ANALYSIS OF BASIC COMPOUNDS

Similar documents
viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

[ Care and Use Manual ]

IN QUALITATIVE ANALYSIS,

Basic Principles for Purification Using Supercritical Fluid Chromatography

Reports of the Death of Fully Porous Particles are Greatly Exaggerated

ultimate efficiency unleashed [ Cortecs 1.6 µm columns ]

1.7µm Fortis C18 UHPLC Columns

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

Gemini-NX Performance paired with Axia Technology

UPLC Method Development and Validation

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

penta-hilic UHPLC COLUMNS

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

DEMONSTRATING SUPERIOR LINEARITY: THE ACQUITY UPLC PHOTODIODE ARRAY DETECTOR

Your Reversed Phase Method

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

HILIC Method Development in a Few Simple Steps

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT

Reversed Phase Solvents

Implementation of Methods Translation between Liquid Chromatography Instrumentation

UPC 2 Strategy for Scaling from Analytical to Preparative SFC Separations

Peptide Isolation Using the Prep 150 LC System

ApplicationNOTE Abstract

Preparative Chromatography with Improved Loadability

penta-hilic UHPLC COLUMNS

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Routine MS Detection for USP Chromatographic Methods

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

[ Care and Use Manual ]

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

Dilution(*) Chromatography

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

LC Technical Information

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Transferring Yesterdays Methods to Tomorrows Technology: The Evolution from HPLC to UPLC TM

Simultaneous Determination of Pharmaceutical Peptides and Acetate Counterions by HPLC Using a Mixed-Mode Weak Anion-Exchange Column

Biochemistry. Biochemical Techniques HPLC

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

Successfully Scaling and Transferring HPLC and UPLC Methods

A C18 Silica Column With Exceptional Temperature and ph Stability

2017 Source of Foreign Income Earned By Fund

surpass all possibilities [ Cortecs 2.7 µm columns ]

C18 Column. Care & Use Sheet

Easy Method Transfer from HPLC to RSLC with the Dionex Method Speed-Up Calculator

LC and LC/MS Column Selection Flow Chart

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Quick Guide QUICK GUIDE. Activity 1: Determine the Reaction Rate in the Presence or Absence of an Enzyme

Hypersil BDS Columns TG 01-05

Solvent Flexibility for Size-Based Polymer Analysis Using the Advanced Polymer Chromatography (APC) System

[ Care and Use Manual ]

Liquid Chromatography

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Appendix B: Detailed tables showing overall figures by country and measure

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods

Kromasil Eternity Designed for long life. For use in HPLC and UHPLC

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Kromasil Eternity Designed for long life

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

[ CARE AND USE MANUAL ] XSELECT HSS XP 2.5 µm COLUMNS I. INTRODUCTION CONTENTS I. INTRODUCTION II. GETTING STARTED III. COLUMN USE

Bringing uhplc Performance to the Separation of Peptides

OBSERVATIONS ON THE WETTING OF REVERSED-PHASE HPLC PACKINGS

Kromasil Eternity Designed for long life

[ a ppl ic at ion no t e ]

UPLC for Synthetic Peptides: A User`s Perspective

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

Impact of Pore Exclusion on Reversed-Phase HPLC Column Performance

1.7µm Fortis UHPLC Columns

Expediting Achiral SFC Method Development Using a Multi-Channel SFC System with MS Detection

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

Effects of Aqueous Sample Content and Aqueous Co-Solvent Composition on UPC 2 Separation Performance

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Small Molecule Selectivity Sampler

Multi-Channel SFC System for Fast Chiral Method Development and Optimization

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Part 2. Overview of HPLC Media

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Transcription:

COMPARISON OF Fully AND Superficially POROUS PARTICLE COLUMNS FOR THE ANALYSIS OF BASIC COMPOUNDS Kenneth J. Fountain, Jane Xu, Zhe Yin, Pamela C. Iraneta, Diane M. Diehl Waters Corporation GOAL Compare the performance of fully and superficially porous (fused-core ) particle columns. INTRODUCTION Since the introduction of high-performance liquid chromatography (HPLC) nearly years ago, many improvements have been made to column stationary phases to achieve faster, more efficient separations. There are several ways of engineering a column in order to achieve these goals, including: increasing packed-bed homogeneity, decreasing intra-particle volume, narrowing particle-size distribution, and decreasing the diffusion distance this can be achieved, in part, by using smaller particles. It is also thought that this may be achieved by using superficially porous particles that have a solid silica core and porous outer shell []. HPLC columns containing superficially porous (sometimes called fused-core) particles have recently gained increasing attention. Though this technology is not entirely new, it has been improved to the point where rapid, highly efficient separations can be achieved for some applications. For neutral compounds,.7-µm superficially porous particle columns were reported to have 7-8% of the efficiency of sub- µm, fully porous particles, and approximately -6% lower backpressure []. However a vast majority of the pharmaceutical drug compounds manufactured today are basic in chemical nature, so determining their chromatographic behavior on both fully and superficially porous particle columns has practical implications. Unlike neutral compounds, bases are ionized at low ph, and secondary interactions can occur with the stationary phase, causing asymmetric peak shape and efficiency loss. The goal of this work is to investigate the differences in separation performance between fully and superficially porous particle columns for routine analysis of basic pharmaceutical drug compounds. Major parameters of comparison are chemical stability, peak capacity ( ), and column efficiency at different mass loads. EXPERIMENTAL For chemical stability and mass loading studies, experiments were performed on an ACQUITY UPLC system equipped with an ACQUITY UPLC PDA detector. To determine chemical stability, a sample test mixture containing µg/ml methyl paraben (prepared in H O) was injected every minutes and retention time was monitored. The mobile phase was.% TFA in H O. Flow rate was. ml/min. The column was heated to 6 C. Injection volume was µl. UV detection was performed at nm using a sampling rate of Hz (fast filter time constant). The effect of mass load on column efficiency was determined by injecting solutions containing different concentrations of diphenhydramine and amitriptyline (both basic analytes). The isocratic mobile phase was either % ACN, 68% mm ammonium formate, ph.7 or 7% ACN, % mm ammonium bicarbonate, ph. Flow rate was. ml/min. Column temperature was C. Injection volume was µl, and UV detection was performed at either nm (amitriptyline) or nm (diphenhydramine). Sampling rate was Hz with no time constant. Samples were prepared in the corresponding mobile phase, and thiourea was used as the V marker. The peak capacity ( ) of fully and superficially porous particle columns was compared with a standard mixture of basic compounds, and also with a forced degradation sample (glimepiride). These comparisons were all performed on an Alliance 69 Separations Module equipped with a 998 PDA detector. Column dimensions used for these experiments were.6 x 7 mm. For separation of the standard mixture of bases, mobile phase A was mm ammonium formate, ph. Mobile phase B was % ACN. The gradient was from 6% B in min, hold at 6% B for min, reset ( min total run time). The flow rate was ml/min and the column temperature was C. Injection volume was µl, and UV detection was at 6 nm ( Hz sampling rate, normal filter response). Peak capacity was measured using the peak width at.% peak height (σ).

For the forced degradation sample of glimepiride, mobile phase A was.% TFA in H O. Mobile phase B was.% TFA in ACN. The gradient was from -9% B in.6 min, hold at 9% B for.8 min, (7 min total run time). The flow rate was.9 ml/min and the column temperature was maintained at C. Injection volume was 8 µl, and UV detection was at nm ( Hz, normal filter time constant). The degradation sample was generated by first degrading two separate. mg/ml solutions of glimepiride (in MeOH) with.n NaOH or.n HCl at 6 C for 9 min, respectively. The solutions were cooled, combined, and µl of glacial acetic acid was added to neutralize the ph. RESULTS Chemical Stability In order to improve the peak shape and retention of basic compounds in RP-HPLC, ion-pairing reagents such as TFA are used. However, these additives can potentially limit the lifetime of RP columns due to ligand hydrolysis. Therefore, the low ph stability of fully porous silica (SunFire ), fully porous ethylene-bridged hybrid (XBridge ), and superficially porous silica (HALO ) particle columns was measured (Fig. ). Methyl paraben retention was monitored over the course of hours in.% TFA (ph ~.) at elevated temperature. % Change in Retention Time 6 7 6 8 min Exposure Time in.% Aqueous TFA at 6 C XBridge C 8. µm.9 % SunFire C 8. µm.7 % HALO C 8.7 µm 7.8 % Figure. Low-pH chemical stability of XBridge C 8, SunFire C 8, and HALO C 8. Methyl paraben retention was corrected for system retention time. Column dimensions were. x mm. It is clear that the HALO column is the least stable at low ph. On this column, methyl paraben retention decreases by almost % over the course of the test, most likely due to gradual loss of the C 8 ligand. Retention loss is also observed on the SunFire column, but to a much lesser extent. The SunFire column is almost three times more stable than the HALO column, due to difunctional bonding of the C 8 ligand to the particle surface. Negligible retention loss was seen on the XBridge column, due to the fact that it contains hybrid particles with trifunctional bonding. These ethylene-bridged hybrid (BEH) particles have also been shown to have excellent high ph stability [,]. Peak Capacity The ideal separation conditions for basic compounds involve high ph mobile phases. At high ph, bases are not ionized, and do not undergo secondary interactions with residual silanols on the stationary-phase surface. However, traditional silica-based stationary phases are not capable of routine operation at ph values >7 without severely compromising the column lifetime (<- injections). As a result, chromatographers are limited to using silica-based RP columns at low ph conditions. Figure shows the comparison between XBridge, SunFire, and HALO columns for the separation of a standard mixture of basic compounds in a low ph mobile phase.

The peak capacity for XBridge and HALO columns are nearly identical. The SunFire column has almost 6% higher peak capacity than the HALO column under the same conditions, indicating better peak shape for basic compounds at low ph. It is also interesting to note that the SunFire column gives slightly different selectivity (reversal in elution order of diltiazem and prednisone), that may be useful during HPLC method development..8.6...8.6.. XBridge C8 = 9 SunFire C8 = 99.6.. 6 7 XBridge C8. µm PC = 67.8.6.. HALO C8 = 88 6 7 8 9 min.6.. 6 7 SunFire C8. µm PC = Figure. Separation of a glimepiride forced-degradation sample on XBridge, SunFire, and HALO columns. For conditions, see text on p.. Effect of Mass Load on Column Efficiency.6.. 6 7 HALO C8.7 µm PC = 7 6 7 8 9 min Figure. Peak capacity comparison for a standard mixture of basic compounds. Peaks: () uracil, () pindolol, () quinine, () labetalol, () prednisone, (6) diltiazem, (7) amitriptyline. For conditions [ph ], see text on p.. Another comparison of peak capacity between these three columns was performed using a forced degradation sample (Fig. ). Again, the HALO column has the lowest peak capacity for separation of low-level impurities in the degraded sample. The XBridge column has the highest peak capacity (>% higher than the HALO column), and the SunFire column is the most retentive. This example shows that there is no benefit to using the superficially porous Halo column instead of the fully porous,. μm XBridge or SunFire columns for real-life separations. Maximizing the amount of sample that may be loaded onto an HPLC column is important for preparative purification and stability indicating methods, where a large amount of an active pharmaceutical ingredient (API) is injected in order to detect low-level impurities in the sample. As more material is loaded onto the column, the peak becomes wider, thereby decreasing column efficiency and resolution. The performance of fully and superficially porous particle columns was evaluated as a function of mass load for two basic compounds at low ph. Figure shows the efficiency for amitriptyline on XBridge, SunFire, and HALO columns.

6. XBridge TM C 8. µm Low ph. Efficiency (N). XBridge C8. µm, ph XBridge C8. µm, ph.7 SunFire C8. µm, ph.7 HALO C8.7 µm, ph.7. On-Column Mass Load:. -. µg... min.......6.7.8.9. On-Column Mass Load (µg).. XBridge TM C 8. µm High ph Figure. Efficiency of fully and superficially porous columns as a function of mass load. Amitriptyline was the test probe. Efficiency was calculated using the peak width at.% peak height (σ). Data were corrected for system band spreading..8.6 At low ph, the HALO column has the lowest efficiency at all mass loads. This is expected, in large part because it is superficially porous and has the lowest surface area ( m /g). At lower mass loads, the XBridge column has slightly higher efficiency than the SunFire column. As mass load increases, however, the XBridge and SunFire columns show similar performance. At the highest mass load tested at low ph, both XBridge and SunFire columns had ~ x higher efficiency than that of the HALO column. As described earlier, the best conditions for analyzing basic compounds by HPLC are with high ph mobile phases. While it is not possible to use mobile phases with ph values above 7 with silica-based stationary phases (i.e., SunFire and HALO columns), it is possible to operate XBridge columns at ph values up to with exceptional lifetime. Figure shows the difference in peak shape and signal intensity for amitriptyline run at low and high ph on an XBridge C 8 column... On-Column Mass Load:. -. µg... min Figure. Analysis of amitriptyline in low and high ph mobile phases on an XBridge C 8 column. Peak shape is dramatically improved at high ph due to the lack of secondary interactions of the basic solute with the stationary phase under these conditions. As a result, signal intensity for amitriptyline is more than x higher than that at low ph mobile phases. Finally, no significant deterioration in column efficiency was observed at high ph, even for higher mass loads (Fig., uppermost curve, black squares). Under these circumstances, the efficiency for the XBridge column was more than x higher than that at low ph. The trends shown in Figures and were similar for diphenhydramine (data not shown).

CONCLUSIONS The benefits of using appropriate fully porous particle HPLC columns with comparable particle size clearly outweigh those of using current superficially porous (fused-core) particle columns for the analysis of basic compounds. Among the columns examined in this study, the fully porous particle columns have superior chemical stability at low ph when compared to that of the superficially porous particle column. Under gradient conditions, both XBridge and SunFire columns have higher peak capacities than the HALO column for a standard mixture of bases, as well as a forced degradation sample of glimepiride. Finally, XBridge and SunFire columns exhibit an approximately -fold higher efficiency than that of HALO columns at low ph. At high ph, XBridge columns demonstrated a -fold increase in column efficiency over that at low ph at the same mass loads. This dramatic advantage of hybrid particle technology is most important for increasing throughput in preparataive HPLC separations and as well as increasing capacity when developing superior stability indicating methods for impurity detection in APIs. REFERENCES. J.J. DeStefano, T.J. Langlois, J.J. Kirkland, J. Chromatogr. Sci. 6 (8).. J.M. Cunliffe, T.D. Maloney, J. Sep. Sci. (7).. K.J. Fountain, D. Morrison, D.M. Diehl, J. Martin, LCGC: The Application Notebook, (June ).. K.D. Wyndham, J.E. O Gara, T.H. Walter, K.H. Glose, N.L. Lawrence, B.A. Alden, G.S. Izzo, C.J. Hudalla, P.C. Iraneta, Anal. Chem. 7 () 678. Austria and European Export (Central South Eastern Europe, CIS and Middle East) 877 8 7, Australia 6 99 777, Belgium 76, Brazil 9 788, Canada 8 7 x, China 86 886 8899, CIS/Russia 7 9 6 7, Czech Republic 67 8, Denmark 6 9 88, Finland 8 9 69 688, France 8 7, Germany 9 696 6, Hong Kong 8 9 6 8, Hungary 6 86, India and India Subcontinent 9 8 87 9, Ireland 8, Italy 6 98, Japan 8 7 79, Korea 8 8 7, Mexico 86, The Netherlands 76 8 7, Norway 7 6 8 6, Poland 8 8 Puerto Rico 787 77 8, Singapore 6 67, Spain 9 6 9, Sweden 6 676 7, Switzerland 6 676 7, Taiwan 886 898, United Kingdom 8 8 6 All other countries: Waters Corporation U.S.A. 8 78 / 8 7 Waters, The Science of What s Possible, ACQUITY UPLC, Alliance, SunFire, Corasil and XBridge are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 8 Waters Corporation. Printed/Produced in the U.S.A. December 8 78EN VW-PDF Waters Corporation Maple Street Milford, MA 77 U.S.A. T: 8 78 F: 8 87 99 www.waters.com