Agilent Cary 630 FTIR Spectrometer Supporting Organic Synthesis in Academic Teaching Labs

Similar documents
Agilent Cary 630 FTIR sample interfaces combining high performance and versatility

Confirmation of Coal Quality Using the Agilent ExoScan 4100 Handheld FTIR Spectrometer

Yin and yang in chemistry education: the complementary nature of FTIR and NMR spectroscopies

Non-Destructive Evaluation of Composite Thermal Damage with Agilent s New Handheld 4300 FTIR

Advanced Pharmaceutical Analysis

University of Wisconsin Chemistry 116 Preparation and Characterization of Aspirin and Some Flavoring Esters *

The DialPath Solution an Easier Way to Analyze Liquids By FTIR. Yanqia Wang, Ph.D. Application Engineer - FTIR Agilent Technologies May 7, 2015

Ester Synthesis And Analysis: Aspirin and Oil of Wintergreen. Vanessa Jones November 19, 2015 Thursday 8:30 Lab Section Lab Partner: Melissa Blanco

Positive and Nondestructive Identification of Acrylic-Based Coatings

Limiting Reagent Synthesis of Aspirin Thomas M. Moffett Jr., SUNY Plattsburgh, 2007.

Application note. Materials. Introduction. Author. John Seelenbinder Alan Rein. Agilent Technologies Danbury, CT, USA

ORG1 Syntheses of Acetaminophen and Aspirin

CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR

Detection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR

CHM Salicylic Acid Properties (r16) 1/11

The Synthesis and Analysis of Aspirin

2. Synthesis of Aspirin

Experiment 17. Synthesis of Aspirin. Introduction

Aspirin Lab By Maya Parks Partner: Ben Seufert 6/5/15, 6/8/15

b. The water is more attracted to the unreacted alcohol and acid than to the ester.

Experiment 8 Synthesis of Aspirin

Troubleshooting and quality control of polymers using micro-atr FTIR chemical imaging

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FTIR

Scheme 1. Outline in the acid-base extraction of Bengay, hydrolysis to salicylic acid, and esterification to synthesize aspirin.

Handheld FTIR spectroscopy applications using the Agilent ExoScan 4100 FTIR with diffuse sample interface

Chapter 25: The Chemistry of Life: Organic and Biological Chemistry

Acetylsalicylic Acid (Aspirin) Synthesis

In-Situ 13 C/ 12 C Ratio Analysis in Water Carbonates using FTIR

3 Steps to Simpler QA/QC of Polymeric Materials

Introduction to Fourier Transform Infrared Spectroscopy

Infrared Spectroscopy

SPECTROSCOPY MEASURES THE INTERACTION BETWEEN LIGHT AND MATTER

To understand concept of limiting reagents. To learn how to do a vacuum filtration. To understand the concept of recrystallization.

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FT-IR

Week 10 Chemical Synthesis

Aspirin Synthesis H 3 PO 4

Introduction to Fourier Transform Infrared Spectroscopy

Experiment 5 : The Diels-Alder reaction

ALPHA. Innovation with Integrity. The very compact and smart FTIR spectrometer FTIR

Structure of the chemical industry

Fanning. Synthesis of Camphor by the Oxidation of Borneol. Christine Fanning

Lecture 11. IR Theory. Next Class: Lecture Problem 4 due Thin-Layer Chromatography

A faster, more accurate way of characterizing cube beamsplitters using the Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

media), except those of aluminum and calcium

Experiment 8 Synthesis of Aspirin

(a) Name the alcohol and catalyst which would be used to make X. (2)

Analysis of Artificially Weathered PET and a Separate PET Hydrolysis Evaluation Using the 4300 Handheld FTIR

Preparation Of Aspirin Lab Report

Chemistry 2030 Introduction to Organic Chemistry Fall Semester 2012 Dr. Rainer Glaser

Module: 7. Lecture: 36

Infrared Spectroscopy

Ventura College COURSE OUTLINE OF RECORD

Chemistry 2050 Introduction to Organic Chemistry Fall Semester 2011 Dr. Rainer Glaser

Exp t 125. Oxidation of Borneol to Camphor. Reduction. Camphor. Borneol. Isoborneol

Preparation of an Ester Acetylsalicylic Acid (Aspirin)

Chemistry 2050 Introduction to Organic Chemistry Fall Semester 2011 Dr. Rainer Glaser

Chemistry 283g- Experiment 3

Chapter 10: Carboxylic Acids and Their Derivatives

1.1. IR is part of electromagnetic spectrum between visible and microwave

OH [H + ] KMnO 4 DME OH

Infrared spectroscopy. Siriphorn Laomanacharoen Bureau of Drug and Narcotic Department of Medical Sciences 2 March 2012

Infrared Spectroscopy: Identification of Unknown Substances

ORGANIC - BROWN 8E CH INFRARED SPECTROSCOPY.

Aspirin Synthesis. Figure 1 Acetylsalicylic acid (aspirin), C 9 H 8 O 4

CHEM 123L Lab Report. Synthesis of Acetaminophen. [Type the author name]

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

Rule 2. Rule 1. Rule 4. Rule 3. Rule 5. Rule 6. Rule 7. Rule 8

Intermolecular forces: Background

Exemplar for Internal Achievement Standard. Chemistry Level 3

Experiment # 13 PREPARATION OF ASPIRIN

Infrared Spectroscopy

Uses of GC/MS. Synthesis of 1-Bromobutane Butenes from 2-Butanol Fisher Esterification of Benzoic Acid Nitration of Methyl Benzoate

MOHAWK COLLEGE OF APPLIED ARTS AND TECHNOLOGY CHEMICAL AND ENVIRONMENTAL TECHNOLOGY DEPARTMENT. Lab Report ROOM NO: FE E309

DEPARTMENT: Chemistry

Experiment: Synthesis of Aspirin

Module: 7. Lecture: 36

1901 Application of Spectrophotometry

CHAPTER 8 ISOLATION AND CHARACTERIZATION OF PHYTOCONSTITUENTS BY COLUMN CHROMATOGRAPHY

Figure 1. Structures of compounds to be analyzed by IR.

4. Carbonyl chemistry

36B-BioOrganic Modifications for Technique Experiments. Technique of Thin-Layer Chromatography

Overview and comparison of portable spectroscopy techniques: FTIR, NIR and Raman

AQA A2 CHEMISTRY TOPIC 4.10 ORGANIC SYNTHESIS AND ANALYSIS TOPIC 4.11 STRUCTURE DETERMINATION BOOKLET OF PAST EXAMINATION QUESTIONS

CHEM 51LB: EXPERIMENT 7 SPECTROSCOPIC METHODS: INFRARED SPECTROSCOPY (IDENTIFICATION OF FUNCTIONAL GROUPS)

GRIGNARD REACTION Synthesis of Benzoic Acid

flowers, leaves and roots of roses rose oil heat

Methyl Salicylate Technical Package

EXPERIMENT 1 SYNTHESIS OF XANTHENE DYES USING ELECTROPHILIC AROMATIC SUBSTITUTION

FTIR Spectrometer. Basic Theory of Infrared Spectrometer. FTIR Spectrometer. FTIR Accessories

Synthesis of Tetraphenylcyclopentadienone. Becky Ortiz

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Molecular Geometry: VSEPR model stand for valence-shell electron-pair repulsion and predicts the 3D shape of molecules that are formed in bonding.

(a) The local anaesthetic procaine can be synthesised from benzoic acid. The simplified route is shown below. COOH

AP Chemistry Lab #5- Synthesis and Analysis of Alum (Big Idea 1 & 2)

CHMA2000 EXPT 7: The Physical and Chemical Properties of Alcohols

Organic Chemistry II (CHE ) Examination I February 11, Name (Print legibly): Key. Student ID#:

Synthesis Of Aspirin Discussion

Esterification of Salicylic Acid via Acetic Anhydride for the Pro- duction of Acetylsalicylic Anhydride (Aspirin)

Chapter 20: Identification of Compounds

Organic Spectra Infra Red Spectroscopy H. D. Roth. THEORY and INTERPRETATION of ORGANIC SPECTRA H. D. Roth. Infra Red Spectroscopy

Transcription:

Agilent Cary 630 FTIR Spectrometer Supporting Organic Synthesis in Academic Teaching Labs Application note Academic Author Frank Higgins and Alan Rein Agilent Technologies Danbury, CT, USA Introduction As it has been for the past half century, IR spectroscopy is a fundamental analytical technique that undergraduate organic chemistry students must understand and have the opportunity to use. The demands of the undergraduate labs require that FTIR spectrometers possess certain design attributes associated with the multiuser environment. The spectrometer must be easy to use, rugged, reliable, compact and cost attractive.

The recently introduced Cary 630 system (Figure 1) meets and exceeds these requirements and is an excellent choice for the undergraduate organic lab. In addition, it is equally at home in graduate level and research labs where organic chemists determine the identity and structure of synthesized compounds via a rapid IR analysis. Broad range of sampling interfaces available, handling liquids, solids and gases Overall performance and ease of use advantages translate into virtually all analyses requiring less than a minute to execute Optomechanical Components Permanently aligned interferometer and optical system results in an extremely reliable, everyday workhorse system Interferometer and optics are exceedingly rugged Cary 630 uses the same optomechanical components as those used in Agilent s portable and handheld industrial systems, which require the highest level of robustness Large aperture optics and short internal optical paths provides class-leading performance Sampling Interfaces No-alignment, interchangeable sampling accessories allow students to understand and readily practice different experimental methods transmission, ATR etc. Figure 1. The Agilent Cary 630 FTIR spectrometer (all photographic elements shown in context) Agilent Cary 630 FTIR Spectrometer features and benefits for academic organic synthesis applications in teaching and routine research support Overall System Design Most compact, superior performing FTIR available - ultracompact design preserves valuable bench top space Light weight allows system to be relocated, as needed Completely sealed optics and compact size enables use in standard fume hoods Sampling interfaces available include: diamond ATR, diffuse reflectance, solid, liquid and gas transmission as well as Agilent s innovative, exclusive DialPath technology for liquids analysis Diamond ATR sampling interface is ideal for analysis of reaction starting materials, reagents and product impervious to scratching and highly chemically resistant (ph 1-14) ATR sampling interface enables grab sample, neat reaction mixture analysis no sample dilution necessary Powder press, which ensures good optical contact of solids with ATR crystal, cannot be overtightened, i.e. diamond window cannot be damaged by overpressure Sample interface RFID ensures that methods are matched with appropriate sampling technologies 2

Software and User Interface Highly visual, intuitive software allows data acquisition with essentially no training required. Real-time spectrum display works in conjuction with ATR powder press to ensure adequate contact between solid samples and diamond ATR crystal. Experimental results can be stored under individual student s name or other identifier Student can verify identity of starting materials, isolated intermediate compounds and final products by comparison with spectra in on-board IR spectral library For more advanced experiments or analysis, data is readily transferrable to commercially available data analysis package. On-board diagnostics ensure peak operating efficiency Application example: Syntheses of esters of o-hydroxybenzoic acid A classic undergraduate organic chemistry experiment, which is also ideal for FTIR analysis, is the synthesis o-hydroxybenzoic acid esters, i.e.the condensation reaction of salicylic acid with methanol to form methyl salicylate (oil of wintergreen), and the esterification of salicylic acid with acetic anhydride to form acetylsalicylic acid (aspirin). This lab synthesis is particularly useful as a teaching tool because the synthesis is associated with product isolation, purification and the analysis of final product for purity and yield. Melting point, FTIR analysis and proton NMR are often employed in support of this teaching experience, so the student receives an understanding of how synergistic analysis provides a better overall understanding of chemistry. With respect to FTIR analysis, these reactions allow the student to measure solids, liquids and slurries using a variety of IR sampling methods. In the preparation of methyl salicylate, the starting materials and final product have highly characteristic infrared spectra (Figure 2). The diamond ATR sampling Figure 2. The IR spectra of methanol (red), salicylic acid (maroon), and methyl salicylate product (blue). interface is ideal for the measurement of these compounds, which are solids and liquids. For methanol reagent, the student simply puts a drop of the liquid on the diamond sensor and initiates analysis. A high quality spectrum only requires 2 seconds to collect and the system s rapid analysis capability is useful when volatile solvents or reagents are analyzed. For the solid salicylic acid starting material, a few grains are placed on the diamond sensor; the powder press is rotated downwards until enough contact is made so that a spectrum appears in the real-time spectrum display (Figure 3). After the reaction is complete, a drop of the oily product is placed on the diamond sensor Figure 3. Powder press ensures that solid sample is in contact with diamond ATR crystal to obtain high quality IR spectrum. Powder press design eliminates overtightening. Instantaneously refreshed spectra obtained in real-time analysis window shows that solid sample is in contact with the Diamond ATR crystal. 3

for IR analysis. If the instructor wishes, a sample of the reaction mixture can be taken periodically and the overall IR spectrum can show the progressive loss of reagent and formation of product as a function of reaction time. To enable the students to experience other methods for analyzing compounds by FTIR, the transmission module can be quickly mounted on the Cary 630 and a drop of the methyl salicylate product sandwiched between two IR sample windows can be analyzed for comparison to the data obtained via ATR. Acetylsalicylic acid is formed by the reaction of salicylic acid and acetic anhydride. Since acetic anhydride is a corrosive, irritating chemical, the Cary 630 FTIR should be placed in a fume hood. The student will also observe the chemical resistance of the diamond ATR, since a by-product of the reaction is acetic acid and a few drops of sulfuric acid are added to act as a catalyst. The IR spectrum (Figure 4) of these reagents and products are very indicative of their structure and composition. The student will be readily able to see the loss of the 1820 cm -1 acetic anhydride carbonyl bands with the concurrent formation of the characteristic 1745 cm -1 ester carbonyl vibration in the product. Periodic sampling of the reaction mixture shows the reaction progress as a function of time. As in the previous example, solid materials are analyzed using the powder press and liquids by placing a drop of the solution on the diamond window. For reaction mixtures that are either a slurry or where the solubility of the product is such that solids and liquids maybe present, the student will observe that the liquid phase of the reaction yields the strongest IR absorbances, and the powder press is required to ensure good optical contact between the solid components of the reaction mixture and the diamond window. Moreover, the student can determine the effectiveness of product purification by observing if the IR spectrum of starting material is still present in the isolated product. Conclusion The Cary 630 FTIR spectrometer has superior capabilities for the analysis of organic syntheses as either part of undergraduate teaching courses or as a routine spectrometer in support of graduate research. The unique combination of versatile sampling, ease of use, robust system components, combined with attractive pricing and low cost of long term operation meets the needs and requirements of the multiuser academic environment. Figure 4. IR spectrum of reagents salicylic acid (maroon), acetic anhydride (red) and product acetylsalicylic (blue) 4

Synthesis of o-hydroxybenzoic acid esters Use of infrared spectroscopy and analysis of spectra If the mixture that is formed from the reaction of salicylic acid and methanol is dried down and analyzed without purification, the students will observe the methyl CH stretch absorbance band at 2956 cm -1 ( see Figure 2) for methyl salicylate, along with bands from the unreacted salicylic acid starting material. Bands that the students should watch for is the loss of the salicylic acid broad OH---O stretch absorbance in the region from 2800-2200 cm -1 and the OH---O wag absorbance at 885 cm -1. If the reaction mixture is not dried down, but rather further heated on a hot plate at 100 C, methyl salicylate will condense on the sides of the vial. This clear oily condensate can be collected with a swab or plastic pipet for measurement on the diamond crystal for IR analysis. Very little of the liquid is necessary, the 1.5 mm diameter diamond only needs a thin film on its surface, to produce an excellent infrared spectrum of the product. The carbonyl region of the IR spectra of salicylic acid, methyl salicylate, and acetylsalicylic acid makes for an interesting study on how IR can be used to characterize hydrogen bonding influences on carbonyl group frequencies. Hydrogen bonding lowers the carbonyl group frequency in the IR spectrum and under normal conditions, the carboxylic acid group forms a H-bonded dimer at 1710-1700 cm -1 The carbonyl frequency can shift as high as 1750 cm -1 when analyzed in the gaseous state (no H-bonding is possible) or in very dilute solution in a non-polar solvent. The carboxylic acid carbonyl band (COOH) for salicylic acid (Figure 4) is lower in frequency (1655 cm -1 ) than that in acetylsalicylic acid (1678 cm -1 ). This is due to the slight very weak hydrogen bonding influence from the phenolic OH group present in the salicylic acid and not in the aspirin, which is enough to disturb the dimer found in normal non-influenced aromatic COOH. Benzoic acid which has no phenolic OH group has the carboxylic acid dimer absorbance at 1678 cm -1, nearly identical to that in acetylsalicylic acid. Interestingly, the methyl ester in methyl salicylate (Figure 2) is at the same frequency (1678 cm -1 ) as the carboxylic acid groups. This is due to the slight hydrogen bonding from the phenolic OH group, which is either intramolecular, intermolecular, or a mix of both H-bonded states, since the normal aromatic methyl ester without a phenolic OH group should be much higher at ~1730 cm -1, such as in orthophthalates. 5

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc. 2011 Published Month September 1, 2011 Publication number: 5990-8921EN