankee 321 Old Ferry Road Wiscasset, Maine 04578


ALPHA ANALYTICAL LABORATORIES. Eight Walkup Drive Westborough, Massachusetts (508)

The following report includes the data for the above referenced project for sample(s) received on 5/15/2017 at Air Toxics Ltd.

Utilizing Data Trend Evaluations in Method Audits and Regulations Development

PROJECT ID: W09341 LABORATORY REPORT NUMBER: L

Laboratory 101: A Guide to Understanding your Testing Laboratory

Method 8270C PAH. FD- Field Duplicate Samples

November 23, Mr. Shawn Liddle District Clerk Albion Central School District 324 East Avenue Albion, NY 14411

ANALYTICAL REPORT. Job Number: Job Description: Gasoline Uptake Study. For: IRST Commonwealth Dr. Louisville, KY 40299

TETRA TECH, INC. December 8, Lynn Nakashima Berkeley Regional Office 700 Heinz Avenue, Suite 200C Berkeley, California 94710

ANALYTICAL RESULTS. Project: Mayflower, AR Pipeline Incident

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

ANALYTICAL RESULTS. Project: Mayflower, AR Pipeline Incident

LABORATORY REPORT. If you have any questions concerning this report, please do not hesitate to call us at (800) or (574)

ANALYTICAL RESULTS. Project: Mayflower, AR Pipeline Incident

LABORATORY DATA REVIEW CHECKLIST

The Phase I ESA Report provided the following recommendation regarding a diesel fuel UST connected to a backup electrical generator:

Application of Detection and Quantification Concepts to Chlorine Residual Measurements

EDD FIELD DESCRIPTIONS

Laboratory Analytical Data

Client Sample ID.: HB3

KSA Environmental Laboratory Inc.

LABORATORY REPORT #P (Air) SAMPLE DATE: AUGUST 7-9, 2017

LABORATORY REPORT. If you have any questions concerning this report, please do not hesitate to call us at (800) or (574)

ANALYTICAL REPORT. Sampling Parameter: Area 200 cm² Result. (ug/100cm²) RL (ug/sample) Sampling Parameter: Area 300 cm². Result

December 30, Laboratory Report This Page is to be Stamped Introduction: This report package contains total of 5 pages divided into 3 sections:

July 31, Dear Mr. Lurix:

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

CERTIFICATE OF ANALYSIS

Copyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction

Appendix B. Sediment Sampling Memo Winnetka Pond East

One Stop DIY Shop. PO Box 104 New Germany, MN Carbonyl Assay. Samples Received 09/09/2014. Analysis Report ( )

QA/QC in the Wastewater Laboratory. Steve Roberts Ohio EPA Division of Environmental Services 05/11/2016

January 19, Dear Mr. Nightingale:

ANALYTICAL REPORT. Results relate only to the items tested and the sample(s) as received by the laboratory. Page 1 of 5

ALLOWAY METHOD OUTLINE

Quick Nic Juice. 122 Indian Springs Drive #5 Sandwich, IL Carbonyl Assay Samples Received 3/16/2015. Analysis Report ( )

QAM-Q-101 Laboratory Quality Control

ACCURACY is the nearness of a result or the mean of a set of results to the true or accepted value.

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Innokin Technology Co., Ltd. Building 6, XinXinTian Industrial Park, Xinsha Road Shajing Baoan District, Shenzhen, China P.R.C.

Hydra-C Application Note: 1076


ANALYTICAL REPORT L White Water Inc. 253B Worcester Road Charlton, MA TOWN OF EASTHAM /19/17

Verification of LOD and LOQ according to the NELAC and TNI Standards

RIGHT SOLUTIONS RIGHT PARTNER

LAMBTON SCIENTIFIC (A Division of Technical Chemical Services Inc.)

How Well Do You Know Lab Reports? Making Sense Out of Seemingly Simple Lab Reports

Sample RM Analytical Report ( B) HPLC/UV Analysis Acetaldehyde, Acrolein, Crotonaldehyde, Formaldehyde

U.S. EPA SW-846 Method 6010C Using the Prodigy7 High- Dispersion ICP Introduction. Application Note - AN1305. Experimental

Appendix B RFI Sampling Program Summary (appears on CD only)

TCEQ Regulatory Guidance Remediation Division RG-366/TRRP-13 December 2002

Review and Reporting of Chemical of Concern (COC) Concentration Data Under the TRRP Rule (30 TAC 350)

ENVIRONMENTAL LABORATORY SECTOR VOLUME 1 MANAGEMENT AND TECHNICAL REQUIREMENTS FOR LABORATORIES PERFORMING ENVIRONMENTAL ANALYSIS

Introduction. The following definitions may help you better understand the components of the data report.

ANALYTICAL REPORT L White Water Inc. 253B Worcester Road Charlton, MA TOWN OF EASTHAM /07/18

How s that *new* LOD Coming? Rick Mealy WWOA Board of Directors DNR LabCert

PA-DEP 3686, Rev. 1. Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID)

SeCtiOn 5 [STOCK AND CUSTOM] Assurance. Multi-Element CLP Standards

This procedure describes the monitoring activities in a laboratory quality control (QC) program to ensure the quality of test results.

Sample RM061614VG. Analytical Report ( ) GC/FID Analysis (RM01 & RM02) Diethylene glycol Vegetable glycerin Purity

LOUISVILLE CHEMISTRY GUIDELINE (LCG)

Three Mile Creek Watershed Management Plan

Laboratory Report Number(s) Lone Tree Road (Deep) 10/5/15, 10/19/15, 6/13/16. Address Sample Date(s) Analyses Requested

Pittcon P

Z/zs. tnitiats: wu\ Z-z* I A. sop-c-102. Determination of Chemical Oxygen Demand. Revision 6. Approval: Effective date: 3. Renewat date: 7lt:,:

Total Petroleum and Saturated Hydrocarbons by Gas Chromatography/Flame Ionization Detector

* * * * * * * November 1, Pierce County Parks and Recreation Services Department 9112 Lakewood Drive SW Lakewood, WA 98499

Method 0060 or Method 29. Method for Determining Metals and Mercury Emissions in Stack Gas

Transcription:

June 26, 2009 Charles E. Martin 11370 Breininger Road Hicksvile, OH 43526 TEL: (419) 542-6645 FAX: (419) 542-6475 Order No: 0906168 RE: Dear Charles E. Martin: DHL Analytical received 2 sample(s) on 6/18/2009 for the analyses presented in the following report. There were no problems with the analyses and all data met requirements of NELAC except where noted in the Case Narrative. All non-nelac methods will be identified accordingly in the case narrative and all estimated uncertainties of test results are within method or EPA specifications. If you have any questions regarding these tests results, please feel free to call. Thank you for using DHL Analytical. Sincerely, John DuPont Lab Manager This report was performed under the accreditation of the State of Texas Laboratory Certification Number: T104704211-09-TX 2300 Double Creek Dr. Round Rock, TX 78664 Phone: (512) 388-8222 Fax: (512) 388-8229 http://www.dhlanalytical.com Page 1 of 14

Table of Contents Miscellaneous Documents... 3 Case Narrative... 6 Sample Summary... 7 Prep Dates Report... 8 TCLP Dates Report... 9 Analytical Dates Report... 10 Sample Results... 11 Analytical QC Summary Report... 13 Page 2 of 14

Page 3 of 14

Page 5 of 14

Lab Order: 0906168 CASE NARRATIVE The samples were analyzed using the method outlined in the following reference: Method SW1311/6020 - TCLP Metals LOG IN A total of 2 samples were received and logged-in on 6/18/2009. The samples arrived in good condition and were properly packaged. TCLP METALS ANALYSIS For TCLP Metals analysis, Copper was detected below the reporting limit for the TCLP Method Blank (MB-35621 TCLP). All associated samples showed Copper at greater than ten times the concentration detected in the TCPL MB. This analyte was not detected in the Method Blank for this batch (MB-35630). No further corrective actions were taken. All sample results were below TCLP or RCRA characterization limits. The samples are therefore nonhazardous for the parameters that were analyzed. Page 6 of 14

Lab Order: 0906168 Work Order Sample Summary Lab Smp ID Client Sample ID Tag Number Date Collected Date Recv'd 0906168-01 606212 06/15/09 01:00 PM 06/18/09 0906168-02 906092 06/15/09 01:00 PM 06/18/09 Page 7 of 14

Lab Order: 0906168 PREP DATES REPORT Sample ID Client Sample ID Collection Date Matrix Test Number Test Name Prep Date Batch ID 0906168-01A 606212 06/15/09 01:00 PM Solid SW3005A Aq Prep Metals : ICP-MS 06/24/09 09:00 AM 35630 606212 06/15/09 01:00 PM Solid SW3005A Aq Prep Metals : ICP-MS 06/24/09 09:00 AM 35630 0906168-02A 906092 06/15/09 01:00 PM Solid SW3005A Aq Prep Metals : ICP-MS 06/24/09 09:00 AM 35630 906092 06/15/09 01:00 PM Solid SW3005A Aq Prep Metals : ICP-MS 06/24/09 09:00 AM 35630 Page 8 of 14

Lab Order: 0906168 TCLP DATES REPORT Sample ID Client Sample ID Collection Date Matrix Test Number Test Name Prep Date Batch ID 0906168-01A 606212 06/15/09 01:00 PM Solid SW1311 TCLP Sample Prep (Metals) 06/23/09 04:30 PM 35621 0906168-02A 906092 06/15/09 01:00 PM Solid SW1311 TCLP Sample Prep (Metals) 06/23/09 04:30 PM 35621 Page 9 of 14

Lab Order: 0906168 ANALYTICAL DATES REPORT Sample ID Client Sample ID Matrix Test Number Test Name Batch ID Dilution Analysis Date Run ID 0906168-01A 606212 Solid SW1311/6020 TCLP Metals 35630 1 06/24/09 03:18 PM ICP-MS2_090624A 606212 Solid SW1311/6020 TCLP Metals 35630 50 06/24/09 04:40 PM ICP-MS2_090624A 0906168-02A 906092 Solid SW1311/6020 TCLP Metals 35630 1 06/24/09 03:23 PM ICP-MS2_090624A 906092 Solid SW1311/6020 TCLP Metals 35630 100 06/24/09 04:45 PM ICP-MS2_090624A Page 10 of 14

Client Sample ID: 606212 Lab ID: 0906168-01 Project No: Collection Date: 06/15/09 01:00 PM Lab Order: 0906168 Matrix: Solid Analyses Result MDL RL Qual Units DF Date Analyzed TCLP Metals SW1311/6020 Analyst: KW Copper 262 1.00 5.00 mg/l 50 06/24/09 04:40 PM Nickel 0.911 0.0300 0.100 mg/l 1 06/24/09 03:18 PM Qualifiers: * Value exceeds TCLP Maximum Concentration Level B Analyte detected in the associated Method Blank C Sample Result or QC discussed in the Case Narrative DF Dilution Factor E TPH pattern not Gas or Diesel Range Pattern J MDL N ND RL S Analyte detected between MDL and RL Method Detection Limit Parameter not NELAC certified Not Detected at the Method Detection Limit Reporting Limit Spike Recovery outside control limits Page 11 of 14

Client Sample ID: 906092 Lab ID: 0906168-02 Project No: Collection Date: 06/15/09 01:00 PM Lab Order: 0906168 Matrix: Solid Analyses Result MDL RL Qual Units DF Date Analyzed TCLP Metals SW1311/6020 Analyst: KW Copper 508 2.00 10.0 mg/l 100 06/24/09 04:45 PM Nickel 17.8 0.0300 0.100 mg/l 1 06/24/09 03:23 PM Qualifiers: * Value exceeds TCLP Maximum Concentration Level B Analyte detected in the associated Method Blank C Sample Result or QC discussed in the Case Narrative DF Dilution Factor E TPH pattern not Gas or Diesel Range Pattern J MDL N ND RL S Analyte detected between MDL and RL Method Detection Limit Parameter not NELAC certified Not Detected at the Method Detection Limit Reporting Limit Spike Recovery outside control limits Page 12 of 14

Work Order: 0906168 ANALYTICAL QC SUMMARY REPORT RunID: ICP-MS2_090624A Sample ID: MB-35630 Batch ID: 35630 TestNo: SW1311/6020 Units: mg/l SampType: MBLK Run ID: ICP-MS2_090624A Analysis Date: 06/24/09 02:51 PM Prep Date: 06/24/09 Copper ND 0.0100 Nickel ND 0.0100 Sample ID: MB-35621 TCLP Batch ID: 35630 TestNo: SW1311/6020 Units: mg/l SampType: MBLK Run ID: ICP-MS2_090624A Analysis Date: 06/24/09 02:56 PM Prep Date: 06/24/09 Copper 0.0347 0.100 Nickel ND 0.100 Sample ID: LCS-35630 Batch ID: 35630 TestNo: SW1311/6020 Units: mg/l SampType: LCS Run ID: ICP-MS2_090624A Analysis Date: 06/24/09 03:02 PM Prep Date: 06/24/09 Copper 0.196 0.0100 0.2000 0 97.8 80 120 Nickel 0.199 0.0100 0.2000 0 99.6 80 120 Sample ID: LCSD-35630 Batch ID: 35630 TestNo: SW1311/6020 Units: mg/l SampType: LCSD Run ID: ICP-MS2_090624A Analysis Date: 06/24/09 03:07 PM Prep Date: 06/24/09 Copper 0.196 0.0100 0.2000 0 98.2 80 120 0.357 15 Nickel 0.196 0.0100 0.2000 0 98.2 80 120 1.47 15 Sample ID: 0906201-01A SD Batch ID: 35630 TestNo: SW1311/6020 Units: mg/l SampType: SD Run ID: ICP-MS2_090624A Analysis Date: 06/24/09 04:18 PM Prep Date: 06/24/09 Copper 0 0.500 0 0.02442 0 10 Nickel 0 0.500 0 0 0 10 Sample ID: 0906201-01A PDS Batch ID: 35630 TestNo: SW1311/6020 Units: mg/l SampType: PDS Run ID: ICP-MS2_090624A Analysis Date: 06/24/09 04:24 PM Prep Date: 06/24/09 Copper 1.82 0.100 2.000 0.02442 89.8 75 125 Nickel 1.81 0.100 2.000 0 90.7 75 125 Sample ID: 0906201-01A MS Batch ID: 35630 TestNo: SW1311/6020 Units: mg/l SampType: MS Run ID: ICP-MS2_090624A Analysis Date: 06/24/09 04:29 PM Prep Date: 06/24/09 Copper 1.88 0.100 2.000 0.02442 92.6 80 120 Nickel 1.87 0.100 2.000 0 93.4 80 120 Sample ID: 0906201-01A MSD Batch ID: 35630 TestNo: SW1311/6020 Units: mg/l SampType: MSD Run ID: ICP-MS2_090624A Analysis Date: 06/24/09 04:34 PM Prep Date: 06/24/09 Copper 1.84 0.100 2.000 0.02442 90.8 80 120 1.99 15 Nickel 1.85 0.100 2.000 0 92.6 80 120 0.860 15 Qualifiers: B Analyte detected in the associated Method Blank DF Dilution Factor J Analyte detected between MDL and RL MDL Method Detection Limit ND Not Detected at the Method Detection Limit R RL S J N RPD outside accepted control limits Reporting Limit Spike Recovery outside control limits Analyte detected between SDL and RL Parameter not NELAC certified Page 13 of 14

Work Order: 0906168 ANALYTICAL QC SUMMARY REPORT RunID: ICP-MS2_090624A Sample ID: ICV1-090624 Batch ID: R43965 TestNo: SW1311/6020 Units: mg/l SampType: ICV Run ID: ICP-MS2_090624A Analysis Date: 06/24/09 02:23 PM Prep Date: Copper 0.102 0.0100 0.100 0 102 90 110 Nickel 0.101 0.0100 0.100 0 101 90 110 Sample ID: CCV1-090624 Batch ID: R43965 TestNo: SW1311/6020 Units: mg/l SampType: CCV Run ID: ICP-MS2_090624A Analysis Date: 06/24/09 03:51 PM Prep Date: Copper 0.211 0.0100 0.200 0 106 90 110 Nickel 0.200 0.0100 0.200 0 100 90 110 Sample ID: CCV2-090624 Batch ID: R43965 TestNo: SW1311/6020 Units: mg/l SampType: CCV Run ID: ICP-MS2_090624A Analysis Date: 06/24/09 04:50 PM Prep Date: Copper 0.197 0.0100 0.200 0 98.5 90 110 Nickel 0.198 0.0100 0.200 0 99.0 90 110 Qualifiers: B Analyte detected in the associated Method Blank DF Dilution Factor J Analyte detected between MDL and RL MDL Method Detection Limit ND Not Detected at the Method Detection Limit R RL S J N RPD outside accepted control limits Reporting Limit Spike Recovery outside control limits Analyte detected between SDL and RL Parameter not NELAC certified Page 14 of 14