Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Similar documents
Varius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

3VT4 Molded Case Circuit Breakers up to 1000 A

Issued August DATA SHEET. 3VT3 MCCB up to 630 A

5SP and 5SY Supplementary Protection UL 1077

Thermal-Magnetic Circuit Breaker 2210-S2..

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards

Thermal-Magnetic Circuit Breaker 2210-T2...

Miniature Circuit Breaker

TeSys circuit-breakers

Semiconductor (AC) fuses

NH fuse-links gg 500VAC double indicator/live tags size 000, 00, 0, 1, 2, 3

Thermal-Magnetic Circuit Breaker 2210-S2..

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A

MCB NB1-63H Miniature Circuit Breaker

Non-Contact Safety Systems CMS

Thermal-Magnetic Circuit Breaker 2210-S2..

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2...

C60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Semiconductor (AC) fuses

C120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka

Semiconductor (AC) fuses

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN

Modular contactors for installation into distribution

X T O B P 1 6 B C 1 S

SIRCOVER Manual transfer switches from 125 to 3200 A

UL 1077 DIN Rail Supplementary Protectors

BETA Protecting Miniature Circuit Breakers

General characteristics, Products

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics

90 MCB range Modular circuit breakers for circuit protection

Impedance relay and protection assemblies

Semiconductor (AC) fuses

7S SERIES. Relay module with forcibly guided contacts 6 A 7S S /0310 7S

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION

ATyS Automatic and remotely operated transfer switches from 125 to 3200 A

PRODUCT SPECIFICATION 1 SCOPE APPLICABLE STANDARDS CATALOG NO. STRUCTURE..3 4 CONNECTOR SHAPE, DIMENSIONS AND MARTERIALS..

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

MOULDED CASE CIRCUIT BREAKERS BL1000S

Single Phase Motors Technical Datasheets

TeSys enclosed starters 2

Periodic Inspection and Testing of Electrical Installations Sample Test ( ) Version 1.3 July 2018

PHOENIX CONTACT - 04/2016. Features

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

440V 500V V / / /2 12.

Miniatur Circuite Breakers (MCB)

Redline Unibis : the solution Circuit protection

Power capacitors in general

Film Capacitors. EMI suppression capacitors. Date: June 2018

F F FAULT CURRENT Prospective. 1. Introduction. 2. Types of fault conditions

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

2-2. Bulletin 140M Motor Protection Circuit Breakers. Product Overview. Table of Contents. Standards Compliance. Certifications. General Information

TeSys DF IEC-Type Fuseholders

High Precision Thick Film chip resistors. Size 1206, 0805, 0603, 0402, 0201

Performance. Standards. Technical data

SION Lateral 3AE6 Vacuum Circuit Breaker with Lateral Operating Mechanism

1..LOW VOLTAGE POWER CAPACITORS MKP (CYLINDRICAL) 2 2..PPM / MKP TECHNOLOGY 2 3..OPERATING CONDITION Voltage Ambient temperature

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Installation Contactors ISU-xxx ISM-xxx

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AC axial compact fan

Surface Mount Multilayer Ceramic Chip Capacitors for Safety Certified Applications

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

FEATURES APPLICATIONS DESCRIPTION QUICK REFERENCE DATA. PILKOR components

8 Installation Equipment

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

SS V Subminiature, radial leaded, time-delay fuses

Selecting the current rating for equipment

MKV AC Capacitors Damping B High dielectric strength High peak-current capability Especially suitable for snubber circuits

Blocks and Holders POWR-BLOKS. Connectors. Ampere Ratings. Ordering Information. Applications. Specifications. Distribution/Splicer Blocks and Covers

Semiconductor (AC) fuses

Technical catalogue SmiSSline electrical protective devices in a system

Power Resistor for Mounting onto a Heatsink Thick Film Technology

Imformation of C091D series

THF / 1SCC330001M THF 1S1 C

CDS. high density spring connection

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

TeSys contactors. TeSys D contactors. 690 V on a and c

Operating instructions Pressure sensor PN / / 2007

Universal limit switches

Aluminum Electrolytic Capacitors Power Long Life Snap-In

Performance. Standards. Technical data

EX-CONTROL AND DISTRIBUTION SYSTEMS

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

Three Core XLPE/LSF/SWA/LSF Power Cable

Analogue Meters CQ2x07 series

DATA RACK BUSBAR. Data Rack Busbar Systems A.

CNY17 Series. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. VDE Standards.

Power Resistor for Mounting onto a Heatsink Thick Film Technology

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Pressure transmitters for industrial applications MBS 32 and MBS 33

Transcription:

SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size 000 000 00 00 Utilization category of the fuse-link gg, am gg gg, am gg Use Fuse switch-disconnectors FH000.., FH00.. FH00.. Fuse switch-disconnectors of vertical design FSD00.. Fuse-rails FSR00.. Fuse-bases SPB00, SPB00, SPF00 Accessories Signal contact VL0 Signalling of fuse-link state MD-M Disconnecting link ZP000 Replacement handles DPH, DP, DPM E

SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA PHNA PNA PHNA Rated current I n up to 0 A up to 00 A up to 00 A up to A Rated voltage U n AC 00 V, 90 V 90 V 00 V, 90 V 90 V DC 0 V, 0 V 0 V 0 V, 0 V 0 V Fuse-link size Utilization category of the fuse-link gg, am gg gg, am gg Use Fuse switch-disconnectors FH.. FH.. Fuse switch-disconnectors of vertical design FSD.. FSD.. Fuse-rails FSR.. FSR.. Fuse-bases SPB, SPB, SPF SPB, SPB, SPF Accessories Signal contact VL0 Signalling of fuse-link state MD-M Disconnecting links ZP ZP Replacement handles DPH, DP, DPM E

SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA / PN PHNA PNa PHNa Rated current I n up to 0 A up to 00 A up to 00 A up to 000 A Rated voltage U n AC 00 V, 90 V 90 V 00 V 90 V DC 0 V, 0 V 0 V 0 V 0 V Fuse-link size a a Utilization category of the fuse-link gg, am gg gg gg Use Fuse switch-disconnectors FH.. LTLa Fuse switch-disconnectors of vertical design FSD.. - Fuse-rails FSR.. - Fuse-bases SPF - Accessories Signal contact VL0 Signalling of fuse-link state MD-M Disconnecting links ZP.. TMa.. Replacement handles DPH, DP, DPM - E

PNA FUSE-LINKS WITH BLADE CONTACTS PNA High limiting and breaking capacity. Low power losses. The fuse-links do not contain harmful substances according to the RoHS Regulation (cadmium, lead and other). For use in fuse switch-disconnectors, fuse-rails and fuse-bases Utilization category gg (black print) for protection of lines, cables and other equipment against overload and short-circuit. Utilization category am (green print) for protection of motors, overcurrent relays, contactors and similar devices only against short-circuit. Fuse-links with blade contacts PNA000 Utilization category gg Utilization category am I n Type Order Power losses Weight Type Order Power losses Weight Package [A] code [W] [kg] code [W] [kg] [pcs] PNA000 A gg OEZ:077.0 0. PNA000 A am OEZ:09 0.8 0. PNA000 A gg OEZ:078.00 0. PNA000 A am OEZ:09 0. 0. PNA000 A gg OEZ:079.70 0. PNA000 A am OEZ:09 0.8 0. 0 PNA000 0A gg OEZ:080. 0. PNA000 0A am OEZ:09.0 0. PNA000 A gg OEZ:08.0 0. PNA000 A am OEZ:09. 0. PNA000 A gg OEZ:08.0 0. PNA000 A am OEZ:097. 0. PNA000 A gg OEZ:08.9 0. - - - - 0 PNA000 0A gg OEZ:08. 0. PNA000 0A am OEZ:098.0 0. 0 PNA000 0A gg OEZ:08.80 0. PNA000 0A am OEZ:099. 0. PNA000 A gg OEZ:08.0 0. PNA000 A am OEZ:000. 0. 80 PNA000 80A gg OEZ:087.80 0. PNA000 80A am OEZ:00. 0. 0 PNA000 0A gg OEZ:088.9 0. PNA000 0A am OEZ:00. 0. PNA000 A gg OEZ:089 7.0 0. - - - - PNA000 A gg ) OEZ:090 9.00 0. - - - - Fuse-links with blade contacts PNA00 ) U n = AC 00 V Utilization category gg Utilization category am I n Type Order Power losses Weight Type Order Power losses Weight Package [A] code [W] [kg] code [W] [kg] [pcs] 0 - - - - PNA00 0A am OEZ:0.9 0.0 PNA00 A gg OEZ:0 8.9 0. PNA00 A am OEZ:0. 0.0 PNA00 A gg OEZ:0. 0. PNA00 A am OEZ:07 9. 0.0 Fuse-links with blade contacts PNA Utilization category gg Utilization category am I n Type Order Power losses Weight Type Order Power losses Weight Package [A] code [W] [kg] code [W] [kg] [pcs] PNA A gg OEZ:08. 0.0 - - - - 0 PNA 0A gg OEZ:09.7 0.0 - - - - PNA A gg OEZ:00.80 0.0 - - - - PNA A gg OEZ:0.0 0.0 - - - - PNA A gg OEZ:0.0 0.0 - - - - 0 PNA 0A gg OEZ:0. 0.0 - - - - 0 PNA 0A gg OEZ:0. 0.0 - - - - PNA A gg OEZ:0.00 0.0 PNA A am OEZ:0.0 0.0 80 PNA 80A gg OEZ:0 7.0 0.0 PNA 80A am OEZ:0.9 0.0 0 PNA 0A gg OEZ:07 8. 0.0 PNA 0A am OEZ:0.8 0. PNA A gg OEZ:08.70 0.0 PNA A am OEZ:0 8. 0. PNA A gg OEZ:09.0 0.0 PNA A am OEZ:07. 0. 00 PNA 00A gg OEZ:00.00 0. PNA 00A am OEZ:08. 0. PNA A gg OEZ:0. 0. - - - - 0 PNA 0A gg OEZ:0 8.0 0. PNA 0A am OEZ:09 8.0 0. Fuse-links with blade contacts PNA Utilization category gg Utilization category am I n Type Order Power losses Weight Type Order Power losses Weight Package [A] code [W] [kg] code [W] [kg] [pcs] PNA A gg OEZ:08.0 0. - - - - 0 PNA 0A gg OEZ:087.0 0. - - - - 0 PNA 0A gg OEZ:088.9 0. - - - - PNA A gg OEZ:089.90 0. - - - - 80 PNA 80A gg OEZ:090.80 0. - - - - 0 PNA 0A gg OEZ:09 7.8 0. - - - - PNA A gg OEZ:09 9.80 0. PNA A am OEZ:000 8. 0. PNA A gg OEZ:09.00 0. PNA A am OEZ:00. 0. 00 PNA 00A gg OEZ:09.90 0. PNA 00A am OEZ:00. 0. PNA A gg OEZ:09.0 0. - - - - 0 PNA 0A gg OEZ:09 7.00 0. PNA 0A am OEZ:00 8.0 0. PNA A gg OEZ:097.0 0. PNA A am OEZ:00. 0.8 0 PNA 0A gg OEZ:098.00 0. - - - - 00 PNA 00A gg OEZ:099 9.00 0. PNA 00A am OEZ:00 0.8 0.8 E

PNA FUSE-LINKS WITH BLADE CONTACTS PNA Fuse-links with blade contacts PNA In [A] 00 0 0 00 00 0 Type PNA 00A gg PNA A gg PNA 0A gg PNA A gg PNA 0A gg PNA 00A gg PN 00A gg PN 0A gg Utilization category gg Order Power losses Weight code [W] [kg] OEZ:0.90 0. OEZ:07.0 0. OEZ:08 7.90 0. OEZ:09.0 0. OEZ:00.00 0. OEZ:0 7.0 0. OEZ:077.8.08 OEZ:07 0..08 Utilization category am Order Power losses Weight Package code [W] [kg] [pcs] PNA A am OEZ:0. 0. PNA 00A am OEZ:0 0.8 0. PNA 00A am OEZ:0 7.0.00 PNA 0A am OEZ:07 0.0.00 Type Fuse-links with blade contacts PNa ) Utilization category gg In Type Order Power losses Weight [A] code [W] [kg] 0 PNa 0A gg OEZ:8.0 800 PNa 800A gg OEZ:87 9.0 00 PNa 00A gg OEZ:88 8.0 0 PNa 0A gg OEZ:89.0 0 PNa 0A gg OEZ:90 8.0 ) Fuses PNa are not manufactured in Cd/Pb free version. Type - Utilization category am Order Power losses Weight Package code [W] [kg] [pcs] Accessories Disconnecting links Signal contact Electronic signalling of fuse state Replacement handles E ZP.., TMa.. VL0 MD-M D.. page E8 page E9 page E0 page E

PNA FUSE-LINKS WITH BLADE CONTACTS PNA Specifications Utilization category gg Type PNA000 PNA00 PNA PNA PNA / PN PNa Standards IEC 09 IEC 09 IEC 09 IEC 09 IEC 09 IEC 09 DIN 0 DIN 0 DIN 0 DIN 0 DIN 0 DIN 0 EN 09 EN 09 EN 09 EN 09 EN 09 EN 09 Approval marks Rated operating voltage U n AC 00 V, 00 V AC 00 V AC 00 V AC 00 V AC 00 V AC 00 V DC 0 V DC 0 V DC 0 V DC 0 V DC 0 V / 0 V DC 0 V Rated operating current I n A A 0 A 00 A 00 0 A 0 00 A Breaking capacity AC ka ka ka ka ka ka (RMS) DC 0 ka 0 ka 0 ka 0 ka 0 ka 0 ka Utilization category gg gg gg gg gg gg Fuse-link size 000 (00C) 00 a Selectivity :. :. :. :. :. :. Utilization category am Type PNA000 PNA00 PNA PNA PNA Standards IEC 09 IEC 09 IEC 09 IEC 09 IEC 09 DIN 0 DIN 0 DIN 0 DIN 0 DIN 0 EN 09 EN 09 EN 09 EN 09 EN 09 Approval marks Rated operating voltage U n AC 00 V AC 00 V AC 90 V AC 90 V AC 90 V DC 0 V DC 0 V DC 0 V DC 0 V DC 0 V Rated operating current I n 0 A 0 A 0 A 00 A 0 A Breaking capacity AC ka ka ka ka ka (RMS) DC 0 ka 0 ka 0 ka 0 ka 0 ka Utilization category am am am am am Fuse-link size 000 (00C) 00 Selectivity :. :. :. :. :. E

PNA FUSE-LINKS WITH BLADE CONTACTS PNA Dimensions Size I n [A] Dimensions gg am a a a a b (min.) c d e e f 000 0 79.9.8.7 0..0.8. 0..0 7.8 00 0 79.9.8.9 0..0.8. 8.0 0.0. (0) 0.8 7.. 9.0.0 9.8. 8.0 0.0. 00 0 0. 7.7. 9.8 0.0 0.8. 7. 7. 9. (0) 0 0. 7.7. 9.8 0.0 8.. 7. 7. 9. 00 00. 7.. 9..0 8.. 7.8 7.8.8 (0) 00 00 00. 7.. 9..0 0.. 7.8 7.8.8 00 0 00 0.0 7.0.0 9.0.0 0.0. 7. 7..8 a 0 0-00± 8. 8± 90± 0.0 8±.0.0 87.0 0.0 Characteristics Prearcing time/current characteristic PNA000.00 gg Prearcing time/current characteristic PNA gg t v [s] 0 - - A A A 0 A A A A 0 A 0 A A 0 A A A U n = AC 00/00 V U n = DC 0 V / ms - 8 8 8 I [A] p t v [s] 0 - - - A 0 A A A/ A 0 A 0 A A 0 A A A 00 A A 0 A 8 8 I [A] p U n = AC 00 V U n = DC 0 V / ms 8 E

PNA FUSE-LINKS WITH BLADE CONTACTS PNA Characteristics Prearcing time/current characteristic PNA gg t v [s] A 0 A 0 A A 0 A A A 00 A A 0 A A 0 A 00 A U n = AC 00 V U n = DC 0 V / ms Prearcing time/current characteristic PNA, PN ) gg t v [s] 0 A ) 00 A ) 00 A 0 A A 0 A A 00 A U n = AC 00 V U n = DC 0 V / ms U n = DC 0 V / ms ) 0 0 - - - - - I p[a] - 8 8 8 I p[a] Prearcing time/current characteristic PNa gg t [s] v 0 I [A] n 0 800 00 0 0 U n = AC 00 V U n = DC 0 V / ms h 0 0 min 0 0 s Cut-off characteristic PNA000. 00 gg I c [A] U n = AC 00/00 V A A 0 A A 0 A 0 A A A A 0 A A A A - 0-8 8 8 I p[a] - ms I [A] p E7

PNA FUSE-LINKS WITH BLADE CONTACTS PNA Characteristics Cut-off characteristic PNA, gg I c [A] U n = AC 00 V 00 A 0 A A 0 A A 00 A A A 0 A A 0 A 0 A A / A A 0 A A Cut-off characteristic PNA, PN ) gg I c [A] 0 A ) 00 A ) 00 A 0 A A 0 A A 00 A U n = AC 00 V 8 8 8 I t t characteristic PNA000, 00 gg I t t [A s] 0 s - s - s - s - s 8 8 8 8 I p[a] I [A] p U n = AC 00 V A A 0 A A 0 A 0 A A A I t t, I t c values I t I t t I t c ms ms AC 00 V AC 00 V [ A s] [ A s] [ A s] [ A s] PNA000 A gg 8 8 PNA000 A gg 7 07 8 PNA000 A gg 70 78 89 PNA000 0A gg 70 8 8 70 PNA000 A gg 00 00 8 PNA000 A gg 00 00 8 8 PNA000 A gg 000 0 88 00 PNA000 0A gg 000 980 7 9 8 9 PNA000 0A gg 000 90 08 PNA000 A gg 7 700 00 7 9 0 7 PNA000 80A gg 000 00 0 9 7 PNA000 0A gg 000 0 00 0 9 7 979 PNA000 A gg 000 000 7 000 000 PNA000 A gg 89 000 8 0 000 - PNA00 A gg 000 900 89 00 PNA00 A gg 8 000 8 0 8 A 0 A A A A k 8 8 8 Cut-off characteristic PNa gg I c [A] Correction factor k of I t c dependence on operating voltage (I t c ) f(u) = k x I t c PNA000, 00,,,, PN a PNa gg,0,00 0,90 0,80 0,70 0,0 00 0 00 0 00 0 00 0 I [A] p U n = AC 00 V 00 A 0 A 000 A 800 A 0 A I p[a] U[ V] E8

PNA FUSE-LINKS WITH BLADE CONTACTS PNA Characteristics I t t characteristic I t t, I t c values PNA, gg I t I t t I t c U n = AC 00 V ms ms AC 00 V AC 00 V [ A s] [ A s] [ A s] [ A s] 7 PNA A gg 70 70 000 PNA 0A gg 70 8 0 990 PNA A gg 00 90 PNA A gg 0 00 70 900 PNA A gg 000 0 7 PNA 0A gg 000 9 0 00 00 A 0 PNA 0A gg 000 880 0 800 A PNA A gg 7 700 9 790 8 00 00 0 A A PNA 80A gg 000 00 800 000 00 A PNA 0A gg 000 900 700 00 PNA A gg 000 8 00 8 00 9 00 A A PNA A gg 8 000 80 00 8 000 7 000 0 A PNA 00A gg 000 000 7 000 000 PNA A gg 000 000 8 000 000 A PNA 0A gg 0 000 000 8 000 90 000 0 A 0 A PNA A gg 000 0 7 90 A / A PNA 0A gg 000 9 000 0 PNA 0A gg 000 7 00 900 7 900 A 0 s PNA A gg 7 700 9 0 900 7 000 - s 0 A A PNA 80A gg PNA 0A gg 000 000 00 800 800 00 000 7 000 - PNA A gg 000 7 00 9 800 8 000 s PNA A gg 8 000 79 00 8 000 7 000 - PNA 00A gg 000 000 7 000 000 s PNA A gg 000 000 8 000 000 - s PNA 0A gg 0 000 000 8 000 7 000 PNA A gg 000 0 000 87 000 0 000 PNA 0A gg 000 97 000 00 000 000 8 8 8 8 PNA 00A gg 9 000 70 000 00 000 7 000 I p[a] PNA 00A gg 000 000 7 000 000 PNA A gg 000 000 8 000 000 PNA 0A gg 0 000 000 8 000 7 000 PNA A gg 000 000 8 000 990 000 PNA 0A gg 000 000 977 000 000 PNA 00A gg 9 000 707 000 000 08 000 PN 00A gg 790 000 000 000 0 000 8 000 PN 0A gg 00 000 900 000 0 000 70 000 I t t [A s] I t t characteristic PNA, PN ) gg I t c characteristic PNa gg I t t [A s] 8 7 0 s - s - s - s U n = AC 00 V 0 A ) - s I t c [A s] 8 7 00 A 0 A 000 A 800 A 0 A U n = AC 00 V 00 A ) 00 A 0 A A 0 A A 00 A I [A] p 8 8 8 8 I [A] p E9

PNA FUSE-LINKS WITH BLADE CONTACTS PNA Characteristics Prearcing time/current characteristic PNA000, 00 am A A A 0 A A A 0 A 0 A A 0 A A A U n = AC 00 V U n = DC 0 V / ms Prearcing time/current characteristic PNA,, am t v [s] A 0 A A A 00 A 0 A A 00 A 00 A 0 A U n = AC 90 V U n = DC 0 V / ms 0 0 - - - 8 8 8 I p[a] Cut-off characteristic PNA000, 00 am I c [A] U n = AC 00 V A A 0 A A 0 A 0 A A A 0 A A A A t [s] v - - - 8 8 8 I p[a] Time/current ranges PNA000, 00,,, am 0 minimum melting time maximum breaking time overload capacity characteristic h 0 0 min 0 0 s Cut-off characteristic PNA,, am I c [A] 8 8 8 I p [A] 0 A 00 A 00 A A 0 A 00 A A A 0 A A U n = AC 90 V - - 0 x I n 0 8 8 8 I p [A] E0

PNA FUSE-LINKS WITH BLADE CONTACTS PNA Characteristics I t t characteristic PNA000, 00 am I t t [A s] 7 0 s - s - s - s U n = AC 00 V A A 0 A A 0 A 0 A A A 0 A A 8 8 8 8 I p [A] I t t characteristic PNA,, am I t t [A s] 8 7 0 s - s - s - s - s A A U n = AC 90 V I t t, I t c values I t I t t I t c ms ms AC 00 V AC 00 V [A s] [A s] [A s] [A s] PNA000 A am 7 PNA000 A am 0 0 0 0 PNA000 A am 70 800 00 00 PNA000 0A am 80 00 00 00 PNA000 A am 00 000 800 00 PNA000 A am 00 00 00 00 PNA000 0A am 700 00 7 00 9 00 PNA000 0A am 800 8 00 9 89 00 PNA000 A am 9 00 000 7 000 PNA000 80A am 000 000 7 000 000 PNA00 0A am 000 7 000 000 7 000 PNA00 A am 000 0 000 98 000 000 PNA00 A am 000 9 000 0 000 70 000 PNA A am 000 7 700 00 000 PNA 80A am 00 0 800 8 000 80 000 PNA 0A am 00 9 000 8 000 000 PNA A am 7 000 7 00 97 000 000 PNA A am 90 000 000 000 000 PNA 00A am 0 000 98 000 8 000 7 000 PNA 0A am 0 000 000 0 000 000 PNA A am 7 000 7 00 97 000 000 PNA A am 90 000 000 000 000 PNA 00A am 0 000 98 000 8 000 7 000 PNA 0A am 0 000 000 0 000 000 PNA A am 70 000 0 000 000 000 000 PNA 00A am 000 70 000 9 000 00 000 PNA A am 70 000 0 000 000 000 000 PNA 00A am 000 70 000 9 000 00 000 PNA 00A am 70 000 9 000 09 000 8 000 PNA 0A am 90 000 7 000 800 000 00 000 k 0 A 00 A 00 A A 0 A 00 A A A 0 A A 8 8 8 8 Correction factor k of I t c dependence on operating voltage (I t c ) f(u) = k x I t c PNA000, 00 am,00 0,90 0,80 0,70 I [A] p U n = AC 00 V Correction factor k of I t c dependence on operating voltage (I t c ) f(u) = k x I t c PNA,, am k,00 0,80 0,0 U n = AC 90 V 0,0 0,0 0,0 00 0 00 0 00 0 00 U[ V] 0,0 00 00 00 00 00 700 U[ V] E

PNA, PHNA ACCESSORIES FOR PNA, PHNA Disconnecting links They are used wherever it is necessary to disconnect power supply or for various reasons to replace fuse-link (in measuring etc.). They are used in fuse switch-disconnectors, fuse-rails and fuse-bases. I n Type Order Size Weight Package [A] code [kg] [pcs] ZP000 ) OEZ:00 000, 00 0.09 0 ZP OEZ:00 0.7 00 ZP OEZ:00 0. 0 ZP OEZ:00 0.9 00 ZP/00 OEZ: 0. 0 TMa/0A OEZ: a.8 0 TMa/0A OEZ:80 a.0 ) Can be used in fuse switch-disconnectors of size 000, 00 and fuse-bases size 00 Specifications Type ZP.. Standards EN 09-, -; DIN 0 Approval marks Dimensions Type Dimensions [mm] A B C D E ZP000 78. 0.0 ZP 0 0 0.0 0.0 ZP 8 8 0.0 0.0 ZP 0 70 0.0 0.0 ZP/00 0 0 70 0.0 0.0 TMa/0A 0 89 98 00.0 0.0 TMa/0A 0 8 8 00.0. E8

PNA, PHNA ACCESSORIES FOR PNA, PHNA Signal contact For all types and sizes of fuse-links with blade contacts up to AC 90 V / DC 0 V. Fuse-links are equipped with visual state indicator installed on the upper fuse holder, which can be used as a releasing device for the signal contact VL0 for remote signalling of fuse-link state. Connection is performed by means of sleeves on flat connector wide.8 mm. Type Order Weight Package code [kg] [pcs] VL0 OEZ:08 0.0 Specifications Type VL0 Approval marks Rated insulation voltage U i kv Rated current/voltage of contacts A / AC V 0. A / DC 0 V Dimensions Diagram State of contacts with installed signal contact VL0 on the fuse-link: fuse not blown contacts C NC closed. C NO NC E9

PNA, PHNA ACCESSORIES FOR PNA, PHNA Electronic signalling of fuse state Can be used for fuse-links of all types and sizes. Monitoring of fuse-links state in fuse switch-disconnectors and fuse-bases. Auxiliary contact without power supply contact opened. Auxiliary contact with power supply contact closed. Fuse-link blowing in the circuit contact opened. The devices are designed as modular for mm cutout in the switchboard cover plate. Mounting on U rails according to EN 07 (steel rail recommended). Type Order Weight Package code [kg] [pcs] MD-M OEZ:8 0. Specifications Type MD-M Standards IEC 0 DIN VDE - Approval marks Rated operating voltage U e AC 0 V Rated operating current I e A Rated control voltage U c AC x V Operating range 0.8. xu c Rated frequency 0 00 Hz Input impedance > 000 Ω/V Maximum permitted backwards power supply 90 % Response/relase time < 0 ms Rated impulse withstand voltage U imp > kv Electrical endurance AC-.x Mechanical endurance > 8 Degree of protection barrel/terminal block IP0/IP0 Number of contacts Connection cross-section solid max. x. mm stranded with end sleeve min. x 0. mm Operating ambient temperature -0 +0 C Climatic resistance according to EN 008-0/00/0 ) The internal resistance of measuring circuits of the fuse monitor in the MΩ range, therefore when there is fuse missing or it is defective the conditions of contact voltage are still kept (according to EC 97-, internal resistance > 000 Ω/V).In order to switch off the device the main back-up circuit breaker has to be disconnected. E0

PNA, PHNA ACCESSORIES FOR PNA, PHNA Dimensions Diagram L L L L L L AC 0 V A L L L 90 L L L Connection -pole -pole - or -pole L L L N L L L L L L L L L L L L L L F F F MD-M F F F MD-M F MD-M L` L` L` L` L` L` L` L` L` OFF ON K ) It is possible to check the second fuse-link in the same or different phase at the terminals L-L. ~ M N Application from practice, e.g. automatic disconnection and lock of turning-on of the three-phase motor when there is drop-out of one or several fuse-links. E

PNA, PHNA ACCESSORIES FOR PNA, PHNA Replacement handles Are used for fuse-links handling under voltage but without current. DPH - it is equipped with insulating end barriers to prevent accidental contact, mainly if barriers are not used between fuse-bases. It is intended for single-pole fuse-bases without end barriers. DP - it is intended for handling fuse-links in both single and three-pole fuse-bases, which are equipped with insulating barriers. DPM - the replacement handle with a protective sleeve to increase the safety of personnel in handling fuse-links. The sleeve is made from beef leather. Type Order Weight Package code [kg] [pcs] DPH OEZ:00 0. DP OEZ:077 0.0 DPM OEZ:077 0. Specifications Type DPH DP DPM Standards IEC 09-, -; IEC 09-, -; IEC 09-, -; EN 09-, - EN 09-, - Approval marks Rated insulation voltage U i AC 000 V AC 000 V AC 000 V Fuse-link size 000, 00.,, 000, 00.,, 000, 00.,, E

PNA, PHNA ACCESSORIES FOR PNA, PHNA Dimensions DPH 8 77 DP. max. 0.7 8. 9. DPM ~0 E