Strength in Technology

Similar documents
3µm Fortis C18. Fortis 2.1µm. Increased Efficiency. Scalability and Sensitivity

1.7µm Fortis UHPLC Columns

1.7 m Fortis UHPLC Columns

1.7µm Fortis C18 UHPLC Columns

Applications. Column Reproducibility. Casein Tryptic Digest. QC Test. Antimalarial. Antipsychotic. Column Reproducibility 7

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

penta-hilic UHPLC COLUMNS

8. Methods in Developing Mobile Phase Condition for C18 Column

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

Reversed Phase Solvents

penta-hilic UHPLC COLUMNS

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

LC and LC/MS Column Selection Flow Chart

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

Fluophase and Fluofix Columns

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

Small Molecule Selectivity Sampler

Part 2. Overview of HPLC Media

UPLC Method Development and Validation

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

Alltech Alltima HP Introduction

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

How proteins separate on reverse-phase HPLC

Acclaim Mixed-Mode WCX-1

Strength in Technology. Fortis Phase Chemistry Guide

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

Method Development Kits

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Fast Separation of Vastly Different Compounds by Isocratic HPLC

ultimate efficiency unleashed [ Cortecs 1.6 µm columns ]

for Acclaim Mixed-Mode WCX-1

Technical Guide Thermo Scientific Syncronis HPLC Columns

Analyze Nucleotides, Nucleosides, Purine, and Pyrimidine Bases Simultaneously with the Ultra IBD Column

for Acclaim Mixed-Mode HILIC-1 Column

ACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE Ultra Inert Base Deactivated HPLC Columns

Optimisil HPLC & UPLC Column catalogue

Inertsil Technical Library

Analysis - HPLC A.136. Primesep 5 µm columns B.136

RP C18 column with feature of a silanol group

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Advanced HPLC Method Development Using Quality by Design

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

LC Technical Information

ProntoSIL HPLC Columns

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Too Polar for Reversed Phase What Do You Do?

It s hot! ZIC -chilic

Next Generation of Phenyl Columns. Chromatography Products.

AQUASIL C18 Columns. AQUASIL 18 Columns TG Compatible with 100% aqueous mobile phase

The column name corresponds to ph value of the mobile phase where acid residue on the column switches from ionize form to neutral one.

Epic Aromatic Selectivity

Silanol. Groups Liquid Chromatography

BETASIL Columns TG Å high purity silica

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

Your Reversed Phase Method

CLIPEUS - A Small Shield for a Big Job

Definitive EtG/EtS LC-MS/MS Analysis:

Sepax SRT -C, Zenix -C SEC Phases

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Hypersil BDS Columns TG 01-05

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

mau 200 ph min

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

HyPURITY HPLC Columns Technical Guide. The PURE Choice for Method Development

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Reversed Phase Chromatography: Mobile phase Considerations

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

New Product Update. HPLC Columns

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Effects of Aqueous Sample Content and Aqueous Co-Solvent Composition on UPC 2 Separation Performance

Acclaim Mixed-Mode WAX-1 Columns

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS

A Look at Agilent HPLC Columns Choices

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC

Investigation of retention mechanisms in HILIC chromatography: Important considerations for robust method development

surpass all possibilities [ Cortecs 2.7 µm columns ]

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Comparison of different aqueous mobile phase HPLC techniques

William E. Barber, Ph.D. Applications Chemist October

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

HPLC method development using alternative selectivities

Inertsil ODS-EP Technical Information

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs)

Transcription:

Strength in Technology

Fortis C8 Excellent Peak Shapes Superb Quantitation ph Range - Fully Scalable 3,5,0μ C8 7% Fortis C8 is designed to provide characteristics which will aid in increased productivity to the analyst. Whether carrying out simple compound screens or complex metabolite i.d. Fortis C8 will provide the best in qualitative and quantitative data. L Optimised Peak Shape Whatever the compound functionality Fortis C8 is optimised in order to provide the best possible peak shapes. Basic, Acidic and Neutral analyte performance is first class across the ph spectrum. Higher Efficiencies Greater Reproducibility Resolution enhanced F8-050503 Fortis C8 00x4.6mm 3μ Mobile Phase: A - H 2 O + 0.% Formic acid B - ACN + 0.% Formic acid Gradient: 25-40% in 0min Temp: 20 C. Protriptyline 2. Nortriptyline 3. Amitriptyline 4. Trimipramine 254nm Optimised Resolution Only by optimising all factors of stationary phase design can the analyst be assured of the best possible chromatography. Fortis C8 s unique bonded character ensures that not only is reproducibility and robustness assured, but also that resolution is of the highest level. F8-050505 Fortis C8 00x4.6mm 5μ Mobile Phase: A - H 2 O + 0.% Formic acid B - ACN + 0.% Formic acid Gradient: 0-50% in 0min Temp: 20 C 254nm. Paracetamol 2. Caffeine 3. Excipient www.fortis-technologies.com Tel: +44 5 336 2266

Fortis H2o Retention of Polars Enhanced Resolution 00% Aqueous Compatible Fully Scalable 3,5,0μ Polar Endcapping 8% Fortis H2o is designed to aid in the separation and retention of polar analytes. Complex mobile phase systems can be bypassed if sufficient retention can be afforded solely from the stationary phase chemistry. Fortis H2o is designed to supply additional interaction with polar molecules which allows their successful retention. L Retention of Polar analytes Fortis H2o is optimised not only to help retain and resolve polar analytes, but also to be complimentary in resolution to Fortis C8. Hydrophilic as well as Hydrophobic interaction s Alternative Selectivity No MS bleed Column : Fortis H2o 50x4.6mm 5μ p/n : FHO-050705 Mobile Phase: H 2 O + 0.% Formic acid Flow : 0.8ml/min Temp : 20 C 270nm. Dopamine 2. Serotonin 3. DOPAC 4. 5-HIAA Alternative Selectivity Only by optimising all factors of stationary phase design can the analyst be assured of the best possible chromatography. Fortis H2o s unique bonded character ensures that not only is reproducibility and robustness assured, but also that resolution is of the highest level. Fortis H2o 00x4.6mm 5μ FHO-050505 Mobile Phase: A - H 2 O + 0.% Formic acid B - ACN + 0.% Formic acid Gradient: 5-70% in 0min Temp: 20 C 254nm. Chloramphenicol www.fortis-technologies.com Tel: +44 5 336 2266

Fortis Phenyl Unique Selectivity Aromatic Retention and Selectivity Enhanced Polar Retention Excellent Peak shapes 3,5,0μ Diphenyl 3% Fortis Phenyl is designed to provide characteristics which will enhance selectivity. Providing the analyst extra retention of compounds containing aromatic functionality. Extra selectivity and retention can be found for polar substrates, along with metabolite profiling. L Enhanced Selectivity Selectivity of compounds normally difficult to resolve on a hydrophobic alkyl chain stationary phase is simplified by the π-π interactions provided by a phenyl functionality. In this application PK95 a PET (Positron Emission Tomography) tracer exhibits resolution from its dechlorinated metabolite, which is not achievable on alkyl chain phases. High Selectivity Resolution enhanced Sharp Peak Shapes Fortis Phenyl 50x4.6mm 5μ FPH-050705 Mobile Phase: 40:60 H 2 O : ACN MS Detection. Dechlorinated PK95 2. PK95 353.00 (.00) 39.00 (.00) Data Courtesy of : Wolfson Molecular Imaging Centre 0 2.5 5 7.5 0 2.5 5 Doxazosin Quinidine Mobile Phase: Fortis Phenyl 50x4.6mm 5μ FPH-050705 30 : 60 H 2 O + 0.% formic acid MeOH 4 Mobile Phase: Fortis Phenyl 50x4.6mm 5μ FPH-050705 70 : 30 H 2 O + 0.% formic acid MeOH 80 60 254nm 2 235nm 40 0 20. Quinidine 2. Dihydroquinidine 00 80 80 60 60 0.0 2.0 3.0 4.0 5.0 6.0 0 2 4 6 8 0 2 4 6 8 20 www.fortis-technologies.com Tel: +44 5 336 2266

Fortis C8 Reduced Hydrophobicity over C8 Excellent Peak Shapes Fully Scalable 3,5,0μ C8 3% Fortis C8 is designed to provide characteristics similar to Fortis C8 but specifically for situations where less hydrophobicity is required. The same gains in peak shape, efficiency, resolution and scalability are available providing increased productivity to the analyst. L7 Optimised Peak Shape Following on from Fortis C8, whatever the compound functionality Fortis C8 is optimised to provide the best possible peak shapes and efficiency. Basic, Acidic and Neutral analyte performance is first class. Higher Efficiencies Greater Reproducibility Resolution enhanced Fortis C8 50x4.6mm 5μ F08-050705 Mobile Phase: A - H 2 O + 0.% Formic acid B - MeOH + 0.% Formic acid Gradient: 0-90% in 0min. Lamotrigine 254nm 8 6 4 2 Depakote Plavix Fortis C8 50x4.6mm 5μ F08-050705 Mobile Phase: 40 : 60 H 2 O + 0.% formic acid ACN 220nm Fortis C8 50x4.6mm 5μ F08-050705 Mobile Phase: 25 : 75 H 2 O : ACN 254nm. Valproate Semisodium. Clopidogrel 8.398 0.78 295 2.662.2 58942 6 6.088.6 864 2 www.fortis-technologies.com Tel: +44 5 336 2266

Part Number Tables Fortis C8 50 00 50 250 2. F8-0203xx F8-0205xx F8-0207xx - Column Diameter 3.0 F8-0303xx F8-0305xx F8-0307xx - 4.6 F8-0503xx F8-0505xx F8-0507xx F8-0509xx Fortis C8 Guards Length 0 Column Diameter 2. F8-0200xxG 4.6 F8-0500xxG Replace xx - 03 for 3µm - 05 for 5µm - 0 for 0µm Fortis H2o 50 00 50 250 2. FHO-0203xx FHO-0205xx FHO-0207xx - Column Diameter 3.0 FHO-0303xx FHO-0305xx FHO-0307xx - 4.6 FHO-0503xx FHO-0505xx FHO-0507xx FHO-0509xx Fortis H2o Guards Length 0 Column Diameter 2. FHO-0200xxG 4.6 FHO-0500xxG Replace xx - 03 for 3µm - 05 for 5µm - 0 for 0µm Fortis Phenyl 50 00 50 250 2. FPH-0203xx FPH-0205xx FPH-0207xx - Column Diameter 3.0 FPH-0303xx FPH-0305xx FPH-0307xx - 4.6 FPH-0503xx FPH-0505xx FPH-0507xx FPH-0509xx Fortis Phenyl Guards Length 0 Column Diameter 2. FPH-0200xxG 4.6 FPH-0500xxG Replace xx - 03 for 3µm - 05 for 5µm - 0 for 0µm Fortis C8 50 00 50 250 2. F08-0203xx F08-0205xx F08-0207xx - Column Diameter 3.0 F08-0303xx F08-0305xx F08-0307xx - 4.6 F08-0503xx F08-0505xx F08-0507xx F08-0509xx Fortis C8 Guards Length 0 Column Diameter 2. F08-0200xxG 4.6 F08-0500xxG Replace xx - 03 for 3µm - 05 for 5µm - 0 for 0µm If you do not see the required geometry above or if you require preparative columns then please contact sales@fortis-technologies.com to discuss your requirements. Fortis Fortis Pace columns are designed with High Throughput Screening (HTS) applications in mind. Optimised for use in LC-MS to provide greatest sensitivity by achieving sharp peak shapes combined with excellent resolution and retention. Fortis Pace 3μ 20 30 2. Fxx-02003 Fxx-020203 Fortis Pace 5μ 20 30 2. - Fxx-020205 Column Diameter 3.0 - Fxx-030203 Column Diameter 3.0 - Fxx-030205 Replace xx with: 8 for Fortis C8; HO for Fortis H2o; PH for Fortis Phenyl; 08 for Fortis C8 34 Coalbrookdale Road Clayhill Industrial Park Neston Cheshire, UK CH64 3UG t: +44 5 336 2266 f: +44 5 336 2669 www.fortis-technologies.com e: info@fortis-technologies.com