Control Systems I Lecture 10: System Specifications

Similar documents
Control Systems I. Lecture 9: The Nyquist condition

Classify a transfer function to see which order or ramp it can follow and with which expected error.

Control Systems I. Lecture 6: Poles and Zeros. Readings: Emilio Frazzoli. Institute for Dynamic Systems and Control D-MAVT ETH Zürich

Control Systems I. Lecture 9: The Nyquist condition

Control Systems I. Lecture 7: Feedback and the Root Locus method. Readings: Jacopo Tani. Institute for Dynamic Systems and Control D-MAVT ETH Zürich

Control Systems I. Lecture 7: Feedback and the Root Locus method. Readings: Guzzella 9.1-3, Emilio Frazzoli

Systems Analysis and Control

Control Systems I. Lecture 5: Transfer Functions. Readings: Emilio Frazzoli. Institute for Dynamic Systems and Control D-MAVT ETH Zürich

Control Systems I. Lecture 4: Diagonalization, Modal Analysis, Intro to Feedback. Readings: Emilio Frazzoli

Automatic Control 2. Loop shaping. Prof. Alberto Bemporad. University of Trento. Academic year

Control Systems I. Lecture 2: Modeling. Suggested Readings: Åström & Murray Ch. 2-3, Guzzella Ch Emilio Frazzoli

Systems Analysis and Control

EE C128 / ME C134 Fall 2014 HW 6.2 Solutions. HW 6.2 Solutions

ECSE 4962 Control Systems Design. A Brief Tutorial on Control Design

Exercise 1 (A Non-minimum Phase System)

Homework 7 - Solutions

CDS 101/110a: Lecture 8-1 Frequency Domain Design

Digital Control Systems

Discrete Systems. Step response and pole locations. Mark Cannon. Hilary Term Lecture

Exercise 1 (A Non-minimum Phase System)

Prüfung Regelungstechnik I (Control Systems I) Übersetzungshilfe / Translation aid (English) To be returned at the end of the exam!

The loop shaping paradigm. Lecture 7. Loop analysis of feedback systems (2) Essential specifications (2)

MEM 355 Performance Enhancement of Dynamical Systems

Systems Analysis and Control

Intro to Frequency Domain Design

MEM 355 Performance Enhancement of Dynamical Systems

6.1 Sketch the z-domain root locus and find the critical gain for the following systems K., the closed-loop characteristic equation is K + z 0.

Raktim Bhattacharya. . AERO 422: Active Controls for Aerospace Vehicles. Frequency Response-Design Method

16.30/31, Fall 2010 Recitation # 2

Outline. Classical Control. Lecture 1

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Mechanical Engineering Dynamics and Control II Fall 2007

EE C128 / ME C134 Fall 2014 HW 8 - Solutions. HW 8 - Solutions

Frequency methods for the analysis of feedback systems. Lecture 6. Loop analysis of feedback systems. Nyquist approach to study stability

Robust Performance Example #1

Chapter 2. Classical Control System Design. Dutch Institute of Systems and Control

Transient response via gain adjustment. Consider a unity feedback system, where G(s) = 2. The closed loop transfer function is. s 2 + 2ζωs + ω 2 n

1 (20 pts) Nyquist Exercise

CHAPTER 7 : BODE PLOTS AND GAIN ADJUSTMENTS COMPENSATION

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Mechanical Engineering Dynamics and Control II Fall K(s +1)(s +2) G(s) =.

Systems Analysis and Control

FREQUENCY-RESPONSE DESIGN

Lecture 5: Frequency domain analysis: Nyquist, Bode Diagrams, second order systems, system types

Course roadmap. Step response for 2nd-order system. Step response for 2nd-order system

MAS107 Control Theory Exam Solutions 2008

Introduction to Feedback Control

Module 3F2: Systems and Control EXAMPLES PAPER 2 ROOT-LOCUS. Solutions

Control Systems I. Lecture 1: Introduction. Suggested Readings: Åström & Murray Ch. 1, Guzzella Ch. 1. Emilio Frazzoli

DESIGN USING TRANSFORMATION TECHNIQUE CLASSICAL METHOD

r + - FINAL June 12, 2012 MAE 143B Linear Control Prof. M. Krstic

Plan of the Lecture. Goal: wrap up lead and lag control; start looking at frequency response as an alternative methodology for control systems design.

100 (s + 10) (s + 100) e 0.5s. s 100 (s + 10) (s + 100). G(s) =

MAE143a: Signals & Systems (& Control) Final Exam (2011) solutions

AN INTRODUCTION TO THE CONTROL THEORY

Engraving Machine Example

Table of Laplacetransform

Control of Manufacturing Processes

AMME3500: System Dynamics & Control

Frequency Response Techniques

Dr Ian R. Manchester Dr Ian R. Manchester AMME 3500 : Review

Lecture 7:Time Response Pole-Zero Maps Influence of Poles and Zeros Higher Order Systems and Pole Dominance Criterion

(b) A unity feedback system is characterized by the transfer function. Design a suitable compensator to meet the following specifications:

Today (10/23/01) Today. Reading Assignment: 6.3. Gain/phase margin lead/lag compensator Ref. 6.4, 6.7, 6.10

FEEDBACK CONTROL SYSTEMS

Due Wednesday, February 6th EE/MFS 599 HW #5

Raktim Bhattacharya. . AERO 422: Active Controls for Aerospace Vehicles. Basic Feedback Analysis & Design

IC6501 CONTROL SYSTEMS

Systems Analysis and Control

EE3CL4: Introduction to Linear Control Systems

Digital Control: Summary # 7

Stability of CL System

Introduction. Performance and Robustness (Chapter 1) Advanced Control Systems Spring / 31

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

ECE317 : Feedback and Control

Chapter 7 - Solved Problems

Systems Analysis and Control

R a) Compare open loop and closed loop control systems. b) Clearly bring out, from basics, Force-current and Force-Voltage analogies.

Frequency domain analysis

INTRODUCTION TO DIGITAL CONTROL

Compensator Design to Improve Transient Performance Using Root Locus

Systems Analysis and Control

ROOT LOCUS. Consider the system. Root locus presents the poles of the closed-loop system when the gain K changes from 0 to. H(s) H ( s) = ( s)

(Continued on next page)

EE C128 / ME C134 Fall 2014 HW 9 Solutions. HW 9 Solutions. 10(s + 3) s(s + 2)(s + 5) G(s) =

Übersetzungshilfe / Translation aid (English) To be returned at the end of the exam!

6.302 Feedback Systems Recitation 16: Compensation Prof. Joel L. Dawson

9. Two-Degrees-of-Freedom Design

EE 4343/ Control System Design Project LECTURE 10

Topic # Feedback Control

Topic # Feedback Control Systems

Systems Analysis and Control

Systems Analysis and Control

Linear Control Systems Lecture #3 - Frequency Domain Analysis. Guillaume Drion Academic year

CYBER EXPLORATION LABORATORY EXPERIMENTS

Exam. 135 minutes + 15 minutes reading time

K(s +2) s +20 K (s + 10)(s +1) 2. (c) KG(s) = K(s + 10)(s +1) (s + 100)(s +5) 3. Solution : (a) KG(s) = s +20 = K s s

MAE 143B - Homework 9

Software Engineering 3DX3. Slides 8: Root Locus Techniques

Review: transient and steady-state response; DC gain and the FVT Today s topic: system-modeling diagrams; prototype 2nd-order system

Lecture 1: Feedback Control Loop

Controls Problems for Qualifying Exam - Spring 2014

Transcription:

Control Systems I Lecture 10: System Specifications Readings: Guzzella, Chapter 10 Emilio Frazzoli Institute for Dynamic Systems and Control D-MAVT ETH Zürich November 24, 2017 E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 1 / 27

Tentative schedule # Date Topic 1 Sept. 22 Introduction, Signals and Systems 2 Sept. 29 Modeling, Linearization 3 Oct. 6 Analysis 1: Time response, Stability 4 Oct. 13 Analysis 2: Diagonalization, Modal coordinates. 5 Oct. 20 Transfer functions 1: Definition and properties 6 Oct. 27 Transfer functions 2: Poles and Zeros 7 Nov. 3 Analysis of feedback systems: internal stability, root locus 8 Nov. 10 Frequency response 9 Nov. 17 Analysis of feedback systems 2: the Nyquist condition 10 Nov. 24 Specifications for feedback systems 11 Dec. 1 Loop Shaping 12 Dec. 8 PID control 13 Dec. 15 Implementation issues 14 Dec. 22 Robustness E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 2 / 27

The Nyquist condition and robustness margins If the open-loop is stable, then we know that in order for the closed-loop to be stable the Nyquist plot of L(s) should NOT encircle the 1 point. The gain margin and phase margin measure how close the system is to closed-loop instability. E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 3 / 27

The Nyquist condition on Bode plots If the open-loop is stable, then we know that in order for the closed-loop to be stable the Nyquist plot of L(s) should NOT encircle the 1 point. In other words, L(jω) < 1 whenever L(jω) = 180. On the Bode plot, this means that the magnitude plot should be below the 0 db line if/when the phase plot crosses the 180 line. Remember that this condition is valid only if the open loop is stable. In all other cases (including non-minimum phase zeros) it is strongly recommended to double check any conclusion on closed-loop stability using other methods (Nyquist, root locus). E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 4 / 27

Gain and Phase Margin The distance from the Nyquist plot to the 1 point is a measure of robustness. On the bode plot, it is easy to measure this distance in terms of gain and phase margin. 40 20 0 Bode Diagram Magnitude (db) -20-40 -60-80 -100-120 -90-135 Phase (deg) -180-225 -270 E. Frazzoli 10 (ETH) -1 10 0 Lecture 10: Control 10 1 Systems I 10 2 24/11/2017 10 3 5 / 27

Summary of the previous lecture In the previous lecture, we learned: How to sketch a polar plot (and hence a Nyquist plot), based on Bode plots The Nyquist condition to determine closed-loop stability using a Nyquist plot. How to check the Nyquist condition on a Bode plot. How to quickly assess the robustness of a feedback control system. Now we have three graphical methods to study closed-loop stability given the (open-)loop transfer function. 1 Root locus: always correct if applicable (assumes finite-dimensional system) 2 Nyquist: always correct, always appplicable; 3 Bode: very useful for control system design, however may be misleading in determining closed-loop stability (e.g., for open-loop unstable systems). So far we have only looked at analysis issues, i.e., how to determine closed-loop stability; from now on we will concentrate on control synthesis, i.e., how to design a feedback control system that makes a system behave as desired. E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 6 / 27

Plan for this lecture We have seen how to establish whether the closed-loop system will be stable or not, based on the (open-)loop transfer function. The next step is to evaluate how well the closed-loop will behave, e.g., how quickly and how closely the closed-loop system can track commands, how well it can reject disturbances, modeling errors, and noise. Specifications on the closed-loop behavior are typically given using two main paradigms, plus one that can be seen both ways: Steady-state error Time-domain specifications Frequency-domain specifications In this lecture we will learn about both kinds of specifications, and what they mean in terms of the closed-loop system and/or the (open-)loop transfer function. E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 7 / 27

Proportional feedback E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 8 / 27

Steady-state error to step inputs r e u C Recall the following transfer function (and that L(s) = P(s)C(s)): P r e, d e : S(s) = d y 1 1 + L(s) If the input is a unit step, i.e., r(t) = 1 = e 0t for t 0, the steady-state output will be e ss (t) = S(0)e 0t = 1, for t 0. 1 + L(0) So if lim s 0 L(s) = k Bode = k DC is finite then the steady-state error to a unit step is 1/(1 + k DC ). If the limit is infinite (i.e., there is a pole at s = 0, i.e., L(s) contains an integrator), the steady-state error is zero. n E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 9 / 27

Steady-state error to higher-order ramps More in general, one may ask the closed-loop system to have a finite steady-state error to a unit ramp of order m = {0, 1, 2,...}, i.e., r(t) = 1 m! tm, t 0. The steady-state error can be computed as ( e ss (t) = lim s 0 1 1 + L(s) est s m ) E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 10 / 27

System type The result depends on the type of the system, i.e., the number of integrators in L(s), i.e., the number of poles of L(s) at s = 0, and is summarized as follows e ss m = 0 m = 1 m = 2 1 Type 0 1 + k Bode 1 Type 1 0 In plain English: k Bode Type 2 0 0 1 k Bode The steady-state error is smaller as the (Bode) gain increases; A requirement to have zero steady-state errors to ramps of order m, is the same as requiring to have at least m + 1 integrators on the path from the error e to the (reference/disturbanc) input. E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 11 / 27

5.3. Time INPUT/OUTPUT domain: RESPONSE step response of a 2nd order system 151 2 1.5 Overshoot M p Output 1 0.5 Rise time T r Settling time T s Steady-state value y ss 0 0 5 10 15 20 25 30 Time [sec] Figure Time 5.9: domain Sample specifications step response. are The usually rise time, given overshoot, in terms settling of the time step and response steady-state of value give the key performance properties of the signal. a 2nd order system: ω 2 n equilibrium point G(s) in the = absence of any input), then we can rewrite the solution as s 2 + 2ζω n s + ω 2 y(t) = (1 e σt cos(ωt)). y(t)=ca } 1 {{ e At n B } +D } CA {{ 1 B }, t > 0. (5.22) Recall that the poles are at s = σ ± jω, and that ωn 2 = σ 2 + ω 2, ζ = σ/ω n. transient steady-state The first E. Frazzoli term(eth) is the transient response Lecture 10: Control andsystems decays I to zero as t. 24/11/2017 The second 12 / 27

Second-order response: shape vs. time scale E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 13 / 27

Analytical approximations Rise time depends primarily on ω n : note that T 100 = π Other formulas available, e.g., T 90 (0.14 + 0.4ζ) 2π Peak time: depends on the frequency ω, T p π ω ; % Overshoot: depends on the damping ζ: 2ω ω n. (assuming ζ < 1). ln M p σπ ω = ζπ, 1 ζ 2 ζ2 = (ln M p) 2 π 2 + (ln M p ) 2. Settling time (e.g., to 2%): depends on the real part of the poles σ, T s = ln 2% ln 2%, σ =. σ T s Note: the settling time is the only relevant specification (in addition to the steady-state error to a unit step) for a first-order system. E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 14 / 27

Dominant poles approximation What if the closed-loop system if of higher order? Often one can approximate it with a second-order (or even first-order) system, and apply the specifications to the approximation. The approximation is based on the concept of dominant poles. Dominant poles are typically those with the largest real part (i.e., the slowest decay rate); Exceptions are made when the poles with the largest real part also have very small residues (typically because of nearby zeros). G(s) = r1 + r2 +... g(t) = r 1e p1t + r 2e p2t +... s p 1 s p 2 E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 15 / 27

Dominant poles approximation examples 130 Consider a third-order system with G(s) = (s + 5)(s + 1 + 5j)(s + 1 5j). The contribution to the response of the pole at s = 5 will decay as e 5t, while that of the poles at s = 1 ± 5j will decay as e t. Dominant pole approximation: G dom (s) = 26 (s + 1 + 5j)(s + 1 5j). 1.6 1.4 G = zpk([],[-5, -1+5*i, -1-5*i],130) full dominant poles only 1.2 1 Amplitude 0.8 0.6 0.4 0.2 0 0 1 2 3 4 5 6 Time (seconds) E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 16 / 27

Dominant poles approximation examples 13 Consider a third-order system with G(s) = (s + 0.5)(s + 1 + 5j)(s + 1 5j). The contribution to the response of the pole at s = 0.5 will decay as e 0.5t, while that of the poles at s = 1 ± 5j will decay as e t. Dominant pole approximation: G dom (s) = 0.5 s + 0.5. 1 0.9 G = zpk([],[-0.5, -1+5*i, -1-5*i],13) full dominant poles only 0.8 0.7 0.6 Amplitude 0.5 0.4 0.3 0.2 0.1 0 0 2 4 6 8 10 12 14 16 18 Time (seconds) E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 17 / 27

Dominant poles approximation examples 21.667(s + 0.6) Consider a third-order system with G(s) = (s + 0.5)(s + 1 + 5j)(s + 1 5j). The zero at s = 1 makes the magnitude of the residue of the pole at s = 0.5 small wrt to the magnitudes of the residues of the other poles effectively we have a near-pole/zero cancellation. Dominant pole approximation: G dom (s) = 1.6 1.4 G = zpk([-0.6],[-0.5, -1+5*i, -1-5*i],21.667) 26 (s + 1 + 5j)(s + 1 5j). full dominant poles only 1.2 1 Amplitude 0.8 0.6 0.4 0.2 0 E. Frazzoli (ETH) 0 1 2 Lecture 3 10: Control 4 Systems 5 I 6 7 8 9 24/11/2017 18 / 27

Using time-domain specifications Time-domain specifications impose constraints on the locations of the dominant closed-loop poles. In particular: Settling time constraints require the real part of the dominant poles to be to the less than some maximum value. Peak overshoot constraints require the damping ratio to be more than some minimum value resulting in a sector of the left half plane. Rise time constraints require that the distance of the dominant poles from the origin, and/or (the absolute value of) the imaginary part of the dominant poles to be more than some minimum value. When checking time-domain specifications, it is particularly convenient to use the root locus. E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 19 / 27

Time-domain specifications in the complex plane Im Excessive overshoot Good Re Settling time too long E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 20 / 27

Command tracking/disturbance rejection vs. noise rejection r e u y C P n 1 Recall: the sensitivity function S(s) = is the transfer function from 1 + L(s) the reference input r or the output disturbance d to the error e. Hence, if we want small errors to reference inputs, and want to reject disturbances, we need S(s) to be small. The transfer function from the noise input n to the output y is the complementary sensitivity T (s) = L(s). If we do not want the effect of 1 + L(s) the noise to be observed at the output, then we need T (s) to be small. So if we want to reject both disturbances and noise, and want to follow commands well, we need both T (s) and S(s) to be small. But T (s) + S(s) = 1, so they cannot be small at the same time! d E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 21 / 27

Frequency-domain specifications The main point in using frequency domain specifications is exactly to handle such requirements. Typically commands and disturbances act at low frequency, e.g., no more than 10 Hz. Noise is typically a high-frequency phenomenon, e.g., more than 100 Hz. So we can reconcile both command tracking/disturbance rejection AND noise rejection by separating them frequency-wise! Make S(jω) << 1 (hence T (jω) 1 at low frequencies. e.g., ensure that commands are tracked with max 10% error up to a frequency of 10Hz. Make T (jω) << 1 at high frequencies. e.g., ensure that noise is reduced by a factor of 10 at the output at frequencies higher than 100 Hz. E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 22 / 27

Frequency-domain specifications on the Bode plot Frequency-domain specifications are usually expressed in terms of closed-loop frequency response. Can we write them in terms of the open loop frequency response? Indeed we can. Remember that for good command tracking / disturbance rejection, we want S(jω) = 1 + L(jω) 1 to be small at low frequencies, i.e., we want L(jω) to be large at low frequencies. Typically this is written as S(jω) W 1 (jω) < 1 for some function W 1 (jω) that is large at low frequency. This translates to 1 + L(jω) > W 1 (jω), which is approximated as L(jω) > W 1 (jω). This can be seen as a low frequency obstacle on the magnitude Bode plot. E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 23 / 27

Frequency-domain specifications on the Bode plot For good noise rejection, we want T (jω) = L(jω) / 1 + L(jω) to be small at high frequencies. If T (jω) is small, then L(jω) has to be small, and T (jω) L(jω) (at high frequencies). Typically this is written as T (jω) W 2 (jω) < 1 for some function W 2 (jω) that is large at high frequency. This translates to L(jω) < W 2 (jω) 1. This can be seen as a high-frequency obstacle on the Bode plot. E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 24 / 27

Closed-loop bandwidth and (open-loop) crossover The bandwidth of the closed-loop system is defined as the maximum frequency ω for which T (jω) > 1/ 2, i.e., the output can track the commands to within a factor of 0.7. Let ω c be the crossover frequency, such that L(jω c ) = 1. If we assume that the phase margin is about 90, then L(jω c ) = j, and T (jω c ) = 1/ 2. In other words, the (open-loop) crossover frequency is approximately equal to the bandwidth of the closed-loop system. E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 25 / 27

Bode-plot obstacle course Load disturbance attenuation log L iω Robustness ω gc High frequency measurement noise logω E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 26 / 27

Summary of the lecture We discussed how we can write specifications for the closed-loop behavior in terms of: Steady-state error: this has consequences on the necessary DC gain, and/or the number of integrators in the loop transfer function (type of the system); Time-domain specifications: these describe how the closed-loop system, approximated as a second-order dominant system, should behave in time. These specifications are relatively easy to formulate and understand, but do not lend themselves directly to easy design best interpreted on the complex plane/root locus. Matlab can help a lot in meeting these specifications. Frequency-domain specifications: these give a technically sophisticated, powerful set of specifications in terms of ability of the system to follow commands, and to reject disturbances and noise. These specifications apply directly to powerful methods for control design the Bode plot obstacle course. In the next lecture we will finally start seeing how we can design a control system that satisfy all the requirements (closed-loop stability + all the specs we covered in this lecture). E. Frazzoli (ETH) Lecture 10: Control Systems I 24/11/2017 27 / 27