D u m m y Specification sheet Client Project name Order# Type Qty Front view Bottom view Photometric Summary Description The Lumenalpha Clear Small is a high-performance adjustable LED downlight for commercial, residential or hospitality applications. Delivering up to 3000 lumens from a 2.6-inch optical aperture, this highly versatile, fully adjustable downlight offers a choice of outputs, beam angles (including a narrow 10 beam angle for accenting, and an asymmetric distribution for wallwashing) and colour rendering options. Features Optics Control Output (nominal lumens) Colour and colour temperature Optics (nominal distribution) Installation type Warranty Performance Maximum delivered output Maximum delivered intensity Efficacy Colour consistency 700 lm, 1000 lm, 1300 lm, 2000 lm, 3000 lm 2200K, 2700K, 3000K, 3500K, 4000K Narrow spot 10, Narrow 20, Medium 40, Wide 60, True asymmetric wallwash Remodel non-insulated ceiling, New construction non-insulated ceiling, New construction insulated ceiling, New construction insulated ceiling - Chicago plenum rated option (airtight) 5-year limited warranty Up to 2,316 lm Up to 17,103 cd Up to 77 lm/w 2 SDCM Colour rendering CRI 80+/CRI 95+ Rating Lumen maintenance UGR L95 55,000 hrs (Ta 40 C), L70 225,000 hrs (Ta 40 C) < 19 (not applicable to WW optic) 1 / 14
Physical Housing material TIR optics material Reflector material Trim shape Trim finish Adjustability Aluminium Clear polycarbonate (narrow spot and narrow optics) Aluminium (medium and wide optics) Round White, Black, Nickel satin +/- 28 tilt 355 rotation (not available for WW optic) Electrical and control Voltage 120 volts, 277 volts Control On/off control, 0-10V (1% linear or logarithmic), Pro 0-10V (0.1% linear or logarithmic), DALI (0.1% linear or logarithmic), Lutron EcoSystem Enabled dimming, Lumentalk, Phase dimming (consult factory) Environmental Environment Damp location rating (interior applications only) Operating temperature -20 C to 40 C IP Rating IP20 Dimensions NS(10 ) N(20 ) 2 / 14
M(40 ) W(60 ) WW 3 / 14
Photometric information Non-insulated ceiling installation types (RM and NC)1,2 Narrow Spot (nominal 10 ), 4000K Narrow (nominal 20 ), 4000K Medium (nominal 40 ), 4000K 4 / 14
Wide (nominal 60 ), 4000K True asymmetric wallwash, 4000K 1Remove 2 watts per fixture when specifying new construction insulated ceiling installation types (IC and CP). 2Add 3 watts per fixture when specifying Lumentalk. Delivered wattage: +/- 10% tolerance. Preliminary, consult website for latest ies files. Delivered output: +/- 10% tolerance. *Photometric performance is measured in compliance with IESNA LM-79-08. Photometric information Colour rendering options comparison, 3000K 5 / 14
Control Ceiling Requirements Minimum Ceiling Height A - Ceiling cutout: Ø 102 mm B - Maximum ceiling thickness: 25 mm 6 / 14
Installation type Remodel non-insulated ceiling - on/off control Remodel non-insulated ceiling - dimming -MTG-A-VOLTAGE-OUTPUT-COLOUR RENDERING-NO-RM A - Available knockout holes. B - Internal wire gauge: 18 AWG -MTG-A-VOLTAGE-OUTPUT-COLOUR RENDERING-DIMMING-RM A - Available knockout holes. B - Internal wire gauge: 18 AWG New construction non-insulated ceiling - on/off control New construction non-insulated ceiling - dimming -MTG-A-VOLTAGE-OUTPUT-COLOUR RENDERING-NO-NC A - Available knockout holes. B - Internal wire gauge: 18 AWG -MTG-A-VOLTAGE-OUTPUT-COLOUR RENDERING-DIMMING-NC A - Available knockout holes. B - Internal wire gauge: 18 AWG 7 / 14
New construction insulated ceiling, Chicago plenum rated option, airtight -MTG-A-VOLTAGE-OUTPUT-COLOUR RENDERING-CONTROL-IC/CP A - Available knockout holes. B - Internal wire gauge: 18 AWG C-*Available for output and colour rendering combinations -MTG-A-VOLTAGE-OUTPUT-COLOUR RENDERING-CONTROL-IC/CP A - Available knockout holes. B - Internal wire gauge: 18 AWG C - Available for output and colour rendering combinations 8 / 14
Wiring details RM: remodel non-insulated ceiling On/off Control A - Conduit (by others) B - Power Input C - Optional Output D - Conduit fitting (by others) E - Locknut (by others) F - Line (black) G - Neutral (white) H - Ground (green) I - Thermal protector J - Output to luminaire Control (DA1, DA2, PDA1, PDA2, DALI1, DALI2) A - Conduit fitting (by others) B - Conduit (by others) C - Power Input D - Data Input from Control System E - Locknut (by others) F - Neutral (white) G - Line (black) H - Ground (green) I - Data + (purple) J- Data - (grey) K- Output to luminaire L - Thermal protector Control (Daisy Chain Layout) (DA1, DA2, PDA1, PDA2, DALI1, DALI2) A - Conduit (by others) B - Power Output to next luminaire C - Power Input D - Data Output to next luminaire E - Data Input from Control System F - Duplex connector (by others) G - Neutral (white) H- Line (black) I - Ground (green) J - Data - (grey) K- Data + (purple) L - Output to luminaire M- Thermal protector 9 / 14
Wiring details RM: remodel non-insulated ceiling Lumentalk dimming Control (LT) A - Conduit fitting (by others) B - Conduit (by others) C - Power Input D - Locknut (by others) E - Ground (green) F - Neutral (white) G - Line (black) H - Thermal protector I - Output to luminaire Control (Daisy Chain Layout) (LT) A - Conduit fitting (by others) B - Conduit (by others) C - Power Input D - Power Output to next luminaire E - Locknut (by others) F - Ground (green) G - Neutral (white) H - Line (black) I - Thermal protector J - Output to luminaire 10 / 14
Wiring details NC: new construction non-insulated ceiling On/off Control A - Conduit (by others) B - Conduit fitting (by others) C - Locknut (by others) D - Power Input E - Optional Output F - Ground (copper) G - Line (black) H - Neutral (white) I - Thermal protector Control (DA1, DA2, PDA1, PDA2, DALI1, DALI2, EcoSystem )* A - Output to luminaire B - Ground (green) C - Ground (copper) D - Data + (purple E - Data Input from Control System F - Data - (grey) G - Power Input H - Conduit (by others) I- Conduit fitting (by others) J - Locknut (by others) K- Line (black) L - Thermal protector M- Neutral (white) Control (Daisy Chain Layout) (DA1, DA2, PDA1, PDA2, DALI1, DALI2, EcoSystem )* A - Output to luminaire B - Ground (green) C - Ground (copper) D - Data + (purple) E - Data Output to next luminaire F - Data Input from Control System G - Data - (grey) H - Power Input I - Power Output to next luminaire J- Conduit (by others) K- Duplex connector (by others) L - Locknut (by others) M- Line (black) N - Thermal protector O- Neutral (white) *Each Lutron EcoSystem enabled fixture has its own address; for each of the examples shown above, there is one EcoSystem address. Lutron EcoSystem Enabled dimming is not available for 700 lumens or 1000 lumens. 11 / 14
Wiring details IC/CP: new construction insulated ceiling On/off Control A - Conduit (by others) B - Conduit fitting (by others) C - Locknut (by others) D - Line (black) E - Neutral (white) F - Power Input G - Optional Output H - Ground (copper) Control (DA1, DA2, PDA1, PDA2, DALI1, DALI2) A - Conduit (by others) B - Conduit fitting (by others) C - Locknut (by others) D - Line (black) E - Neutral (white) F - Power Input G - Data Input from Control System H - Ground (copper) I - Data - (grey) J - Data + (purple) Control (Daisy Chain Layout) (DA1, DA2, PDA1, PDA2, DALI1, DALI2) A - Conduit (by others B - Duplex connector (by others) C - Locknut (by others) D - Line (black E - Neutral (white) F - Power Input G - Power Output to next luminaire H - Data Input from Control System I - Data Output to next luminaire J - Ground (copper) K - Data - (grey) L - Data + (purple) 12 / 14
How to order 1 2 3 4 5 6 7 8 9 10 11 1. Housing 2. Certification Lumenalpha Downlight Clear Small A UL/cUL 3. Voltage (1) 4. Output (nominal lumens) 120 120 volts 277 277 volts L07 L10 L13 L20 700 lm 1000 lm 1300 lm 2000 lm L30 3000 lm (2) 5. Colour and colour temperature 6. Colour rendering 22K 2200K (3) CR80 CRI 80+ 27K 2700K CR95 CRI 95+ (4) 30K 3000K RCR80 Radiant CRI 80+ (5) 35K 3500K RCR95 Radiant CRI 95+ (4) (5) 40K 4000K 7. Optics (nominal distribution) NS Narrow spot 10 N Narrow 20 M Medium 40 W Wide 60 WW True asymmetric wallwash 8. Trim shape 9. Trim Finish RD Round WH White BK Black NST Nickel satin 10. Control 11. Installation type NO On/off control RM Remodel non-insulated ceiling DA1 0-10V dimming 1% linear NC New construction non-insulated ceiling DA2 0-10V dimming 1% logarithmic IC New construction insulated ceiling (8) PDA1 Pro 0-10V dimming 0.1% linear CP New construction insulated ceiling - Chicago PDA2 Pro 0-10 V dimming 0.1% logarithmic plenum rated option (airtight) (8) DALI1 DALI dimming 0.1% linear DALI2 DALI dimming 0.1% logarithmic ES Lutron EcoSystem Enabled dimming (6) LT Lumentalk (7) PH Phase dimming (consult factory) 13 / 14
Notes: (1) (2) (3) Consult factory for 347 volts. Available for N, M and W distributions only. Available for CR80 only. (4) CR95 and RCR95 available up to 1300 lumens for NS and WW distributions, up to 2000 lumens for N, M and W distributions. (5) Radiant CRI options available for 3000K only. (6) One EcoSystem address per fixture. 1% minimum dimming value. Lutron EcoSystem Enabled dimming available for NC installation type only. Lutron EcoSystem Enabled dimming not available for 700 lumens or 1000 lumens. (7) 1% minimum dimming value. Lumentalk dimming available for RM installation type only. Lumentalk dimming available up to 1000 lumens (CR80, RCR80, CR95 or RCR95), 1300 lumens (CR80 or RCR80). (8) Insulated ceiling available up to 1000 lumens (CR80, RCR80, CR95 or RCR95), 1300 lumens (CR80 or RCR80). 14 / 14