Effect of Co-60 Single Escape Peak on Detection of Cs-137 in Analysis of Radionuclide from Research Reactor. Abstract

Similar documents
M.Cagnazzo Atominstitut, Vienna University of Technology Stadionallee 2, 1020 Wien, Austria

Depth Distribution of H-3, C-14 and Co-60 in Decommissioning of the Biological Shielding Concrete of KRR-2

Gamma-Spectrum Generator

Introduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48

Determination of the activity of radionuclides

PARAMETERISATION OF FISSION NEUTRON SPECTRA (TRIGA REACTOR) FOR NEUTRON ACTIVATION WITHOUT THE USED OF STANDARD

The Best Gamma-Ray Detector

Journal of Radiation Protection and Research

He-3 Neutron Detectors

anti-compton BGO detector

Compton suppression spectrometry

EFFICIENCY SIMULATION OF A HPGE DETECTOR FOR THE ENVIRONMENTAL RADIOACTIVITY LABORATORY/CDTN USING A MCNP-GAMMAVISION METHOD

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools

ACTIVATION ANALYSIS OF DECOMISSIONING OPERATIONS FOR RESEARCH REACTORS

Trace Element Analysis of Geological, Biological & Environmental Materials By Neutron Activation Analysis: An Exposure

Determination of the boron content in polyethylene samples using the reactor Orphée

TECHNICAL WORKING GROUP ITWG GUIDELINE ON LABORATORY APPLICATIONS OF HIGH-RESOLUTION GAMMA SPECTROMETRY

Validation of the MCNP computational model for neutron flux distribution with the neutron activation analysis measurement

IDENTIFICATION AND QUANTIFICATION OF RADIONUCLIDES IN HISTORICAL WASTE AT ANSTO

Seaborg s Plutonium?

Quartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays

Journal of Radiation Protection and Research

EFFICIENCY AND RESOLUTION OF GERMANIUM DETECTORS AS A FUNCTION OF ENERGY AND INCIDENT GEOMETRY

Detection and measurement of gamma-radiation by gammaspectroscopy

Problem P7. Stéphanie Ménard. Dosimetry Department Fontenay-aux FRANCE IRSN QUADOS IRSN

Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the WBC

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

arxiv:nucl-ex/ v2 21 Jul 2005

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

"Neutron Flux Distribution"

INSTRUMENTAL NEUTRON ACTIVATION ANALYSIS (INAA)

Activities of the neutron standardization. at the Korea Research Institute of Standards and Science (KRISS)

RADIOLOGICAL CHARACTERIZATION Laboratory Procedures

The first model was based only on the CANBERRA information which we. drawing. Canberra refused any other information.

Photofission of 238-U Nuclei

Environmental Applications

DETERMINATION OF CORRECTION FACTORS RELATED TO THE MANGANESE SULPHATE BATH TECHNIQUE

Procedure for determining radionuclides in foodstuffs at elevated levels of contamination by gamma spectrometry

Radioactivity of the Treated Topaz

Hee Dong Choi', Soo Hyun Byun Department of Nuclear Engineering, Seoul National University, Seoul , Korea. and

The Ones That Got Away: Neutron Leakage Spectra

An introduction to Neutron Resonance Densitometry (Short Summary)

The IAEA-CU world wide open proficiency test on the determination of radionuclides in soil, spinach and water

The Use of Self-Induced XRF to Quantify the Pu Content in PWR Spent Nuclear Fuel

Positron Annihilation Spectroscopy

Maria Ângela de B. C. Menezes. Radojko Jaćimović. Cláubia Pereira

VERIFICATION OF MONTE CARLO CALCULATIONS OF THE NEUTRON FLUX IN THE CAROUSEL CHANNELS OF THE TRIGA MARK II REACTOR, LJUBLJANA

THALES Project No. 65/1205

24th Seismic Research Review Nuclear Explosion Monitoring: Innovation and Integration

CALCULATION OF ISOTOPIC COMPOSITION DURING CONTINUOUS IRRADIATION AND SUBSEQUENT DECAY IN BIOLOGICAL SHIELD OF THE TRIGA MARK ΙΙ REACTOR

QUANTITATIVE Cs-137 DISTRIBUTIONS FROM AIRBORNE GAMMA RAY DATA

GAMMA RAY SPECTROSCOPY

Identification of Naturally Occurring Radioactive Material in Sand

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

MEASUREMENT OF SPENT FUEL ASSEMBLIES IN SPRR-300

EXPERIMENTAL DETERMINATION OF THE URANIUM ENRICHMENT RATIO

QUIZ: Physics of Nuclear Medicine Atomic Structure, Radioactive Decay, Interaction of Ionizing Radiation with Matter

Title: Assessment of activity inventories in Swedish LWRs at time of decommissioning

Application of prompt gamma activation analysis with neutron beams for the detection and analysis of nuclear materials in containers

ISO INTERNATIONAL STANDARD

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

Utilization of the Irradiation Holes in HANARO

Experience with different methods for on- and off-line detection of small releases of fission products from fuel elements at the HOR

A Germanium Detector with Optimized Compton Veto for High Sensitivity at Low Energy

1 cm. Cu electrode. Ge crystal. end cap. Dead layer. crystal cup

Chem 481 Lecture Material 4/22/09

Modern Physics. Laboratory Experiment. Compton Scattering. Boston University International Program. Technische Universität Dresden

Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the UAL

Preparation of Standard Source as a Petri Dish for Plant by Using

Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277

Quality Assurance. Purity control. Polycrystalline Ingots

Science of Nuclear Energy and Radiation a Comprehensive Course for Science Teachers June 22-25, 1998 McMaster University

ENT OF THE RATIO OF FISSIONS IN U TO FISSIONS OF. IN U USING 1.60 MEV GAMMA RAYS THE FISSION PRODUCT La 14 0 MEASUREM

DIRECT EXPERIMENTAL TESTS AND COMPARISON BETWEEN SUB-MINIATURE FISSION CHAMBERS AND SPND FOR FIXED IN-CORE INSTRUMENTATION OF LWR

Chapter 8 Hyper-Pure Germanium Detector

STUDY OF NEUTRON IRRADIATION-INDUCED COLOR IN TOPAZ AT THE PULSED REACTOR IBR-2. Abstract

COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS

Chapter 8 Hyper-Pure Germanium Detector

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

da u g ht er + radiation

Gamma background measurements in the Boulby Underground Laboratory

IAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES

High-energy calibration data for neutron activation analysis

SENSITIVITY ANALYSIS OF ALLEGRO MOX CORE. Bratislava, Iľkovičova 3, Bratislava, Slovakia

THE COMPTON EFFECT Last Revised: January 5, 2007

A Method to Determine Doublet Photopeak Area

The Mössbauer Effect

A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate

A dual scintillator - dual silicon photodiode detector module for intraoperative gamma\beta probe and portable anti-compton spectrometer

NUCL 3000/5030 Laboratory 2 Fall 2013

Determination of research reactor fuel burnup

Mass Yield Distribution in the Photon-induced Fission of 232 Th, 238 U, nat Pb, and 209 Bi

Control of the fission chain reaction

MONTE CALRLO MODELLING OF VOID COEFFICIENT OF REACTIVITY EXPERIMENT

SECTION 8 Part I Typical Questions

Multi Channel Analyzer (MCA) Analyzing a Gamma spectrum

Neutron activation analysis. Contents. Introduction

Library of uranium and plutonium reference spectra Introduction

arxiv: v1 [physics.ins-det] 29 Jun 2011

Transcription:

Organized and hosted by the Canadian Nuclear Society. Vancouver, BC, Canada. 2006 September 10-14 Effect of Co-60 Single Escape Peak on Detection of Cs-137 in Analysis of Radionuclide from Research Reactor Myong-Seop KIM *1 and Sang-Jun PARK 1 1 Korea Atomic Energy Research Institute, 150 Dukjin-Dong, Yuseong, Daejeon, 305-353, Korea Abstract The effect of the single escape peak of 1173 kev gamma-rays from Co-60 on the detection of Cs-137 activity is analyzed. The single escape peak of 1173 kev gamma-rays from Co-60 is located at the 662 kev, which is very close to the energy of gamma-rays from Cs-137. This single escape peak may be mistaken for the gamma-ray peak from Cs-137 activity in the case of large area of 1173 kev peak. The detection of Cs-137 is very important to the judgment of the contamination or the leakage of the material containing the fission product like reactor pool water and in the several experiments for reactor physics such as burn-up estimation. In this work, the areas of the single escape peak of the 1173 kev gamma-rays from Co-60 are measured with several full energy peak areas by using the HPGe detector. The critical limit by which we can decide whether the net count of 662 kev peak due to Co-60 would be significant or not is deduced. For this detection system, when the area of full energy peak is larger than 4.5 million, the single escape peak of 1173 kev gamma-rays from Co-60 can be regarded as the single significant peak. Therefore, it is confirmed that the detection of the Cs-137 activity is affected by the Co-60 in this case. Conservatively, for this detection system, it is recommended that the area of 1173 kev peak of Co-60 would be less than 2 million for neglecting the effect of Co-60. KEYWORDS: Co-60, Cs-137, Escape peak, HPGe detector, Research reactor, Critical limit 1. Introduction The Cs-137 isotope that emits the gamma-rays with almost unique energy of 661.660 kev is a representative radionuclide originated from the nuclear fission. It is very useful isotope in the various experimental reactor physics such as burn-up estimation of the nuclear fuel. Therefore, the detection of Cs-137 activity is very important in the operation of nuclear facility such as research reactor and in the evaluations of nuclear facility accident.[1] The Co-60 isotope is also produced in the significant amount by the neutron activation in the nuclear reactor. It emits the prevailing two gamma-rays with energies of 1173.238 and 1332.502 kev. Since the energies of these gamma-rays are larger than 1022 kev, the single escape(se) and double escape(de) peaks * Corresponding author, Tel. 82-42-868-8666, Fax. 82-42-868-8341, E-mail: mskim@kaeri.re.kr C2139 1/8

can appear on the gamma-ray spectrum of Co-60. There are very few measurements of these escape peaks because of very low pair production probability of Co-60 gamma-rays. The centroid energy of the single escape peak of 1173 kev gamma-rays is very near to that of gamma-ray peak from Cs-137. Considering the energy resolution of the detection system, the uncertainty of the energy calibration and the Doppler broadening of the single escape peak, it is highly probable that the single escape peak of 1173 kev gamma-rays from Co-60 gives the misjudgment for the existence of the Cs-137 and the interference for the area determination of the Cs-137 gamma-ray peak.[2] Actually, we had collected the water from a beam tube for the neutron application in HANARO, 30 MW research reactor, and in order to confirm the origin of that water, the radionuclide in the water had been analyzed. In the gamma-ray spectrum of the water measured using HPGe detector, not only very high peak at 1173 kev due to Co-60 but also very small peak near to the energy of 662 kev had been discovered. If this peak at 662 kev was originated from the Cs-137 activity, there was some doubt about whether the beam tube was reliable. Fortunately, this peak could be originated from the Co-60 as the single escape peak of 1173 kev gamma-rays. Therefore, in this work, we analyzed the effect of the single escape peak of 1173 kev gamma-rays from Co-60 on the detection of Cs-137. And then, we set the critical limit by which we can decide whether the net count of 662 kev peak due to Co-60 would be significant or not. 2. Radionuclide Analysis for Water from Beam Tube HANARO has 7 horizontal beam tubes for various neutron beam applications. Fig. 1 shows the schematic view of the HANARO beam tube. The nose of the beam tube is located at a position of heavy water reflector tank, and it passes through the heavy water tank, the light water pool and the biological shield. In order to monitor the leakage of the water, the moisture leak detector has been installed at the front of the beam exit. The moisture gathered through the drain piping can activate the detector. We can judge the reliability of the beam tube from whether this water contains the radionuclide in the water from pool of the reactor core or reflector tank. Therefore, we measured the gamma-ray spectrum of the water with HPGe detector for a long time to identify even small peaks. Fig. 2 shows the gamma-ray spectrum of the water gathered in the moisture detector. Most of the nuclide shown in the spectrum are generated by the neutron activation of the structural materials of the beam tube such as stainless steel, and they are not related to the nuclear fission. However, when we see the detail of the spectrum near 660 kev as shown in the figure, the small peak at the 662 kev can be found. The commercial gamma-ray spectrum analysis program had regarded this as gamma-ray peak with even low peak search sensitivity. The area of the 1173 kev peak is 4.5 million, and that of the 662 kev peak is 2366±725. The most important source of the 662 kev gamma-rays is the Cs-137 isotope. There are few ways to produce the Cs-137 without nuclear fission, i.e., the detection of the Cs-137 means that the water could be originated from the light water pool of the reactor core. The reactor pool water may contain small amount of Cs-137 due to the fission of the contaminated uranium on the fuel surface. C2139 2/8

Figure 1: Schematic view of the HANARO beam tube. Light water Heavy water Reflector vessel Bellows Collimator Biological shield Beam port Graylock type connector Rotary shutter Moisture leak detector Figure 2: Gamma-ray spectrum of the water gathered in the moisture detector of beam tube. Counts/channel 10 6 10 5 10 4 Counts/unit energy 17000 16500 16000 15500 320 kev from Cr-51 511 kev 603 kev from Sb-124 724 kev from Zr-95 757 kev from Zr-95 766 kev from Nb-95 811 kev from Co-58 889 kev from Sc-46 1099 kev from Fe-59 1116 kev from Zn-65 1121 kev from Sc-46 1173 kev from Co-60 1292 kev from Fe-59 1333 kev from Co-60 15000 650 655 660 665 670 675 Energy (kev) 10 3 500 1200 1900 2600 3300 4000 Channel number The other special feature of the above spectrum is very high gamma-ray peaks from Co-60. Co-60 can be produced by the neutron activation in the beam tube of the research reactor. The single escape peak of 1173 kev gamma-rays from Co-60 is located at the 662 kev, which is very near to the energy of gamma-rays from Cs-137. Although the build-up probability of single escape peak of 1173 kev is very small, we may mistake this single escape peak for the gamma-ray peak from Cs-137 in the case of very large area of 1173 kev full energy peak. C2139 3/8

3. Experimental Methods The detector used in this work is a closed-ended coaxial HPGe detector, and its specifications are given in Tab. 1. The gamma-ray spectroscopy system was set up, and the shaping time of the spectroscopy amplifier was set at 6 μsec. The Co-60 gamma-ray spectra with various full energy peak areas were obtained by using the HPGe detector and the standard sources. An example of the spectra is shown in Fig. 3. The source-to-detector distance was 25 cm. The dead time of the detection system was less than 5%. Table 1: Specifications of the HPGe detector. Relative efficiency Resolution Peak to Compton ratio, Co-60 Crystal diameter Crystal length Al end cap thickness Inactive Ge thickness End cap to crystal Detector bias voltage 15 % 1.80 kev(fwhm) at 1.33 MeV 0.825 kev(fwhm) at 122 kev 44 55.0 mm 37.2 mm 1.27 mm 700 μm 3 mm +2600 V Figure 3: Photon spectrum of Co-60 obtained with the HPGe detector. 10 7 Counts/unit energy 10 6 10 5 10 4 10 3 DE peak (1173 kev) DE peak (1332 kev) SE peak (1173 kev) SE peak (1332 kev) FE peak (1173 kev) FE peak (1332 kev) 10 2 100 400 700 1000 1300 1600 Energy [kev] In the above spectrum, the areas of full energy(fe) peaks of 1173 and 1333 kev gamma-rays C2139 4/8

are 5.3 and 4.7 million, respectively. The single and double escape peaks of 1333 kev gamma-rays and the double escape peak of 1173 kev gamma-rays are clearly resolved. However, the single escape peak of 1173 kev gamma-rays is fairly collapsed due to the small peak area and the Doppler broadening. If the smaller detector is used, the larger and more apparent escape peaks will be represented because the escape probability of the annihilation photon is increased. When the peak area was calculated, in order to estimate the background beneath the peak, m channels beyond each side of the peak region were used as follows.[3] U L 1 U + m A = Ci n + / 2m, (1) i= L i= L m i= U + 1 where, C i are the counts in the ith channel, and n is the number of channels within the peak region. The critical limit by which we can decide whether the net count of a peak is significant or not, for 95% confidence, is given by L C + 1/ 2 = 1.645[ B(1 n / 2m)], (2) where, B is the background count. In the analysis of 662 kev peak, n and m were equal to 21 and 3, respectively. 4. Results Fig. 4 shows the portion of interest in two spectra with different full energy peak area at 1173 kev. Through the long-term detection of background, it was confirmed that the effect of natural background was negligible. From the figure, it is confirmed that when the full energy peak area is several millions, the single escape peak of 1173 kev gamma-rays from Co-60 at 662 kev looks like a single peak which is statistically significant. For the case of full energy peak area below one million, it is difficult to find the explicit gamma-ray peak near the 662 kev. Tab. 2 shows the experimental result and the critical limit obtained by using the measured Co-60 gamma-ray spectra. Since the 662 kev peak is located on the high Compton continuum of the 1173 and 1332 kev gamma-rays from Co-60, the gross count of the peak region is rather big in comparison with the net count of the peak. Therefore, the uncertainty in the determination of the area of 662 kev peak is fairly large while that in the case of 1173 kev full energy peak is negligible. The last column of the table, the ratio of the areas of the single escape and full energy peaks, depends on the characteristics of the detection system, mainly the size of the detector.[4] The weighted average for the last four values in this column is 0.000655. This value becomes smaller for larger detector, i.e., the area of the single escape peak of the Co-60 becomes smaller for larger detector. Thus, it is advantageous to adopt the large detector in the simultaneous detection of the Co-60 and Cs-137 in order to reduce the effect of the single escape peak of the 1173 kev gamma-rays on the detection of the Cs-137. C2139 5/8

Figure 4: A portion of the Co-60 gamma-ray spectra showing the region of the single escape peak of 1173 kev gamma-rays. 28000 Counts/unit energy 26000 24000 3500 SE peak of 1173 kev gamma-rays 1173 kev peak area : 6.3x10 6 1173 kev peak area : 7.8x10 5 2500 630 640 650 660 670 680 690 Energy [kev] Table 2: Experimental result and the critical limit obtained by using the measured Co-60 gamma-ray spectra. 1173 kev 662 kev peak area peak area Gross Net Deduced critical limit Ratio of peak areas(se/fe) 313350 25335 485±241 550 0.001548 782848 62601 671±381 869 0.000857 1755004 107136 669±499 1139 0.000381 3758085 307918 2172±875 1930 0.000578 4741680 373273 3573±930 2122 0.000754 6318229 497531 4278±1074 2451 0.000677 9400921 663275 5848±1240 2830 0.000622 Fig. 5 shows the deduced critical limit and the single escape peak area according to the area of the 1173 kev full energy peak. The critical limit apparently becomes smaller than the 662 kev peak area, when the 1173 kev peak area is over about 4.5 million, considering the uncertainty of the net area. Thus, when the area of full energy peak is larger than 4.5 million, the single escape peak of 1173 kev gamma-rays from Co-60 can be regarded as the single peak which is statistically significant. Therefore, it is confirmed that the detection of the Cs-137 activity is affected by the Co-60 in case the area of the 1173 kev gamma-ray peak is larger than 4.5 million. Conservatively, it is recommended that the area of 1173 kev peak of Co-60 would be less than 2 million for neglecting the effect of Co-60. Using the above result, the detection limit or C2139 6/8

sensitivity of Cs-137 can be set up for each detection system. Figure 5: Deduced critical limit and the single escape peak area according to the area of the 1173 kev full energy peak. 6000 5000 : Deduced critical limit : Net peak area 662 kev peak area 4000 3000 2000 1000 0 0 2x10 6 4x10 6 6x10 6 8x10 6 1x10 7 1173 kev peak area Therefore, from the above work, it is confirmed that the 662 kev peak shown in Fig. 2 is originated from a large amount of 1173 kev gamma-rays from Co-60, i.e., no doubtful nuclide about leakage of reactor pool water is found in the water collected from the beam tube of HANARO. 5. Conclusion For the HPGe detector used in this work, when the area of full energy peak is larger than 4.5 million, the single escape peak of 1173 kev gamma-rays from Co-60 can be regarded as the single significant peak. Therefore, it is confirmed that the decision for existence or quantitative analysis for Cs-137 activity are not sure in the simultaneous measurement with Co-60 giving rise to a large amount of full energy peak area. By using this work, simultaneous detection technique of Co-60 and Cs-137 without interference may be deduced. And, this work is expected to be helpful for the evaluation of reliability for the application facility of the research reactor and for precise determination of Cs-137 activity in the various experimental reactor physics. References 1) H. L. Oczkowski et al, Chernobyl Fall out in Salt from Ciechocinek, Poland, Radiation Measurements, 26, 743 (1996). 2) I. K. Mackenzie and J. L. Campbell, On the Use of the Single Escape Peak in Ge(Li) C2139 7/8

Spectroscopy, Nuclear Instruments and Methods, 101, 149 (1972). 3) G. Gilmore and J. D. Hemingway, Practical Gamma-Ray Spectrometry, John Wiley & Sons, Chichester, 114 (1995). 4) C. S. Park, G. M. Sun and H. D. Choi, Determination of Single Escape and Double Escape Peak Efficiency for a HPGe Detector, Journal of the Korean Nuclear Society, 35, 523 (2003). C2139 8/8