Test Results: Results of the test period on 06/19/16 using the Equivalent CTS Method: Thermal transmittance at test conditions (U s ):

Report No: NCTL NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 12/14/15

Report No: NCTL S NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 07/14/15. Test Specimen

THERMAL PERFORMANCE TEST REPORT

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: C.R. LAURENCE CO., INC.

NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 03/31/06

NFRC THERMAL TEST SUMMARY REPORT January 27, 1999 Test Specimen

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NORTH EAST WINDOWS USA, INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NU VISTA WD, INC. SERIES/MODEL: Malibu 250 T TYPE: Fixed

SHANGHAI MYLCH WINDOWS & DOORS THERMAL PERFORMANCE TEST REPORT

NFRC SOLAR HEAT GAIN COEFFICIENT TEST REPORT. Rendered to: CLEAR FOCUS IMAGING

ASTM C THERMAL PERFORMANCE TEST REPORT. Rendered to: UNIVERSAL PULTRUSIONS, LLC. PRODUCT: Fiberglass Door Slab

WINDOW SIMULATION REPORT

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: PARAMOUNT WINDOWS CORPORATION. SERIES/MODEL: 4000 TYPE: Fixed

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM. SERIES/MODEL: 7400 TYPE: Fixed

Standard Test Method for Measuring the Steady-State Thermal Transmittance of Fenestration Systems Using Hot Box Methods 1

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: INTERNATIONAL ARCHITECTURAL PRODUCTS, INC. DBA: UNITED STATES ALUMINUM

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: CMI ARCHITECTURAL PRODUCTS, INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: TUBELITE, INC.

SIMULATION TEST REPORT NCTL E0A0

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: C.R. LAURENCE CO., INC.

Simulation Report (Revised) Rendered To: Showcase Custom Vinyl Windows 1002 Olde Towne Drive Irving, TX 75061

Winter Night. Thermos 6mm Outdoors # #

THE EFFECTS OF CALORIMETER TILT ON THE INWARD-FLOWING FRACTION OF ABSORBED SOLAR RADIATION IN A VENETIAN BLIND

TEST METHOD FOR THERMAL TRANSMITTANCE AND AIR INFILTRATION OF GARAGE DOORS

THERMAL TRANSMITTANCE OF MULTI-LAYER GLAZING WITH ULTRATHIN INTERNAL PARTITIONS. Agnieszka A. Lechowska 1, Jacek A. Schnotale 1

CAE 331/513 Building Science Fall 2016

Solar Radiation 230 BTU s per Hr/SF. Performance Glazing Coatings, Layers & Gases

CAE 463/524 Building Enclosure Design Fall 2012

National Fenestration Rating Council. Incorporated. NFRC [E0A1] Procedure for Determining Fenestration Product Condensation Resistance Values

ASTM C STEADY-STATE HEAT FLUX MEASUREMENTS AND THERMAL TRANSMISSION PROPERTIES BY MEANS OF THE HEAT FLOW METER APPARATUS

Determination of thermal transmittance of window (test title)

Window air permeability measurement, watertightness and resistance to wind load (designation of the test)

TEST OF MEASURED SOLAR HEAT GAIN VARIATION WITH RESPECT TO TEST SPECIMEN TILT

Calculating the heat transfer coefficient of frame profiles with internal cavities

Vincent Barraud SOPREMA BASICS OF THERMAL INSULATION

Determination of installed thermal resistance into a roof of TRISO-SUPER 12 BOOST R

AR/IA 241 LN 231 Lecture 4: Fundamental of Energy

Radiant Heating Panel Thermal Analysis. Prepared by Tim Fleury Harvard Thermal, Inc. October 7, 2003

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA. EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562

ISO INTERNATIONAL STANDARD

Customer: Ashton Industrial Sales Ltd. South Road, Harlow Essex CM20 2AR UNITED KINGDOM. Project/Customer: Profilex HM spacer

Assessing The Thermal Performance of Building Enclosure Materials Using A Medium-Size Hot Box Chamber Summer Meeting Torkan Fazli

QIRT th International Conference on Quantitative InfraRed Thermography

The Electrodynamics of a Pair of PV Modules with Connected Building Resistance

Building Envelope Requirements Overview Page 3-4

the distance of conduction (the thickness), the greater the heat flow.

Determining of Thermal Conductivity Coefficient of Pressed Straw (Name of test)

Standard Guide for Determination of the Thermal Resistance of Low-Density Blanket-Type Mineral Fiber Insulation 1

Performance Assessment of PV/T Air Collector by Using CFD

INVESTIGATING GLAZING SYSTEM SIMULATED RESULTS WITH REAL MEASUREMENTS

Design strategy for Low e windows with effective insulation

ISO INTERNATIONAL STANDARD. Thermal performance of windows, doors and shutters Calculation of thermal transmittance Part 1: Simplified method

Reflectec Thermal Fabric & Reflectec Fiberboard

UNIT FOUR SOLAR COLLECTORS

PERFORMANCE EVALUATION OF REFLECTIVE COATINGS ON ROOFTOP UNITS

ESRL Module 8. Heat Transfer - Heat Recovery Steam Generator Numerical Analysis

Use of Phase-Change Materials to Enhance the Thermal Performance of Building Insulations

Available online at ScienceDirect. Energy Procedia 57 (2014 ) ISES Solar World Congress

Coolant. Circuits Chip

Law of Heat Transfer

BACK TO BASICS: PIPE INSULATION

INDUSTRIAL INSULATION for Systems Operating Above Ambient Temperature

TEST METHOD FOR STILL- AND FORCED-AIR JUNCTION-TO- AMBIENT THERMAL RESISTANCE MEASUREMENTS OF INTEGRATED CIRCUIT PACKAGES

Heat Transfer: Physical Origins and Rate Equations. Chapter One Sections 1.1 and 1.2

CRYOGENIC CONDUCTION COOLING TEST OF REMOVABLE PANEL MOCK-UP FOR ITER CRYOSTAT THERMAL SHIELD

THE IMPORTANCE OF INDOOR AND OUTDOOR AIR-FILM COEFFICIENT MEASUREMENT TO SOLAR CALORIMETERY

Thermal and mechanical modeling of thermal breaks in structural steel point transmittances

Arctice Engineering Module 3a Page 1 of 32

Chapter 11. Energy in Thermal Processes

Warm surfaces warm edges Insulated glass with thermally improved edge seal

Solar Flat Plate Thermal Collector

Effect of Installing a Curved Venetian Blind to the Glass Window on Heat Transmission

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois

q x = k T 1 T 2 Q = k T 1 T / 12

DESIGN AND COST ANALYSIS OF HEAT TRANSFER EQUIPMENTS

SAMPLE ASSESSMENT TASKS PHYSICS ATAR YEAR 11

Response function method

Review: Conduction. Breaking News

Collector test according to EN ,2:2002

of PASSIVE Europa 92 door with 44mm & 48mm glazing for Zyle Fenster UAB J. Jasinskio 16a LT Lithuania

Making Decisions with Insulation

Heat Tracing Basics. By: Homi R. Mullan 1

TRANSPARENT INNOVATIVE MATERIALS: ENERGETIC AND LIGHTING PERFORMANCES EVALUATION

Effective Thermal Conductivity of High Temperature Insulations for Reusable Launch Vehicles

PAPER 2 THEORY QUESTIONS

Coupled CFD/Building Envelope Model for the Purdue Living Lab

Development and Validation of Flat-Plate Collector Testing Procedures

A quantitative infrared thermography method for the assessment of windows thermal transmittance

COMPARISON OF GUNN BELLANI RADIOMETER DATA WITH GLOBAL SOLAR RADIATION SENSOR (PYRANOMETER CM6B) Author. Mungai Peter N.

CONSTRUCTION MATERIALS

Science 1206 Weather Unit REVIEW Short Answer

SENSOR. Weather TRANSMITTERS

Composite Conductor Field Trial Summary Report: Western Area Power Administration Phoenix

Elmahdy, A.H.; Haddad, K. NRCC-43378

5. AN INTRODUCTION TO BUILDING PHYSICS

Simpo PDF Merge and Split Unregistered Version -

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. PRODUCT: SUN TUNNEL Domes TYPES: Acrylic and Polycarbonate

PURE PHYSICS THERMAL PHYSICS (PART I)

Transcription:

1320, boul. Lionel-Boulet, Varennes (Quebec) J3X 1P7 Tél. : (450) 652-0838 Fax : (450) 652-7588 info@air-ins.com THERMAL PERFORMANCE VALIDATION TEST CONDUCTED ON YOUR 300 / 301 FIXED WINDOW IN ACCORDANCE WITH NFRC 102-2004 Prepared for: GREAT LAND WINDOW 2401 COLLEGE ROAD FAIRBANKS, AK, USA 99709 CHIP VAUGHAN 907-479-6437 AIR-INS INC. Reissued report: NV-00894-B 1320 Boul. Lionel-Boulet Date : February 9, 2011 Varennes, Québec J3X 1P7 Tél: (450) 652-0838 Number of pages: 4 Fax: (450) 652-7588 written approval of Air-Ins Inc.

TABLE OF CONTENTS 1.0 INTRODUCTION...1 2.0 SPECIFICATION...1 3.0 DESCRIPTION OF THE SPECIMEN TESTED...1 4.0 SPECIMEN PREPARATION PRIOR TO TEST...2 5.0 TEST PARAMETERS...2 6.0 RESULTS...2 APPENDIX A: DRAWINGS AND PRODUCT INFORMATIONS written approval of Air-Ins Inc.

1.INTRODUCTION This report is reissued for initial certification to Great Land Window with the authorization of Inline Fiberglass Ltd. Consequently, no test sample was submitted. Initially Air-Ins Inc. Laboratories has been retained by Inline Fiberglass Ltd. to test a fixed window in accordance with NFRC 102-2004 Procedure for Measuring the Steady-State Thermal Transmittance of Fenestration Systems, 2004 edition. The sample components and manufacturing are documented in section 3.0. Ratings included in this report are for submittal to an NFRC-licensed IA for certification purposes and are not meant to be used for labelling purposes. Only those values identified on a valid Certification Authorization Report (CAR) are to be used for labelling purposes. 2.SPECIFICATION NFRC 102-2004 Procedure for Measuring the Steady-State Thermal Transmittance of Fenestration Systems, 2004 edition 3.DESCRIPTION OF THE TESTED SPECIMEN Type: Operator Type: FIXD Submitted for: Production Line Initial certification Size: 1200 mm W. x 1500 mm H. (47.24 x 59.06 ) Model: Frame Material: FG Glazing: 300 / 301 Fixed Type: Quadruple Sealed Unit Total thickness: 35,21 mm (1.40 ) *Type of glass: Glass 1: 4,03 mm (0.16 ) Low-e S-2 e=0.04 Glass 2: Film (*HMTC88) Low-e S-3 e=0.13, S-4 e=0.11 Glass 3: Film (*HMTC88) Low-e S-5 e=0.13, S-6 e=0.11 Glass 4: 4,03 mm (0.16 ) Low-e S-7 e=0.04 Gap thickness: Gap 1: 9,05 mm (0.36 ) *Type of spacer: *Design gas fill: *Filling technique: *Gas concentration: *Data obtained by the manufacturer Gap 2: 9,05 mm (0.36 ) Gap 3: 9,05 mm (0.36 ) Steel spacer (CS-D) Krypton Single Probe 10% Air, 90% Krypton Date of test: September 25, 2007 Thermal Transmittance (Us) : Standardized Thermal Transmittance (Ust) : 1,03 W/(m²C) (0.18 BTU/(hr ft² F)) 1,03 W/(m²C) (0.18 BTU/(hr ft² F)) written approval of Air-Ins Inc. 1/4

4.SPECIMEN PREPARATION PRIOR TO TEST The test specimen was preconditioned at ambient laboratory conditions prior to the test. The surround panel-tospecimen interfaces were sealed with a non-reflective tape. The specimen was sealed on the exterior with a non-reflective tape. 5.TEST PARAMETERS Tests to determine the Standardized Thermal Transmittance (Ust) of the specimen were performed in the guarded hot box located at Varennes, Quebec. The most recent calibration of the hot box apparatus was in August 01, 2007. The thermal performance evaluations were completed in accordance with the NFRC Test Procedure using a dynamic wind perpendicular to the specimen on the weather side and simulated natural convection on the room side. A zero static pressure differential was maintained across the specimen during the test by pressurizing the guard box on the room side. Data was collected over two successive 2 hour periods after 4 hours of steady state conditions as defined in section 5.2.1.A of the NFRC Test Procedure. 6.RESULTS Measured Test Data Glass Thickness and Glazing Deflection (Metric units) (Imperial Units) 1. Glazing Deflection Before Test : 0.40 mm ( 0.02 ) inch 2. Glazing Deflection During Test : 1.59 mm ( 0.06 ) inch Heat Flows (Metric units) (Imperial Units) 1. Total Measured Input into Metering Box (Qtotal) : 113.84 W ( 388.78 ) BTU/hr 2. Surround Panel Heat Flow (Q sp ) : 46.85 W ( 159.99 ) BTU/hr 3. Metering Box Wall Heat Flow (Q mb ) : 0.10 W ( 0.35 ) BTU/hr 4. Flanking Loss Heat Flow (Q fl ) : -5.55 W ( -18.94 ) BTU/hr 5. Net Specimen Heat Loss (Q s ) : 72.44 W ( 247.39 ) BTU/hr Areas (Metric units) (Imperial Units) 1. Test Specimen Projected Area (A s ) : 1.80 m² ( 19.38 ) ft² 2. Test Specimen Interior Total (3-D) Surface Area (A int ) : 1.85 m² ( 19.93 ) ft² 3. Test Specimen Exterior Total (3-D) Surface Area (A ext ) : 1.85 m² ( 19.93 ) ft² 4. Metering Box Opening Area (Amb) : 5.75 m² ( 61.84 ) ft² 5. Metering Box Baffle Area (A b1 ) : 5.40 m² ( 58.11 ) ft² 6. Surround Panel Interior Exposed Area (Asp): 3.95 m² ( 42.47 ) ft² written approval of Air-Ins Inc. 2/4

Test Conditions (Metric units) (Imperial Units) 1. Average Metering Room Air Temperature : 21.06 C ( 69.90 ) F 2. Average Cold Side Air Temperature : -17.91 C ( -0.24 ) F 3. Average Guard/Environmental Air Temperature : 21.64 C ( 70.95 ) F 4. Metering Room Maximum Relative Humidity : 12.44 % ( 12.44 ) % 5. Measured Cold Side Wind Velocity: 14.64 km/h ( 9.10 ) mph 6. Measured Metering Side Wind Velocity: 2.00 km/h ( 1.24 ) mph 7. Measured Maximum Static Pressure Difference Across Specimen : 4.08 Pa ( 0.09 ) psf Surface Temperature Data (Metric units) (Imperial Units) 1. Area-Weighted Surround Panel Warm Side Surface Temperature: 19.97 C ( 67.95 ) F 2. Area-Weighted Surround Panel Cold Side Surface Temperature : -17.20 C ( 1.04 ) F Results (Metric units) (Imperial Units) 1. Thermal Transmittance of Test Specimen (U s ) : 1.03 W/(m²C) ( 0.18 ) BTU/(hrft² F) 2. Standardized Thermal Transmittance of Test Specimen (U st ) : 1.03 W/(m²C) ( 0.18 ) BTU/(hrft² F) Calculated Test Data, Method B (Equivalent CTS Method) : (Metric units) (Imperial Units) 1. Emittance of Glass (e 1 ) : 0.84 0.84 2. Warm Side Baffle Emittance (e b1 ) : 0.91 0.91 3. Equivalent Warm Side Surface Temperature: 15.22 C ( 59.39 ) F 4. Equivalent Weather Side Surface Temperature: -16.53 C ( 2.25 ) F 5. Warm Side Baffle Surface Temperature: 20.86 C ( 69.55 ) F 6. Measured Warm Side Surface Conductance (h I ) : 6.89 W/(m²C) ( 1.21 ) BTU/(hrft² F) 7. Measured Weather Side Surface Conductance (h II ) : 29.06 W/(m²C) ( 5.12 ) BTU/(hrft² F) 8. Test Specimen Thermal Conductance (C s ) : 1.27 W/(m²C) ( 0.22 ) BTU/(hrft² F) W/ BTU/ 9. Convection Coefficient (K) : 1.61 (m²c 1,25 ) ( 0.28 ) (hrft² F 1,25 ) 10. Radiative Test Specimen Heat Flow (Q r1 ) : 45.42 W ( 155.13 ) BTU/hr 11. Conductive Test Specimen Heat Flow (Q c1 ): 27.01 W ( 92.26 ) BTU/hr 12. Radiative Heat Flux of Test Specimen (q r1 ) : 25.24 W/m² ( 8.01 ) BTU/(hr ft²) 13. Convective Heat Flux of Test Specimen (q c1 ): 15.01 W/m² ( 4.76 ) BTU/(hr ft²) 14. Standardized Warm Side Surface Conductance (h sti ): 6.76 W/(m²C) ( 1.19 ) BTU/(hrft² F) 15. Standardized Cold Side Surface Conductance (h stii ) : 30.00 W/(m²C) ( 5.28 ) BTU/(hrft² F) 16. Standardized Thermal Transmittance (U st ) : 1.03 W/(m²C) ( 0.18 ) BTU/(hrft² F) Test Duration 1. The environmental systems were started at : 21:45 on 2007-09-24 2. The test parameters were considered stable for two consecutive two hour test periods from: 7:30 to 11:30 on 2007-09-25 3. The thermal performance test results were derived from: 13:30 to 15:30 on 2007-09-25 written approval of Air-Ins Inc. 3/4

This test method does not include procedures to determine the heat flow due to either air movement through the specimen or solar radiation effects. As a consequence, the thermal transmittance results obtained do not reflect performances which may be expected from field installations due to not accounting for solar radiation, air leakage effects, and the thermal bridge effects that may occur due to the specific design and construction of the fenestration system opening. Therefore, it should be recognized that the thermal transmittance results obtained from this test method are for ideal laboratory conditions and should only be used for fenestration product comparisons and as input to thermal performance analyses which also include solar, air leakage, and thermal bridge effects. Detailed drawings were available for laboratory records and compared to the test specimen at the time of this report. A copy of this report along with representative sections of the test specimen will be retained by Air-Ins Inc. for a period of four (4) years. The results obtained apply only to the specimen tested. Testing described in this report was conducted in full compliance with NFRC requirements. Appendix A of this report includes drawings and information of the product. Dave Deshaies McMahon, Eng. Gilbert Riopel, B.Sc. Program Director Person-in-Responsible Charge written approval of Air-Ins Inc. 4/4

APPENDIX A: DRAWINGS AND PRODUCT INFORMATIONS written approval of Air-Ins Inc.