COMPARATIVE STUDY ON DETERMINING THE INTERNAL FRICTION ANGLE FOR SAND

Similar documents
THE BEHAVIOUR OF ELASTOMERIC BEARINGS UNDER LOAD COMBINATIONS

MODEL FOR FLEXIBLE PLATES SUPPORTED ON PILES

ERRORS IN CONCRETE SHEAR WALL ELASTIC STRUCTURAL MODELING

THE OPERATIONAL FIABILITY IN THERMAL SYSTEMS THE WEIBULL DISTRIBUTION MODEL

THERMAL CONDUCTIVITY MEASUREMENT OF CONSTRUCTION MATERIALS USING THE THERMAL PROBE METHOD

INFLUENCES IN THERMAL CONDUCTIVITY EVALUATION USING THE THERMAL PROBE METHOD; SOME PRACTICAL ASPECTS

Prof. B V S Viswanadham, Department of Civil Engineering, IIT Bombay

STRESS AND STRAIN ANALYSIS IN CONTINUUM MECHANICS WITH APPLICABILITY IN SOIL MECHANICS

1.8 Unconfined Compression Test

EVALUATION OF A GENERAL PERFORMANCE INDEX FOR FLEXIBLE ROAD PAVEMENTS

The Stress Variations of Granular Samples in Direct Shear Tests using Discrete Element Method

COMPARATIVE ANALYSIS OF THE BENDING THEORIES FOR ISOTROPIC PLATES. CASE STUDY

8.1. What is meant by the shear strength of soils? Solution 8.1 Shear strength of a soil is its internal resistance to shearing stresses.

SHEAR STRENGTH OF SOIL

Cite this paper as follows:

FINITE ELEMENT ANALYSIS OF FRICTIONAL CONTACTS

Laboratory Testing Total & Effective Stress Analysis

Numerical Assessment of the Influence of End Conditions on. Constitutive Behavior of Geomaterials

A COMPARATIVE ANALYSIS OF WEB BUCKLING RESISTANCE: STEEL PLATE GIRDERS GIRDERS WITH CORRUGATED WEBS

MANLEY-ROWE TYPE RELATIONS CONCERNING THE ACTIVE PSEUDOPOWERS

3-D FINITE ELEMENT ANALYSIS OF A SINGLE-PHASE SINGLE-POLE AXIAL FLUX VARIABLE RELUCTANCE MOTOR

SHEAR STRENGTH OF SOIL UNCONFINED COMPRESSION TEST

(Refer Slide Time: 02:18)

Ch 4a Stress, Strain and Shearing

Soil strength. the strength depends on the applied stress. water pressures are required

STRESS DROP AS A RESULT OF SPLITTING, BRITTLE AND TRANSITIONAL FAULTING OF ROCK SAMPLES IN UNIAXIAL AND TRIAXIAL COMPRESSION TESTS

CORRELATIONS BETWEEN GEOTECHNICAL PARAMETERS OF TRANSILVANIAN COHESIONLESS SOILS BASED ON TRIAXIAL LABORATORY TESTS RESULTS

Pullout Tests of Geogrids Embedded in Non-cohesive Soil

Theory of Shear Strength

Chapter 5 Shear Strength of Soil

Shear Strength of Soils

THE EXPERIMENTAL TESTING AND NUMERICAL MODEL CALIBRATION OF A STEEL STRUCTURE

HEAT TRANSFER STUDY IN A COAXIAL HEAT EXCHANGER USING NANOFLUIDS

THE SHEAR BEHAVIOR OBTAINED FROM THE DIRECT SHEAR AND PULLOUT TESTS FOR DIFFERENT POOR GRADED SOIL-GEOSYNTHETIC SYSTEMS

BACKFILL AND INTERFACE CHARACTERISTICS

D1. A normally consolidated clay has the following void ratio e versus effective stress σ relationship obtained in an oedometer test.

Brittle Deformation. Earth Structure (2 nd Edition), 2004 W.W. Norton & Co, New York Slide show by Ben van der Pluijm

Chapter (12) Instructor : Dr. Jehad Hamad

Appendix A Results of Triaxial and Consolidation Tests

GEOTECHNICAL PARAMETERS OBTAINED WITH NONLINEAR COMPUTATIONAL MODELS USED IN GEOTECHNICAL ENGINEERING PROBLEMS

PERFORMANCE OF BITUMINOUS COATS IN REDUCING NEGATIVE SKIN

Theory of Shear Strength

Pre-failure Deformability of Geomaterials. Hsin-yu Shan Dept. of Civil Engineering National Chiao Tung University

Triaxial Shear Test. o The most reliable method now available for determination of shear strength parameters.

True Triaxial Tests and Strength Characteristics Study on Silty Sand Liang MA and Ping HU

Experimental Study on the Rate Effect on the Shear Strength

Stress and Strains in Soil and Rock. Hsin-yu Shan Dept. of Civil Engineering National Chiao Tung University

GEO E1050 Finite Element Method Mohr-Coulomb and other constitutive models. Wojciech Sołowski

EFFECT OF PARTICLE SHAPE ON SAND-GEOSYNTHETIC INTERFACES

SOME OBSERVATIONS RELATED TO LIQUEFACTION SUSCEPTIBILITY OF SILTY SOILS

Reciprocal of the initial shear stiffness of the interface K si under initial loading; reciprocal of the initial tangent modulus E i of the soil

1.5 STRESS-PATH METHOD OF SETTLEMENT CALCULATION 1.5 STRESS-PATH METHOD OF SETTLEMENT CALCULATION

Module 4 Lecture 20 Pore water pressure and shear strength - 4 Topics

Landslide FE Stability Analysis

DYNAMIC ANALYSIS AND THE SOIL IMPACT ON THE PILED RAFT FOUNDATION OF A TALL OFFICE BUILDING (II)

SHEAR STRENGTH OF SOIL

Experimental Validation of Particle-Based Discrete Element Methods

Cyclic Behavior of Sand and Cyclic Triaxial Tests. Hsin-yu Shan Dept. of Civil Engineering National Chiao Tung University

Evaluation of dynamic behavior of culverts and embankments through centrifuge model tests and a numerical analysis

SHEAR STRENGTH I YULVI ZAIKA

LIQUEFACTION STRENGTH OF COARSE WELL GRADED FILL UNDER TORSIONAL SIMPLE SHEAR

Drained Against Undrained Behaviour of Sand

Chapter 5 CENTRIC TENSION OR COMPRESSION ( AXIAL LOADING )

3.22 Mechanical Properties of Materials Spring 2008

SURFACE RESISTIVITY MEASUREMENTS OF ELECTROSTATIC DISCHARGE PROTECTIVE MATERIALS FOR DIFFERENT RELATIVE HUMIDITY LEVELS

Strength of Material. Shear Strain. Dr. Attaullah Shah

PLANES OF WEAKNESS IN ROCKS, ROCK FRCTURES AND FRACTURED ROCK. Contents

Effect of Moisture on Shear Strength Characteristics of Geosynthetic Reinforcement Subgrade

Distinct simulation of earth pressure against a rigid retaining wall considering inter-particle rolling resistance in sandy backfill

2D AND 3D PROCESSING OF THE INTERDEPENDENCE BETWEEN THE COMFORT MAIN INDICATORS

Ch 5 Strength and Stiffness of Sands

Shear strength. Common cases of shearing In practice, the state of stress in the ground will be complex. Common cases of shearing Strength

A PARTICULAR FORECASTING CASE FOR THE MONTHLY FLOW RATES OF THE PRUT RIVER

Numerical Modeling of Direct Shear Tests on Sandy Clay

ANALYSIS OF THE THERMO-CONVECTION VARIATION IN TUBULAR HEAT EXCHANGERS FUNCTIONING WITH NANOFLUID

Shear Strength of Soil

Reinforced Soil Structures Reinforced Soil Walls. Prof K. Rajagopal Department of Civil Engineering IIT Madras, Chennai

Module 5: Theories of Failure

BIODEGRADABLE POLYMERS AND THEIR INFLUENCE ON ADHERENCE BETWEEN TEXTILE PRODUCTS AND WOOD

walls, it was attempted to reduce the friction, while the friction angle mobilized at the interface in the vertical direction was about degrees under

Following are the results of four drained direct shear tests on an overconsolidated clay: Diameter of specimen 50 mm Height of specimen 25 mm

CHARACTERISTICS OF LIQUEFIED SILTY SANDS FROM MEIZOSEISMAL REGION OF SHILLONG PLATEAU, ASSAM AND BHUJ IN INDIA

Welcome back. So, in the last lecture we were seeing or we were discussing about the CU test. (Refer Slide Time: 00:22)

FINDING THE TRACES OF A GIVEN PLANE: ANALYTICALLY AND THROUGH GRAPHICAL CONSTRUCTIONS

Soil Geosynthetic Interaction: Design Parameters from Experimental and Theoretical Analysis

Prediction of torsion shear tests based on results from triaxial compression tests

Experiment Two (2) Torsional testing of Circular Shafts

Physical and mechanical properties of decomposed granite soils sampled in Cheongju, Korea

LATERAL EARTH PRESSURE

UNDRAINED FLOW CHARACTERISTICS OF PARTIALLY SATURATED SANDY SOILS IN TRIAXIAL TESTS

Lateral Earth Pressure

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 1, No 4, 2011

Soil Mechanics Prof. B.V.S. Viswanathan Department of Civil Engineering Indian Institute of Technology, Bombay Lecture 51 Earth Pressure Theories II

file:///d /suhasini/suha/office/html2pdf/ _editable/slides/module%202/lecture%206/6.1/1.html[3/9/2012 4:09:25 PM]

Study of Pile Interval of Landslide Restraint Piles by Centrifuge Test and FEM Analysis

Module 12:Insitu Ground Reinforcement and liquefaction of soils Lecture 38:Definition and mechanism of Liquefaction. The Lecture Contains:

Evaluation of Fault Foundation Interaction, Using Numerical Studies

SHEAR STRENGTH OF SOIL. Chapter 10: Sections Chapter 12: All sections except

NORMAL STRESS. The simplest form of stress is normal stress/direct stress, which is the stress perpendicular to the surface on which it acts.

STUDY OF PERFORMANCE OF GEOGRID AND SOIL INTERFACE USING VERTICAL PULLOUT TEST. Uttarakhand,

Transcription:

BULETINUL INSTITUTULUI POLITEHNIC DIN IAŞI Publicat de Universitatea Tehnică Gheorghe Asachi din Iaşi Tomul LX (LXIV), Fasc. 2, 214 Secţia CONSTRUCŢII. ARHITECTURĂ COMPARATIVE STUDY ON DETERMINING THE INTERNAL FRICTION ANGLE FOR SAND BY ŞTEFAN CIOARĂ *, ANGHEL STANCIU and IRINA LUNGU Received: April 29, 214 Accepted for publication: May 19, 214 Gheorghe Asachi Technical University of Iaşi Faculty of Civil Engineering and Building Services Abstract. Shear strength is the main mechanical property which governs the stability and resistance of soil massifs. Practically in most cases failure occurs by concentration of plastic deformations in the form of shear bands along which the movement of a part of the massive develops as a result of exceeding the shear strength. It can be concluded that other failure modes are not possible if one take into account the fact that soil does not have tensile strength and that at hydrostatic compression the stresses transmitted to the soil massive are too small to cause particle crushing. It is also known that the shear strength parameters for soils will vary depending on state of stress and strain. It follows therefore that for each case the specific failure mechanism must be considered and the laboratory tests capable of reproducing these conditions should be selected. These are the reasons for conducting a comparative study regarding the results obtained by three types of tests, namely direct shear, triaxial compression in axial symmetric state of stress and biaxial compression. Key words: shear strength; plane strain; direct shear; triaxial. 1. Introduction The purpose of laboratory tests is to study the physico-mechanical behavior of soils under stress conditions similar to those in the field and provide * Corresponding author: e-mail: cioarastefan@gmail.com

2 Ştefan Cioară, Anghel Stanciu and Irina Lungu the data necessary to implement this behavior in a set of constitutive equations. In this respect it is assumed that the tested soil sample is a point in a soil massive, assumption valid only if the state of stress in the sample is uniform. Also for the study of mechanical properties of soil the hypothesis of isotropy and homogeneity are admitted, but for this case, more than for other construction materials, this is not true. Hence the need to study the soils considering different states of stresses so that the above-mentioned assumptions are better met. Consequently, in the common practice several types of tests to determine the shear strength are used. For the direct shear tests the principal stresses values can not be imposed and are practically unknown. Moreover the states of stress and strain which develop in the body of samples during the tests are irregular. Therefore the failure of soil samples occurs gradually and does not respect the principal stress directions (Saada & Townsend, 1981). Some of the problems above mentioned are solved by triaxial compression apparatus. In this case, the principal stresses can be imposed and consequently, a wide range of stress paths can be achieved. However, they are limited to axisymmetric stress state, which does not correspond to situations in the field. Also through numerical calculations it is shown that this type of test is predisposed to induce plastic failures of samples (Peters et al., 1988). From all the above mentioned facts is concluded that in common practice the tests are representative only for specific stress situations. Thus new test devices are needed in order to improve the knowledge regarding the behavior of soils under load throughout the principal stress space. Consequently, within the Faculty of Civil Engineering of Iaşi, an apparatus for testing the soils under biaxial compression was made. It was originally used to determine the mechanical characteristics of reinforced soils samples (Stanciu, 1981). 2. Original Plane Strain Apparatus The testing apparatus (Fig. 1) consists mainly in the biaxial cell and vertical and longitudinal loading systems. The biaxial cell (Fig. 2) consists of a metallic base plate (1) located at the bottom. On top of this two side plates made of 2 mm thick plexiglas (2) and the pressure cells (3) are placed. The plexiglas plate position is ensured by their indertion in special grooves laid down in the base plate and by means of profile angles (16). The pressure cells are jacked on the edges of the plexiglass plates using screw presses (13). At the top of the biaxial cell a steel plate is disposed (8) and fitted with three orifices with passage pieces (9) which are intended to allow the vertical sliding of the load piston (1). The unit of the cell

Bul. Inst. Polit. Iaşi, t. LX (LXIV), f. 2, 214 21 thus formed is secured vertically through four tie rods (15) which by clamping press the base plate and the top plate on the edges of the plexiglass plates. In the longitudinal direction the cell position is ensured by means of pressure through the metal frame (14), and the screw presses (13). Fig.1 Original plane strain apparatus (Stanciu, 1981). Fig. 2 Original plane strain apparatus biaxial cell details. The apparatus developed within the Faculty of Civil Engineering of Iaşi, allows testing of soil samples with dimensions of 2 1 4 mm (Fig. 3).

22 Ştefan Cioară, Anghel Stanciu and Irina Lungu Friction occurring at the interfaces between the soil samples and the elements of the biaxial cell (plexiglas side walls, the base plate and the cell piston) were reduced by lubricating all surfaces. Fig. 3 Sample sizes and stresses imposed in plane strain state (Cioară, 212). 3. Characteristics of Sand Used for Testing For conducting the tests below described a sand whose characteristics have been previously determined by laboratory tests was used. The grading curve of this sand is shown in Fig. 4. According to the value of the nonuniformity coefficient (U n ) the sand used for the tests is very uniform. 1 9 8 7 6 5 4 3 2 1 U n = 1.9351 C c = 1.1864.1.1.1 1 1 1 CLAY SILT SAND GRAVEL Fig. 4 The grading curve of sand used for the laboratory tests. The soil samples used for all the test types, have been made by compaction of successive layers using a piston. This procedure ensures the

Bul. Inst. Polit. Iaşi, t. LX (LXIV), f. 2, 214 23 maximum compaction state for this sand used. Also, using the same method in making of samples the same textures were obtained for the sand samples (Wanatowski & Chu, 28). 4. Determinations by Direct Shear Tests In order to determine the angle of internal friction through the direct shear tests, four samples were made applying normal stresses between 2 kpa and 8 kpa. Shear rate for all the test samples was 1 mm/min. In Fig. 5 a the stress strain relationship is given. It can be seen that the obtained graphs are similar for the four samples. Thus all the plotted curves show an increasing initial zone indicating that the shear strength of sand is mobilized. Then it follows the maximum point and strain softening region. At the end of the test the sand reaches the critical state and the angle of internal friction is practically constant. Based on the obtained results (Fig. 5 b) it can be noticed that the peaks in terms of internal friction angle are in the range of 35 while for the critical state they are around 27 3 (Table 1). Also, with increasing of normal stress on the shear plane, the segments that represents the mobilization of the shear strength extend while the curves maintain virtually the same shape. Consequently the horizontal displacement that correspond to themaximum values of the internal friction angle also increases. τ(kpa) 6 55 5 45 4 35 3 25 2 15 1 5 8 kpa 6 kpa 4 kpa 2 kpa 1 2 3 4 5 6 7 8 9 1 11 12 13 Δ(mm) φ-mobilized 4 35 3 25 2 8 kpa 15 6 kpa 1 4 kpa 5 2 kpa 1 2 3 4 5 6 7 8 9 1 11 12 13 Δ(mm) a b Fig. 5 Relevant graphs obtained by direct shear testing: a tressdisplacement curves; b internal friction angle mobilization curves. Table 1 Experimental Data Obtained by Direct Shear Tests σ 2 kpa 4 kpa 6 kpa 8 kpa φ max 37.36 33.886 35.617 34.137 φ rez 29.49 26.81 28.265 28.722

24 Ştefan Cioară, Anghel Stanciu and Irina Lungu 5. Determinations by Triaxial Tests For determining the angle of internal friction using the triaxial apparatus, 8 tests have been carried out during which the values for the confinement pressure were imposed between 1 kpa and 8 kpa. σ 1 (kpa) 3 25 2 15 1 5 TA-8 kpa TA-7kPa TA-6 kpa TA-5kPa TA-4kPa TA-3kPa TA-2kPa TA-1kPa Rf=σ 1 /σ 3 4.5 4. 3.5 3. 2.5 2. 1.5 1..5 TA-8 kpa TA-7 kpa TA-6 kpa TA-5 kpa TA-4 kpa TA-3 kpa TA-2 kpa TA-1 kpa 5 1 15 2 25 ε 1 (%). 5 1 15 2 25 ε 1 (%) a b Fig. 6 Stress strain curves obtained from triaxial compression test: a stress strain curves; b normalized stress strain curves. 4 35 3 φ mobilized( ) 25 2 15 1 TA-8kPA TA-7kPa TA-6kPa TA-5kPa TA-4kPa TA-3kPa TA-2kPa TA-1kPa 12 8 φ=33.1º 5 4 5 1 15 2 25 ε 1 (%) 4 8 12 16 2 24 28 a b Fig. 7 Value of the internal friction angle resulting from compression triaxial tests: a curves of mobilization; b limit circles and the intrinsic line.

Bul. Inst. Polit. Iaşi, t. LX (LXIV), f. 2, 214 25 During the tests two types of failures were observed. Most of the samples yielded without formation of shear bands and without an obvious peak value in terms of the vertical force. Only the samples TA7 and TA8 yielded with formation of a shear plane. Analysing the Fig. 6 a it can be observed that for these samples, the second zone of the graph begins to present a curved shape. Unlike the case of direct shear testing, for the triaxial tests the strain softening phenomenon does not occur. Therefore the residual values for the internal friction angles can not be estimated. Regarding the principal stress ratios, R f (Fig. 6 b), one can say that on average they are in the range of 3 5. The graphs drawn to represent the mobilizations of the internal friction angle show that the peaks are located around 33 (Fig. 7 a). 6. Determinations by Plane Strain Tests For this comparative study a total of three tests in plane strain state was carried out. They were differentiated by the value of the longitudinal pressure imposed during the test. For the first sample, a pressure of 5 kpa was set, 8 kpa for the second, while for the third sample the longitudinal pressure value was 11kPa. The tests began by imposing the values for the confinement pressure within the cells of the biaxial device. This pressure is then maintained constant throughout the testing period. After 3 min. the vertical load was applied. In Figs. 8,...,1 the failure modes for the tested samples are shown. It can be seen that for all samples, the failures are accompanied by the formation of shear planes that develop throughout the entire mass of sand. Regarding the inclination of the shear plans, the measurements made show that the angle is constant and around 6. The results presented here are consistent with those obtained by Desrues (Desrues & Hammand, 1989). As a result of similar tests it was found that on the boundaries of the samples the failure plans are reflected at the same angle. After performing the tests it can be noticed that the tested samples yielded by the same mechanism. Following the occurrence of the shear plans, compaction wedges formed through the samples. With the test advancement these wedges do not show significant changes in terms of deformations. The deformations of the sample are in large part due to slidings that occur along the shear plans. Therefore, under the constant action of the vertical load piston, the lateral wedges slide on the sides of the central wedge resulting in a tendency to expel in the longitudinal direction.

26 Ştefan Cioară, Anghel Stanciu and Irina Lungu Based on the compressive forces recorded during the tests the vertical stresses were calculated. Their evolution is represented in Fig. 11 a. It shall be noted that the vertical stress calculation did not take into account the change of the sample section. This issue affects the accuracy of the obtained results, Fig. 8 Failure of the first sample subjected to biaxial compression (σ L = 5 kpa). Fig. 9 Failure of the second sample subjected to biaxial compression (σ L = 8 kpa). Fig. 1 Failure of the third sample subjected to biaxial compression (σ L = 11 kpa). especially after the occurrence of the maximum compressive force. From this stage the section the samples change considerably due to expulsion of the lateral wedges. However, up to this point it can be considered that the sample is not

Bul. Inst. Polit. Iaşi, t. LX (LXIV), f. 2, 214 27 significantly deformed, and therefore the correction of the cross-section for the sample is not needed. Vertical stress σ V (kpa) Tensiune verticală (kpa) 9 8 7 6 5 4 3 2 5 kpa 8 kpa 11 kpa R R f =σ f =σ V /σ 1 /σ L 3 1 9 8 7 6 5 4 3 2 5 kpa 8 kpa 11 kpa 1 1 2 4 6 8 1 2 4 6 8 1 Deforma ie verticală ε 1 (%) Deforma ie verticală ε 1 (%) Vertical strain ε V (kpa) Vertical strain ε V (kpa) a b Fig. 11 Stress strain curves obtained from biaxial compression tests. 6 5 φ-mobilzed(º) φ mobilizat ( ) 4 3 2 5 kpa 1 8 kpa 11 kpa 2 4 6 8 1 Deforma ie verticală ε 1 (%) Vertical strain ε V (%) 6 4 2 φ=5.14 2 4 6 8 a b Fig. 12 Internal friction angle values resulting from biaxial tests: a curves of mobilization; b limit circles and the intrinsic line. It can be noticed from Fig. 11 that the three curves have different shapes, particularly in the case of the curve obtained for the sample 1 (σ L =

28 Ştefan Cioară, Anghel Stanciu and Irina Lungu = 5 kpa). Regarding the evolution of principal stress ratio, R f, shown in Fig. 11 b note that sample 1 (σ L = 5 kpa) has a large deviation relative to samples 2 (σ L = 8 kpa) and 3 (σ L = 11 kpa). A possible cause for this anomalies may be the poor lubrication of the surfaces of the cell. Analysing the data presented in Fig. 12 a and the Table 2 it was observed that with increasing confinement pressure (σ L ), the maximum force (F max ) and maximum vertical tension (σ V ) are reached at higher values of the vertical strain (ε v ). As in the case of triaxial tests, it is found that sand has no strain softening zone after reaching the maximum force, even though this failure has occurred with the development of the shear planes. Tabel 2 Experimental Data Obtained by Biaxial Compression Tests σ L, [kpa] F max, [dan] ε v, [%] σ V, [kpa] R f = σ 1 /σ 3 φ mobilized, [ ] 5 1,836.693 6.45 459.1733 9.183466 53.475 8 2,392.284 6.75 598.79 7.475988 49.821 11 3,26.348 6.9 81.587 7.287155 49.346 The mobilization curves were obtained by the same reasoning used in the case of triaxial tests with axially symmetric stress state using the following formula: V L arcsin, V L where : σ V is the vertical stress and σ L longitudinal sress. By applying this formula is implicitly admited that the vertical and longitudinal stresses are principal stresses and their directions are not affected by friction. Furthermore, it is accepted that σ V is the principal maximum stress and σ L is principal minimum stress. This assumption is not valid in the beginning of the test, during which the principal maximum stress occurs in the longitudinal direction of the sample. After the test operation is started by displacement of the vertical loading piston, the principal stresses rotate, until the principal maximum stress is set by the vertical direction and the principal minimum stress acts in the longitudinal direction. Therefore the formula is valid only after the establishing of the principal maximum stress on vertical direction. 7. Conclusion Based on the determinations by the three types of tests one can notice that the obtained results do not match in terms of the internal friction angle or mobilization curves.

Bul. Inst. Polit. Iaşi, t. LX (LXIV), f. 2, 214 29 While the direct shear and triaxial compression tests, produce results of the internal friction angle wich are very close, for the tests carried out in the biaxial compression apparatus the obtained values are wider appart from each other. This difference can be attributed to the influence of intermediate stress σ 2. One must not neglect the contribution of the friction occurring between soil sample and the components of the biaxial cell. Regarding the failure mode of the specimens subjected to compression tests, one notices that for triaxial compression tests, the yeldings are mainly plastic, without the occurrence of a shear plane. At the same time all samples yielded by showing several shear planes for the tests performed in the biaxial compression apparatus. Although the yieldings are different, none of the compression test shows evidence of the strain softening phenomenon. The cause of this situation can be better understood if one analyses the failure mechanism for dense sand. During the first stage of shearing the interparticle sliding is practically nonexistent due to the clenching between the sand particles. Once this phase is surpassed through dilatancy, slip occurs between particles. As the movements continue, the particles tend to align with one side or the other of the formed shear plane. This is the time when the residual friction angle is recorded. The lack of strain softening phenomenon in compression tests can be attributed to insufficient displacements generated on the shear plans. From this point of view, the direct shear tests have the advantage of ensuring the formation of a shear plane. Also the obtained information characterizes directly the shear plane and not the stress state within sample. REFERENCES Cioară Ş., Aparate de compresiune biaxială pentru determinarea rezistenţei la forfecare a pământurilor. Creaţii Universitare Tendinţe actuale în inginerie civilă şi instalaţii în construcţii, Iaşi, 212. Desrues J., Hammand W., Shear Banding Dependency on Mean Stress Level in Sand. Proc. of the 2nd Internat. Workshop on Numer. Meth. for Localization a. Bifurcation of Granular Bodies, 1989. Peters J.F., Lade P.V., Bro A., Shear Band Formation in Triaxial and Plane Strain Tests. Adv. Triaxial Testing of Soil and Rock, ASTM STP 977, 64-627, 1988. Saada A.S., Townsend F.C., State of the Art: Laboratory Strength Testing of Soils. ASTM-Laboratory Shear Strength of Soils, 1981. Stanciu A., Contribuţii la dimensionarea lucrărilor din pământ armat. Ph. D. Diss., Gheorghe Asachi Techn. Univ., Iaşi, 1981. Wanatowski D., Chu J., Effect of Specimen Preparation Method on the Stress Strain Behavior of Sand in Plane-Strain Compression Tests. Geotechn. Test. J., 31, 4 (28).

3 Ştefan Cioară, Anghel Stanciu and Irina Lungu STUDIU COMPARATIV ASUPRA DETERMINĂRII UNGHIULUI DE FRECARE PENTRU NISIP (Rezumat) Rezistenţa la forfecare este principala proprietate mecanică care guvernează stabilitatea şi rezistenţa masivelor de pământ. Astfel, în majoritatea cazurilor, cedarea survine prin concentrarea deformaţiilor sub forma unor planuri în lungul cărora se produce deplasarea unei părţi a masivului ca urmare a depăşirii rezistenţei la forfecare. ţinând cont de faptul că pământul nu posedă practic rezistenţă la întindere, iar la compresiune hidrostatică eforturile care se transmit masivelor de pământ sunt prea mici pentru a provoca strivirea particulelor materiale, se poate concluziona că alte moduri de cedare nu sunt posibile. Totodată este cunoscut faptul că parametrii rezistenţei la forfecare pentru pământuri variază în funcţie de starea de tensiuni şi deformaţii. Rezultă deci că în fiecare caz în parte trebuie considerat mecanismul specific de cedare şi alese încercările de laborator capabile să reproducă aceste condiţii. Acestea sunt motivele pentru care s-a realizat un studiu comparativ asupra rezultatelor obţinute prin trei tipuri de încercări, şi anume, forfecare directă, compresiune triaxială cu stare axial simetrică de tensiuni şi compresiune biaxială.