Lab 10 Guide: Column Chromatography (Nov 3 9)

Similar documents
Lab 6 Guide: Extraction (Sept 29 Oct 5)

Chromatography: Thin-Layer Chromatography (TLC) & Column Chromatography

Prelab Reading Assignment: Laboratory Techniques in Organic Chemistry, 4 th Ed. Chapter 19

Nucleophilic displacement - Formation of an ether by an S N 2 reaction The Williamson- Ether Synthesis

EXPERIMENT #1 SEPARATION AND RECOVERY OF ORGANIC COMPOUNDS, THIN LAYER CHROMATOGRAPHY, COLUMN CHROMATOGRAPHY, CRYSTALLIZATION AND MELTING POINTS

Exp 1 Column Chromatography for the Isolation of Excedrin Components. Reading Assignment: Column Chromatography, TLC (Chapter 18)

Spring Renan Gongora Week Two: Extraction

CHEMICAL SEPARATION EXPERIMENT 2

Chromatography Extraction and purification of Chlorophyll CHM 220

Exercise 4: Thin layer chromatography of organic compounds

Ester Synthesis And Analysis: Aspirin and Oil of Wintergreen. Vanessa Jones November 19, 2015 Thursday 8:30 Lab Section Lab Partner: Melissa Blanco

6. Extraction. A. Background. (a) (b) (c) Figure 1. Mixing of Solvents

For Chromatography, you might want to remember Polar Dissolves More, not like dissolves like.

6. Extraction. A. Background. (a) (b) (c) Figure 1. Mixing of Solvents

Extraction. weak base pk a = 4.63 (of ammonium ion) weak acid pk a = 4.8. weaker acid pk a = 9.9. not acidic or basic pk a = 43

Lab #3 Reduction of 3-Nitroacetophenone

Experiment 1: Thin Layer Chromatography

2. Synthesis of Aspirin

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

Some Useful and Practical Tips for! Flash Chromatography! February 14th 2008!

Thin Layer Chromatography

Experiment 1: Extraction and Thin Layer Chromatography

General Chemistry I CHEM-1030 Laboratory Experiment No. 2 Physical Separation Techniques

Review Questions for the Chem 2315 Final Exam

Chromatography Lab # 4

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

SYNTHESIS OF AN AZO DYE revisited (1 or 2 credits)

Mixtures 1 of 38 Boardworks Ltd 2016

Laboratory Exercise: Chromatographic Separation

Methods of Separation. Vacuum Filtration. Distillation. The Physical Separation of Matter Chemistry 11 2/17/2014

Abstract. Introduction

Experiment Nine Thin Layer Chromatography

Open Column Chromatography, GC, TLC, and HPLC

Multistep Synthesis of 5-isopropyl-1,3-cyclohexanedione

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

LAB #6 Chromatography Techniques


Lab 3 Guide: Gas Chromatography (GC) (Sept 8-14)

Page 1. Electronic Supplementary Material (ESI) for Green Chemistry This journal is The Royal Society of Chemistry 2012

REACTIONS: Reduction of a ketone, acetylation of an alcohol, and a kinetic resolution using a lipase.

Experimental techniques

CfE Higher Chemistry. Unit 3: Chemistry in Society. Chemical Analysis as part of quality control

REACTIONS: Reduction of a ketone, acetylation of an alcohol, and a kinetic resolution using a lipase.

CHEM 304 Experiment Prelab Coversheet

Physical Separations and Chromatography

Experiment 1: The Borohydride Reduction of 9-Fluorenone to 9-Fluorenol

5.37 Introduction to Organic Synthesis Laboratory

Thin Layer Chromatography

Chromatography & instrumentation in Organic Chemistry

CHAPTER 8 ISOLATION AND CHARACTERIZATION OF PHYTOCONSTITUENTS BY COLUMN CHROMATOGRAPHY

3. Two unknown samples are found to have the same R f value under identical TLC conditions. Are they the same compound? Explain.

Experiment 1 & 2 PURPOSE OF THE EXPERIMENT

91 PERCENTAGE COMPOSITION

Optimized Flash Chromatography Purification: From TLC to large scale in three steps

SYNTHESIS OF AN AZO DYE revisited (1 or 2 credits)

CH204 Experiment 2. Experiment 1 Post Game Show. Dr. Anderson s Favorite Uses for Diet Coke. 1. Density Experiments 2. Diet Coke + Mentos Sticky Fun!

Chromatography: Candy Coating and Marker Colors Student Advanced Version

Green Chemistry Experiment: A Template-Directed [2+2] Photodimerization Conducted in the Solid State

Laboratory 1 CSI Meadville: Preparative purification of a mixture

Exp t 125. Oxidation of Borneol to Camphor. Reduction. Camphor. Borneol. Isoborneol

Experiment 8 Synthesis of Aspirin

PURPOSE: To separate the pigments of spinach by Column Chromatography. To analyze Column Chromatography fractions by Thin Layer Chromatography.

THE CATHOLIC UNIVERSITY OF EASTERN AFRICA A. M. E. C. E. A

18 Macroscale and Microscale Organic Experiments

3. Separation of a Mixture into Pure Substances

To understand concept of limiting reagents. To learn how to do a vacuum filtration. To understand the concept of recrystallization.

2 nd exam of the 1 st term for 2 nd ESO G. 1. Look at the following picture:

Synthesis and Use of QCy7-derived Modular Probes for Detection and. Imaging of Biologically Relevant Analytes. Supplementary Methods

COEFFICIENTS. - Experimentally, we can usually determine the reactants and products of a reaction

Column Liquid Chromatography Experiment Adapted for Use in Secondary Schools

Name Period Date. Lab 10: Paper Chromatography

EXPERIMENT: LIMITING REAGENT. NOTE: Students should have moles of reactants in DATASHEET converted into masses in grams prior to the lab period.

Experiment 7 - Preparation of 1,4-diphenyl-1,3-butadiene

CHEMISTRY Organic Chemistry Laboratory II Spring 2019 Lab #3: Friedel-Crafts Acylation

(2) After dissolving a solid in a solvent at high temperature, the solution is not filtered.

Practical 1 Procedure Iron by Titrimetry

Volumetric Analysis. Quantitative analysis answers the second question

Chromatography Outline

Micelles-Enabled Photo-Assisted Selective Oxyhalogenation of Alkynes in Water Under Mild Conditions. Supporting Information

Acid-Base Extraction

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

Experiment # 13 PREPARATION OF ASPIRIN

How to build and race a fast nanocar Synthesis Information

CHEMICAL CALCULATIONS - RELATING MASS AND ATOMS

CHEMISTRY Organic Chemistry Laboratory II Spring 2019 Lab #1: Oxidation of Alcohols to Ketones - Borneol Oxidation (2 weeks)

Paper Chromatography Lab. Prepared for: Mrs. Freeman

5072 CHEMISTRY (NEW PAPERS WITH SPA) TOPIC 1: EXPERIMENTAL CHEMISTRY 5067 CHEMISTRY (NEW PAPERS WITH PRACTICAL EXAM) TOPIC 1: EXPERIMENTAL CHEMISTRY

Chromatography 1 of 26 Boardworks Ltd 2016

The Fragrance of Rum, Isobutyl Propionate

Name Class Date. How do mixtures differ from elements and compounds? How can mixtures be separated? What are solutions?

Is There a Chemist in You?

Rule 2. Rule 1. Rule 4. Rule 3. Rule 5. Rule 6. Rule 7. Rule 8

North East Regional Heat Schools Analyst Competition Analysis of Two Fizzy Drinks

Exp 2 Acid-Base Extraction and Isolation of Excedrin Components

Chromatography and Functional Group Analysis

LUMEFANTRINUM LUMEFANTRINE

Chromatography. What is Chromatography?

MIXTURES, COMPOUNDS, & SOLUTIONS

Introductory Remarks:

CHEMISTRY Organic Chemistry Laboratory II Spring 2019 Lab #2: Grignard Reaction: Preparation of Triphenylmethanol

Transcription:

Lab 10 Guide: Column Chromatography (Nov 3 9) Column Chromatography/ Isolation of Caffeine from Tea, Exp. 7B, pages 67-72 in Taber After an organic reaction it s common to get a mixture of products. Usually one of them is what you want, and the other products are, well, garbage. Column chromatography is the method most commonly used to purify your product and remove undesired side products. How Column Chromatography Works Let s say you had a mixture of compounds A and B. How can you separate them? The first thing to do would be to run a TLC on the two compounds to see if they have different R f values. If so, that means they also have different polarities; the higher the R f value, the less polar the compound. So in this case compound A would be the less polar compound. As long as they have different polarities you can run a flash column. That is, perform column chromatography to separate the two compounds. The idea is that both columns enter the column (or tube) at the same time, but exit the columns at different times, so we can isolate them as they exit. Page 1 of 6

Lab 10 Guide: Column Chromatography (Nov 3 9) Page 2 of 6 How to Run a Column To run a column you dissolve your mixture of compounds A and B in an eluent solution- usually a mixture of ethyl acetate and hexanes. The eluent solution then travels through a glass tube filled with silica gel- this is your chromatography column. Silica gel is polar, so the more polar compound B will stick to the silica gel because of like dissolves like. Because compound A is less polar it will travel through the column faster than compound B. In technical terms, the silica gel is your stationary phase and the eluent solution is the mobile phase. More polar compound B has a higher affinity for the stationary phase than less polar compound A. The eluent solution is collected in fractions as it exits the column. So far example, the first 5 ml will be placed in test tube #1, the second 5 ml in test tube #2, and so on. This allows you to carefully separate your product using TLC analysis. In the TLCs below, fractions 1-7 contain compound A. It looks like there is some A in fractions 8-14, but not much. Compound B starts to come out around fractions 15-21, but really starts to come off the column in fractions 21-28. Notice that the less polar compound (A) came off the column first.

Lab 10 Guide: Column Chromatography (Nov 3 9) Page 3 of 6 Collecting Your Product Let s say you wanted to collect compound A. Then from the TLC above, you would take the liquid contents of test tubes 1-14 and transfer them to a pre-weighed round bottom flask. You would then evaporate the liquid in that round bottom on a rotovap and afterward you d find a white solid on the walls of the glass- this is your product. Note: It s important to weight the round bottom flask BEFORE you transfer the liquid! This allows you to weigh your product by difference. Key Column Chromatography Concepts The Effect of Solvent Polarity As with TLC, the more polar your solvent, the faster everything travels through your stationary phase. Much of the time you ll be using an ethyl acetate (Ea or EtOAc) and hexane (Hex) system. The higher the percentage of ethyl acetate is the more polar your system will be. If your system is too polar your compounds might come out too quickly resulting in a poor separation- after all, if you collect everything in a few test tubes you ll have nothing to separate. Likewise, if your system is too non-polar your column will take forever to run.

Lab 10 Guide: Column Chromatography (Nov 3 9) Page 4 of 6 Column Eluent vs. TLC Solvent Just a quick note- you normally don t run your TLCs using the same EtOAc/Hex solution as you use to run the column. For example, you might use 1:6 EtOAc-hex solution to run your column, but use 1:4 EtOAc- Hex solution for your TLC plates. (This was the case in the diagram above). This is because column chromatography is better at separating molecules than TLC is; using the same polarity solvent, you ll get a better separation with column chromatography than with TLC. How to Tell What Compounds Will Be More Polar or Less Polar As a general rule, a compound with a hydroxyl ( OH) group will be much more polar than one without. The Purpose of Sand in a Column It s good practice to put a layer of sand above and below the layer of silica gel. This is so the silica gel is level (flat). If you have ditches and mounds at the top of your silica gel you will get a poor separation because your compounds will not enter the column evenly. This is the purpose of sand. When liquid hits the sand ditches and mounds form, but the silica gel remains flat and even. (It s OK if the sand is uneven).

Lab 10 Guide: Column Chromatography (Nov 3 9) Page 5 of 6 Keep the Column Wet to Avoid Cracks Once the silica gel has been soaked in eluent solution it s important to avoid letting it run dry. You do this by making sure that the solvent level never goes below the silica gel; add more solvent as you run your column. What happens if your column runs dry? Then cracks start to form in the silica gel and you will be a poor separation. Plain English Procedure Sorry- this lab is a little long. Step 1: Extract Caffeine from Tea While one of you is doing step 1 have your partner setup step 2! In a sep funnel add ~40 ml of brewed tea and 20 ml of 5% HCl solution. You will then extract with 4 x 10 ml portions of dichloromethane (DCM). The DCM will be the lower layer. Collect the ~40 ml of DCM and dry it over sodium sulfate (to remove any water). (This step isn t really necessary; silica gel sucks up water very well). Then transfer your DCM to a round bottom flask (RB flask) and remove solvent via rotovap. If you used sodium sulfate, you should filter the DCM through a cotton plug so the sodium sulfate gets left behind. After the evaporation you should be left with a white powder- that s caffeine. Step 2: Run a Column Your text says to measure out 0.7 g of silica gel- don t do this. Just fill up the column about ~50-60% high with silica gel. Add a layer of sand on top. You will be doing a gradient elution, meaning you will be changing the eluent solution you use (first 100% DCM, then 95:5 DCM-EtOAc, and then 100% EtOAc). Dissolve your solid caffeine in your first eluent solution (100% DCM) and run the column with a total of 15 ml of DCM, collecting ~5 ml in each test tube. Then use two 5-mL portions of 95:5 DCM-EtOAc, and then three 5-mL portions of 100% EtOAc. In the end you ll have 8 test tube with about ~5 ml of solvent in each.

Lab 10 Guide: Column Chromatography (Nov 3 9) Page 6 of 6 Use TLC analysis to determine which fractions contain caffeine. (Your TLC solution will be provided by your TA). Finally, transfer those fractions that contain caffeine into a pre-weighed round bottom flask and evaporate the solvent using the rotovap. Weigh by difference to determine the amount of caffeine you recovered. You will probably have to let the caffeine dry in your lab drawer for a week before you can take a melting point.