CERTIFICATE OF CALIBRATION

Similar documents
CERTIFICATE OF CALIBRATION

Comparison of measurement uncertainty budgets for calibration of sound calibrators: Euromet project 576

PRODUCT DATA. Sound Intensity Calibrator Type 3541-A. Uses and Features

MAC Aura XB Acoustic Test Report

The information included in the following report presents the results of sound pressure and sound power testing.

CALIBRATION CERTIFICATE # 503

Certificate of Calibration Sound Level Calibrator

Uncertainties associated with the use of a sound level meter

Guidelines on the Calibration of Automatic Instruments for Weighing Road Vehicles in Motion and Measuring Axle Loads AWICal WIM Guide May 2018

Product Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Mason Technology Ltd

CERTIFICATE OF ACCREDITATION

Mason Technology Ltd

RIVERBANK ACOUSTICAL LABORATORIES

CERTIFICATE OF CALIBRATION

Document No: TR 12 Issue No: 1

APPENDIX G EVALUATION OF MEASUREMENT UNCERTAINTY

Determination of sound absorption coefficient in impedance tubes according to ISO (2 appendices)

OA03 UNCERTAINTY OF MEASUREMENT IN CHEMICAL TESTING IN ACCORDANCE WITH THE STANDARD SIST EN ISO/IEC Table of contents

A L I O N Technical Center. Test Report. Port Coquitlam, British Columbia, Canada

A L I O N Technical Center. Test Report

The Fundamentals of Moisture Calibration

APPENDIX G ESTIMATION OF UNCERTAINTY OF MEASUREMENT

CERTIFICATE OF CALIBRATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES

Technical Protocol of the CIPM Key Comparison CCAUV.V-K5

Measurement of sound absorption coefficient for Fraster felt SpaceCover

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 7MM TESTED WITH A 20MM AIR GAP IN A REVERBERATION ROOM.

Yalıtım Kontrol Koruma. Insulation Control Protection

RIVERBANK ACOUSTICAL LABORATORIES

Test Report EN (2008)

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 24MM TESTED WITH NO AIR GAP MEASURED IN A REVERBERATION ROOM.

DELTA Test Report. Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm

Static pressure and temperature coefficients of working standard microphones

Part 2: Methods for special reverberation test rooms

Report on Key Comparison COOMET.AUV.A-K5: Pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 khz

SAMM POLICY 5 (SP5) POLICY ON MEASUREMENT UNCERTAINTY REQUIREMENTS FOR SAMM TESTING LABORATORIES Issue 2, 28 February 2007 (Amd. 1, 11 August 2014)

Calibration, traceability, uncertainty and comparing measurement results. Workshop 16 March 2015 VSL, Delft The Netherlands

ISO 3741 INTERNATIONAL STANDARD

FINAL REPORT ON KEY COMPARISON APMP.AUV.A-K3

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method

DELTA Test Report. Measurement of Sound Absorption for AqFlex ON, one Sample as a discrete Object. Performed for Flex Acoustics

Technical Report. Project. The Laboratory Determination of The Random Incidence sound Absorption Coefficient of VertiQ Panels.

Tel: Fax: PRODUCT INFORMATION

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL

Determination of particle size distribution Single particle light interaction methods. Part 4:

Maha Ireland Ltd. 629 Jordanstown Avenue, Greenogue Business Park, Rathcoole, Co. Dublin. Calibration Laboratory Registration number: 287C

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

R & D AKUSTIKA * SIA. Test Report of laboratory Sound Insulation measurements Nr. 569 / 2011 AL 8.4. CUSTOMER: AEROC AS (Estonia)

Consultancy Report Ref: 9383-R01

Calibration and verification: Two procedures having comparable objectives and results

M. A. Navacerrada, C. Díaz, A. Pedrero and L. Iglesias

EDITION 1 OCTOBER 1997 EA-10/09 PAGE 1 OF

Technical Protocol of the Bilateral Comparison in Primary Angular Vibration Calibration CCAUV.V-S1

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL

Part 5: Total stations

VOC TEST REPORT CDPH

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CERTIFICATE OF CALIBRATION

R SANAS Page 1 of 7

VOC TEST REPORT CDPH

CALIBRATION REPORT FOR THERMOHYDROMETER

2.1. Accuracy, n- how close the indication of the thermometer is to the true value.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6266/ARL-SA6274 Revision 0 ARL

ISO INTERNATIONAL STANDARD

5730A High Performance Multifunction Calibrator. Extended specifications

SAMPLE. Accuracy Calibration Certificate. Mettler Toledo 1900 Polaris Parkway Contact: Instrument Type: EURAMET cg-18 v. 4.0 Sample ACC WI v.1.

Insertion Loss Analysis of the Acoustic Panels with Composite Construction

Certificate of Accreditation

Uncertainty Propagation for Force Calibration Systems

List of Legislative Regulations Dealing with Nuclear Energy and Ionizing Radiation and Related Documents

792A AC/DC Transfer Standard

Acoustic test report AU01+N01

Accuracy Calibration Certificate

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Vocabulary of Metrology

Measurement of Acoustic Properties of light weight concrete SL-Deck

An examination of some aspects of the use of ISO 140 Part 4 and 7 in field measurements.

EA-10/14. EA Guidelines on the Calibration of Static Torque Measuring Devices. Publication Reference PURPOSE

Implementation of ISO/IEC in a low level liquid s cintillation tritium laboratory

Understanding uncertainties associated with the 5128A RHapid-Cal Humidity Generator

Guidelines on the Calibration of Static Torque Measuring Devices

Acknowledgment of Aramco Asia. Supplier Code of Conduct

Metallic materials Brinell hardness test. Part 3: Calibration of reference blocks

Page 1 of 10 pages Appendix, 5 pages Report no.: P Glostrup, October 12th 2012 Project: Claimant:

Certificate of Accreditation

SAMPLE. Accuracy Calibration Certificate. Instrument Type: EURAMET cg-18 v. 4.0 Sample ACC ISO17025 WI v.1.0

Testing Procedure: AS ISO

ACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES

SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY CO., LTD

CERTIFICATE OF ACCREDITATION

COMPARISON OF THE METHODS TO CALIBRATE THE DIFFUSE FIELD SENSITIVITY OF LABORATORY STAND- ARD MICROPHONE

MEASUREMENT UNCERTAINTY PREPARED FOR ENAO ASSESSOR CALIBRATION COURSE OCTOBER/NOVEMBER Prepared by MJ Mc Nerney for ENAO Assessor Calibration

MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE

Transcription:

Page 1 of 10 CALIBRATION OF Sound Level Meter: Brüel & Kjær Type 3050-A-040 No: 3050-100751 Id: - Microphone: Brüel & Kjær Type 4189 No: 2621142 Preamplifier: Brüel & Kjær Type 2669 No: 2679073 Supplied Calibrator: None Software version: LabShop 17.1.0.22 Pattern Approval: PENDING Instruction manual: BE1631 CUSTOMER Brüel & Kjær Sound & Vibration Measurement A/S Skodsborgvej 307 DK-2850 Nærum Denmark CALIBRATION CONDITIONS Preconditioning: Environment conditions: SPECIFICATIONS PROCEDURE 4 hours at 23 C ± 3 C See actual values in Environmental conditions sections. The Sound Level Meter Brüel & Kjær Type 3050-A-040 has been calibrated in accordance with the requirements as specified in IEC61672-1:2002 class 1. Procedures from IEC 61672-3:2006 were used to perform the periodic tests. The accreditation assures the traceability to the international units system SI. The measurements have been performed with the assistance of Brüel & Kjær Sound Level Meter Calibration System 3630 with application software type 7763 (version 4.7 - DB: 4.70) by using procedure LAN-XI 4189. RESULTS Calibration Mode: Calibration as received. The reported expanded uncertainty is based on the standard uncertainty multiplied by a coverage factor k = 2 providing a level of confidence of approximately 95 %. The uncertainty evaluation has been carried out in accordance with EA-4/02 from elements originating from the standards, calibration method, effect of environmental conditions and any short time contribution from the device under calibration. Date of calibration: 2012-12-20 Date of issue: 2012-12-20 Jonas Johannessen Calibration Technician Henning Ploug Approved Signatory Reproduction of the complete certificate is allowed. Parts of the certificate may only be reproduced after written permission.

Page 2 of 10 1. Calibration Note n/a 2. Summary 4.1. Preliminary inspection Passed 4.2. Environmental conditions, Prior to calibration Passed 4.3. Channel information Passed 4.4. Reference information Passed 4.5. Indication at the calibration check frequency Passed 4.6. Self-generated noise, Microphone installed Passed 4.7. Acoustical signal tests of a frequency weighting, C weighting Passed 4.8. Self-generated noise, Electrical Passed 4.9. Electrical signal tests of frequency weightings, A weighting Passed 4.10. Electrical signal tests of frequency weightings, C weighting Passed 4.11. Electrical signal tests of frequency weightings, Z weighting Passed 4.12. Frequency and time weightings at 1 khz Passed 4.13. Level linearity on the reference level range, Upper Passed 4.14. Level linearity on the reference level range, Lower Passed 4.15. Toneburst response, Time-weighting Fast Passed 4.16. Toneburst response, Time-weighting Slow Passed 4.17. Toneburst response, Leq Passed 4.18. Peak C sound level, 8 khz Passed 4.19. Peak C sound level, 500 Hz Passed 4.20. Overload indication Passed 4.21. Environmental conditions, Following calibration Passed The sound level meter submitted for periodic testing successfully completed the class 1 tests of IEC 61672-3:2006, for the environmental conditions under which the tests were performed. However, no general statement or conclusion can be made about conformance of the sound level meter to the full requirements of IEC 61672-1:2002 because evidence was not publicly available, from an independent testing organization responsible pattern approvals, to demonstrate that the model of sound level meter fully conformed to the requirements in IEC 61672-1:2002 and because the periodic test of IEC 61672-3:2006 cover only a limited subset of the specifications in IEC 61672-1:2002.

Page 3 of 10 3. Instruments Instrument Inventory No. Generator Brüel & Kjær, Type 3560 123560012 Voltmeter Agilent, Type 34970A 142101010 AmplifierDivider Brüel & Kjær, Type 3111 123111002 Adaptor Brüel & Kjær, Type WA-0302-B 15 pf 150503007 Calibrator Brüel & Kjær, Type 4226 124226016

Page 4 of 10 4. Measurements 4.1. Preliminary inspection Visually inspect instrument, and operate all relevant controls. (section 5) Routine Passed 4.2. Environmental conditions, Prior to calibration Actual environmental conditions prior to calibration. (section 7) [Deg C/ kpa / %RH] Air temperature 23.00 Air pressure 102.49 Relative humidity 48.00 4.3. Channel information Number of channel being calibrated. Signal number 1 Channel information 0 4.4. Reference information Information about reference range, level and channel. (section 19.h + 19.m) Reference sound pressure level Value [db] 94 Reference level range 135 Channel number 0 4.5. Indication at the calibration check frequency Measure and adjust sound level meter using the supplied calibrator. (section 9 + 19.m) Initial indication (in-house calibrator) Calibration check frequency (in-house calibrator) Adjusted indication (in-house calibrator) Uncertainty [db / Hz] [db / Hz] 93.39 0.20 1000.00 1.00 94.14 0.20

Page 5 of 10 4.6. Self-generated noise, Microphone installed Self-generated noise measured with microphone submitted for periodic testing. Averaging time is 30 seconds. An anechoic chamber is used to isolate environmental noise. (section 10.1) Max Deviation Uncertainty [db] [db] [db] [db] A weighted 17.20 15.90-1.30 1.00 Monitor Level 20.20 11.40-8.80 1.00 4.7. Acoustical signal tests of a frequency weighting, C weighting Frequency weightings measured acoustically with a calibrated multi-frequency sound calibrator. Averaging time is 10 seconds, and the result is the average of 2 measurements. (section 11) 1000Hz, Ref. (1st) 1000Hz, Ref. (2nd) 1000Hz, Ref. (Average) Coupler Pressure Lc Mic. Correction C4226 Body Influence Expected Corr. Accept - Accept + Deviation Uncertainty [db] [db] [db] [db] 94.22 0.10 0.00 94.12 94.13 94.13-1.1 1.1 0.01 0.20 94.22 0.10 0.00 94.12 94.13 94.13-1.1 1.1 0.01 0.20 94.22 0.10 0.00 94.12 94.13 94.13-1.1 1.1 0.01 0.20 125.89Hz (1st) 94.21 0.00 0.00 94.02 94.07 94.07-1.5 1.5 0.05 0.20 125.89Hz (2nd) 94.21 0.00 0.00 94.02 94.07 94.07-1.5 1.5 0.05 0.20 125.89Hz (Average) 94.21 0.00 0.00 94.02 94.07 94.07-1.5 1.5 0.05 0.20 3981.1Hz (1st) 94.12 0.90 0.00 92.43 92.35 92.35-1.6 1.6-0.08 0.30 3981.1Hz (2nd) 94.12 0.90 0.00 92.43 92.35 92.35-1.6 1.6-0.08 0.30 3981.1Hz (Average) 94.12 0.90 0.00 92.43 92.35 92.35-1.6 1.6-0.08 0.30 7943.3Hz (1st) 93.71 2.80 0.00 87.92 87.48 87.48-3.1 2.1-0.44 0.40 7943.3Hz (2nd) 93.71 2.80 0.00 87.92 87.48 87.48-3.1 2.1-0.44 0.40 7943.3Hz (Average) 93.71 2.80 0.00 87.92 87.48 87.48-3.1 2.1-0.44 0.40 4.8. Self-generated noise, Electrical Self-generated noise measured in most sensitive range, with electrical substitution for microphone, according to manufactures specifications. Exceedance of the measured level above the corresponding level given in the instruction manual does not, by itself, mean that the performance of the sound level meter is no longer acceptable for many practical applications. (section 10.2) Max Uncertainty [db] [db] [db] A weighted 13.20 9.84 0.30 C weighted 20.60 12.06 0.30 Z weighted 20.60 15.57 0.30

Page 6 of 10 4.9. Electrical signal tests of frequency weightings, A weighting Frequency response measured with electrical signal relative to level at 1 khz in reference range. (section 12) Input Level Expected El.+Acous. Resp. Body Influence Corr. Accept - Accept + Deviation Uncertainty [dbv] [db] [db] [db] 1000Hz, Ref. -30.23 90.00 90.00 0.00 0.00 90.00-1.1 1.1 0.00 0.12 63.096Hz -4.03 90.00 90.04 0.00 0.00 90.04-1.5 1.5 0.04 0.12 125.89Hz -14.13 90.00 89.99 0.00 0.00 89.99-1.5 1.5-0.01 0.12 251.19Hz -21.63 90.00 89.95 0.00 0.00 89.95-1.4 1.4-0.05 0.12 501.19Hz -27.03 90.00 89.97 0.00 0.00 89.97-1.4 1.4-0.03 0.12 1995.3Hz -31.43 90.00 90.00 0.00 0.00 90.00-1.6 1.6 0.00 0.12 3981.1Hz -31.23 90.00 89.95 0.00 0.00 89.95-1.6 1.6-0.05 0.12 7943.3Hz -29.13 90.00 89.96 0.00 0.00 89.96-3.1 2.1-0.04 0.12 15849Hz -23.63 90.00 89.98 0.00 0.00 89.98-17.0 3.5-0.02 0.12 4.10. Electrical signal tests of frequency weightings, C weighting Frequency response measured with electrical signal relative to level at 1 khz in reference range. (section 12) Input Level Expected El.+Acous. Resp. Body Influence Corr. Accept - Accept + Deviation Uncertainty [dbv] [db] [db] [db] 1000Hz, Ref. -30.23 90.00 90.00 0.00 0.00 90.00-1.1 1.1 0.00 0.12 63.096Hz -29.43 90.00 90.00 0.00 0.00 90.00-1.5 1.5 0.00 0.12 125.89Hz -30.03 90.00 90.03 0.00 0.00 90.03-1.5 1.5 0.03 0.12 251.19Hz -30.23 90.00 89.99 0.00 0.00 89.99-1.4 1.4-0.01 0.12 501.19Hz -30.23 90.00 90.02 0.00 0.00 90.02-1.4 1.4 0.02 0.12 1995.3Hz -30.03 90.00 90.03 0.00 0.00 90.03-1.6 1.6 0.03 0.12 3981.1Hz -29.43 90.00 89.96 0.00 0.00 89.96-1.6 1.6-0.04 0.12 7943.3Hz -27.23 90.00 89.96 0.00 0.00 89.96-3.1 2.1-0.04 0.12 15849Hz -21.73 90.00 89.95 0.00 0.00 89.95-17.0 3.5-0.05 0.12 4.11. Electrical signal tests of frequency weightings, Z weighting Frequency response measured with electrical signal relative to level at 1 khz in reference range. (section 12) Input Level Expected El.+Acous. Resp. Body Influence Corr. Accept - Accept + Deviation Uncertainty [dbv] [db] [db] [db] 1000Hz, Ref. -30.23 90.00 90.00 0.00 0.00 90.00-1.1 1.1 0.00 0.12 63.096Hz -30.23 90.00 89.99 0.00 0.00 89.99-1.5 1.5-0.01 0.12 125.89Hz -30.23 90.00 89.99 0.00 0.00 89.99-1.5 1.5-0.01 0.12 251.19Hz -30.23 90.00 89.99 0.00 0.00 89.99-1.4 1.4-0.01 0.12 501.19Hz -30.23 90.00 89.99 0.00 0.00 89.99-1.4 1.4-0.01 0.12 1995.3Hz -30.23 90.00 90.00 0.00 0.00 90.00-1.6 1.6 0.00 0.12 3981.1Hz -30.23 90.00 89.98 0.00 0.00 89.98-1.6 1.6-0.02 0.12 7943.3Hz -30.23 90.00 89.97 0.00 0.00 89.97-3.1 2.1-0.03 0.12 15849Hz -30.23 90.00 89.98 0.00 0.00 89.98-17.0 3.5-0.02 0.12

Page 7 of 10 4.12. Frequency and time weightings at 1 khz Frequency and time weighting measured at 1 khz with electrical signal in reference range. relative to A-weighted and Fast response. (section 13) LAF, Ref. 94.00 94.00-0.4 0.4 0.00 0.12 LCF 94.00 94.00-0.4 0.4 0.00 0.12 LZF 94.00 94.00-0.4 0.4 0.00 0.12 LAS 94.00 94.00-0.4 0.4 0.00 0.12 LAeq 94.00 94.00-0.4 0.4 0.00 0.12 4.13. Level linearity on the reference level range, Upper Level linearity in reference range, measured at 8 khz until overload. (section 14) 94 db 94.00 94.00-1.1 1.1 0.00 0.12 99 db 99.00 99.00-1.1 1.1 0.00 0.12 104 db 104.00 104.00-1.1 1.1 0.00 0.12 109 db 109.00 109.00-1.1 1.1 0.00 0.12 114 db 114.00 114.03-1.1 1.1 0.03 0.12 119 db 119.00 119.03-1.1 1.1 0.03 0.12 124 db 124.00 124.03-1.1 1.1 0.03 0.12 129 db 129.00 129.03-1.1 1.1 0.03 0.12 130 db 130.00 130.03-1.1 1.1 0.03 0.12 131 db 131.00 131.03-1.1 1.1 0.03 0.12 132 db 132.00 132.03-1.1 1.1 0.03 0.12 133 db 133.00 133.03-1.1 1.1 0.03 0.12 134 db 134.00 134.03-1.1 1.1 0.03 0.12 135 db 135.00 135.03-1.1 1.1 0.03 0.12 136 db 136.00 136.03-1.1 1.1 0.03 0.12

Page 8 of 10 4.14. Level linearity on the reference level range, Lower Level linearity in reference range, measured at 8 khz down to lower limit, or until underrange. (section 14) 94 db 94.00 94.00-1.1 1.1 0.00 0.12 89 db 89.00 89.01-1.1 1.1 0.01 0.12 84 db 84.00 84.01-1.1 1.1 0.01 0.12 79 db 79.00 78.96-1.1 1.1-0.04 0.12 74 db 74.00 73.95-1.1 1.1-0.05 0.12 69 db 69.00 68.95-1.1 1.1-0.05 0.12 64 db 64.00 63.95-1.1 1.1-0.05 0.12 59 db 59.00 58.95-1.1 1.1-0.05 0.12 54 db 54.00 53.95-1.1 1.1-0.05 0.12 49 db 49.00 48.95-1.1 1.1-0.05 0.12 44 db 44.00 43.93-1.1 1.1-0.07 0.12 39 db 39.00 38.93-1.1 1.1-0.07 0.30 35 db 35.00 34.94-1.1 1.1-0.06 0.30 34 db 34.00 33.94-1.1 1.1-0.06 0.30 33 db 33.00 32.95-1.1 1.1-0.05 0.30 32 db 32.00 31.97-1.1 1.1-0.03 0.30 31 db 31.00 30.97-1.1 1.1-0.03 0.30 30 db 30.00 29.98-1.1 1.1-0.02 0.30 4.15. Toneburst response, Time-weighting Fast Response to 4 khz toneburst measured in reference range, relative to continuous signal. (section 16) Continuous, Ref. 132.00 132.00-0.8 0.8 0.00 0.11 200 ms Burst 131.00 131.01-0.8 0.8 0.01 0.11 2 ms Burst 114.00 113.96-1.8 1.3-0.04 0.11 0.25 ms Burst 105.00 104.89-3.3 1.3-0.11 0.11 4.16. Toneburst response, Time-weighting Slow Response to 4 khz toneburst measured in reference range, relative to continuous signal. (section 16) Continuous, Ref. 132.00 132.00-0.8 0.8 0.00 0.11 200 ms Burst 124.60 124.58-0.8 0.8-0.02 0.11 2 ms Burst 105.00 104.97-3.3 1.3-0.03 0.11

Page 9 of 10 4.17. Toneburst response, Leq Response to 4 khz toneburst measured in reference range, relative to continuous signal. (section 16) Continuous, Ref. 132.00 132.00-0.8 0.8 0.00 0.11 200 ms Burst 115.00 115.01-0.8 0.8 0.01 0.11 2 ms Burst 95.00 94.98-1.8 1.3-0.02 0.11 0.25 ms Burst 86.00 85.88-3.3 1.3-0.12 0.11 4.18. Peak C sound level, 8 khz Peak-response to a 8 khz single- cycle sine measured in least-sensitive range, relative to continuous signal. (section 17) Continuous, Ref. 130.00 130.00-0.4 0.4 0.00 0.11 Single Sine 133.40 134.47-2.4 2.4 1.07 0.40 4.19. Peak C sound level, 500 Hz Peak-response to a 500 Hz half-cycle sine measured in least-sensitive range, relative to continuous signal. (section 17) Continuous, Ref. 130.00 130.00-0.4 0.4 0.00 0.11 Half-sine, Positive 132.40 131.93-1.4 1.4-0.47 0.40 Half-sine, Negative 132.40 131.93-1.4 1.4-0.47 0.40 4.20. Overload indication Overload indication in the least sensitive range determined with a 4 khz positive/negative half-cycle signal. (section 18) Accept - Accept + Deviation Uncertainty [db] [db] [db] [db] [db] Continuous 135.00-0.4 0.4 0.00 0.20 Half-sine, Positive 138.40-10.0 10.0 3.40 0.20 Half-sine, Negative 138.50-10.0 10.0 3.50 0.20 Difference 138.50-1.8 1.8 0.10 0.30 4.21. Environmental conditions, Following calibration Actual environmental conditions following calibration. (section 7) [Deg C/ kpa / %RH] Air temperature 23.10 Air pressure 102.48 Relative humidity 48.00

Page 10 of 10 DANAK The Danish Accreditation and Metrology Fund - DANAK - is managing the Danish accreditation scheme based on a contract with the Danish Safety Technology Authority under the Danish Ministry of Economics and Business Affairs who is responsible for the legislation on accreditation in Denmark. The fundamental criteria for accreditation are described in DS/EN ISO/IEC 17025: "General requirements for the competence of testing and calibration laboratories, and in DS/EN ISO/IEC 15189 Medical laboratories Particular requirements for quality and competence respectively. DANAK uses guidance documents to clarify the requirements in the standards, where this is considered to be necessary. These will mainly be drawn up by the European co-operation for Accreditation (EA) or the International Laboratory Accreditation Co-operation (ILAC) with a view to obtaining uniform criteria for accreditation worldwide. In addition, the Danish Safety Technology Authority issues Technical Regulations prepared by DANAK with specific requirements for accreditation that are not contained in the standards. In order for a laboratory to be accredited it is, among other things, required: - that the laboratory and its personnel are free from any commercial, financial or other pressures, which might influence their impartiality; - that the laboratory operates a documented management system, and has a management that ensures that the system is followed and maintained; - that the laboratory has at its disposal all items of equipment, facilities and premises required for correct performance of the service that it is accredited to perform; - that the laboratory has at its disposal personnel with technical competence and practical experience in performing the services that they are accredited to perform; - that the laboratory has procedures for traceability and uncertainty calculations; - that accredited testing, calibration or medical examination are performed in accordance with fully validated and documented methods; - that accredited services are performed and reported in confidentiality with the customer and in compliance with the customer s request; - that the laboratory keeps records which contain sufficient information to permit repetition of the accredited test, calibration or medical examination; - that the laboratory is subject to surveillance by DANAK on a regular basis; Reports carrying DANAK s accreditation mark are used when reporting accredited services and show that these have been performed in accordance with the rules for accreditation.