OPTIMAL OBSERVABILITY OF PMU'S USING ANALYTIC HIERARCHY PROCESS (AHP) METHOD

Similar documents
Mixed Integer Linear Programming and Nonlinear Programming for Optimal PMU Placement

Optimal PMU Placement

Role of Synchronized Measurements In Operation of Smart Grids

Advances in Environmental Biology

Critical Measurement Set with PMU for Hybrid State Estimation

Extended Optimal PMU Placement Problem for Voltage Stability Assessment

OPTIMAL PLACEMENT AND UTILIZATION OF PHASOR MEASUREMENTS FOR STATE ESTIMATION

URTDSM Initiative in India and Controlled Islanding using PMU Measurements

Identifying Critical Measurements in the Power System Network

Adaptive Distance Relaying Scheme for Power Swing Tripping Prevention

A Community-Based Partitioning Approach for PMU Placement in Large Systems

CÁTEDRA ENDESA DE LA UNIVERSIDAD DE SEVILLA

Congestion Alleviation using Reactive Power Compensation in Radial Distribution Systems

668 IEEE TRANSACTIONS ON POWER SYSTEMS, VOL. 24, NO. 2, MAY 2009

Optimal PMU Placement for Power System State Estimation with Random Communication Packet Losses

DISTRIBUTION SYSTEM OPTIMISATION

Simulating a Power System

Optimal Capacitor placement in Distribution Systems with Distributed Generators for Voltage Profile improvement by Particle Swarm Optimization

NUMERICAL STABILITY OF ADAPTIVE CONTROL ALGORITHMS

PMU-Based Power System Real-Time Stability Monitoring. Chen-Ching Liu Boeing Distinguished Professor Director, ESI Center

Determination of Fault Location in Shunt Capacitor Bank through Compensated Neutral Current

SINGLE OBJECTIVE RISK- BASED TRANSMISSION EXPANSION

Fine Tuning Of State Estimator Using Phasor Values From Pmu s

TWO BOUNDARY ELEMENT APPROACHES FOR THE COMPRESSIBLE FLUID FLOW AROUND A NON-LIFTING BODY

AN APPROACH TO THE NONLINEAR LOCAL PROBLEMS IN MECHANICAL STRUCTURES

Optimal Placement & sizing of Distributed Generator (DG)

Module 6 : Preventive, Emergency and Restorative Control. Lecture 27 : Normal and Alert State in a Power System. Objectives

Quickest Line Outage Detection and Identification: Measurement Placement and System Partitioning

Dynamic state based on autoregressive model for outgoing line of high voltage stations

TRANSIENT STABILITY IMPROVEMENT OF POWER SYSTEM USING UPFC AND FEEDBACK LINEARIZATION CONTROL

Tropical Optimization Framework for Analytical Hierarchy Process

Performance Evaluation and Review of System Protection Scheme Design with the help of Synchrophasor Measurements

Minimization of Energy Loss using Integrated Evolutionary Approaches

MULTIPHYSICS FINITE ELEMENT MODEL OF A CONTINUOUS THIN METALLIC SHEETS HEATER WITH ROTATING PERMANENT MAGNETS SYSTEM

CAPACITOR PLACEMENT IN UNBALANCED POWER SYSTEMS

Trajectory Sensitivity Analysis as a Means of Performing Dynamic Load Sensitivity Studies in Power System Planning

Mathematical foundations of the methods for multicriterial decision making

OPTIMAL POWER FLOW BASED ON PARTICLE SWARM OPTIMIZATION

Power System Stability and Control. Dr. B. Kalyan Kumar, Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India

Smart Grid State Estimation by Weighted Least Square Estimation

Power Grid State Estimation after a Cyber-Physical Attack under the AC Power Flow Model

Observability of power systems with optimal PMU placement

Grid Event Fingerprints and PMUs

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II : 7 - Transient Stability

Order Reduction of the Dynamic Model of a Linear Weakly Periodic System Part II: Frequency-Dependent Lines

U.P.B. Sci. Bull., Series A, Vol. 74, Iss. 3, 2012 ISSN SCALAR OPERATORS. Mariana ZAMFIR 1, Ioan BACALU 2

Voltage Stability Monitoring using a Modified Thevenin Impedance

Optimal Placement of PMUs in Power Systems Using Mixed Integer Non Linear Programming and Bacterial Foraging Algorithm

Fast Real-Time DC State Estimation in Electric Power Systems Using Belief Propagation

EE 6501 POWER SYSTEMS UNIT I INTRODUCTION

Power Grid Partitioning: Static and Dynamic Approaches

The Necessity for Considering Distribution Systems in Voltage Stability Studies

OBSERVABILITY AND SINGULARITY IN THE CONTEXT OF RÖSSLER MAP

PROPOSED STRATEGY FOR CAPACITOR ALLOCATION IN RADIAL DISTRIBUTION FEEDERS

FAULT DIAGNOSIS IN ANALOG CIRCUITS BASED ON PARAMETRIC DEVIATION OF COMPONENTS COMPUTATION

OPTIMAL CAPACITORS PLACEMENT IN DISTRIBUTION NETWORKS USING GENETIC ALGORITHM: A DIMENSION REDUCING APPROACH

A Scenario-based Transmission Network Expansion Planning in Electricity Markets

Real-Time Wide-Area Dynamic Monitoring Using Characteristic Ellipsoid Method

ANOVA IN THE EDUCATIONAL PROCESS

A Framework for Phasor Measurement Placement in Hybrid State Estimation Via Gauss Newton

A PROPOSED STRATEGY FOR CAPACITOR ALLOCATION IN RADIAL DISTRIBUTION FEEDERS

Optimal Performance Enhancement of Capacitor in Radial Distribution System Using Fuzzy and HSA

POWER DISTRIBUTION SYSTEM OBSERVABILITY WITH SMART METER DATA

Tutorial 2: Modelling Transmission

Metode şi Algoritmi de Planificare (MAP) Curs 2 Introducere în problematica planificării

CAPACITOR PLACEMENT USING FUZZY AND PARTICLE SWARM OPTIMIZATION METHOD FOR MAXIMUM ANNUAL SAVINGS

Bulk Power System Reliability Assessment Considering Protection System Hidden Failures

A Lyapunov Exponent based Method for Online Transient Stability Assessment

Detection of Broken Conductor with Ground Contact Faults in Medium Voltage Power Networks

Optimal Capacitor Placement in Distribution System with Random Variations in Load

CHAPTER 2 LOAD FLOW ANALYSIS FOR RADIAL DISTRIBUTION SYSTEM

Capacitor Placement for Economical Electrical Systems using Ant Colony Search Algorithm

THE METROLOGY OF OPTICAL FIBRE LOSSES

Chapter 8 VOLTAGE STABILITY

Case Study on Fault Analysis Using PMU

POWER system protection at the transmission system level

EFFECTS OF AVERAGING ON SODE MODELS OF DYNAMIC CELL PROCESSES

A Scientific Decision Framework for Supplier Selection under Neutrosophic Moora Environment

Integer Programming Part II

ASSISTED RESEARCH OF THE FOURIER SPECTRUM OF THE ROBOTS WITH MAGNETORHEOLOGICAL DAMPER

ECE 422/522 Power System Operations & Planning/ Power Systems Analysis II 3 Load Modeling

Distributed Power-line Outage Detection Based on Wide Area Measurement System

Dynamic Decomposition for Monitoring and Decision Making in Electric Power Systems

Simultaneous placement of Distributed Generation and D-Statcom in a radial distribution system using Loss Sensitivity Factor

BOOST CIRCUIT CONTROL IN TRANSIENT CONDITIONS

Meta Heuristic Harmony Search Algorithm for Network Reconfiguration and Distributed Generation Allocation

MODELING WITH THE CHAOS GAME (II). A CRITERION TO DEFINE THE RELEVANT TRANSITION PERIODS IN ROMANIA

Criterion Technical Efficiency of Line Distance Relay Protection

Impact of Photovoltaic Generation On The Power System Stability

Towards Morphological Design of GSM Network

Adaptive under frequency load shedding using synchrophasor measurement

STUDY OF THE UTILIZATION AND BENEFITS OF PHASOR MEASUREMENT UNITS FOR LARGE SCALE POWER SYSTEM STATE ESTIMATION. A Thesis YEO JUN YOON

A COMPUTER PROGRAM FOR SHORT CIRCUIT ANALYSIS OF ELECTRIC POWER SYSTEMS

Chapter 2. Planning Criteria. Turaj Amraee. Fall 2012 K.N.Toosi University of Technology

International Journal of Information Technology & Decision Making c World Scientific Publishing Company

ECEN 667 Power System Stability Lecture 20: Oscillations, Small Signal Stability Analysis

SOME APPLICATIONS OF THE HILBERT TRANSFORM

Minimum Sparsity of Unobservable. Power Network Attacks

AS conceived during the 1970 s [1], [2], [3], [4] State

PUMPING STATION SCHEDULING FOR WATER DISTRIBUTION NETWORKS IN EPANET

Transcription:

U.P.B. Sci. Bull., Series C, Vol. 73, Iss. 4, 2011 ISSN 1454-234x OPTIMAL OBSERVABILITY OF PMU'S USING ANALYTIC HIERARCHY PROCESS (AHP) METHOD Sebastian ANGHELESCU 1, Gianfranco CHICCO 2 Lucrarea propune o nouă abordare în vederea plasării unităţilor de măsurare a defazajelor, cu scopul de a monitoriza starea funcţionării sistemului electroenergetic. Monitorizarea rapidă şi în timp real cu ajutorul dispozitivelor phasor measurment unit (PMU) implică o optimizare a plasării acestor dispozitive. Prin plasarea unui numar cât mai mic de unităţi de măsurare a defazajelor aplicaţia devine mai rapidă, acest lucru determină ca intervenţia asupra sistemului să fie una mult mai eficientă. Metoda propusă este exemplificată pe un studiu de caz: un sistem IEEE de 14 noduri, urmând ca aceasta să poată fi testată pentru întreg sistemul electroenergetic din România. The article proposes a new approach for method for the optimal placement of the PMU with the aim of monitoring the working of the power system. Fast and real time monitoring by PMU, involves a optimal placement of phasor measurement units. Through the placement of a minimum number of PMUs, the application becomes faster, which determines a more efficient intervention on the system. The proposed method is exemplified by a case study representing a 14 nodes IEEE system, furthermore this method can be tested for the entire Romanian power system. Keywords: process bus, phasor measurement units, integer linear programming, analytic hierarchy process 1. Introduction Lately, the control-protection system suffered a continuous evolution, which leads to a complete digitalization with the help of the non-conventional transformers or bricks and also by using process bus. These PMUs which are presently physic devices shall be transformed in future into individual application apart from the control and protection system. The method is applicable for both situations of the control-protection system. The method uses three different criteria, whose main aim is to sort these 14 buses by using the analytic hierarchy process. In first step of the proposed a multicriteria approach method, based on three criteria, knowing the pairwise comparation scale: 1 Eng., CN Transelectrica, Electric Transmission Branch, Bucharest, Romania, e-mail: anghelescu.sebastian@transelectrica.ro, emil_seby@yahoo.com 2 Prof. PhD, Electrical Engineering Department, Polytechnic University of Torino

258 Sebastian Anghelescu, Gianfranco Chicco 1. the vulnerability criterion 2. the minimum cost criterion 3. the observability criterion The vulnerability criterion was created with the ETAP soft, which has the transient stability analysis function. With this soft a power network of 14 buses was simulated with the aim of analysing the frequency of each bus and sorting the buses. A fault for each line was simulated in order to find the maximum vulnerability. The frequency of each bus is obtained with the help of the transient stability analysis function. The minimum cost criterion consists of sorting the buses according to the cost of each bus from the power system. It is known that the PMUs have a higher price for those buses that contain more channels which are proportional with the number of branches connected to that bus. The buses, which connect with the generator, have a higher weight according to the observability criterion because these are already observable. Through the analytical hierarchy process method the described pairwise criteria are compared, bearing in mind also the different conditions of these criteria. The result of the AHP method is to sort the buses of the power system having in mind the weight of each criteria. 2. Paper Contents The method is studied on the IEEE 14 buses system and are presented in Fig. 1. The system is made up 5 generators, 5 consumer. Three phase fault is created on all the transmission line, in which the fault simulation is composed for a duration 0.1 sec, beginning fault in 0.02sec and clear fault is realized in 0.12sec, total simulation time is 1 sec. For the first criteria use the simulation, which was realized in ETAP soft version 5.03Z. In which researched frequent at every bus obtained from the Run transient stability function. The maximum frequent at each bus from run transient stability results for every line disturbance showed that for line disturbance on line 13-14.

Optimal observability of PMU's using analytic hierarchy process (AHP) method 259 Fig.1 The IEEE 14 buses system Fig.2. Frequents for each buses for line disturbance 13-14

260 Sebastian Anghelescu, Gianfranco Chicco The 14 bus network can be represented as a 14x14 size square matrix. The diagonal of the matrix represent the buses contained by the proposed system while the others represent: 1 if i=j (that means node or bus) Ai,j 1 if i and j are connected (that means branch between two nodes) 0 if otherwise (none of those) Fig.3 Matrix A of IEEE 14 buses The second criterion is based on the weights nodes of the system. The cost of a PMU varies with the number of channels, so the vector B represents number of channels for each node of the system. B=[2 4 2 5 4 4 3 1 4 2 2 2 3 2] (1) That means the node 4 will have the highest cost of the system, because he will need 5 channels. The third criterion keeps of the nodes connected at the generators. So, C will be a vector make up by 1 if a generator is connected at a node, and 0 otherwise. C=[1 1 1 0 0 1 0 1 0 0 0 0 0 0] (2) It is important to ensure the system during his functionality through place

Optimal observability of PMU's using analytic hierarchy process (AHP) method 261 the PMUs on a set of selected unobservable buses from system thus it uses three different criteria to find the unobservable buses. With those three criteria it is necessary to use a multi - criteria decision making (MCDM) model for selecting a subset of PMUs to be placement in system. For calculating the weights of different criteria uses analytic hierarchy process (AHP). Pair-wise comparisons are used to establish the relative priority of each criterion. The pair-wise comparisons use a scale that ranges from equally preferred to extremely preferred. 1 - Equally preferred Equally to moderately 2 - preferred 3 - Moderately preferred Moderately to strongly 4 - preferred 5 - Strongly preferred Strongly to very strongly 6 - preferred Very strongly 7 - preferred Very to extremely strongly 8 - preferred 9 - Extremely strongly preferred Tabel 1 3 rd root prodeigenvecto Case 1 Case 2 Case 3 of r w1/w1= w1/w2=1/ Case 1 1 5 w1/w3=1/9 0.28 0.063 Case 2 w2/w1= 5 w2/w2=1 w2/w3=1/3 1.18 0.265 Case 3 w3/w1= 9 w3/w2=3 w3/w3=1 3 0.672 Sum 15 4.2 1.4 4.46 SUM*PV 0.94 1.11 0.97 3.029 lamba max 3.029 Cons index 0.014 Fig 4. Pair-wise matrix for weight calculation REMEMBER: Case 1 is "extremely strngly preferred" over case1, as shown in the third row, first column of the matrix. Case 2 is "strongly preferred" over case 1, as shown in the second row, first column of the matrix. Case 3 is moderately preferred over case 2, as shown in the third row, second column of the matrix.

262 Sebastian Anghelescu, Gianfranco Chicco The third-root-of-product values in each row are calculated as follow: Case 1: (1x1/5x1/9)=0.022(1/3) =0.28; Case2: (5x1x1/3)=1.667(1/3) = 1.18; Case3: (9x3x1)=27(1/3) = 3. Each pf the aforementioned third-root-of-product values are then added together to equal (0.28+1.18+3)=4.46 Calculating and checking the Consistency Ratio (CR), which tells the decision-maker how consistent he has been when making the pair-wise comparisons. Consistency index is calculated with the formula CI=(lamba max-n)/(n-1), where n is the number of criteria ; The table of random Index (RI) is shown below: Tabel 2 Random N Index 1 0 2 0 3 0.58 4 0.9 5 1.12 6 1.24 7 1.32 8 1.41 9 1.45 Consistency Ratio (CR)=Consistency Index (CI)/ Random Index (RI) CR=CI/RI=0.014/0.58=0.025 Consistency Ratio 0.025 <0.1, that means the decision maker's pair-wise comparisons are relatively consistent. With those three cases it is necessary to calculate percent for each buses of system as shown in tabel 3. Tabel 3 No. bus Case 1 Case 2 Case 3 1 0.29 0.75 0 2 0.53 0.25 0 3 0.97 0.75 0 4 0.66 0 1 5 0.58 0.25 1 6 0.97 0.25 0 7 0.37 0.5 1 8 0 1 0 9 0.5 0.25 1 10 0.5 0.75 1

Optimal observability of PMU's using analytic hierarchy process (AHP) method 263 11 1 0.75 1 12 0.92 0.75 1 13 0.87 0.5 1 14 0.71 0.75 1 There are two different cases to find the priority vector: a) using unequal weights (uw) to each criterion calculated and b) using equal weights (ew). No.bus Pvuw Pvew 1 0.217 0.346 2 0.099 0.259 3 0.26 0.575 4 0.712 0.553 5 0.774 0.610 6 0.128 0.408 7 0.827 0.623 8 0.265 0.333 9 0.769 0.583 10 0.901 0.750 11 0.933 0.917 12 0.928 0.890 13 0.858 0.789 14 0.915 0.820 Tabel 4 Fig 5. The evolution priority vector unequal and equal weights For start, to ensure the system's complete observability with minimum

264 Sebastian Anghelescu, Gianfranco Chicco numbers of PMUs, it is necessary to regard some few rules: 1. assign a current phasor measurement to each branch incident to a bus provided a PMU; 2. Assign a pseudo-current measurement to each branch connecting two buses known voltage; 3. Assign a pseudo -current measurement to a branch whose current can be inferred by using Kirchhoff 's current law. To find optimal placement of the PMU needs to knowledge the priority vector with unequal weights, and learn the maxim node priority vector. The logic begin with this maxim node priority vector and further needs to ensure the rules. If the node became PMU will be marked with the numeral 3 and otherwise with the numeral 2. So the matrix will modify into like fig. Optimal observability of PMU's using analytic hierarchy process (AHP) method 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 2 0 0 3 0 0 0 0 0 0 0 0 0 2 2 2 3 2 3 0 0 0 0 0 0 0 0 0 3 0 2 3 2 0 0 0 0 0 0 0 0 0 0 4 0 2 3 2 3 0 0 3 0 0 0 0 0 0 5 2 2 0 2 3 0 0 0 0 0 0 0 0 0 6 0 0 0 0 3 2 0 0 0 0 3 2 3 0 7 0 0 0 2 0 0 2 3 3 0 0 0 0 0 8 0 0 0 0 0 0 2 3 0 0 0 0 0 0 9 0 0 0 2 0 0 2 0 3 2 0 0 0 2 10 0 0 0 0 0 0 0 0 3 2 3 0 0 0 11 0 0 0 0 0 2 0 0 0 2 3 0 0 0 12 0 0 0 0 0 2 0 0 0 0 0 2 3 0 13 0 0 0 0 0 2 2 0 0 0 0 2 3 2 14 0 0 0 0 0 0 0 0 3 0 0 0 3 2 Fig 6. The matrix The optimal placement of PMUs is obtained for both cases unequal/equal weights to follow nodes: PMU= [3 5 8 9 11 13 ] (3)

Optimal observability of PMU's using analytic hierarchy process (AHP) method 265 3. Conclusion The proposed method aims at optimizing the number of the PMU placed into a network of 14 buses, so that the system becomes completely observable. This method respects the (N-1) principle, which means that the system is ensured in case that a fault into a PMU appears. The main contribution of this article is the application of the AHP method at the optimization of the number of the PMU in the power system. The advantage of this method is the installation of the PMU on the buses which are considered suitable from the point of view of the applied criteria. The proposed methodology could be successfully applied on any large electrical network. The most interesting aspect of all is that the proposed approach is given by a hierarchical structure evaluation criteria model and determines the global priority weight of each criterion. R E F E R E N C E [1] D. Thukaram, S.R. Kolla, Real-time monitoring of critical nodes with minimal number of Phasor Measurement Units, India Decembre 27-29, 2009 [2] B. Xu, A. Abur, Observability analysis and measurement placement for system with PMU's IEEE Power System Conf. And exposition, New York, vol. 2, USA, 2004, [3] C. Rakpenthai, S. Premrudeepreechacharn, S. Uatrongjit, N.R. Watson, An optimal PMU placement method against measurement loss and branch outage, IEEE Trans. Power Deliv, 2007 [4] J. Zeitsman, Transportation corridor decision-making with multi-attribute utility theory, Int. J. Manage, Decision Making, 2006 [5] J. McGhee, M. Goraj, Smart High Voltage Substation based on 61850 Process Bus and IEEE 1588 Time Synchronization, 2010 IEEE [6] R. Moore, Time synchronization with 1588, PAC World Magazine, Summer 2009 Issue. [7] B. Gou, Generalized Integer Linear Programming Formulation for Optimal PMU Placement Power Systems, IEEE Transactions on, Vol. 23, Issue 3, 2008, Vol. 23. Issue 4, 2008, Page(s): 1812 1820 [8] D. Dua, S. Dambhare, R.K.Gajbhiye, S.A. Soman, Optimal Multistage Scheduling of PMU Placement: An ILP Approach, Power Delivery, IEEE Transactions on, VOL.23, Issue: 4, 2008, Page(s): 1812 1820 [9] C. Rakpenthai, S. Premrudeepreechacharn, S. Uatrongjit, N.R. Watson, An Optimal PMU Placement Method Against Measurement Loss and Branch Outage, Power Delivery, IEEE Transactions on, Vol. 22, Issue 1, 2007, Page(s): 101-107 [10] B.D. Milosevic, M. Begovic, Nondominated Sorting Genetic Algorithm for Optimal Phasor Maesurement Placement, Power Engineering Review, IEEE, Vol. 22, Issue 12, 2002, Page(s): 61 [11] B. Milosevic, M. Begovic, Nondominated sorting genetic algorithm for optimal phasor measurement placement, Power Systems, IEEE Transactions on, Vol. 18, Issue 1, 2003, Page(s): 69-75 [12] N.H. Abbasy, H.M. Ismail, A Unified Approach for the Optimal PMU Location for Power System State Estimation Power Systems, IEEE Transactions on, Vol. 24, Issue 2, 2009, Page(s): 806 813

266 Sebastian Anghelescu, Gianfranco Chicco [13] R. Sodhi, S.C. Srivastava, S.N. Singh, "Multi-criteria decision-making approach for multistage optimal placement of phasor measurement units, Generation, Transmission & Distribution, IET, Vol. 5, Issue 2, 2011, Page(s): 181 190 [14] O.B. Alaba, I. Făgărăşan, R. Dobrescu, S.Şt. Iliescu, "System analysis for e-learning grids, U.P.B. Sci. Bull., Series C, Vol. 71, Iss. 3, 2009 [15] F. Ciauşiu, M. Eremia, "Steady-state stability limit identification for large power systems, U.P.B. Sci. Bull., Series C, Vol. 72, Iss. 1, 2010.