R SANAS Page 1 of 7

Similar documents
Document No: TR 12 Issue No: 1

APPENDIX G EVALUATION OF MEASUREMENT UNCERTAINTY

APPENDIX G ESTIMATION OF UNCERTAINTY OF MEASUREMENT

SAMM POLICY 5 (SP5) POLICY ON MEASUREMENT UNCERTAINTY REQUIREMENTS FOR SAMM TESTING LABORATORIES Issue 2, 28 February 2007 (Amd. 1, 11 August 2014)

EA 4/02. Expression of the Uncertainty of Measurement in Calibration. Publication Reference

OA03 UNCERTAINTY OF MEASUREMENT IN CHEMICAL TESTING IN ACCORDANCE WITH THE STANDARD SIST EN ISO/IEC Table of contents

WGFF Guidelines for CMC Uncertainty and Calibration Report Uncertainty

Essentials of expressing measurement uncertainty

Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO Second edition

A2LA. G118: Guidance for Defining the Scope of Accreditation for Calibration Laboratories

Joint Committee for Traceability in Laboratory Medicine Terminology. R. Wielgosz and S. Maniguet

Introduction to the evaluation of uncertainty

HOW TO EXPRESS THE RELIABILITY OF MEASUREMENT RESULTS. The role of metrological traceability and measurement uncertainty-

Uncertainty of Measurement A Concept

Uncertainty Propagation for Force Calibration Systems

Calibration Traceability Guidelines

Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO Second edition

Certificate of Accreditation to ISO/IEC 17025:2005

JAB NOTE4. ESTIMATION OF MEASUREMENT UNCERTAINTY (Electrical Testing / High Power Testing) Japan Accreditation Board (JAB)

2.1. Accuracy, n- how close the indication of the thermometer is to the true value.

Revision of the Guide to the expression of uncertainty in measurement impact on national metrology institutes and industry

Part 5: Total stations

y, x k estimates of Y, X k.

A guide to expression of uncertainty of measurements QA4EO-QAEO-GEN-DQK-006

CCM short note on the dissemination process after the proposed redefinition of the kilogram

EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

A61-02 CALA Guidance on Traceability Revision 1.2 October 15, 2012

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

GUIDE Uncertainty of measurement Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

Evaluation. of the Uncertainty. of Measurement. In Calibration

Determination of particle size distribution Single particle light interaction methods. Part 4:

H1: Metrological support. Milena Horvat, Polona Vreča, Tea Zuliani, Radojko Jaćimović, Radmila Milačič

Measurement Uncertainty in Mechanical Testing

Technical Protocol of the CIPM Key Comparison CCAUV.V-K5

Practical Interpretation of Metrological Traceability on Gauge Block as to VIM 3

UNCERTAINTY ANALYSIS FOR LABORATORY ACCREDITATION. Peter B. Crisp. Fluke Precision Measurement Ltd, 52 Hurricane Way, Norwich, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

ISO INTERNATIONAL STANDARD

Final Report EUROMET PROJECT 818 CALIBRATION FACTOR OF THERMISTOR MOUNTS. Jan P.M. de Vreede

Morehouse. Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA PH: web: sales:

CERTIFICATE OF CALIBRATION

Metallic materials Brinell hardness test. Part 3: Calibration of reference blocks

Maha Ireland Ltd. 629 Jordanstown Avenue, Greenogue Business Park, Rathcoole, Co. Dublin. Calibration Laboratory Registration number: 287C

IS INTERNATIONAL STANDARD. Natural gas - Guidelines to traceability in analysis

ISO/TS TECHNICAL SPECIFICATION. Water quality Guidance on analytical quality control for chemical and physicochemical water analysis

Guide to the Expression of Uncertainty in Measurement (GUM) and its supplemental guides

Guidelines on the Calibration of Static Torque Measuring Devices

Metrology and Environment

Comparison of measurement uncertainty budgets for calibration of sound calibrators: Euromet project 576

ISO Water quality Measurement of polonium 210 activity concentration in water by alpha spectrometry

Vocabulary of Metrology

Comparability and Traceability Point of view from a metrological institute

Technical Protocol of the Bilateral Comparison in Primary Angular Vibration Calibration CCAUV.V-S1

This document is a preview generated by EVS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ADVANCED TECHNOLOGY SERVICES HMA 1800 Honda Drive Lincoln, AL Lasheila Hayes Phone:

Mason Technology Ltd

Guidelines on the Calibration of Automatic Instruments for Weighing Road Vehicles in Motion and Measuring Axle Loads AWICal WIM Guide May 2018

JCGM 100:2008 GUM 1995 with minor corrections. Evaluation of measurement data Guide to the expression of uncertainty in measurement

Measurement & Uncertainty - Basic concept and its application

Mason Technology Ltd

OIML G GUIDE. Edition 2009 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Uncertainty of Measurement

EA-10/14. EA Guidelines on the Calibration of Static Torque Measuring Devices. Publication Reference PURPOSE

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

AFRIMETS. Supplementary Comparison Programme. Calibration of Gauge Blocks. by Mechanical Comparison Method AFRIMETS.L S3.

The Fundamentals of Moisture Calibration

Recent Developments in Standards for Measurement Uncertainty and Traceability (An Overview of ISO and US Uncertainty Activities) CMM Seminar

This document is a preview generated by EVS

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Metallic materials Knoop hardness test Part 1: Test method

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

ISO INTERNATIONAL STANDARD. Geographic information Metadata Part 2: Extensions for imagery and gridded data

TITLE OF THE CD (English): New OIML Document

Calibration and verification: Two procedures having comparable objectives and results

Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results

Provläsningsexemplar / Preview. First edition

A Unified Approach to Uncertainty for Quality Improvement

ISO INTERNATIONAL STANDARD. Reference radiation fields Simulated workplace neutron fields Part 1: Characteristics and methods of production

Unit 4. Statistics, Detection Limits and Uncertainty. Experts Teaching from Practical Experience

METHODS FOR CERTIFYING MEASUREMENT EQUIPMENT. Scott Crone

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

EXPRESSION DE L INCERTITUDE DE MESURE EN ETALONNAGE

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ALLOMETRICS, INC Bayport Blvd. Seabrook, TX Terry Baldwin Phone: CALIBRATION

Precision estimated by series of analysis ISO and Approach Duplicate Approach

New Thermometer Guidance Document from AASHTO Accreditation Program. Maria Knake Asphalt Binder ETG Meeting May 10, 2018

GNSS CORS Calibration and Testing

Can there be a metrology for psychometricians?

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z ALPHAGAGE th Avenue Rockford, IL James Hoard Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

ISO INTERNATIONAL STANDARD

This document is a preview generated by EVS

POWER QUALITY MEASUREMENT PROCEDURE. Version 4 October Power-Quality-Oct-2009-Version-4.doc Page 1 / 12

Technical Note A Quantification and NIST Traceability of Micromatter Thin Film Standards for XRF Analysis. Version March 16, 2017

Final Report on APMP.M.M-K4.1 - Bilateral Comparison of 1 kg Stainless Steel Mass Standards between KRISS and A*STAR

Measurement & Uncertainty - Concept and its application

Report on Key Comparison COOMET.AUV.A-K5: Pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 khz

Transcription:

ESTIMATION OF THE UNCERTAINTY OF MEASUREMENT BY CALIBRATION LABORATORIES AND SPECIFICATION OF CALIBRATION AND MEASUREMENT CAPABILITY ON SCHEDULES OF ACCREDITATION Approved By: Chief Executive Officer: Ron Josias Senior Manager: Mpho Phaloane Revised By: Field Manager: Neville Tayler Date of Approval: 2013-08-14 Date of Implementation: 2013-08-14 SANAS Page 1 of 7

CONTENTS: 1. Purpose and Scope...3 2. References...3 3. Definitions...3 4. Abbreviations...4 5. Uncertainty of Measurement...5 6. Calibration and Measurement Capability...6 ADDENDUM 1: Amendment Record...7 SANAS Page 2 of 7

1. Purpose and Scope This document is not intended to be a guidance document on the estimation of measurement uncertainty, a number of which are already freely available on the internet, but rather to define the policy for the estimation of uncertainty of measurement by calibration laboratories, and to define the determination and specification of the Calibration and Measurement Capability. Where appropriate additional guidance on the interpretation of certain requirements has been provided. This Regulatory document is applicable to all accredited calibration laboratories, and testing laboratories performing their own calibration. 2. References [1] Act 18 of 2008 Measurement Units and Measurement Standards Act [2] ISO/IEC 17025: 2005 General requirements for the competence of testing and calibration laboratories, 2005 [3] JCGM 200 : 2008 International Vocabulary of Metrology - Basic and General concepts and associated terms (VIM) [4] GUM 1993 Guide to the Expression of Uncertainty of Measurement, first edition, 1993, corrected and reprinted 1995, International Organization for Standardization (Geneva, Switzerland). [5] EAL-R2 Expression of the Uncertainty of Measurement in Calibration, European co-operation for Accreditation, December 1999. (previously EA-04/02) [6] Cook Book Assessment of Uncertainties of measurement : for Calibration and testing laboratories, 2 nd Ed RR Cook, 2002 [7] ISO 3534-1:1993 Statistics Vocabulary and symbols Part1 Probability and statistical terms, International Organization for Standardization. [8] M3003 Ed 1 1997 UKAS The Expression of Uncertainty and Confidence in Measurement. [9] ILAC-14/01/2013 ILAC Policy for Uncertainty in Calibration 3. Definitions Best existing device The term best existing device is understood as a device to be calibrated that is commercially or otherwise available for customers, even if it has a special performance (stability) or has a long history of calibration. Calibration and Measurement Capability A CMC is a calibration and measurement capability available to customers under normal conditions: a) as described in the laboratory s scope of accreditation granted by a signatory to the ILAC Arrangement; or b) as published in the BIPM key comparison database (KCDB) of the CIPM MRA. Combined standard uncertainty Standard uncertainty of the result of a measurement when that result is obtained from the values of a number of other quantities, equal to the positive square root of a sum of terms being the SANAS Page 3 of 7

variances or co-variances of these other quantities weighted according to how the measurement result varies with changes in these quantities. [4] Correlation The relationship between two or several random variables within a distribution of two or more random variables. [7] Coverage Factor. Numerical factor used as a multiplier of the combined standard uncertainty in order to obtain an expanded uncertainty. Note that a coverage factor, k, is typically in the range 2 to 3. Experimental Standard Deviation of the Mean The Experimental Standard Deviation of the Mean (ESDM) is an estimate of the standard deviation of the means from repeated sets of measurements. [3 Def 3.8] and [6 Appendix ii]. Expanded uncertainty Quantity defining an interval about the result of a measurement that may be expected to encompass a large fraction of the distribution of values that could with a certain level of confidence be attributed to the measurand. [4] Repeatability (of results of measurements) Closeness of the agreement between the results of successive measurements of the same measurand carried out under the same conditions. [3] Repeatability (of a measuring instrument) Ability of a measuring instrument to provide closely similar indications or repeated applications of the same measurand under the same conditions of measurement. [3] Reproducibility condition of measurement Condition of measurement, out of a set of conditions that includes different locations, operators, measuring systems, and replicate measurements on the same or similar objects [3] Standard Uncertainty Uncertainty of the result of a measurement expressed as a standard deviation. [4] Type A evaluation (of uncertainty). Method of evaluation of uncertainty by the statistical analysis of series of observations. [4] Type B evaluation (of uncertainty). Method of evaluation of uncertainty by means other than the statistical analysis of series of observations. [4] Uncertainty of Measurement Parameter, associated with the result of a measurement that characterises the dispersion of the values that could with a certain level of confidence be attributed to the measurand. [3 def 3.9] 4. Abbreviations ESDM BIPM CMC NMI RSS SANAS UoM UUT Experimental Standard Deviation of the Mean International Bureau of Weights and Measures Calibration and Measurement Capability National Metrology Institute Root Sum Squared South African National Accreditation System Uncertainty of Measurement Unit under Test SANAS Page 4 of 7

5. Uncertainty of Measurement 5.1 SANAS requires that all calibration laboratories and testing laboratories performing their own calibrations shall have and apply a procedure for the estimation of the uncertainty of measurement. [2 clause 5.4.6] 5.2 The measurement units and measurement standards act 18 of 2006 requires that traceability for any legal purpose be traceable to one or more national standards, through an unbroken chain of comparisons stating appropriate uncertainties of measurement. [1] 5.3 The estimation of the uncertainty of measurement shall include the identification of, and analysis of all known components of importance. The degree of rigour applied to the estimation of the measurement uncertainty should be appropriate to the intended purpose of the calibration based on the customer requirements. [2 clause 5.4.6] 5.4 In general laboratories shall use the guidelines as specified in the GUM [4] as the basis for the preparation of their procedure on the estimation of the uncertainty of measurement. These principles are expanded on in various interpretation documents such as EAL-R2 Expression of the Uncertainty of Measurement in Calibration [5], Ron Cook s book Assessment of Uncertainties of Measurement for calibration & testing laboratories (recommended) 2 nd Ed, 2002 [6] and M3003 The expression of Uncertainty and Confidence in Measurement [8]. In exceptional cases other internationally recognized methodologies may be applied. 5.5 It is recommended that the data relevant to the determination of the uncertainty of measurement, including quantities, standard uncertainties, and sensitivity coefficients be available in clear, unambiguous format, such as in a spreadsheet, or tabular format. 5.6 Laboratories may elect to perform uncertainty of measurement calculations using computerised spreadsheets, in such cases the laboratory shall ensure that the spreadsheets are suitably documented, validated and protected against unauthorised changes. [2 clause 5.4.7] 5.7 Certain electronic calculators used in the Statistical mode are prone to errors due to rounding; this may become evident in the calculation of standard deviation, when the calculation returns an incorrect result. Appropriate methods shall be applied to circumvent these calculation errors. [8 Appendix L] 5.8 SANAS approved technical signatories shall be competent to evaluate and interpret the results of UoM spreadsheet calculators to confirm their correctness. 5.9 When input quantities are not independent, and are correlated, such as is the case when standard resistors are connected in series, or several Masspieces are used to produce a combined mass, then the combined uncertainty shall be the algebraic sum of the uncertainties unless the laboratory can produce evidence of the degree of correlation, the uncertainties may then be combined using the correlation coefficient. 5.10 If an uncertainty assessment involves a single Type A evaluation and the number of readings, n, is greater than 2 (n 3) and the combined standard uncertainty is more than twice (x2) the type A uncertainty, or the number of readings, n, is greater than 4 (n 5) and the combined standard uncertainty is greater than 1,5 times (x1,5) the Type A uncertainty, then k = 2 will provide a coverage probability of approximately 95% and thus there is no need to apply the Welch- Satterthwaite equation to determine the effective degrees of freedom v eff, and the coverage factor k. [8 Section 7.3] and [4 Annex G] 5.11 When conditions are not repeatable, the inappropriate use of ESDM as a measure of the Type A uncertainty may result in an underestimation of measurement uncertainty, and should therefore be used after due consideration. For example, when a torque wrench is used in practice, the device is not used repeatedly to torque the same bolt, and the torque applied to a bolt is the SANAS Page 5 of 7

result of a single measurement, and not the mean of a set of measurements. The same principle is applicable to other types of measurement tools used in industry. In addition, in instances where the number of repeated measurements is small, the reliability of a Type A evaluation has to be considered, and the option of using other means of evaluating the standard uncertainty should be considered. [5 Section 3.2] 5.12 The uncertainty of measurement shall not be reported to more than 2 significant digits. When calculating the CMC the uncertainty of measurement shall always be rounded up, unless the rounding reduces the uncertainty by less than 5%. [9 Section 6.3] and [8 Section 8] 6. Calibration and Measurement Capability 6.1 The Calibration and Measurement Capability (CMC) is represented on the schedule of accreditation issued by SANAS. The CMC is expressed in terms of: a) measurand or reference material; b) calibration/measurement, method/procedure, and or type of instrument to be calibrated or measured; c) measurement range and additional parameters where applicable, e.g. frequency of applied voltage; and d) uncertainty of measurement; [9] 6.2 The uncertainty of Measurement represented as part of the CMC represents the smallest uncertainty of measurement that a laboratory can claim for any measurement or calibration performed and reported in a certificate which makes reference to accreditation and/or includes the accreditation symbol. 6.3 The CMC uncertainty is stated as an expanded uncertainty with a coverage probability of approximately 95%. 6.4 When the uncertainty of measurement is dependent upon an additional parameter, e.g. frequency, the additional parameter shall be stated together with the physical quantity in question and the specified CMC shall take cognisance of this additional parameter, this may be accomplished by specifying the CMC as a function of these parameters. [5 Appendix A] 6.5 All components contributing significantly to the uncertainty of measurement including the drift between subsequent calibrations of the measurement standard shall be taken into account when evaluating the measurement capability. 6.6 The determination of the uncertainty of measurement, for the purposes of the establishment of the CMC uncertainty shall include at least the uncertainty contribution from a best existing device to be calibrated. [9] 6.7 When the accreditation schedule includes a range of measurement for a specified parameter, the laboratory shall be capable of achieving the CMC uncertainty throughout the specified range. In instances where this is not possible sub-ranges, single values, or a matrix shall be introduced with separate CMC s specified for the individual sub-ranges, or single values or matrix entries. 6.8 Applicant laboratories, and laboratories wishing to have changes made to their laboratories CMC s shall submit an Uncertainty of Measurement calculation in support of the requested CMC. 6.9 Laboratories who fail to demonstrate the ability to produce acceptable measurement results as evidenced through proficiency testing and the National audit program may at the discretion of SANAS have their measurement capability increased to a level, which would result in an En value of less than 0,9 (absolute). SANAS Page 6 of 7

ADDENDUM 1: Amendment Record Proposed By: Section Change CEO Page 1 Changed to new logo & Front page Rev 03 FM Title Page Minor change to the Title FM Page 2 Updated references, included ILAC 14, included Act 18 FM Page 3 Added definitions for best existing device & CMC, delete definition for Measurement capability, added definition for reproducibility FM Page 6 5.1.2 amended to bring in line with ILAC P14 requirement FM Page 6 6.1 amended to be in line with ILAC P14 FM Page 6 References to MC changed to CMC SANAS Page 7 of 7