CHARACTERIZING PROCESS SEMICONDUCTOR THIN FILMS WITH A CONFOCAL MICRO X-RAY FLUORESCENCE MICROSCOPE

Similar documents
Time-Resolved μ-xrf and Elemental Mapping of Biological Materials

MEASUREMENT CAPABILITIES OF X-RAY FLUORESCENCE FOR BPSG FILMS

AEROSOL FILTER ANALYSIS USING POLARIZED OPTICS EDXRF WITH THIN FILM FP METHOD

ELECTRIC FIELD INFLUENCE ON EMISSION OF CHARACTERISTIC X-RAY FROM Al 2 O 3 TARGETS BOMBARDED BY SLOW Xe + IONS

ACCURATE QUANTIFICATION OF RADIOACTIVE MATERIALS BY X-RAY FLUORESCENCE: GALLIUM IN PLUTONIUM METAL

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K.

NEW CORRECTION PROCEDURE FOR X-RAY SPECTROSCOPIC FLUORESCENCE DATA: SIMULATIONS AND EXPERIMENT

ULTRATHIN LAYER DEPOSITIONS A NEW TYPE OF REFERENCE SAMPLES FOR HIGH PERFORMANCE XRF ANALYSIS

RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA

IMPROVEMENT OF DETECTION LIMITS OF A PORTABLE TXRF BY REDUCING ELECTRICAL NOISE

A COMPACT X-RAY SPECTROMETER WITH MULTI-CAPILLARY X-RAY LENS AND FLAT CRYSTALS

X Rays & Crystals. Characterizing Mineral Chemistry & Structure. J.D. Price

MS482 Materials Characterization ( 재료분석 ) Lecture Note 12: Summary. Byungha Shin Dept. of MSE, KAIST

Issues With TXRF Angle Scans and Calibration

GLANCING INCIDENCE XRF FOR THE ANALYSIS OF EARLY CHINESE BRONZE MIRRORS

ABNORMAL X-RAY EMISSION FROM INSULATORS BOMBARDED WITH LOW ENERGY IONS

Auger Electron Spectroscopy

ELEMENTAL IMAGING FOR PHARMACEUTICAL TABLET FORMULATION ANALYSIS BY MICRO X-RAY FLUORESCENCE

DEVELOPMENT OF A NEW POSITRON LIFETIME SPECTROSCOPY TECHNIQUE FOR DEFECT CHARACTERIZATION IN THICK MATERIALS

Auger Electron Spectroscopy Overview

BENEFITS OF IMPROVED RESOLUTION FOR EDXRF

TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER

MS482 Materials Characterization ( 재료분석 ) Lecture Note 4: XRF

J. Price, 1,2 Y. Q. An, 1 M. C. Downer 1 1 The university of Texas at Austin, Department of Physics, Austin, TX

Auger Electron Spectroscopy (AES)

Horst Ebel, Robert Svagera, Christian Hager, Maria F.Ebel, Christian Eisenmenger-Sittner, Johann Wernisch, and Michael Mantler

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

USABILITY OF PORTABLE X-RAY SPECTROMETER FOR DISCRIMINATION OF VALENCE STATES

MS482 Materials Characterization ( 재료분석 ) Lecture Note 5: RBS

In-situ Monitoring of Thin-Film Formation Processes by Spectroscopic Ellipsometry

Atomic layer deposition of titanium nitride

FACTORS AFFECTING IN-LINE PHASE CONTRAST IMAGING WITH A LABORATORY MICROFOCUS X-RAY SOURCE

Electron probe microanalysis - Electron microprobe analysis EPMA (EMPA) What s EPMA all about? What can you learn?

ION-EXCHANGE FILMS FOR ELEMENT CONCENTRATION IN X-RAY FLUORESCENCE ANALYSIS WITH TOTAL REFLECTION OF THE PRIMARY BEAM.

INFLUENCE OF GROWTH INTERRUPTION ON THE FORMATION OF SOLID-STATE INTERFACES

MATERIALS CHARACTERIZATION USING A NOVEL SIMULTANEOUS NEAR-INFRARED/X-RAY DIFFRACTION INSTRUMENT

APPLICATION OF MICRO X-RAY FLUORESCENCE SPECTROMETRY FOR LOCALIZED AREA ANALYSIS OF BIOLOGICAL AND ENVIRONMENTAL MATERIALS

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

IMPROVING THE ACCURACY OF RIETVELD-DERIVED LATTICE PARAMETERS BY AN ORDER OF MAGNITUDE

FUNDAMENTAL PARAMETERS ANALYSIS OF ROHS ELEMENTS IN PLASTICS

The design of an integrated XPS/Raman spectroscopy instrument for co-incident analysis

Resonant photo-ionization of point defects in HfO 2 thin films observed by second-harmonic generation.

MCSHAPE: A MONTE CARLO CODE FOR SIMULATION OF POLARIZED PHOTON TRANSPORT

produced a sputter rate of 0.9 nm/s for the radially profiled, un-etched wires. A slightly

THE IMPORTANCE OF THE SPECIMEN DISPLACEMENT CORRECTION IN RIETVELD PATTERN FITTING WITH SYMMETRIC REFLECTION-OPTICS DIFFRACTION DATA

MS482 Materials Characterization ( 재료분석 ) Lecture Note 5: RBS. Byungha Shin Dept. of MSE, KAIST

Applications of XPS, AES, and TOF-SIMS

A NEW SMALL ANGLE X-RAY SCATTERING TECHNIQUE FOR DETERMINING NANO-SCALE PORE/PARTICLE SIZE DISTRIBUTIONS IN THIN FILM

Application of X-ray Spectrometry at X-ray Absorption Edges for Investigation of Human Albumin

ANALYSIS OF LOW MASS ABSORPTION MATERIALS USING GLANCING INCIDENCE X-RAY DIFFRACTION

FUNDAMENTAL PARAMETER METHOD USING SCATTERING X-RAYS IN X-RAY FLUORESCENCE ANALYSIS

Auger Electron Spectroscopy (AES) Prof. Paul K. Chu

SUPPLEMENTARY MATERIALS FOR PHONON TRANSMISSION COEFFICIENTS AT SOLID INTERFACES

Portable type TXRF analyzer: Ourstex 200TX

A. Optimizing the growth conditions of large-scale graphene films

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

Monochromatic Wavelength Dispersive X-ray Fluorescence for Improved Pu Assay

Fig 1: Auger Electron Generation (a) Step 1 and (b) Step 2

Copyright(c)JCPDS-International Centre for Diffraction Data 2001,Advances in X-ray Analysis,Vol

Microscopy AND Microanalysis MICROSCOPY SOCIETY OF AMERICA 2006

Electron Rutherford Backscattering, a versatile tool for the study of thin films

EE 527 MICROFABRICATION. Lecture 5 Tai-Chang Chen University of Washington

Extraction of Depth Information from ARXPS Data

SYNCHROTRON X-RAY MICROBEAM CHARACTERIZATION OF SMECTIC A LIQUID CRYSTALS UNDER ELECTRIC FIELD

Self-study problems and questions Processing and Device Technology, FFF110/FYSD13

QUANTITATIVE ENERGY-DISPERSIVE ELECTRON PROBE X-RAY MICROANALYSIS OF INDIVIDUAL PARTICLES

ADVANTAGES AND DISADVANTAGES OF BAYESIAN METHODS FOR OBTAINING XRF NET INTENSITIES

Frequency dispersion effect and parameters. extraction method for novel HfO 2 as gate dielectric

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

EFFECT OF CALIBRATION SPECIMEN PREPARATION TECHNIQUES ON NARROW RANGE X-RAY FLUORESCENCE CALIBRATION ACCURACY

CHARACTERIZATION OF Pu-CONTAINING PARTICLES BY X-RAY MICROFLUORESCENCE

Large Scale Direct Synthesis of Graphene on Sapphire and Transfer-free Device Fabrication

X-RAY MICRODIFFRACTION STUDY OF THE HALF-V SHAPED SWITCHING LIQUID CRYSTAL

STRESS ANALYSIS USING BREMSSTRAHLUNG RADIATION

A DIVISION OF ULVAC-PHI

Analysis of Cadmium (Cd) in Plastic Using X-ray Fluorescence Spectroscopy

PERFORMANCE OF A ROOM TEMPERATURE GAS PROPORTIONAL SCINTILLATION COUNTER IN X-RAY ANALYSIS OF METALLIC ALLOYS EXCITED WITH ALPHA PARTICLES

PERFORMANCE OF A BOREHOLE XRF SPECTROMETER FOR PLANETARY EXPLORATION

EE143 Fall 2016 Microfabrication Technologies. Lecture 6: Thin Film Deposition Reading: Jaeger Chapter 6

THE EFFECT OF THE SIGNAL PROCESSOR ON THE LINE SHAPE

SILICON DRIFT DETECTORS FOR HIGH RESOLUTION, HIGH COUNT RATE X-RAY SPECTROSCOPY AT ROOM TEMPERATURE

Brookhaven National Laboratory ABSTRACT

Graphene films on silicon carbide (SiC) wafers supplied by Nitride Crystals, Inc.

Lecture 150 Basic IC Processes (10/10/01) Page ECE Analog Integrated Circuits and Systems P.E. Allen

Industrial Applications of Ultrafast Lasers: From Photomask Repair to Device Physics

NON-DESTRUCTIVE EVALUATION IN MANUFACTURING USING SPECTROSCOPIC. John A. Woollam and Paul G. Snyder

An Analysis of Secondary Enhancement Effects in Quantitative XRFA

Supplementary Information

The Benefit of Wide Energy Range Spectrum Acquisition During Sputter Depth Profile Measurements

ECE Semiconductor Device and Material Characterization

Secondary ion mass spectrometry (SIMS)

X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu

REALIZATION OF AN ASYMMETRIC MULTILAYER X-RAY MIRROR

COMPARISON OF THREE UNIVERSAL CURVES FOR THE ESCAPE PROBABILITY OF X-RAY EXCITED ELECTRONS - I. THEORY

Quantum Mechanical Simulation for Ultra-thin High-k Gate Dielectrics Metal Oxide Semiconductor Field Effect Transistors

Impact of Contact Evolution on the Shelf Life of Organic Solar Cells

SEM. Chemical Analysis in the. Elastic and Inelastic scattering. Chemical analysis in the SEM. Chemical analysis in the SEM

XPS/UPS and EFM. Brent Gila. XPS/UPS Ryan Davies EFM Andy Gerger

Bratislava, Slovak Republic.

Transcription:

CHARACTERIZING PROCESS SEMICONDUCTOR THIN FILMS WITH A CONFOCAL MICRO X-RAY FLUORESCENCE MICROSCOPE 218 Chris M. Sparks 1, Elizabeth P. Hastings 2, George J. Havrilla 2, and Michael Beckstead 2 1. ATDF, 276 Montopolis Drive, Austin, Texas 78741 2. Los Alamos National Laboratory, MS K484, Los Alamos, New Mexico 87545 ABSTRACT The versatility of confocal micro X-ray fluorescence (MXRF) in analyzing thin films on semiconductor wafers is demonstrated. Unlike conventional MXRF, confocal MXRF can depth profile sample layers and reduce spectral background. Non-destructive quantification of the silicon dioxide (SiO 2 ) concentration in hafnium silicate (HfSiO) thin films is an example of one application demonstrating the advantage of confocal MXRF. Additionally, the growth of titanium nitride (TiN) films on various high-k gate dielectric substrates was analyzed with confocal MXRF due to its ability to detect sub-nm film thickness changes. INTRODUCTION To maintain the expectations of Moore s Law, the International Technology Roadmap for Semiconductors proposes that new materials replace traditional ones in semiconductor processing [1]. Hafnium silicate (HfSiO) is a potential gate dielectric candidate that has a higher dielectric constant than either silicon dioxide (SiO 2 ) or silicon oxynitride (SiON) and may have suitable robust properties for maintaining favorable electrical characteristics under device processing conditions [2]. Currently, various deposition processes for HfSiO are being evaluated in ATDF s fab. One parameter being assessed is the SiO 2 concentration (mol %) in HfSiO films. To ensure reproducible deposition of the films, a rapid, in-line, non-destructive metrology technique is necessary. X-ray fluorescence techniques are well known for their excellent sensitivity to elemental composition, are non-destructive, and, therefore, are ideal for thin film analysis. This paper demonstrates the applicability of confocal micro X-ray fluorescence (MXRF) in characterizing HfSiO thin films (~ 15 nm) with varying mol % SiO 2 concentrations. Atomic layer deposition (ALD) is currently being investigated for highly conformal film deposition and precise thickness control over hafnium silicates. This type of film is grown layer by layer, and obtaining a depth profile of these layers provides another facet of the material s characterization process. Consequently, the non-destructive depth profiling capabilities of confocal MXRF on these thin films is also explored. Due to undesirable properties that can adversely alter the effective electrical thickness of the gate dielectric [3], new materials are also being investigated for the gate electrode. Titanium nitride

This document was presented at the Denver X-ray Conference (DXC) on Applications of X-ray Analysis. Sponsored by the International Centre for Diffraction Data (ICDD). This document is provided by ICDD in cooperation with the authors and presenters of the DXC for the express purpose of educating the scientific community. All copyrights for the document are retained by ICDD. Usage is restricted for the purposes of education and scientific research. DXC Website www.dxcicdd.com ICDD Website - www.icdd.com

is a potential gate electrode material, which may replace polysilicon when high-k gate dielectrics replace the conventional SiO 2 or SiON. The growth of a TiN gate electrode deposited on various gate dielectrics is characterized in this study as well. 219 EXPERIMENTAL The confocal MXRF microscope used in this study was an in-house built system designed in a joint project between Los Alamos National Laboratory and X-Ray Optical Systems (XOS, Albany, NY). To create a confocal analysis volume, both the source and the detector were fitted with polycapillary optics. The X-ray and detection polycapillary optics were positioned so that the focal point of each beam overlapped, creating the confocal analysis spot. The confocal analysis volume was an ellipsoid (3 x 3 x 6 µm). A sealed Ag tube source operating at.5 ma and 5 kv was used as the source. Acquisition time for spectral data collection was 1 s on an AmpTek detector. The samples were placed as received into the microscope and analyzed under ambient conditions. A depth profile was collected to determine the surface position, and spectra were collected at the surface. HfSiO was deposited by ALD onto 2 mm diameter Si (1) wafers to create a target 15 nm film. The HfSiO wafers were broken into 1-inch square pieces to fit easily into the microscope s sample area. Film uniformity across a wafer by ALD is excellent (< 1% deviation); therefore, the broken wafer pieces were a reasonable representation of the entire film. Table 1 lists the characterized HfSiO films based on mol % and film thickness. The concentration of SiO 2 (mol %) and thickness of the films were determined by Rutherford backscattering spectrometry [4], except for the pure HfO 2 film for which the thickness was determined by spectroscopic ellipsometry [4]. Film (%) Thickness (nm) 1% HfO 2 1. 33% SiO 2 13.7 45% SiO 2 13. 55% SiO 2 13.5 67% SiO 2 8.8 Table 1. List of HfSiO films used in the study with varying concentrations of SiO 2 (mol %). In addition, a series of TiN films was also deposited by ALD on top of various dielectrics. The series included 5 1 deposition cycles, during which each cycle deposited.12 nm of material. The dielectrics used in this study were 1 nm films of SiO 2, HfSiO (2 mol % SiO 2 ), and HfO 2. RESULTS AND DISCUSSION With the polycapillary optics on the source, a high X-ray flux reaches the sample in a tightly focused beam. The polycapillary optics beam on the detector overlaps with the focused X-ray

beam creating a confocal volume, thus excluding all other spatial areas except for the confocal region. When used in a confocal arrangement the optics allow for an increase in spatial resolution and a reduction of background counts [5, 6]. 22 Figure 1 is the background subtracted Hf-L α (7.9 kev) signal from the 1 nm HfO 2 film showing the excellent signal-to-noise of confocal MXRF. Samples with increasing concentrations of SiO 2 in the HfSiO film were then analyzed to establish a correlation between the mol % SiO 2 and the Hf signal from the confocal MXRF. Overlays of the Hf-L α signal from the series of HfSiO films, with increasing mol % SiO 2, are shown in Figure 2. Based on Figure 2, the Hf-L α peak intensity decreases with increasing mol % SiO 2, indicating that the confocal MXRF is capable of discriminating between changes in composition of the HfSiO thin films. 8 Hf L α Signal Intensity (cps) 6 4 2 2 4 6 8 1 12 14 Energy (kev) Figure 1: Background corrected Hf signal from a 1 nm HfO 2 film Signal Intensity (cps) 6 5 4 3 2 1 1% HfO 2 33% SiO 2 45% SiO 2 55% SiO 2 67% SiO 2 7.6 7.8 8. 8.2 8.4 Energy (kev) Figure 2: Overlays of Hf peak with increasing % SiO 2 in the deposited films Calculating the area under the Hf-L α peaks (~7.6 8.3 kev as indicated by the vertical lines in Figure 2) and plotting it against the mol % SiO 2 in the films generates the relationship shown in Figure 3. The best-fit line has an R 2 correlation value of.99, which is similar to the correlation to the same set of wafers measured by total reflection X-ray fluorescence (TXRF) [7]. The

TXRF used both a Ag anode operating at 6 W and a W anode operating at 4 W, while the MXRF s Ag anode was operating only at 25 W. The comparable sensitivity of both techniques to the compositional changes of the high-k gate dielectric films with this large difference in power is a testament to the efficiency of the polycapillaries and the confocal arrangement of the optics of the confocal MXRF microscope. A future study will be to test how well the confocal MXRF can discriminate among different compositional 3 nm HfSiO films that are a closer representation of actual device process parameters. 221 16 12 Area 8 4 R 2 =.99 1 2 3 4 5 6 7 Percent SiO 2 (%) Figure 3. Relationship of the area under the Hf peaks to the mol % SiO 2 in the HfSiO films Since ALD grows film in layers on top of the deposited layer, depth profile information is critical when characterizing new films or monitoring process control. There may be an interfacial region between the substrate (i.e., the Si wafer) and the bulk of the film material that will affect the electrical performance of the final semiconductor device. Standard laboratory sputtering techniques, for example, secondary ion mass spectrometry or Auger electron spectroscopy, while providing relevant data, are destructive techniques. A technique that could non-destructively depth profile thin films would provide valuable information to engineers developing a process if that characterized film could then be returned to the process line. Figure 4 shows the overlay of depth profiles for all of the HfSiO films. However, since the size of the 35 3 1% HfO 2 Signal Intensity (cps) 25 2 15 1 33% SiO 2 45% SiO 2 55% SiO 2 67% SiO 2 5 5 1 15 2 25 3 Distance (microns) Figure 4. Depth profile of HfSiO films (Hf signal intensity)

probe beam and the z-axis step height are both much greater than the thickness of the films the figure is likely a representation of the height of optimum focus for the spectrometer instead of a true depth profile. Future studies will investigate whether a mathematical transformation would be able to extract accurate depth profile information from the raw data. 222 Confocal MXRF was also used to study the growth of TiN on three different gate dielectric materials. Figure 5 shows the area under the Ti-K α (4.5 kev) peak for cycles of ALD TiN deposition (, 5, 1, 2, 3, 5, 7, and 1 cycles) on the gate dielectric materials SiO 2, HfSiO (2 mol % SiO 2 ), and HfO 2. The confocal MXRF is sensitive enough to detect an increase in the Ti signal on films that had five ALD cycles (~.6 nm thick) on all three substrates. There was also a linear relationship between the number of deposition cycles and the area under the Ti-K α peak; however, compared to a previous study using TXRF analysis on these films [8], there is less agreement between the confocal MXRF and the TXRF data. Both techniques have linear relationships but when examining the TXRF data, the slope from the TiN growth on the HfO 2 film is greater than that of the HfSiO, which is greater than that of the SiO 2. Conversely, Figure 5 illustrates that confocal MXRF data for the slope of the TiN growth on all three substrates are practically the same. This difference may arise from the TXRF being a more surface-sensitive instrument than the confocal MXRF. As the films become thicker with additional ALD cycles, the confocal MXRF still samples well into the substrate with its micrometer sampling beam while the TXRF samples a greater percentage of the TiN film and less of the substrate. Therefore, the subtler slope changes may be more difficult to pull out using the confocal MXRF. 14 Area 12 1 8 6 SiO2 HfO2 HfSiO 4 2 2 4 6 8 1 12 TiN cycles Figure 5: Area of the Ti signal vs. cycles of ALD TiN deposited on SiO 2, HfO 2, and HfSiO CONCLUSIONS Confocal MXRF has the capability to quantitatively measure thin HfSiO films with increasing concentrations of SiO 2. There is a linear relationship between the Hf-L α signal and the mol % SiO 2. By using a non-destructive technique, these films (once measured) could be returned to the line for further processing and remeasurement. More development is needed to take advantage of the non-destructive depth profiling capability of confocal MXRF, which would be an extremely useful application for the semiconductor manufacturing industry if it works for thin

films. Sensitivity to sub-nm TiN film growth was shown as well as a linear relationship of the ALD cycles to the Ti signal measured on the confocal MXRF. 223 ACKNOWLEDGEMENTS The authors would like to thank Todd Rhoad of ATDF and Kisik Choi of SEMATECH for supplying the films used in this study. REFERENCES 1. International Technology Roadmap for Semiconductors website, http://public.itrs.net/ 2. P. Zeitzoff, R. Murto, and H. Huff. Solid State Technology, 45 (7), 22, 71-76. 3. P. Singer. Semiconductor International, July issue, p. 46, 23. 4. Internal ATDF publication 5. X. Ding, N. Gao, and G. Havrilla. Proc. SPIE, 4144, 2, 174-182. 6. G. J. Havrilla and T. Miller. Powder Diffraction 19 (2), 24, 119-126. 7. C. M. Sparks, P. Lysaght, T. Rhoad. Powder Diffraction 2 (2), 25, 161-164. 8. K. Choi, P. Lysaght, H. Alshareef, C. Huffman, H.-C. Wen, R. Harris, H. Luan, P.-Y. Hung, C. Sparks, M. Cruz, K. Matthews, P. Majhi, and B. H. Lee. Thin Solid Films 486, 25, 141-144.