Executive Summary. Introduction WHITEPAPER

Similar documents
Characterization of Single Wall Carbon Nanotubes (SWNTs) by combining Dynamic Light Scattering and Raman Spectroscopy

Understanding the colloidal stability of protein therapeutics using dynamic light scattering

Use of DLS/Raman to study the thermal unfolding process of lysozyme

Component specific particle characterisation of the active components in a pharmaceutical topical formulations

GPC/SEC Analysis of Polymer Degradation

Nanobubble Applications and Characterization by Nanoparticle Tracking Analysis

Discriminating between polymorphs of acetaminophen using Morphologically-Directed Raman Spectroscopy (MDRS)

10 REASONS THAT THE ZETASIZER NANO IS CHOSEN FOR SCIENTIFIC SUCCESS

GPC/SEC Analysis of Polymer Solutions Used in Inkjet Printing

Differentiation of polymer branching and composition using the Mark Houwink plot

Introduction to the calculators in the Zetasizer software

The power of multi-detector SEC in the analysis of antibodies

Overcoming and quantifying Wall Slip in measurements made on a rotational rheometer

Optimization of PLA/PLGA molecular weight and structure to suit final application requirements

Understanding the conformational stability of protein therapeutics using Raman spectroscopy

How to use GPC/SEC for compositional analysis

Determining cure profile and post-cure shrinkage of photopolymers using UV accessory on a rotational rheometer

Studying the Effect of Steric Layer Thickness on Emulsion Stability

Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy

Using rheology to study the hardness and spreadability of butter

How switching mobile phases can improve your OMNISEC results

Evaluating the rheological properties of hyaluronic acid hydrogels for dermal filler applications

Using the Zetasizer Nano to optimize formulation stability

DEVELOPING A BIOFORMULATION STABILITY PROFILE

MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

Measuring the rheology of thermoplastic polymer melts

Measurements of protein electrophoretic mobility using the Zetasizer Nano ZSP

Laser diffraction and automated imaging: complementary techniques for nasal spray development

The ultimate in desktop particle characterization

Zeta potential - An introduction in 30 minutes

Sample measurements to demonstrate Zetasizer specifications (Zetasizer Nano, Zetasizer APS, Zetasizer μv)

ZS90. The ultimate in desktop particle characterization. Particle size. Zeta potential. Molecular weight

next generation Welcome to the Dispersion options Smarter particle sizing Your sample, expertly processed and prepared Particle size

MEASURING PROTEIN AGGREGATION WITH THE VISCOTEK SEC-MALS 20

Inform is a series of white papers designed to provide advice on material characterization issues. Mie theory The rst 100 years

Gold Nanoparticle Applications and Characterization by Nanoparticle Tracking Analysis

The ultimate in desktop particle characterization

REVERSE ENGINEERING PHARMACEUTICAL FORMULATION USING THE MORPHOLOGI G3-ID.

The Diffusion Barrier Technique, Practical Aspects and Data interpretation

Measuring the rheology of polymer solutions

Determining Carbon Nanotube Properties from Raman. Scattering Measurements

A basic guide to particle characterization

Electrophoretic Light Scattering Overview

KINEXUS DSR SERIES REDEFINING RHEOMETER CAPABILITIES FOR ASPHALT TESTING

Morphologically directed chemical identification Coupling particle characterization by morphological imaging with Raman spectroscopy

A Basic Guide to INFORM WHITE PAPER. Abstract:

Bohlin. Rheological instruments backed with rheological experience. Rheological properties

Liberating the Nanotube: From Lab to Large Scale Production

Particle Analysis at the Touch of a Button. Litesizer series

Carbon Nanotube Reference Materials and Characterization Jeffrey A. Fagan

For more information, please contact: or +1 (302)

Surfactant-free exfoliation of graphite in aqueous solutions

Litesizer Sheet 1. [Home]

VIBRATION CHARACTERISTICS OF EMBEDDED DOUBLE WALLED CARBON NANOTUBES SUBJECTED TO AN AXIAL PRESSURE

Interaction between Single-walled Carbon Nanotubes and Water Molecules

Supporting Information

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

ZETASIZER NANO Series PERFORMANCE, SIMPLICITY, VERSATILITY

CARBON NANOTUBE ANALYSIS USING THE TSI LIBS DESKTOP ANALYZER

status solidi Raman spectroscopy of ( n, m )-identified individual single-walled carbon nanotubes

KINEXUS SERIES REDEFINING RHEOMETER CAPABILITIES

Fig. 1: Raman spectra of graphite and graphene. N indicates the number of layers of graphene. Ref. [1]

Metallic/semiconducting ratio of carbon nanotubes in a bundle prepared using CVD technique

Novel instrumentation to gain insight into the aggregation state of proteins by Taylor Dispersion Analysis: a comparison

Measuring Lysozyme Monomer at 0.1 mg/ml Concentration. Equipment used : Sample Preparation and Measurement :

Processing and Properties of Highly Enriched Double-Walled. Carbon Nanotubes: Supplementary Information

Particle Characterization Laboratories, Inc.

Monitoring the Aggregation of Particles through Raman Spectroscopy

Using runt Disposable Cuvettes

Malvern Macromolecular Solutions. Innovative Solutions in Material Characterization

Probing the Kinetics of Ligand Exchange on Colloidal Gold. Nanoparticles by Surface-Enhanced Raman Scattering

Supplementary Information

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Investigating the Relationship Between the Rheological Properties of Hyaluronic Acid and its Molecular Weight and Structure using Multidetector

KINEXUS SERIES REDEFINING RHEOMETER CAPABILITIES

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Holographic Characterization of Agglomerates in CMP Slurries

Supplementary Information

Supplementary information for:

Accessory Publication

MASTERSIZER 3000 SMARTER PARTICLE SIZING

Particle Analysis at the Touch of a Button. Litesizer series

Introduction to Dynamic Light Scattering for Particle Size Determination

Graphene oxide as acid catalyst for the room temperature. ring opening of epoxides

TECHNICAL SPECIFICATION

30 Ossipee Road P.O. Box 9101 Newton, MA Phone: Fax: TEST REPORT

Detonation Nanodiamond Suspensions

Near-field Raman spectroscopy using a sharp metal tip

Application. Authors. Abstract. Introduction. Hydrocarbon Processing

Imaging Carbon materials with correlative Raman-SEM microscopy. Introduction. Raman, SEM and FIB within one chamber. Diamond.

Supporting Information. Controlled mineralization by extracellular matrix: monodisperse, colloidal stable calcium phosphate-hyaluronan

LS Spectrometer. The DLS and SLS system for sophisticated research

Use of SEC-MALS. (Size Exclusion Chromatography - Multi Angle. Light Scattering) for protein quality and characterization

Fate, Transport, and Toxicity of Nanoparticles in the Environment

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

Size and Zeta Potential of Colloidal Gold Particles

TECHNICAL SPECIFICATION

Manifestation of Structure of Electron Bands in Double-Resonant Raman Spectra of Single-Walled Carbon Nanotubes

Raman spectroscopy at the edges of multilayer graphene

VASCO Flex TM Remote Particle size Analyzer

Transcription:

The Characterization of Single Wall Carbon Nanotubes Using The Malvern Instruments Helix System: Integrating Dynamic Light Scattering (DLS) and Raman Spectroscopy Executive Summary The combination of DLS and Raman spectroscopy offers the ability to measure the length, diameter, and chirality of carbon nanotubes in a single experiment. These parameters can be used with existing empirical knowledge of nanotubes to predict their conductivity and strength characteristics. Dynamic Light Scattering (DLS) is widely accepted as a method for determining the hydrodynamic radius of nanoscale particles in suspension. While the use of DLS to determine the size of non-spherical particles (such as nanotubes) presents unique challenges, analytical methods have been developed to extract this information from the data. Raman spectroscopy collects detailed structural information through access to fundamental molecular vibrations. The positions, shapes and intensities of the resulting bands can provide insight into structural details of the species under investigation. A wealth of publications document the use of Raman spectroscopy to characterize carbon nanotubes, including chirality and quality parameters. Introduction Owing to their readily-tunable thermal and electrical properties, incredible strength, and novel optical properties, carbon nanotubes (CNTs) have quickly established their place in existing commercial products where currently 75% of CNT applications are being developed in the energy, electronics and composites sectors. 1 Moreover, they offer immense promise for future medical and consumer product development. Estimates conclude that government nanotechnology funding will eclipse $1.0 billion per year in at least five countries by 2014, 2 totaling more than $12 billion worldwide. In 2011, the revenue for CNT work was approximated to be $300 million and by 2016, production volume is expected to see a 50% increase from today's levels. 1 CNTs are primarily produced in the form of multi-wall nanotubes (MWNTs), comprising multiple layers of cylinders of graphene, because of their cost-effectiveness relative to their single-wall counterpart (SWNTs). However for specific applications, where a wellcharacterized, defect-free system is preferred, the unique electronic and mechanical properties that SWNTs offer are desired. Because of the continuing trend toward Malvern Instruments Worldwide Sales and service centres in over 65 countries www.malvern.com/contact 2014 Malvern Instruments Limited

the miniaturization of electronics, demand for SWNTs should increase which will encourage more cost-effective production and purification methods. 3 The proliferation of carbon nanotubes in research and commercial applications has led to the need for unique analytical approaches that can rapidly characterize them. Determination of the structure of the nanotubes, defined by their chiral index (x, y), 4 is critical to understanding their conductive properties. Likewise, the length and diameter of the structures are important to predicting their behavior during commercial applications. As no single technique is capable of providing all of the required information, a hybrid technique is a natural approach to elucidating the needed parameters. The combination of Dynamic Light Scattering (DLS) and Raman spectroscopy offers the potential to provide the structural information needed to characterize these samples. The frequency of the radial breathing mode (ν RBM ) measured by Raman spectroscopy has been used as a direct probe of the chirality, and therefore diameter, of singlewalled carbon nanotubes (SWNT). 5 The position of the RBM band is sensitive to changes in the bonding structure of the nanotube, and its chirality. Thus, both the chirality and the diameter of the SWNT's can be determined by Raman spectroscopy. DLS has seen widespread use as a technique for characterizing the hydrodynamic radius of nanoscale materials in suspension. Brownian motion of particles results in fluctuations of the intensity of scattered light, the time scale of which is related to the particle size. Although DLS assumes a spherical particle, corrections can be made to compensate for the high aspect ratio of nanotubes. An effective length can thereby be extracted from the results, which when coupled with an analysis of the RBM band, allows the accurate determination of nanotube length. Materials and Methods A Helix 6 from Malvern Instruments has been used to obtain DLS (nanoscale particle size) and Raman (structural information) data sequentially on a single sample. The Helix system uses a proprietary non-invasive backscatter (NIBS) detector with dynamic (DLS), static (SLS) and electrophoretic (ELS) light scattering to measure the hydrodynamic radius of particles from 0.15 nm to 5 µm. Raman spectra are collected using 785 nm excitation (~280 mw) from 150 to 1925 cm -1 at 4 cm -1 resolution. SWNT samples containing a mixture of chiralities were prepared by tip-sonicating 2 mg of SWNT powder in a 10 ml solution of 0.2% w/w chitosan and 1% w/v acetic acid in Nanopure DI water to produce a stable dispersion consisting of individual nanotubes complexed with chitosan. Sample aliquots (~50 µl) are placed into a proprietary cuvette with thin quartz windows and positioned in a temperature controlled compartment (4 to 90 C ± 0.1 C). The data described here were collected at 25 C. Results and Discussion Raman spectroscopy can reveal a wealth of information about a nanotube sample. A characteristic spectrum of nanotubes consists of the radial breathing mode (100-350 cm -1 ), D mode (~1300 cm -1 ) and G mode (~1600 cm -1 ). The D mode is an indicator of structural defects which can be caused by the presence of C(sp 3 )-C(sp 3 ) bonds while the G mode corresponds to the vibrations of the C(sp 2 )-C(sp 2 ) bonds composing the 2 The Characterization of Single Wall Carbon Nanotubes Using The Malvern Instruments Helix System: Integrating Dynamic Light Scattering (DLS) and Raman Spectroscopy

tube. The quality factor of nanotubes can be measured using the following equation (eqn 1): 7 D represents the maximum intensity peak of the D-band, G represents the peak of the G-band and B represents the minimum value between the peaks associated with D- and G-bands (Figure 1). Q ranges from 0 to 1 where 1 is indicative of perfect quality. It is good practice to measure Q for each batch because a significant number of defects will detrimentally affect the mechanical and electrical properties of SWNTs. 8 To demonstrate Raman spectroscopy's ability to evaluate quality, a commercial batch of SWNTs containing several chiralities was centrifuged at 21000 x g after suspending in a solution of chitosan. Since defective nanotubes tend to be more prone to aggregation, they will sediment during centrifugation. 9 With Raman spectroscopy, Figure 1 illustrates that the change in quality of a SWNT sample can be monitored. Figure 1: Raman spectra of a batch of carbon nanotubes before (blue) and after purification (red) via centrifugation. The intensity of the two spectra was normalized with respect to the maximum height of their G-bands. According to eqn. 1, the Q factor for the commercially available batch (precentrifugation) is 0.87 while the Q factor after centrifugation is 0.92. This increase in the Q factor suggests that after centrifugation, some of the defective nanotubes can be removed and most importantly, the data indicates that Raman spectroscopy can be used to evaluate the quality of a batch of SWNT. The radial breathing mode (RBM) region of a Raman spectrum can show the chiralities and, in turn, the diameters of the various species that are present in a nanotube mixture. The diameter of a SWNT (d) can be expressed in nanometers as a function of the RBM frequency (ν) in cm -1 by the following (eqn. 2): 5 The diameter of the SWNT can also be expressed as a function of the chirality indices (x, y) in eqn. 3: 5 3 The Characterization of Single Wall Carbon Nanotubes Using The Malvern Instruments Helix System: Integrating Dynamic Light Scattering (DLS) and Raman Spectroscopy

Combining eqns 2 and 3 yields eqn. 4 that directly relates the RBM frequency from the Raman spectrum to the chirality of the SWNT. From these equations, the relative purity of a specific batch of SWNTs can be evaluated by identifying the desired peak in relation to any neighboring ones. The frequency of the desired peak is determined through eqn. 4 by inputting the known indices of the SWNT. For example, the Raman spectra of two commercial batches of (6,5) and (7,6) show the presence of other chiralities in the RBM region (Figure 2). Figure 2: Raman spectra of two commercial samples advertised as primarily A) 6,5 and B) 7,6. From these mixtures, the relative purity of a desired chirality can be ascertained. Data collected from dynamic light scattering (DLS) yields the size distribution as a bulk average of particles diffusing in solution. It assumes a spherical particle with an aspect ratio of 1. However, due to its cylindrical nature, a nanotube has an aspect ratio of about 1000, but its hydrodynamic diameter can still be accurately determined by DLS 4 The Characterization of Single Wall Carbon Nanotubes Using The Malvern Instruments Helix System: Integrating Dynamic Light Scattering (DLS) and Raman Spectroscopy

and verified theoretically with the following eqns (5 and 6) 10 describing the diffusion coefficients: where D is the diffusion coefficient, k is the Boltzmann constant, T is temperature, η is the viscosity, D h is the hydrodynamic diameter, and L and d are the length and diameter of the nanotube, respectively. Combining the equations relates D h to the dimensions of the nanotube in the form of eqn 7: The Helix which couples DLS measurements and Raman spectroscopy conveniently allows the acquisition of diameter and length data from a single batch of SWNTs. Using eqn 6, the theoretical hydrodynamic diameter of (6,5) nanotubes with a radial diameter of 0.75 nm as determined from Raman spectroscopy, and a length of at least 700 nm, 11 is 100 nm. This theoretical hydrodynamic diameter is in excellent agreement with the hydrodynamic diameter (91-106 nm) obtained through the integrated DLS measurement (Figure 3). Moreover if the length of the nanotube were unknown, it can be calculated with the same equation using the measured hydrodynamic diameter from the DLS (assume 100 nm based on the DLS range) and the diameter from the Raman (0.75 nm) to obtain about 720 nm, which is in agreement with the value (> 700 nm) from Sigma-Aldrich. 11 Given the high aspect ratio (1000:1) that is inherent in the SWNT, it is important to note that the smallest inaccuracy in the DLS measurement of the hydrodynamic diameter would result in dramatic changes in the calculated length. Therefore the calculated length should be considered as only an approximation. Figure 3: Graph depicting a DLS measurement of a suspension of (6,5)-SWNT dispersed in 0.2% w/w chitosan in water. The DLS measurement was graphed as an average of 14 runs and chitosan has a molecular weight ranging from 190-310 kda. 5 The Characterization of Single Wall Carbon Nanotubes Using The Malvern Instruments Helix System: Integrating Dynamic Light Scattering (DLS) and Raman Spectroscopy

Conclusion Using an analytical instrument that couples dynamic light scattering (DLS) and Raman spectroscopy into a single platform provides a convenient tool for probing the size, structural properties and quality of SWNTs. It is a convenient and powerful tool for the analysis of commercial batches of carbon nanotubes as well as a means for the characterization of material generated from new manufacturing processes. Additionally, the capabilities of this instrument will be of significant value for the study of many other types of nanomaterials and biopharmaceuticals and these topics will be the subject of future application notes. References 1. Carbon Nanotube Futures Markets CCM June 2014 2. http://cientifica.com/wp-content/uploads/downloads/2011/07/global- Nanotechnology-Funding-Report-2011.pdf 3. http://www.nanocyl.com/en/cnt-expertise-centre/carbon-nanotubes/single-wall- Nanotubes-SWNT 4. L-C. Qin. Phys. Chem. Chem. Phys., 2007, 9, 31. 5. C. Thomsen, H. Telg, J. Maultzsch, and S. Reich. Phys. Stat. Sol. (b),2005, 242, 1802. 6. Lewis, E.N. U.S. Patent Pending 7. http://www.swentnano.com/tech/docs/products/sg65i%20tds.pdf 8. A.V. Narlikar, & Y.Y. Fu. Oxford Handbook of Nanoscience and Technology: Frontiers and Advances. (Oxford Univ. Press, Oxford, 2009) 9. M. S. Arnold, A. A. Green, J. F. Huvat, S. I. Stupp and M. C. Hersam. Nat. Nanotechnol.2006, 1, 60. 10. N. Nair, W. Kim, R. D. Braatz, and M. S. Strano. Langmuir, 2008, 24, 1790. 11. http://www.sigmaaldrich.com/catalog/product/aldrich/704148 6 The Characterization of Single Wall Carbon Nanotubes Using The Malvern Instruments Helix System: Integrating Dynamic Light Scattering (DLS) and Raman Spectroscopy

Malvern Instruments Limited Grovewood Road, Malvern, Worcestershire, UK. WR14 1XZ Tel: +44 1684 892456 Fax: +44 1684 892789 www.malvern.com Malvern Instruments is part of Spectris plc, the Precision Instrumentation and Controls Company. Spectris and the Spectris logo are Trade Marks of Spectris plc. All information supplied within is correct at time of publication. Malvern Instruments pursues a policy of continual improvement due to technical development. We therefore reserve the right to deviate from information, descriptions, and specifications in this publication without notice. Malvern Instruments shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Malvern Instruments owns the following registered trademarks: Bohlin, FIPA, Insitec, ISYS, Kinexus, Malvern, Malvern 'Hills' logo, Mastersizer, Morphologi, Rosand, 'SEC-MALS', Viscosizer, Viscotek, Viscogel and Zetasizer. 2014 Malvern Instruments Limited