PowerView Modbus Registers (Ver 3.2)

Similar documents
FMS-prep message overview

Cat Electronic Technician 2014A v1.0 Product Status Report 10/23/2016 9:09 AM

SURFACE VEHICLE RECOMMENDED PRACTICE

Motors Automation Energy Transmission & Distribution Coatings. Servo Drive SCA06 V1.5X. Addendum to the Programming Manual SCA06 V1.

A 954 C HD. Technical Description Hydraulic Excavator. Machine for Industrial Applications

MAN-SGY-012-V11 EC 5195 Fairford Electronics Ltd - Synergy Modbus RTU Programming Manual - 22nd February 2016 Page 1 of 59.

DEIF A/S. MTR-2-015, -315, -415, MTR-2F-215 Multi-configurable AC transducer C. Modbus Communication Manual.

MODBUS Protocol for CS141 network card families

Scientific Notation. Part A: Express each of the following in standard form x x x

Exp All technology at operator s service. Suggested Orange peel. Straight boom m. Industrial straight stick 8.00 m RV 600 2,

Useful Formulas and Calculations

AP Physics 1 Summer Assignment (2014)

Gay E. Canough Solar Math. PV Installer s Class: Units and Math

About the Sens it Payload

Applied Fluid Mechanics

Week No. 06: Numbering Systems

Northern Lesson 2 Gear Pump Terminology. Gear Pump 101. Lesson 2: Gear Pump Terminology. When your reputation depends on it!

Electric Vehicle Performance Power and Efficiency

HERU Modbus. Reference Modbus addresses for HERU (Gen 3)

43iQ MODBUS Register Table

Monnit Corporation Version 2.2

STYLE GUIDELINES AND SPECIFICATIONS

Objectives. Power in Translational Systems 298 CHAPTER 6 POWER

Vehicle Propulsion Systems. Electric & Hybrid Electric Propulsion Systems Part III

MOTOR WIRING DATA From National Electrical Code 3 PHASE SQUIRREL CAGE INDUCTION MOTORS 230 Volt 460 Volt Min. # Max. Rating

Mark Redekopp, All rights reserved. Lecture 1 Slides. Intro Number Systems Logic Functions

PREFIXES AND SYMBOLS SI Prefixes you need to know by heart

CALCULUS AP AB Q401.Chapter 5B Lesson 1: Fundamental Theorem (Part 1) Fundamental Theorem of Calculus (Part I)

2.000 Homework # 4: Machine components

Unit Conversions. O Keefe - LBHS

6.111 Lecture # 12. Binary arithmetic: most operations are familiar Each place in a binary number has value 2 n

Physics Energy On This World and Elsewhere - Fall 2013 Problem Set #2 with solutions

Writing Equations 2.1. Addition Subtraction Multiplication Division

Important: This test consists of 16 multiple choice problems, each worth 6.25 points.

Digital Electronic Meters

260A Tractor, Loader & Backhoe S/n & up

station) on the serial port

welcome to physics! 1.1 Mathematics and Physics

Knowledge is Power. Part 1.0 Accurately Measuring Watt Hours/Mile. Ted Lowe 1/16/2009

C 2. The average speed of a car that travels 500 km in 5 hours is a. 10 km/h. b km/h. c. 100 km/h. d. 1,000 km/h

Measurement Set #1. measurement and the accepted value? Show your work!

HEV Optimization. Ganesh Balasubramanian Grad. Berrin Daran Grad. Sambasivan Subramanian Grad. Cetin Yilmaz Grad.

LOGIC CIRCUITS. Basic Experiment and Design of Electronics

MKIII -MB USER S GUIDE 09/18/18. Rev. 3

Sect 4.2 Applications of Ratios and Proportions

Technical Description

Period 1: Review of Physics 103

Chapter 2 SOLUTION 100 = km = h. = h. ft s

PAX2S Modbus Register Table REVISED 2/20/12 LP0894A

Lecture Note 8-1 Hydraulic Systems. System Analysis Spring

ENERGY AND TIME CONSTANTS IN RC CIRCUITS By: Iwana Loveu Student No Lab Section: 0003 Date: February 8, 2004

Exercise 8 - Turbocompressors

Chapter 3. Experimentation and Data Acquisition

Gurley Model A58 Absolute Encoder

BB1 & BB2 INSTALLATION & MAINTENANCE INSTRUCTIONS

ERRATA AND CLARIFICATIONS Fundamentals of Vehicle Dynamics by Thomas D. Gillespie

FRENIC-Ace (C2) (Supplement to RS-485 User's Manual)

FATEK. FBs-1HLC. Precision Load Cell Module. Operation manual V1.1 06/07/2017 FATEK AUTOMATION CORP.

S.Y. Diploma : Sem. III [DE/ED/EI/EJ/EN/ET/EV/EX/IC/IE/IS/IU/MU] Principles of Digital Techniques

WELCOME TO 1103 PERIOD 1

Differential Pressure Sensor

Chapter 3: Fundamentals of Mechanics and Heat. 1/11/00 Electromechanical Dynamics 1

MAINTENANCE AND CALIBRATION REPORT NATIONAL PARK SERVICE GASEOUS POLLUTANT MONITORING NETWORK BADLANDS NATIONAL PARK MAY 10, 2006

1014/15 R Float Volt - - Voltage, L-L, ave of 3 phases 1016/17 R Float Volt - - Voltage, L-N, ave of 3 phases

VISY-Quick Communication Protocol

POE Practice Test - Electricity, Power, & Energy

Chapter 1 Reading Guide Introduction: Matter and Measurement. 1. Chemistry is the study of matter and the it undergoes.

Assignment 4:Rail Analysis and Stopping/Passing Distances

Section 3 Average Speed: Following Distance and Models of Motion

Applied Fluid Mechanics

ULTRA MEASURE MASTER. Conversion Calculator. User s Guide

2.1 Intercepts; Symmetry; Graphing Key Equations

SHOP JOB NUM : COMP SERIAL NUM : COMPARTMENT MODEL : COMP MANUFACTURER : SAMPLE LABEL NUM : FLUID BRAND/WEIGHT : FLUID TYPE : EXT WARR EXPIRE DATE :

Name: 4 sin(2u) 4 sin(1.4)

Robotics Engineering DoDEA Career and Technical Education Simple and Compound Machines

Unit 1 Introduction to Chemistry

Consists of several displays that provide you with useful information. Odometer, Trip meter. distribution monitor. Bluetooth HandsFreeLink

Digital Signal 2 N Most Significant Bit (MSB) Least. Bit (LSB)

GM VOLT PERFORMANCE SIMULATION

MAGPOWR TENSION CONTROL DLCA NET-SLIM. User Manual. Digital Load Cell Amplifier MI 850A358 1 A

ECE260: Fundamentals of Computer Engineering

VTU E-LEARNING NOTES ON:

LOGIC CIRCUITS. Basic Experiment and Design of Electronics. Ho Kyung Kim, Ph.D.

Test Bank for Algebra and Trigonometry 10th Edition by Michael Sullivan

Now, consider the actual molecules reacting with each other:

Introduction to the World of Energy

MEASUREMENTS. Significant Figures

Density. Mass Volume. Density =

ENGR 1100 Introduction to Mechanical Engineering

VELA. Getting started with the VELA Versatile Laboratory Aid. Paul Vernon

Power and Energy Measurement

Motion Chapter 3, Section 1: Distance, Displacement, Speed, Velocity

Energy. This provides a practical measure of the usefulness of a machine. The useful energy transfer in a generator can be represented by:

Review. Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

Technical Data Sheet DPT & DPIT-4005 SERIES DIFFERENTIAL PRESSURE TRANSDUCERS. Features. Description

DYNAMICS AND FRICTION OF VALVE TRAINS

Lesson 17: Synchronous Machines

SAMPLE EXERCISE 1.1 Distinguishing among Elements, Compounds, and Mixtures

NEBB Fundamental Formulas

ISSPRO 3 3/8 Programmable Tachometer High Performance EV Line Part Numbers R5535M, R6535M

Transcription:

PowerView Modbus Registers (Ver 3.2) PowerView Modbus Holding Registers* Register Description Decimal Places Units Range per Bit Resolution Available Value for data not 40001 Accelerator Pedal Position 1 % 0.0 100.0 0.4% FFFFh, 1d 40002 Percent Load 0 % 0 250 1% FFFFh, 1d 40003 Actual Engine Percent Torque 0 % 125 125 1% 7FFFh, 32767d 40004 Engine Speed 0 RPM 0 8031 1 RPM FFFFh, 1d 40005 Trip Distance LSB 0 M 0 326885152 1 Mile FFFFFFFFh, 1d 40006 Trip Distance MSB 40007 Total Vehicle Distance LSB 0 M 0 326885152 1 Mile FFFFFFFFh, 1d 40008 Total Vehicle Distance MSB 40009 Total Engine Hours LSB 1 HRS 0.0 210554048.0 0.1 Hours FFFFFFFFh, 1d 40010 Total Engine Hours MSB 40011 Trip Fuel LSB 1 GAL 0.0 214748400.0 0.1 Gallons FFFFFFFFh, 1d 40012 Trip Fuel MSB 40013 Total Fuel Used LSB 1 GAL 0.0 214748400.0 0.1 Gallons FFFFFFFFh, 1d 40014 Total Fuel Used MSB 40015 Engine Coolant Temperature 0 F 40 410 1 deg. F 7FFFh, 32767d 40016 Fuel Temperature 0 F 40 410 1 deg. F 7FFFh, 32767d 40017 Engine Oil Temperature 0 F 459 3154 1 deg. F 7FFFh, 32767d 40018 Engine Intercooler Temperature 0 F 40 410 1 deg. F 7FFFh, 32767d 40019 Fuel Delivery Pressure 0 PSI 0 145 1 PSI FFFFh, 1d * Slave Active Mode 1110832 08 10 11 Section 78

40020 Engine Oil Level 0 % 0 100 1% FFFFh, 1d 40021 Engine Oil Pressure 0 PSI 0 145 1 PSI FFFFh, 1d 40022 Coolant Pressure 0 PSI 0 72 1 PSI FFFFh, 1d 40023 Coolant Level 0 % 0 100 0.01 FFFFh, 1d 40024 Wheel Base Vehicle Speed 0 MPH 0 155 1 MPH FFFFh, 1d 40025 Fuel Rate 1 G/HR 0.0 848.1 0.1 Gallon/H FFFFh, 1d 40026 Instantaneous Fuel Economy 1 M/G 0.0 295.0 0.1 Mile/Gallon FFFFh, 1d 40027 Average Fuel Economy 1 M/G 0.0 295.0 0.1 Mile/Gallon FFFFh, 1d 40028 Barometric Pressure 0 PSI 0 18 1 PSI FFFFh, 1d 40029 Air Inlet Temperature 0 F 40 410 1 deg. F 7FFFh, 32767d 40030 Boost Pressure 0 PSI 0 72 1 PSI FFFFh, 1d 40031 Intake Manifold Temperature 0 F 40 410 1 deg. F 7FFFh, 32767d 40032 Air Filter Differential Pressure 2 PSI 0 1.80.01 PSI FFFFh, 1d 40033 Exhaust Gas Temperature 0 F 459 3154 1 deg. F 7FFFh, 32767d 40034 Alternator Potential (Voltage) 1 VDC 0.0 3212.7 0.1 Volts FFFFh, 1d 40035 Electrical Potential (Voltage) 1 VDC 0.0 3212.7 0.1 Volts FFFFh, 1d 40036 Battery Potential (Voltage) 1 VDC 0.0 3212.7 0.1 Volts FFFFh, 1d 40037 Transmission Oil Pressure 0 PSI 0 580 1 PSI FFFFh, 1d 40038 Transmission Oil Temperature 0 F 459 3154 1 deg. F 7FFFh, 32767d 40039 Injector Metering Rail 1 Pressure 0 PSI 0 36403 1 PSI FFFFh, 1d 40040 Injector Metering Rail 2 Pressure 0 PSI 0 36403 1 PSI FFFFh, 1d 40041 Fan Drive 0 % 0 100 1% FFFFh, 1d 40042 Auxiliary Temperature 0 F 40 410 1 deg. F 7FFFh, 32767d Page 2

40043 Auxiliary Pressure 0 PSI 0 580 1 PSI FFFFh, 1d 40044 Selected Gear 0 NA 125 125,251 1 Gear, Park 7FFFh, 32767d 40045 Current Gear 0 NA 125 125,251 1 Gear, Park 7FFFh, 32767d 40046 Output Shaft Speed 0 RPM 0 8031 1 RPM FFFFh, 1d 40047 Input Shaft Speed 0 RPM 0 8031 1 RPM FFFFh, 1d 40048 Torque Converter Lockup 0 NA ON/OFF Digital ON/OFF FFFFh, 1d 40049 Machine Hours LSB 1 HRS 0.0 429496729.4 0.1 Hours FFFFFFFFh, 1d 40050 Machine Hours MSB 40051 40100 Future Use 40101 Accelerator Pedal Position 1 % 0.0 100.0 0.4% FFFFh, 1d 40102 Percent Load 0 % 0 250 1% FFFFh, 1d 40103 Actual Engine Percent Torque 0 % 125 125 1% 7FFFh, 32767d 40104 Engine Speed 0 RPM 0 8031 1 RPM FFFFh, 1d 40105 Trip Distance LSB 0 Km 0 526385120 1 Kilometers FFFFFFFFh, 1d 40106 Trip Distance MSB 40107 Total Vehicle Distance LSB 0 Km 0 526385120 1 Kilometers FFFFFFFFh, 1d 40108 Total Vehicle Distance MSB 40109 Total Engine Hours LSB 1 HRS 0.0 210554048.0 0.1 Hours FFFFFFFFh, 1d 40110 Total Engine Hours MSB 40111 Trip Fuel LSB 1 L 0.0 214748352.0 0.1 Liters FFFFFFFFh, 1d 40112 Trip Fuel MSB 40113 Total Fuel Used LSB 1 L 0.0 214748352.0 0.1 Liters FFFFFFFFh, 1d Page 3

40114 Total Fuel Used MSB 40115 Engine Coolant Temperature 0 C 40 210 1 deg. C 7FFFh, 32767d 40116 Fuel Temperature 0 C 40 210 1 deg. C 7FFFh, 32767d 40117 Engine Oil Temperature 0 C 273 1734 1 deg. C 7FFFh, 32767d 40118 Engine Intercooler Temperature 0 C 40 210 1 deg. C 7FFFh, 32767d 40119 Fuel Delivery Pressure 0 kpa 0 1000 1 Kilopascals FFFFh, 1d 40120 Engine Oil Level 0 % 0 100 1% FFFFh, 1d 40121 Engine Oil Pressure 0 kpa 0 1000 1 Kilopascals FFFFh, 1d 40122 Coolant Pressure 0 kpa 0 500 1 Kilopascals FFFFh, 1d 40123 Coolant Level 0 % 0 100 1% FFFFh, 1d 40124 Wheel Based Vehicle Speed 0 Km/H 0 250 1 km/hour FFFFh, 1d 40125 Fuel Rate 1 L/HR 0.0 3212.7 0.1 Liters/Hour FFFFh, 1d 40126 Instantaneous Fuel Economy 1 Km/L 0.0 125.4 0.1 km/liter FFFFh, 1d 40127 Average Fuel Economy 1 Km/L 0.0 125.4 0.1 km/liter FFFFh, 1d 40128 Barometric Pressure 0 kpa 0 125 1 Kilopascals FFFFh, 1d 40129 Air Inlet Temperature 0 C 40 210 1 deg. C 7FFFh, 32767d 40130 Boost Pressure 0 kpa 0 500 1 Kilopascals FFFFh, 1d 40131 Intake Manifold Temperature 0 C 40 210 1 deg. C 7FFFh, 32767d 40132 Air Filter Differential Pressure 2 kpa 0 12.5.05 Kilopascals FFFFh, 1d 40133 Exhaust Gas Temperature 0 C 273 1734 1 deg. C 7FFFh, 32767d 40134 Alternator Potential (Voltage) 1 VDC 0.0 3212.7 0.1 Volts FFFFh, 1d 40135 Electrical Potential (Voltage) 1 VDC 0.0 3212.7 0.1 Volts FFFFh, 1d 40136 Battery Potential (Voltage) 1 VDC 0.0 3212.7 0.1 Volts FFFFh, 1d Page 4

40137 Transmission Oil Pressure 0 kpa 0 4000 1 Kilopascals FFFFh, 1d 40138 Transmission Oil Temperature 0 C 273 1734 1 deg. C 7FFFh, 32767d 40139 Injector Metering Rail 1 Pressure 0 MPa 0 250 1 Megapascals FFFFh, 1d 40140 Injector Metering Rail 2 Pressure 0 MPa 0 250 1 Megapascals FFFFh, 1d 40141 Fan Drive 0 % 0 100 1% FFFFh, 1d 40142 Auxiliary Temperature 0 C 40 210 1 deg. C 7FFFh, 32767d 40143 Auxiliary Pressure 0 kpa 0 4000 1 Kilopascals FFFFh, 1d 40144 Selected Gear 0 NA 125 125,251 1 Gear, Park 7FFFh, 32767d 40145 Current Gear 0 NA 125 125,251 1 Gear, Park 7FFFh, 32767d 40146 Output Shaft Speed 0 RPM 0 8031 1 RPM FFFFh, 1d 40147 Input Shaft Speed 0 RPM 0 8031 1 RPM FFFFh, 1d 40148 Torque Converter Lockup 0 NA ON/OFF Digital ON/OFF FFFFh, 1d 40149 Machine Hours LSB 1 HRS 0.0 429496729.4 0.1 Hours FFFFFFFFh, 1d 40150 Machine Hours MSB 40151 40200 Future Use 41001 Number of Sets of Active Fault Codes 0 NA 0 255 1 Fault FFFFh, 1d 41002 Malfunction Indicator Lamp Status 0 NA 0 = OFF 1 = ON 41003 Red Stop Lamp Status 0 NA 0 = OFF 3 = NOT SUPPORTED 1 = ON 3 = NOT SUPPORTED OFF ON NOT SUPPORTED OFF ON NOT SUPPORTED FFFFh, 1d FFFFh, 1d Page 5

41004 Amber Warning Lamp Status 0 NA 0 = OFF 1 = ON 41005 Protect Lamp Status 0 NA 0 = OFF 3 = NOT SUPPORTED 1 = ON 3 = NOT SUPPORTED OFF ON NOT SUPPORTED OFF ON NOT SUPPORTED FFFFh, 1d FFFFh, 1d 41006 Active SPN 1 LSB 0 NA 0 524287 1 FFFFFFFFh, 1d 41007 Active SPN 1 MSB 41008 Active FMI 1 0 NA 0 31 1 FFFFh, 1d 41009 Active Occurrence Count 1 0 NA 0 127 1 FFFFh, 1d 41010 Active SPN 2 LSB 0 NA 0 524287 1 FFFFFFFFh, 1d 41011 Active SPN 2 MSB 41012 Active FMI 2 0 NA 0 31 1 FFFFh, 1d 41013 Active Occurrence Count 2 0 NA 0 127 1 FFFFh, 1d 41222 Active SPN 55 LSB 0 NA 0 524287 1 FFFFFFFFh, 1d 41223 Active SPN 55 MSB 41224 Active FMI 55 0 NA 0 31 1 FFFFh, 1d 41225 Active Occurrence Count 55 0 NA 0 127 1 FFFFh, 1d 41226 43000 Future Use 43001 Number of Sets of Stored Fault Codes 0 NA 0 255 1 Fault FFFFh, 1d 43002 Stored SPN 1 LSB 0 NA 0 524287 1 FFFFFFFFh, 1d 43003 Stored SPN 1 MSB 43004 Stored FMI 1 0 NA 0 31 1 FFFFh, 1d Page 6

43005 Stored Occurrence Count 1 0 NA 0 127 1 FFFFh, 1d 43006 Stored SPN 2 LSB 0 NA 0 524287 1 FFFFFFFFh, 1d 43007 Stored SPN 2 MSB 43008 Stored FMI 2 0 NA 0 31 1 FFFFh, 1d 43009 Stored Occurrence Count 2 0 NA 0 127 1 FFFFh, 1d 43218 Stored SPN 55 LSB 0 NA 0 524287 1 FFFFFFFFh, 1d 43219 Stored SPN 55 MSB 43220 Stored FMI 55 0 NA 0 31 1 FFFFh, 1d 43221 Stored Occurrence Count 55 0 NA 0 127 1 FFFFh, 1d 43222 45000 Future Use PowerView Slave Active Mode* (RS485 Modbus RTU Slave) Modbus Function Codes Supported Code 3 Reading Holding Registers (maximum response: 50 registers) Modbus Exception Codes Supported Code 01 Illegal Function (sent in response to a Master device use of a Function Code other than Code 3) Code 02 Illegal Data Address (sent in response to a Master device query outside of the allowable register range) Code 03 Illegal Data Value (sent in response to a Master device query of more than 50 registers) *PowerView Model PV101 software version Murphy 3.1 & 3.2 Page 7

Page 8