High Resolution Optical Spectroscopy

Similar documents
Experiment 4 Radiation in the Visible Spectrum

Atomic Spectra HISTORY AND THEORY

Physics 476LW Advanced Physics Laboratory Atomic Spectroscopy

Note to 8.13 students:

Laser Raman Spectroscopy: Vibrational Spectrum of CCl 4

EXPERIMENT 14. The Atomic Spectrum of Hydrogen

DAY LABORATORY EXERCISE: SPECTROSCOPY

Any first year text, sections on atomic structure, spectral lines and spectrometers

AS 101: Day Lab #2 Summer Spectroscopy

Laboratory #29: Spectrometer

PHYS General Physics II Lab The Balmer Series for Hydrogen Source. c = speed of light = 3 x 10 8 m/s

The Spectrophotometer and Atomic Spectra of Hydrogen Physics 246

Atomic Spectra. d sin θ = mλ (1)

Higher Physics. Particles and Waves

Experiment 9. Emission Spectra. measure the emission spectrum of a source of light using the digital spectrometer.

THE DIFFRACTION GRATING SPECTROMETER

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Lecture 0. NC State University

Course Details. Analytical Techniques Based on Optical Spectroscopy. Course Details. Textbook. SCCH 211: Analytical Chemistry I

Physics 24, Spring 2007 Lab 2 - Complex Spectra

Chapter 8. Spectroscopy. 8.1 Purpose. 8.2 Introduction

Characterisation & Use of Array Spectrometers

Name Date: Course number: MAKE SURE TA & TI STAMPS EVERY PAGE BEFORE YOU START EXPERIMENT 14. The Atomic Spectrum of Hydrogen

Atomic emission spectra experiment

ACTIVITY 1. Exploring Light from Gases

Experimental Determination of the Mass of a Neutron

Name(s): Date: Course/Section: Spectroscopy

Lab 5: Spectroscopy & the Hydrogen Atom Phy248 Spring 2009

PC1144 Physics IV. Atomic Spectra

Stray Light Rejection in Array Spectrometers

Atomic Spectroscopy. Absorption and Emission Spectra. Lodovico Lappetito. SpettroscopiaAtomica - 15/07/2015 Pag. 1

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Diffraction Gratings, Atomic Spectra. Prof. Shawhan (substituting for Prof. Hall) November 14, 2016

THE MEASUREMENT OF SOLAR ULTRAVIOLET SPECTRAL IRRADIANCE PROBLEMS & SOLUTIONS

Observation of Atomic Spectra

Spectra from transitions in atoms and lighting

Emission Spectrum of Atomic Gases. Prelab Questions

APAS Laboratory { PAGE } Spectroscopy SPECTROSCOPY

hf = E 1 - E 2 hc = E 1 - E 2 λ FXA 2008 Candidates should be able to : EMISSION LINE SPECTRA

Experiment 3 1. The Michelson Interferometer and the He- Ne Laser Physics 2150 Experiment No. 3 University of Colorado

EMISSION SPECTROSCOPY

Physics 126 Practice Exam #4 Professor Siegel

Physics 23 Fall 1998 Lab 4 - The Hydrogen Spectrum

The Emission Spectra of Light

UNIVERSITY OF CALIFORNIA - SANTA CRUZ DEPARTMENT OF PHYSICS PHYS 133 PROFESSOR: SHER. Atomic Spectra. Benjamin Stahl

Spectrum of Hydrogen. Physics 227 Lab

Pre-lab Quiz/PHYS 224. Your name Lab section

Photoluminescence Spectrometer (FLS980)

Lecture 16 Instrumentation for ICP AES-VIII-Instruments

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

Spectroscopy of Various Light Sources: The Interactions between Light and Matter ASTR 170B1, Spring 2017, Lab #2. 1 Introduction.

Optical Spectroscopy of Hydrogenic Atoms

Quantum States and Spectra of Gases

Experiment 24: Spectroscopy

ATOMIC SPECTRA. To identify elements through their emission spectra. Apparatus: spectrometer, spectral tubes, power supply, incandescent lamp.

Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008

4. Dispersion. The index of refraction of the prism at the input wavelength can be calculated using

4. Dispersion. The index of refraction of the prism at the input wavelength can be calculated using

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

where c m s (1)

HYDROGEN SPECTRUM. Figure 1 shows the energy level scheme for the hydrogen atom as calculated from equation. Figure 1 Figure 2

Introduction to FT-IR Spectroscopy

Physics 1C OPTICAL SPECTROSCOPY Rev. 2-AH. Introduction

Chapter 4. Dispersion of Glass. 4.1 Introduction. 4.2 Apparatus

Atomic Spectra: Energy, Light, and the Electron

Some Topics in Optics

The Spectroscopy of Stars

ATOMIC SPECTRA. Objective:

Practical 1P4 Energy Levels and Band Gaps

EXPERIMENT #AM-1A: PRINCIPLES OF GRATING SPECTROMETERS. a. SYSTEM SENSITIVITY CALIBRATION WITH A BLACK BODY SOURCE

Practical 1P4 Energy Levels and Band Gaps

2001 Spectrometers. Instrument Machinery. Movies from this presentation can be access at

Experiment objectives: measure the ratio of Planck s constant to the electron charge h/e using the photoelectric effect.

Physics 30: Chapter 5 Exam Wave Nature of Light

Lab VI Light Emitting Diodes ECE 476

Taking Fingerprints of Stars, Galaxies, and Other Stuff. The Bohr Atom. The Bohr Atom Model of Hydrogen atom. Bohr Atom. Bohr Atom

Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry

high energy state for the electron in the atom low energy state for the electron in the atom

Model Answer (Paper code: AR-7112) M. Sc. (Physics) IV Semester Paper I: Laser Physics and Spectroscopy

MASS ATTENUATION COEFFICIENT OF LEAD

Experiment AM3b: Raman scattering in transparent solids and liquids

Dept. of Physics, MIT Manipal 1

Chemistry 524--Final Exam--Keiderling Dec. 12, pm SES

Optical Spectroscopy and Atomic Structure. PHYS 0219 Optical Spectroscopy and Atomic Structure 1

2. To measure the emission lines in the hydrogen, helium and possibly other elemental spectra, and compare these to know values.

Atomic Emission Spectra

Spectroscopy: Introduction. Required reading Chapter 18 (pages ) Chapter 20 (pages )

THE MICHELSON INTERFEROMETER Intermediate ( first part) to Advanced (latter parts)

Experiment 2. Grating Spectrometer. 2.1 Introduction. References

LC-4: Photoelectric Effect

Protokoll. Grundpraktikum II - Optical Spectroscopy

Hydrogen-Deuterium Mass Ratio

Spectroscopy for planetary upper atmospheres きょくたん

C101-E107B UV Shimadzu UV-VIS-NIR Spectrophotometer

Overview of Spectroscopy

5 Atomic Physics. 1 of the isotope remains. 1 minute, 4. Atomic Physics. 1. Radioactivity 2. The nuclear atom

SPECTROSCOPY: A KEY TO ELEMENTAL IDENTITY

Chemistry 212 ATOMIC SPECTROSCOPY

The Final Exam (Exam 4) will be on FRIDAY MAY 11 From 3 5 PM in LR1 VAN

HYDROGEN SPECTRUM = 2

Transcription:

PHYS 3719 High Resolution Optical Spectroscopy Introduction This experiment will allow you to learn a specific optical technique with applications over a wide variety of phenomena. You will use a commercial spectrometer (a very common piece of equipment in research labs) to obtain the emission wavelengths of particular elements (e.g. mercury, sodium, hydrogen and deuterium) as well as to compare the outputs of gas and solid state lasers. You will be able to analyze the accuracy and precision of this tool by comparing your measured wavelengths with the corresponding accepted values. Experimental Setup Required Equipment Double-monochromator spectrometer SPEX 1404 with a cooled photomultiplier (PMT) detector White lamp 10-mW helium-neon laser 486 nm laser Mercury, sodium and hydrogen-deuterium lamps Ground glass diffuser Neutral density filters The SPEX 1404 is a commercial double grating spectrometer (see Appendix 2). Light enters the first slit, hits a mirror that focuses it (the light) onto a diffraction grating. Light from the diffraction grating hits a second mirror and is focused to the second (internal) slit. The light then hits another mirror, grating and mirror combination and is focused onto the exit slit (Figure 1). Good initial values are 100 microns for entrance and exit slits and 1 mm for the center slit. - With a light source near the entrance slit and no power supplied to the photomultiplier tube (PMT), remove the top of the spectrometer and observe the dial reading at which the slit has its minimum width. Follow the light path through the spectrometer with a white piece of paper. NOTE: The spectrometer was designed for a 1200 groove/mm grating; to enhance resolution we have installed one with 1800 grooves. Hence, the true wavelength at which the grating is interfering constructively is 2/3 the number shown on the counter; conversely the value on the counter is 50% greater than what appears on the screen at the beginning of the scan. Data acquisition for the SPEX spectrometer is done with a Labview program (Fig. 5). The 1

spectrometer is driven with a stepper motor that rotates the gratings. It has a drive unit and a computer interface unit. Both of these need to have power. The spectrometer output is collected with a cooled photomultiplier (PMT) detector whose output is first fed to a preamplifier (Stanford model 440), then to the Stanford model SR 400 Gated Photon Counter and finally to the pc. The Labview program is in a directory c:/labviewvi as well as the desktop. The spectrometer program moves the spectrometer, receives the output from the Photon Counter and stores both in a file as two columns of ASCII. It is claimed that the line width of the HeNe emission spectrum is 1.5 MHz. Unfortunately this is not directly useful in telling you whether the line width is greater or less than the claimed resolution of the system. For any wave it is well known that the product of the wavelength and frequency is its propagation velocity. For the HeNe, calculate the corresponding line width (in wavelength). Is this greater or less than the advertised resolution of the spectrometer? Operation of the spectrometer system is explained in Appendix 1. Experimental Procedure 1) Begin your investigations by dispersing the light from either a helium-neon (He-Ne) laser (wavelength 632.8 nm) or a small mercury lamp (wavelength 546.1 nm). The 10-mW HeNe laser has enough power to damage the preamp, hence use a neutral density filter to reduce this power or diffuse the beam with a ground glass. Observe and plot peak FWHM (Full Width at Half Maximum; Half width ) and signal integrated intensity as a function of slit width. Check wavelength accuracy by comparing to NIST value. 2) The resolution of the spectrometer is claimed to be 0.006 nm and the dispersion to be 0.44 nm/mm of slit width. The latter means that if you have both slits set to 1 mm, you should be able to resolve two peaks that are 0.44 nm apart; if you set the slits to 0.1 mm, you should be able to resolve two peaks 0.04 nm apart, etc. Test this model using the H2-D2 emission as input. - Compare the measured sodium doublet wavelengths with the accepted ones [1]. 3) The hydrogen-deuterium lamp has lines near 656 nm with about 0.1 nm separation. Based on manufacturer s specification for dispersion, estimate the widths of the entrance and exit slits, and the number of steps required to resolve them. Take data to test your estimates; indeed, take spectra as a function of slit width to test the manufacturer s claim. Compare your measured hydrogen and deuterium emission wavelengths with the accepted ones [1]. Is this an awesome piece of equipment or what? Deuterium is an isotope of hydrogen whose nucleus contains one proton and one neutron. In the Balmer experiment your classmates are learning that 1 λ = R ( 1 n2 1 i n2) where R f is the Rydberg constant assuming the nucleus has infinite mass. For the red line in the hydrogen and deuterium spectra n i = 3 and n f = 2. R = me4 3 But this assumes that the ε 0 2 ch 2

nuclear mass is infinite. Accuracy of the calculated wavelength is improved by correcting R with the reduced mass: R H = R / (1 + m e ) where m e is the mass of the electron and m p is m p the mass of the proton. There is an equivalent expression for the reduced mass and corrected Rydberg constant of the deuteron. From the fundamental constants in the Rydberg equation, calculate the theoretical wavelength in the hydrogen spectrum. From your measurements of the difference between the emission wavelengths of hydrogen and deuterium, calculate the mass of the neutron. Compare your result to the published value. To how many significant digits do you expect your result to be correct? Is there a significant discrepancy between your result and the published value? Is this cool or what? Are we having fun yet? 4) This class is about testing models. What model(s) can you test with the equipment you have been given? 5) A huge fraction of the work to date has centered on error analysis. What are the sources of error in your observations? What are your estimates of the errors in your measurements? References [1] http://physics.nist.gov/physrefdata/asd/lines_form.html. [2] J.D. Ingle and S.R. Crouch, Spectrochemical Analysis, Prince-Hall, NJ (1988), Section 2-4. [3] G. Brooker, Modern Classical Optics, Oxford University Press, NY (2003), Section 4.9.5. 3

Appendix 1: Spectrometer operation Fig. 1: Spex 1404 spectrometer layout Fig. 2: Preamplifier and thermoelectric cooler for PMT (PhotoMultiplier Tube) 4

Fig. 3: PMT high voltage supply and gated photon counter Fig. 4: Desktop on system control computer 5

Fig. 5: Labview interface. Lock-in amplifier/single photon counting switch, scanning parameter input and filename entry option locations Fig. 6: Popup showing where the software thinks the spectrometer gratings are set. Check the value displayed on the side of the spectrometer to assure that it agrees with what the software shows. Appendix 2: Monochromators and spectrometers (generic information originally 6

intended for the Photoelectric experiment) - How does the monochromator work? Remove the lid and look at the inner workings, with the room lights off but the lamp on. Follow the beam path with a piece of paper. DO NOT, UNDER ANY CIRCUMSTANCES WHATSOEVER, TOUCH THE GRATINGS OR THE MIRRORS. - What is the difference between a monochromator and a spectrometer? They are basically the same piece of equipment but used differently. A monochromator selects a narrow distribution of wavelengths/energies/frequencies from a broad distribution for use in some application. The grating is adjusted to a fixed angle, which gives the desired output wavelength/energy/frequency. It is a light source of adjustable, nominally monochromatic light; i.e. the output is light of a known wavelength. The output of a spectrometer is information: a detector is attached to the exit slit of the same piece of equipment and the grating is scanned through an angle. As the grating is scanned in angle (in time), the various wavelengths in the spectrum of light incident on the entrance slit are scanned across the exit slit and detector [2]. By correlating the intensity of light incident on the exit slit to the grating angle (as a function of the same time), one can back-calculate the intensity of light incident on the entrance slit as a function of its wavelength/energy/frequency. The spectrometer tells you the intensity distribution of the emission from some light source. The SPEX 1404 is a double-monochromator spectrometer. It has two monochromators in series in order to reject the unwanted and intense incident light ( stray light ) into its output [3]. 7

Appendix 3. Spex 1404 manufacturer s specifications 8