Explosive Screening by Vapour Detection: Operational Aspects

Similar documents
APLICACIÓN DEL SISTEMA TANDEM DMA-MS AL ANÁLISIS ATMOSFÉRICO

Ross McCulloch Arturo Álvaro Carballido

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Screening of pesticides residues by the time of flight analyzer (ToF) : Myth or reality?

Accurate analysis of neptunium 237 in a uranium matrix, using ICP-QQQ with MS/MS

Supporting Information. Use of Mass Spectrometric Vapor Analysis to Improve Canine Explosive Detection Efficiency

Talk Line-up. MassTech, Inc Columbia Gateway Drive Columbia, Maryland (443) Goals for MT Explorer 50 Development

Introduction to GC/MS

Gruznov, Vladimir. Calhoun: The NPS Institutional Archive Monterey, California. Naval Postgraduate School

TANDEM MASS SPECTROSCOPY

Agilent ESI and APCI sources: for polar to non-polar compounds

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai

MASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Selecting an LC/MS Interface Becky Wittrig, Ph.D.

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

Chemistry Instrumental Analysis Lecture 37. Chem 4631

LC-MS Based Metabolomics

Analysis of Polar Metabolites using Mass Spectrometry

Odor Detection and Analysis using GC/SAW znose

Multi-residue analysis of pesticides by GC-HRMS

Introduction to the Q Trap LC/MS/MS System

Introduction. Chapter 1. Learning Objectives

Defining quality standards for the analysis of solid samples

Interface (backside) & Extraction Lens

Highly Sensitive and Rugged GC/MS/MS Tool

SIFT-MS. technology overview

Technical know-how in thermal analysis measurement

Types of Analyzers: Quadrupole: mass filter -part1

Mass Spectrometry in MCAL

WADA Technical Document TD2003IDCR

Powerful Scan Modes of QTRAP System Technology

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

CEE 772 Lecture #27 12/10/2014. CEE 772: Instrumental Methods in Environmental Analysis

CEE 772: Instrumental Methods in Environmental Analysis

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

Introduction to LC-MS

Introduction to Instrumental Detection Technology: IMS and DMS

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

for the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York

Prima PRO Process Mass Spectrometer

Field-Free Atmospheric Ionization: Atmospheric Pressure Chemical Ionization & Electrospray

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE

Agilent 8900 Triple Quadrupole ICP-MS

Product data sheet Palas Nanoparticle measurement system DEMC 2000

Lecture 8: Mass Spectrometry

Use of High Speed/High Resolution Size-Based Chromatographic Separation of Polymeric Mixtures with Offline Infrared Detection

Introduction to Mass Spectrometry (MS)

This document is a preview generated by EVS

Product data sheet Palas U-SMPS 1050 / 1100 / 1200

Real Time On-Site Odor and VOC Emission Measurements Using a znose

Choosing the metabolomics platform

Lecture 8: Mass Spectrometry

Griffin Analytical Technologies

microtof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF

ABI 3200 Q TRAP LC/MS/MS System

Chip-Scale Mass Spectrometers for Portable Gas Analyzers Luis Fernando Velásquez-García. A. I. Akinwande, K. Cheung, and L.-Y Chen.

Accurate, High-Throughput Protein Identification Using the Q TRAP LC/MS/MS System and Pro ID Software

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

Extrel Application Note

MAX300-BIO Bioreactor and Fermentation Gas Analyzer. Providing Solutions for Gas Analysis

High Throughpu[ Separations and Structural Information Achieved with Automated LC/MS. Michael P. Balogh, Matthew J. Dilts Waters Chromatography

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

GC-APCI IMS of Diesel

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

ANNE JUREK. Abstract: soils and are found. in can also with GC/MS. poster. in series. option for. There are problems. analytes. in methanol.

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Hints and Tips for APGC Coupled with Xevo TQ-S for Food and Environmental Analysis


Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Interpretation of Organic Spectra. Chem 4361/8361

Mass Spectrometry. What is Mass Spectrometry?

Agilent ICP-MS. Fundamentals of ICP-MS Analysis and Its Applications for Low Level Elemental Determination in Cannabis

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Mass spectrometry gas phase transfer and instrumentation

Finnigan LCQ Advantage MAX

Thermo Finnigan LTQ. Specifications

Presentation Basic Introduction to Instrumentation Matrix Effects Challenges

MS Goals and Applications. MS Goals and Applications

Analytical Instrumentation

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

Instrumental Analysis

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

THE NEW ROLE FOR LC/MS AND LC/MS/MS IN EXPLOSIVES INVESTIGATIONS. L. Penfold Severn Trent Laboratories, Inc.

Analyst Software. Automatic Optimization Tutorial

Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Determination of urea in ultrapure water by IC-MS/MS

Use of ICP-MS in analysing radioisotopes. Per Roos Risø National Laboratory for Sustainable Energy, Technicial University of Denmark

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

Transcription:

Explosive Screening by Vapour Detection: Operational Aspects G. Fernandez de la Mora SEDET, Boecillo, Spain, gfdelamora@sedet.com November 14 th, 2013 1

ACES OVERVIEW Product: Air Cargo Explosives Screener (ACES), able to screen explosives while cargo is in bulk form, in particular complete trucks at the airport entrance, Technology: Explosives Trace Detection (ETD) in the vapor mode, based on the integration of Differential Thermal Desorbtion (DTD), Secondary Electro Spray Ionization (SESI), Differential Mobility Analysis (DMA), and API Tandem Mass Spectrometry (API MS/MS), Advantages: ACES accomplishes two simultaneous goals: increase security through a higher PoD than current technologies, and reduce screening costs and delays to values well below present operations, Development stage: Equipment in the certification process in EU Nations, Present performance: Minimum RDX detectable alarm: 0.03 ppq (parts per quadrillion), equal to 3 10-17 atm, Company: SEADM, Morpho and CARTIF created in 2008 a Joint venture (SEDET), aimed at development of explosive detection equipments. 2

ACES SOLUTION SEDET has developed an explosive screener for air cargo (ACES), whose aim is to solve problems generated by present legislation, present screening costs, and state-of-the-art technologies. ACES delivers a radical improvement from present explosive screening procedures: 100% of air cargo is inspected at the airport entrance, Screening is done directly on the truck prior to discharge, Screening is completed in a single operation in a few minutes, Screenings costs are many times lower than present-day operations, PoD and FAR improve considerably over present day performances. 3

Advantages of vapor detection Sampling vapors directly from the within the cargo load. No need for swabbing. No need to reach surfaces which might be unsearchable. No reliance on particle events of low probability, High Sensitivity (sub part per quadrillion) and specificity (low false alarm), both rapidly improving as technology develops and experience accumulates, No alternative TSA approved method exists to monitor a complete truck load as a unit, without going through the lengthy and disruptive process of undoing the load and checking the packages one by one, Low global cost, fast analysis associated to whole cargo monitoring, even when relying on a sophisticated detector, Minimizing delays and enabling 100% monitoring of all aerial cargo, 4

ACES operation Cargo vapors trapped in filter Filter is analyzed automatic result is displayed Sampler Analyzer 5

ACES ARCHITECTURE Direct ambient vapor detection (Sniffing) via sampling, desorbing, ionizing, ion Mobility filtering and triple quad mass analyzing Focusing on Air Cargo Explosives Screener (ACES), sniffing the cargo bay by sampling ~1 m 3 of cargo air into a filter, and desorbing the filter into a suitable Analyzer DMA Desorber Triple quadrupole MS Commercial: Sciex s API 5500: 3.4 lpm sample flow Ionizer 6 6

Mobility filter: DMA (Differential mobility analyzer) Uniform flow at velocity U Inlet slit for charged particles of several mobilities Sheath flow Laminarization screens Electric Field E = V DMA /Δ Δ DMA outlet electrode / MS inlet disk MS vacuum interface Mobility analysys Ion path DMA inlet electrode L Exit hole of particles at mobility Z = UΔ 2 /LV DMA To MS One more narrow band filter added in series to triple quadrupole: Same sensitivity and measurement speed, but 50 increase in resolution DMA Resolution: 50-100; DMA transmission >50% Since ions need to be formed at atmospheric pressure, they may as well be used in mobility separation for greater resolving power. DMA may be viewed as a fast ion chromatograph substituting slower conventional chromatographies (LC or GC). DMA developed at SEADM. No alternative true mobility separation device coupled commercially to MS is available Fernández de la Mora et al. US patent 7,855,360, December 2010. Rus et al. IMS-MS coupling a DMA to commercial API-MS systems, Int. J. Mass Spectrom, 298, 30,2010 7

Sensitivity SEDET tests show that explosives hidden in volumes up to 110 m 3 generate vapour pressures which are from 10 4 to 10 7 lower than the saturation value. Taking into account the equilibrium vapour pressure of RDX, an effective Vapour Screener requires a sensitivity of 0.01 ppq. ppm ppb Human limit Dog & IMS limit TRUCK ppt ppq TNT 8

Sensitivity reachable by EVDs (theory) 1 m3 of ambient air contains 2.7 109 molecules of a vapour present at a concentration of 0.1 ppq (10-16 atm). Present technological measurement inefficiencies are as follows: Ionization probability~ 10-3 ; transmission in triple quadrupole~ 10-2 and filter retention ~ 10%, so measurement losses are on the order of 10 6. Therefore, if 1 m 3 is analyzed, around 2,700 ions will be measured for an explosive with an operational vapour pressure of 0.1 ppq (10-16 atm). This number of ions is considerably above the internal equipment noise, we conclude that sensitivity of present MS technology allows detection of vapours at concentrations of 0.1 ppq. 9

False alarms: The resolution problem The real challenge is background noise from zillions of competing species in the atmospheric background. The larger the sensitivity, the greater the number of species with the same mass and the same primary fragment masses as the explosive monitored. Our approach to deal with this challenge is the use of several filters in series, all having relatively high transmission and resolution, all shifting in synchrony from one explosive to the next: Mobility filter (DMA), Triple quadrupole filter Further resolving power is obtained via Differential thermal desorbtion, Following slides will analyze the resolution increase process 10

Differential thermal desorbtion Figure above presents a logarithmic plot of 2 filters, the blue taken from the atmosphere, and the red from EGDN (X-Axis = seconds, Y-Axis = intensity relative to the maximum of each filter). Temperature in the desorber passes through 4 periods (0s-30s, 30s-60s, 60s-100s, 100s-140s), each of them with a higher temperature. It can be seen that the main EGDN interferent found in the atmosphere has a very distinct time profile from EGDN. This characteristic allows efficient separation. 11

Mobility filtering Figure on the right is a plot of an atmospheric analysis; X-Axis is mobility (Volts), Y-Axis is mass (m/z), The Figure presents the filtering capability of the DMA: most species are characterized as a single red dot, well separated from competing species with the same mass or mobility, However, the DMA is not a perfect filter: some ions appear at all mobilities, although at lower intensities than without DMA 12

Mobility spectra Figure above presents a logarithmic mobility spectrum of the NG channel, showing the analysis of 1 filter taken in presence of NG: the Y- axis is signal intensity at the NG mass, and the X-axis is mobility measured in Volts, The left side of the Figure shows the filtering capability of the DMA: a mobility separation of 50V reduces noise by a factor of 50, while signals separated 90V are divided by a factor of 50,000 13

ATMOSPHERIC INTERFERENTS Figure above shows a mobility spectra in the RDX channel, taken from an atmospheric sample (no explosive present), An atmospheric interferent is present, peaking at at lower mobility than the RDX (100 Volts). However, the tail of the interferent reaches the RDX mobility, and consequently a slight signal is detected at the RDX mobility, with the risk of launching a False Alarm, The DMA mobility filtering can be increased through software developments. Latest ACES improvements have aimed at reduction of False Alarms through an enhanced mobility filtering capability. 14

DECONVOLUTION Figure on the right shows a mobility spectra in the TNT channel. Main signal is generated by an atmospheric interferent with a mobility peak 50 Volts above the TNT peak, Intensity level at the TNT mobility (0V) is dominated by the interferent signal. However, deconvolution allows to clearly separate the interferent contribution and the TNT contribution. 15

Timeframe The ACES screener has been operational for over one year, with performances continuously improving, ACES is been evaluated by various EU certification Authorities, Certification is the only pending barrier for commercialization, and is slowly proceeding, Estimated time frame for deployment ~ 1 year 16

End Gonzalo Fernandez de la Mora <gfdelamora@sedet.com> SEDET Parque Tecnologico de Boecillo, parcela 205 47151 Boecillo Spain info@sedet.com www.sedet.com 17