IDENTIFICATION AND QUANTIFICATION OF RADIONUCLIDES IN HISTORICAL WASTE AT ANSTO
|
|
- Derick Golden
- 5 years ago
- Views:
Transcription
1 IDENTIFICATION AND QUANTIFICATION OF RADIONUCLIDES IN HISTORICAL WASTE AT ANSTO McOrist G D., Bowles C.J., Fernando K. and Wong R. Australian Nuclear Science and Technology Organisation Australia Abstract Low level radioactive solid waste arising from research and production activities at ANSTO is currently held in storage for final disposal. This waste is packaged in 200L steel drums and is held in a designated radioactive waste storage facility. Most of such drums have been counted in a commercial Canberra Q 2 low level waste assay system to radiologicaly characterise them. The resulting spectra have been evaluated by an experienced gamma-ray spectrometrist to ensure that all significant peaks present have been correctly identified and that the quantity of each resulting radionuclide has been correctly calculated. The validation process highlighted a number of areas for improvement in the original method used to count each drum as well as in the analysis software supplied with the gamma-ray spectrometer. Some of the problems encountered included unidentified and misidentified peaks as well as errors associated with quantifying the respective nuclides. At present, accurate and reliable gamma spectrometry results for well over 5000 drums has been produced. The availability of validated gamma ray spectrometry results of waste has enabled decisive classification waste and subsequent processing. 1. Introduction Low level radioactive solid waste arising from research and production activities over the past 50 years is currently held in on the Australian Nuclear Science and Technology Organisation (ANSTO) site at Lucas Heights. The resulting radioactive waste contains a wide range of radionuclides with half-lives varying from about a year to thousands of years and emits alpha, beta and/or gamma radiation. This waste is handled and processed according to its physical form (solid or liquid) and half-life. Generally, low level radioactive solid waste was stored in red 200L steel drums. This waste usually consisted of paper, tissues, plastics (gloves, bottles, sheeting), metals, mineral material (process waste, grit blast, soil) and glass. Over 6000 drums of low and intermediate level solid waste are currently stored at Lucas Heights. The radioactivity present in these drums has been determined by gamma-ray spectrometry. 2. Gamma-Ray Spectrometry In December 1996 a commercial Canberra Q 2 low level waste assay system was purchased by the Waste Operations Section at ANSTO to determine the identity of and quantify gamma emitting radionuclides present in 200L drums of waste stored at ANSTO. The Canberra Q 2 system consists of a large shielded cabinet in which 200 L drums of waste containing very low levels of radioactivity are placed for scanning [see Figure 1.]. During this process a base plate supporting the drum revolves at a nominal 10 revolutions per minute, exposing the drum to three HP-Ge, co-axial detectors mounted longitudinally within the counting space of the cabinet. Only drums with relatively low total radioactivity were suitable for counting in the Q 2 system. As a rule of thumb, this was indicated by a contact dose rate measurement of less than 50 µsv/h. Each drum was nominally counted for 600 seconds live time. The resulting spectrum was automatically analysed by Canberra Genie 2000 software using empirical efficiency calibrations to determine the concentration of each gamma emitting radionuclide present in the drum. A hard copy of this data was stored in appropriate folders and an electronic version was stored on the counter computer.
2 A closer examination of this data indicated that in many cases identification problems had occurred. In some spectra some of the peaks present had been incorrectly identified and in others peaks actually present had not been identified at all. In others the peaks had been correctly identified but the calculation of the weighted average mean concentration of the nuclide was incorrect. Still in others, high Compton Background at the 2000 kev end of the spectrum indicated another problem. Figure 1: Schematic diagram of the Canberra Q 2 low level waste assay system Some of these errors could be attributed to the following: 3.1 The energy calibration for drums counted between January 1997 and the end of October 1997 had been performed using only Cs-137 and Co-60 calibration sources. Although this meant that radionuclides with gamma-ray energies greater than about 200 kev were correctly identified those with lower energies such as Am-241, Co-57 and Eu-155 were commonly missed. 3.2 The Genie 2000 software had assigned a region of interest (ROI) to an energy where a peak might be expected to be but no statistical peak was present (ie essentially background). The presence of the nuclide and the resulting activity calculation was therefore incorrect. 3.3 Occasionally even when peaks had been correctly identified the concentration of the resulting nuclide was incorrect. One or more of the peaks used for concentration calculation had an interfering peak from another nuclide located near enough for the software to unable to separate. In many cases the presence of other related nuclides such as in uranium and thorium decay chains confirmed that a problem was occurring in these cases. 3.4 The drum had been counted too soon and the resulting spectrum contained nuclides with relatively short half-lives (ie less than about 30 days. One of the more common methods for determining the identity of unknown peaks in a spectrum is to search libraries for nuclides with longer half-lives only. The presence of nuclides with short half-lives significantly complicated this process.
3 3.5 The high Compton Background at the 2000 kev end of the spectrum was regular indicator of a high % deadtime during counting due to the elevated activity of one or more radionuclides in that drum. Some of the resulting problems included peak shift making identification difficult and loss of peak counts. 3. Correcting Spectra Counting Errors Before the spectra could be studied in detail these errors had to be corrected. When opened, each spectrum was evaluated to determine which corrective measures were required. In some cases more than one corrective measure was required. In others, the spectrum indicated that the original count was inappropriate and the drum was scheduled for recounting. When significant low energy peaks had not been identified the spectrum was recalibrated using the energy calibration of a drum counted after October 1997 (ie one that included Am-241, at 59 kev). This enabled these low energy peaks to be correctly identified. In some cases there were sufficient known peaks in the spectrum to allow recalibration to take place without the need of external data. The problem of assigning an ROI where no peak was present was corrected by the choice of appropriate analysis libraries during the actual spectral analysis step [see 4.1]. When the concentration of a particular nuclide was found to be incorrect it was also corrected during spectral analysis. If the spectrum of a drum indicated that it had been counted too soon after packing (ie short half-life nuclides such as Sc-46, Fe-59, Nb-95, Zr-95, etc were present) it was put aside for recounting. In the case of a spectrum where the original count had a high dead time that drum was also scheduled for recounting at a later time. Investigation into the effect of high dead time on quantification of radioactivity by the Q 2 system had recommended that spectra with deadtimes greater than 35% should not be considered for analysis [1]. The spectra of drums above this limit were not processed but set aside for counting on another drum counting system suitable for counting higher activity drums. After these problems had been addressed in the spectra of drums not requiring recounting the gamma-ray spectrometrist was able to correctly identify major peaks present and correctly calculate the concentration of each gamma emitting nuclide present in the drum. 4. Techniques for Analysing Spectra 4.1 Standard methodology The method used for correctly processing (ie analysing or validating) an individual spectrum developed over time and become relatively standardised. This enabled individual Instructions for spectrum calibration and analysis to be written. The original electronic version of each spectrum was recalled and saved on to the computer containing Canberra Genie 2000 software (in Bld 20B). When the recalled spectrum was opened the peaks present were displayed. An option in the spectrum menu allowed a copy of the original printed report to be displayed (Notepad version). Occasionally if the spectrum was relatively simple (eg contained only a few peaks/nuclides) this report could be accepted as correct and the resulting spectrum was transferred to a Spectrum Reviewed folder. However in the majority of cases the spectrum indicated that at least one analysis error that had to be corrected. In many of these the identity and/or concentration of a nuclide known to be present was incorrect. One of the main reasons for this was that the library used for the original analysis contained over 80 individual nuclides. The result was a significantly increased likelihood that a peak could have two or more possible identities that the software could not resolve.
4 In most cases the creation of more appropriate spectra analysis libraries, based on the major component of radioactivity present solved this problem. Some libraries were prepared that contained mainly reactor based nuclides while others consisted of the natural radionuclides of uranium and thorium. Over time about 10 Standard Primary nuclide analysis libraries were created that contained specific nuclides likely to be present in drums containing particular kinds of waste. For example, drums containing waste that had originated from HIFAR (Reactor) related activities contained fission product and activation nuclides such as Cs-137, Eu-152, Eu-154, Cs-134, Sb-125, Ag-108m, and so on. Drums containing mine process waste contained nuclides associated with uranium and thorium progenies such as Pa-234m, Pb-214, Ac-228, Tl-208 etc. An educated choice of nuclide library enabled the gamma-ray spectrometrist to choose that most appropriate library for reanalysis. When the spectrum was reanalysed using the appropriate Standard Library any significant peak(s) that were not identified by the software were found in the Unidentified Peaks section of the analysis printout. As a guide these were indicated by a peak size of 2-3 counts per second (or more) and/or a Peak CPS % Uncertainty of about 3% (or less). The most effective method of identifying unknown peak was the compilation of a database containing commonly unknown or misidentified peaks, which contained nuclide specific information such as peak energy, nuclide, half-life and abundance of unidentified photon peaks of nuclides commonly found after reanalysis. Throughout the spectra analysis process, this database was continually expanded and updated to include other problematic peaks successfully identified by analysing subsequent drum spectra. Table 1 shows a section of this database showing some problematic peaks at low energy levels. When a peak did not appear in this database, there were a number of alternative methods that could be used. For more in-depth searches two other sources of gamma-ray nuclide data were used Nuclear Data Tables in book form [2,3] and computer software search programs [4,5,6]. However although these methods allowed the correct identification of many obscure and unusual nuclides present in waste drums, their use was significantly complicated by a number of factors. For example, the hard copy version [2] lists nuclides that have a peak of almost any abundance at that particular energy. Also in spectrum being studied a peak may span 4 kev (ie 2 kev either side of its centroid). This could mean evaluating 120 or more possible nuclides if the unknown is a relatively lower energy peak. For these reasons it was necessary to eliminate unlikely nuclides based on such criteria as half-life, other energies from the same nuclide and abundance. Table 1 Unknown or misidentified peaks commonly found after reanalysis (section only) Energy (kev) Radionuclide Half-life % Abundance Eu years Co days Eu years Ce days Se days Co days Te-123m 120 days Sb years Ho-166m Ho-166m Pb-212 (natural) Pb-214 (natural) 7.5 Alternately, computer software search programs were used to make the search simpler by allowing the operator to adjust cut-off parameters such as energy range, half-life and abundance. However this search still resulted in a large number of possible nuclides that had to be individually evaluated by the experienced gamma ray spectrometrist. The spectrometrist analysing the spectra needed to be aware of some potential problems when using computer search programs such as incorrectly specifying the cut-off parameters that possibly eliminated the real nuclide and peak libraries that may have had old or incorrect data (eg Pa-234) making nuclide identification impossible.
5 Over time it was possible for gamma-ray spectrometrist to gain familiarity with the energies of many common unknown peaks and the associated nuclide data that may assist in identification. A balanced mix of intuitive guess and the use of hard copy tables and/or computer search programs proved to be the most effective procedure for identifying unknown peaks. Another factor that significantly affected the ability to correctly identify a radionuclide in a waste drum was the concentration of that nuclide. The most common method of confirming the presence of a nuclide was to locate the second and/or third most abundant peak for that nuclide. If the activity was sufficiently low that these were not seen an alternate method was required. In some cases the presence of another nuclide, such as a progeny of uranium or thorium, helped confirm the identity of that nuclide. When peak interference resulted in an incorrect calculation of radionuclide concentration, selectively changing the analysis library to remove the interfering peak was usually successful. For drums suspected of containing an unusually high level of a particular nuclide (such as when the most abundant peaks indicate thousands of kbq of that nuclide) the analysis library was adjusted to contain a larger number of less abundant peaks reducing the problem of peak misidentification. 4.2 Common spectra identification problems During the process of validating over 5000 gamma-ray spectra it was common to find that some peaks (and therefore nuclides) had been incorrectly identified. Some examples were regularly seen in drums after they were processed. In some spectra the 122 kev peak was occasionally misidentified. The radionuclides Eu-152 (121.8 kev) and Co-57 ( kev) were sufficiently close in energy for this to occur. The presence (or absence) of other Eu-152 peaks usually enabled confident identification. In some cases if the level of cyclotron-produced Co- 57 was high enough the kev peak could also be seen (even if not quantified). The presence of a 1274 kev peak usually indicated that Eu-154 (the result of activation of Eu in HIFAR) was present in the waste drum. However this peak could have also resulted from Na-22 (cyclotron produced) being present. The presence (or absence) of other Eu-154 peaks (such as 723 or 123 kev) usually enabled confident identification. The 351 kev peak found in a waste drum spectrum was usually attributed to the most abundant peak of Pb- 214, the naturally occurring progeny in the U-238 decay chain. All Pb-214 (half-life 28.8 minutes) present must be supported by the long half-life parent, Ra-226 (1600 years). If this was the case, another progeny, Bi-214, must also be present. The most abundant peak of Bi-214 occurs at 609 kev and its presence confirms Pb-214. The absence of the 609 kev peak indicated that Bi-211 (from the U-235 chain) was present. In this case the progenies of long half-life Ac-227 (21.8 years) such as Ra-223, Rn-219 or Pb-211 usually confirmed this. 4.3 Some particularly challenging identification examples Although the identification of majority of significant peaks present in gamma spectra enabled the confident identification and concentration of radionuclides present, a few peaks (and therefore nuclides) proved difficult to identify. In these cases significant extra effort was fruitful while in a few others the peaks remained unidentified. Initial efforts to identify the 1592 kev peak proved unsuccessful. However these drums had significant amounts of Th-232 progenies that appeared to be in secular equilibrium. After some concerted searching the most abundant peak of Tl-208 was found to be 2614 kev and that the 1592 kev peak was the resulting double escape peak. Since the counting and analysis software produced a spectrum that only covered the energy range kev the 2614 kev peak was never seen. Two other peaks at and kev were very difficult to identify. The reason was that the only realistic possibility, Bi-213, had a half-life of only 46 minutes. It was only when statistically significant amounts of Fr-221 were also found in some drums that the link with Bi-213 was established. Both are part of the Np-237
6 decay chain and are actually supported by Th-229. Some degree of confirmation came when the resulting concentration values of these two nuclides agreed closely with each other. The 1157 kev peak was also occasionally seen but was unidentified by analysis software. However the more abundant peaks of the most likely nuclides, Ta-182 or Bi-214, were not present. The presence of only very low levels of other nuclides did not provide any clues. The only nuclide that was a realistic possibility, Sc- 44, had a half-life of only 3.9 hours. More detailed study showed that its parent, Ti-44, had a long half-life (63 years) but no gamma emitters and was supporting the Sc-44. When Np-239 and/or Cm-243 were present the resulting gamma-ray spectra were very complex not only as a result of progeny products but also from other radionuclides (eg actinides) present in the same drum. The problem is that both nuclides have very long half-lives and the most abundant peaks in both nuclides not only have almost identical energies but also very similar abundances. Differentiation between these two nuclides is probably only possible using the peaks, 315 and 334 kev that are only present in Np-239. A technique for accurate identification and quantification of these nuclides is currently being developed. The kev peak was found in only one drum that contained relatively low amounts of a few other nuclides. The most likely nuclides such as Eu-152, Co-57 and Eu-154 were found to be not likely since other more abundant peaks in the case of both Eu nuclides were not present. Also this peak was noticeably far enough away from the required energies to be realistically considered. A recent recount of this drum failed to shed any light on the mysterious nuclide. Its current identity remains a bit of a mystery. Still another peak at kev peak has been seen in a couple of drums but its identification is still proving difficult. Further study into this peak is taking place. 5. Conclusions The process of successfully validating the spectra of drums of low-level waste stored at highlighted a number of deficiencies that had occurred during the original count. Some corrective measures were relatively simple while others were significantly complex requiring a large amount of operator time and expertise. In most cases effective spectrum recalibration and other corrective measures resulted in a spectrum that could be successfully processed at a later time. Drums containing short half-life nuclides or high activity were set aside for more appropriate counting at a later time. The process of validating over 5000 drum spectra enabled an effective standardised analysis methodology to be established. The experienced gamma-ray spectrometrists used a combination of techniques to correctly identify and quantify nuclides present. These included books containing nuclear data, computer identification software packages and experience. In many cases the creation of a more appropriate nuclide analysis library resulted in the validation of these spectra. The identity of a couple of peaks proved very challenging. In some cases after significant time and effort these were eventually identified and in some cases quantified. However, even after careful and detailed evaluation of some spectra the confident identification of some peaks still remains a mystery. In conclusion, this process lead to confident identification and quantification of all gamma-emitting nuclides present in the vast majority of drummed low level radiative solid waste stored at ANSTO. The radionuclide information collected will enable accurate classification of waste, and hence facilitate the formulation and selection of conditioning techniques and final disposal options. 6. References 1. R.K.Barnes, C.Bowles, K.Fernando, L.Mokhber-Shahin, D Maher and S.Auld, Review of Gamma Spectral Characterisation Techniques Used on Low Level Solid Waste at ANSTO (WOTD/TR22) 2. Atomic Data and Nuclear Data Tables Vol. 29, No.1, 1983, pp
7 3. Atomic Data and Nuclear Data Tables Vol. 29, No.2, 1983, pp Hacker C., Radiation Decay Version 3.6, May Gamma Ray Spectrum Catalogue 4th edition, September ORTEC Nuclide Navigator Version 3.4, June 2000.
EPRI Project. Hard-to-Measure Nuclides in Effluents
EPRI Project Hard-to-Measure Nuclides in Effluents Jim Breeden CN Associates RETS-REMP Workshop & EPRI Groundwater Protection Workshop June 25-27, 2013 Westminster, Colorado Definitions: Hard-to-Detect,
More informationInvestigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the WBC
Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the WBC A. Specification Whole body counting method is used to detect the gamma rays emitted by radio nuclides,
More informationNDA Analysis of Legacy INL Wastes for disposal at WIPP D.C. Warner, R.N. Ceo, D.E. Gulbransen Canberra Industries, Inc.
NDA Analysis of Legacy INL Wastes for disposal at WIPP D.C. Warner, R.N. Ceo, D.E. Gulbransen Canberra Industries, Inc. Abstract This paper discusses Nondestructive Assay (NDA) of legacy radioactive wastes
More informationGamma Analyst Performance Characteristics (MDAs)
Application Note Gamma Analyst Performance Characteristics (MDAs) Introduction With so much attention being given to environmental issues, the process of sample characterization is challenging today s
More informationarxiv:nucl-ex/ v2 21 Jul 2005
Gamma-spectrometric uranium age-dating using intrinsic efficiency calibration arxiv:nucl-ex/0506029v2 21 Jul 2005 Cong Tam Nguyen and József Zsigrai Institute of Isotopes of the Hungarian Academy of Sciences
More informationEffect of Co-60 Single Escape Peak on Detection of Cs-137 in Analysis of Radionuclide from Research Reactor. Abstract
Organized and hosted by the Canadian Nuclear Society. Vancouver, BC, Canada. 2006 September 10-14 Effect of Co-60 Single Escape Peak on Detection of Cs-137 in Analysis of Radionuclide from Research Reactor
More informationFRAM V5.2. Plutonium and Uranium Isotopic Analysis Software
V5.2 Plutonium and Uranium Isotopic Analysis Software Advanced Isotopic Ratio Analysis Software for HPGe Gamma-Ray Spectra Analyzes Pu, and a wide variety of heterogeneous samples containing Pu, Am, U,
More informationRADEAGLET. Lightweight Handheld Radioisotope Identification Device
RADEAGLET Lightweight Handheld Radioisotope Identification Device Weighing Only 900 grams, the RADEAGLET is the Lightest HH-RIID in the world! The Perfect Instrument for First Responders Who Need to Wear
More informationAUTOMATIC AND INTERACTIVE ANALYSIS SOFTWARE FOR BETA- GAMMA COINCIDENCE SYSTEMS USED IN CTBT MONITORING
ABSTRACT AUTOMATIC AND INTERACTIVE ANALYSIS SOFTWARE FOR BETA- GAMMA COINCIDENCE SYSTEMS USED IN CTBT MONITORING J. Rynes, K.M.F. Biegalski, P. Donohoe, and S. Biegalski Veridian Pacific-Sierra Research
More informationRadioactive Waste Management
International Journal of Research in Engineering and Science (IJRES) ISSN (Online): 2320-9364, ISSN (Print): 2320-9356 Volume 4 Issue 6 ǁ June. 2016 ǁ PP.67-71 Asma Osman Ibrahim Osman 1, Hamid Mohamed
More informationThe European Activation File: EAF-2005 decay data library
UKAEA FUS 516 EURATOM/UKAEA Fusion The European Activation File: EAF-2005 decay data library R.A. Forrest January 2005 UKAEA EURATOM/UKAEA Fusion Association Culham Science Centre Abingdon Oxfordshire
More informationApplication of prompt gamma activation analysis with neutron beams for the detection and analysis of nuclear materials in containers
Application of prompt gamma activation analysis with neutron beams for the detection and analysis of nuclear materials in containers Zsolt Révay Institute of Isotopes, Budapest, Hungary Dept. of Nuclear
More informationIt s better to have a half-life than no life! Radioactive Decay Alpha, Beta, and Gamma Decay
It s better to have a half-life than no life! Radioactive Decay Alpha, Beta, and Gamma Decay What does it mean to be radioactive? Some atoms have nuclei that are unstable. These atoms spontaneously decompose
More informationPete Burgess, Nuvia Limited. Clearance and exemption
Pete Burgess, Nuvia Limited Clearance and exemption The clearance, exclusion and exemption process Most of the UK nuclear industry (and many other organisations) refer to the Clearance and Exemption Working
More informationNeutron activation analysis. Contents. Introduction
Neutron activation analysis Contents Neutron activation analysis... 1 Introduction... 1 Principle of method... 2 Detection of radionuclides... 3 Kinetics of activation... 4 Choosing the appropriate procedure...
More informationARMUG New CAM Developments. Arran Morgan MSc Physicist
New CAM Developments Arran Morgan MSc Physicist Topics Particulate sampling considerations Alpha spectral analysis Concentration calculation Spectrum stabilisation Beta measurement Loose filter Bi detection
More informationHigher -o-o-o- Past Paper questions o-o-o- 3.6 Radiation
Higher -o-o-o- Past Paper questions 2000-2010 -o-o-o- 3.6 Radiation 2000 Q29 Radium (Ra) decays to radon (Rn) by the emission of an alpha particle. Some energy is also released by this decay. The decay
More information1 Introduction. 2 Method. Robert Metzger 1,*, Kenneth Van Riper 2, and George Lasche 3
Uranium, radium and thorium in soils with high-resolution gamma spectroscopy, MCNP-generated efficiencies, and VRF non-linear full-spectrum nuclide shape fitting Robert Metzger 1,*, Kenneth Van Riper 2,
More informationDISTRIBUTION LIST To be filled out by Document Author or person requesting document deletion
DISTRIBUTION LIST To be filled out by Document Author or person requesting document deletion: Once approved, the new or revised document or the notice of deleted document(s) should be distributed to all
More informationExperiment Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado
Experiment 10 1 Introduction Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado Some radioactive isotopes formed billions of years ago have half- lives so long
More informationCharacterising NORM hazards within subsea oil and gas facilities. Daniel Emes SA Radiation
Characterising NORM hazards within subsea oil and gas facilities. Daniel Emes SA Radiation What is in Oil and Gas NORM? Naturally Occurring Radioactive Material (NORM) can be characterized into many forms.
More informationIntroduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48
Introduction to Environmental Measurement Techniques 2016 Radioactivity Dana Pittauer (dpittauer@marum.de) 1of 48 Introduction Radioisotopes are of interest in environmental physics for several reasons:
More informationGamma-Spectrum Generator
1st Advanced Training Course ITCM with NUCLEONICA, Karlsruhe, Germany, 22-24 April, 2009 1 Gamma-Spectrum Generator A.N. Berlizov ITU - Institute for Transuranium Elements Karlsruhe - Germany http://itu.jrc.ec.europa.eu/
More informationIAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES
IAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES V. MAIOROV, A. CIURAPINSKI, W. RAAB and V. JANSTA Safeguards Analytical Laboratory, International Atomic Energy
More informationIdentification of Naturally Occurring Radioactive Material in Sand
Identification of Naturally Occurring Radioactive Material in Sand Michael Pope 2012 NSF/REU Program Physics Department, University of Notre Dame Advisors: Dr. Ed Stech, Dr. Michael Wiescher Abstract Radionuclides
More informationSOURCES of RADIOACTIVITY
Section 9: SOURCES of RADIOACTIVITY This section briefly describes various sources of radioactive nuclei, both naturally occurring and those produced artificially (man-made) in, for example, reactors or
More informationRadioactivity Questions NAT 5
Radioactivity Questions NAT 5 1) Label the particles X, Y and Z from the diagram of the model of the atom below. 2) A Physics teacher demonstrates alpha, beta and gamma radiation during a lesson. She then
More informationNUCL 3000/5030 Laboratory 2 Fall 2013
Lab #2: Passive Gamma Spec Measurements in Decoding Natural Radioactivity in SLC Area Objectives a. Learn basics of gamma spectroscopy b. Learn the equipment in Counting stations #4, #5 and #8 c. Apply
More informationPARAMETERISATION OF FISSION NEUTRON SPECTRA (TRIGA REACTOR) FOR NEUTRON ACTIVATION WITHOUT THE USED OF STANDARD
Parameterisation of Fission Neutron Spectra (TRIGA Reactor) 81 7 PARAMETERISATION OF FISSION NEUTRON SPECTRA (TRIGA REACTOR) FOR NEUTRON ACTIVATION WITHOUT THE USED OF STANDARD Liew Hwi Fen Noorddin Ibrahim
More informationAnalysis of Radioactive Disequilibrium in Natural Decay Chains due to Processing
Analysis of Radioactive Disequilibrium in Natural Decay Chains due to Processing Hans-Jürgen Lange 1, Rainer Dargel 2 1Canberra GmbH, Walter-Flex-Str. 66, 65428 Rüsselsheim Phone: +49 160 5822545, e-mail
More informationUse the graph to show that, after a time of 500 s, about nuclei are decaying every second.
1 The graph below shows the number of radioactive nuclei remaining in a sample of material against time. The radioactive isotope decays to a non-radioactive element. (a) Use the graph to show that, after
More informationApplication of Spectral Summing to Indeterminate Suspect Low-Level Drums at Los Alamos National Laboratory
Application of Spectral Summing to Indeterminate Suspect Low-Level Drums at Los Alamos National Laboratory - 11249 Kathleen M. Gruetzmacher*, John M. Veilleux*, Randy P. Lucero**, James V. Seamans, Jr.**,
More informationWM2018 Conference, March 18-22, 2018, Phoenix, Arizona, USA. PVT and LaBr3(Ce)-based Radon Express Analyzers 18164
PVT and LaBr3(Ce)-based Radon Express Analyzers 864 Vladislav Kondrashov *, Stephen Steranka* and Glenn Paulson** * RadComm Systems Corp. 293 Portland Dr, Oakville, Ontario L6H 5S4, CANADA ** Paulson and
More informationISOCS / LabSOCS. Calibration software for Gamma Spectroscopy
ISOCS / LabSOCS Calibration software for Gamma Spectroscopy Counts Setup Hardware Peak Shaping Parameters Rise Time Flat Top Pole-zero Number of Channels Signal Gain Setting up a detector for measurement
More informationBasic hands-on gamma calibration for low activity environmental levels
Basic hands-on gamma calibration for low activity environmental levels Iolanda Osvath Presented by Mats Eriksson Environment Laboratories Marine Environment Laboratories, Monaco Radiometrics Laboratory
More informationHigher -o-o-o- Past Paper questions o-o-o- 3.6 Radiation
Higher -o-o-o- Past Paper questions 1991-2001 -o-o-o- 3.6 Radiation 1992 Q35 A typical reaction produced in the core of a nuclear reactor can be described by the following equation: (a) State the name
More informationWM2013 Conference, February 24 28, 2013, Phoenix, Arizona USA. Screening and Spectral Summing of LANL Empty Waste Drums 13226
ABSTRACT Screening and Spectral Summing of LANL Empty Waste Drums 13226 Kathleen M. Gruetzmacher (kgruetzmacher@lanl.gov)*, Roland M. Bustos (rbustos@lanl.gov)*, Scott G. Ferran (ferrans@lanl.gov)*, Lucas
More informationThe IAEA-CU world wide open proficiency test on the determination of radionuclides in soil, spinach and water
The IAEA-CU-2007-03 world wide open proficiency test on the determination of radionuclides in soil, spinach and water Laboratory s Final Report Laboratory Code: 146 (CuNo: 13949) Total Pages (with cover):
More informationWM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA
Experimental Comparison between High Purity Germanium and Scintillator Detectors for Determining Burnup, Cooling Time and Decay Heat of Used Nuclear Fuel - 14488 Peter Jansson *, Sophie Grape *, Stephen
More informationNatural Radiation K 40
Natural Radiation There are a few radioisotopes that exist in our environment. Isotopes that were present when the earth was formed and isotopes that are continuously produced by cosmic rays can exist
More informationScience 10. Unit 4:Physics. Block: Name: Book 3: radioactivty
Science 10 Unit 4:Physics Book 3: radioactivty Name: Block: 1 5.1 : Radioactivity & Nuclear Equations Isotopes are versions of an element with the same but Because the number of protons is the same for,
More informationNuclear Physics Part 2A: Radioactive Decays
Nuclear Physics Part 2A: Radioactive Decays Last modified: 23/10/2018 Links What is a Decay? Alpha Decay Definition Q-value Example Not Every Alpha Decay is Possible Beta Decay β rays are electrons Anti-particles
More informationMulti Channel Analyzer (MCA) Analyzing a Gamma spectrum
Multi Channel Analyzer (MCA) Analyzing a Gamma spectrum Objective: Using the MCA to acquire spectrums for different gamma sources and to identify an unknown source from its spectrum, furthermore to investigate
More informationPRACTICAL GAMMA SPECTROSCOPY ASSAY TECHNIQUES FOR LARGE VOLUME LOW-LEVEL WASTE BOXES
PRACTICAL GAMMA SPECTROSCOPY ASSAY TECHNIQUES FOR LARGE VOLUME LOW-LEVEL WASTE BOES Steven C. Myers, Eberline Services, Los Alamos, New Mexico, 87544, smyers@becorp.com Kathleen Gruetzmacher, Los Alamos
More informationA Digital Method for Dead Time Compensation in Nuclear Spectroscopy
A Digital Method for Dead Time Compensation in Nuclear Spectroscopy Keyser, Ronald M., Gedcke, Dale A., Upp, Daniel L., Twomey, Timothy R., and Bingham, Russell D. ORTEC, PerkinElmer Instruments, Inc.
More informationIdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications
fire IdentiFINDER Digital Hand Held Spectrometer & The world s smallest spectrometer and dose rate meter designed for portable applications. safety security identifinder - CH (yellow) CZT and neutron detector
More informationHalf-life data a critical review of TECDOC-619 update
ARTICLE IN PRESS Applied Radiation and Isotopes 60 (2004) 257 262 Half-life data a critical review of TECDOC-619 update M.J. Woods a, *, S.M. Collins b a Ionising Radiation Metrology Consultants Ltd, 152
More informationTechnical note on using JEFF-3.1 and JEFF data to calculate neutron emission from spontaneous fission and (α,n) reactions with FISPIN.
Page 1 of 11 Technical note on using JEFF-3.1 and JEFF-3.1.1 data to calculate neutron emission from spontaneous fission and (α,n) reactions with FISPIN. Nexia Solutions Ltd Dr. Robert W. Mills and Dr.
More informationRadioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado
Experiment 10 1 Introduction Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado Some radioactive isotopes formed billions of years ago have half-lives so long
More informationLAGUNA VERDE NPP DAW DRUMS CLASSIFICATION
ABSTRACT LAGUNA VERDE NPP DAW DRUMS CLASSIFICATION M. Medrano, D. Linares, C. Rodriguez and N. Zarate Gerencia Subsede Sureste National Institute of Nuclear Research Mexico R. Ramirez Radiation Protection
More informationda u g ht er + radiation
RADIOACTIVITY The discovery of radioactivity can be attributed to several scientists. Wilhelm Roentgen discovered X-rays in 1895 and shortly after that Henri Becquerel observed radioactive behavior while
More informationInvestigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the UAL
Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the UAL A. Specification Gamma-spectrometry method is used to identify and determine the activity concentration
More informationAlpha-Energies of different sources with Multi Channel Analyzer
Physical Structure of Matter Radioactivity Alpha-Energies of different sources with Multi Channel Analyzer What you can learn about Decay series Radioactive equilibrium Isotopic properties Decay energy
More informationThe Role of Reference Materials in the Measurement of Terrestrial Radionuclides
Terrestrial Radionuclides in Environment International Conference on Environmental Protection 16-18 May 2012, Veszprém (Hungary) The Role of Reference Materials in the Measurement of Terrestrial Radionuclides
More informationInteractive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools
10th Nuclear Science Training Course with NUCLEONICA, Cesme, Turkey, 8-10 October, 2008 1 Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools A.N. Berlizov ITU - Institute for Transuranium
More informationEuropean Project Metrology for Radioactive Waste Management
European Project Metrology for Radioactive Waste Management Petr Kovar Czech Metrology Institute Okruzni 31 638 00, Brno, Czech republic pkovar@cmi.cz Jiri Suran Czech Metrology Institute Okruzni 31 638
More informationCharacterization of radioactive waste and packages
Characterization of radioactive waste and packages Peter Ivanov Acoustics & Ionising Radiation National Physical Laboratory, UK IAEA WS RER9106/9009/01, Visaginas, Lithuania, 24-28 August 2015 Contents:
More informationPRODUCTS FOR EDUCATION AND TRAINING
PRODUCTS FOR EDUCATION AND TRAINING This section gives detailed information about products to support training in radiation protection, applications of radioactivity and handling radioactive materials.
More informationDepth Distribution of H-3, C-14 and Co-60 in Decommissioning of the Biological Shielding Concrete of KRR-2
Depth Distribution of H-3, C-14 and Co-60 in Decommissioning of the Biological Shielding Concrete of KRR-2 S.B. Hong, H.R. Kim, K.H. Chung, K.H. Chung, J.H. Park Korea Atomic Energy Research Institute
More informationNon-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277
Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277 D. Nakazawa and F. Bronson Canberra Industries Inc., 800 Research Parkway, Meriden, CT, 06450, USA. ABSTRACT
More informationChapter 18 Nuclear Chemistry
Chapter 8 Nuclear Chemistry 8. Discovery of radioactivity 895 Roentgen discovery of radioactivity X-ray X-ray could penetrate other bodies and affect photographic plates led to the development of X-ray
More informationPYCKO SCIENTIFIC LIMITED
PYCKO SCIENTIFIC LIMITED 31 London Road, Grantham, NG31 6EX Telephone 01476 401992 bill@pycko.co.uk www.pycko.co.uk Your Alternative To The Obvious RayMon10 TM Detect, measure, identify and analyse radionuclides
More informationDetermining the Need For External Radiation Monitoring at FUSRAP Projects Using Soil Characterization Data. Todd Davidson
Determining the Need For External Radiation Monitoring at FUSRAP Projects Using Soil Characterization Data Todd Davidson Introduction According to Regulatory Guide 8.34 Monitoring Criteria and Methods
More informationPerformance of the True Coincidence Correction Method in GammaVision. Keyser, Ronald M., Haywood, Susan E., and Upp, Daniel L.
Performance of the True Coincidence Correction Method in GammaVision Keyser, Ronald M., Haywood, Susan E., and Upp, Daniel L. ORTEC, PerkinElmer Instruments, Inc. 801 South Illinois Avenue, Oak Ridge,
More informationLA-UR- Title: Author(s): Submitted to: Approved for public release; distribution is unlimited.
LA-UR- Approved for public release; distribution is unlimited. Title: Author(s): Submitted to: Los Alamos National Laboratory, an affirmative action/equal opportunity employer, is operated by the University
More informationAlpha spectrometry systems. A users perspective. George Ham. 26 th May Date Month Year
Alpha spectrometry systems A users perspective George Ham Date Month Year 26 th May 2005 Centre for Radiation, Chemical and Environmental Hazards Radiation Protection Division formerly the National Radiological
More informationMaterials and waste characterisation Dealing with difficult waste
Materials and waste characterisation Dealing with difficult waste Pete Burgess 24 March 2010 CEWG NICOP A UK success story A simple guide to sentencing waste Much easier to use than MARSSIM NOT tied to
More informationRADIOLOGICAL CHARACTERIZATION Laboratory Procedures
RADIOLOGICAL CHARACTERIZATION Laboratory Procedures LORNA JEAN H. PALAD Health Physics Research Unit Philippine Nuclear Research Institute Commonwealth Avenue, Quezon city Philippines 3-7 December 2007
More informationEXPERIMENTAL DETERMINATION OF THE URANIUM ENRICHMENT RATIO
NUCLER PHYSICS EXPERIMENTL DETERMINTION OF THE URNIUM ENRICHMENT RTIO. LUC Horia Hulubei National Institute for Physics and Nuclear Engineering (IFIN-HH), 407 tomistilor Street, PO Box MG-6, Magurele,
More informationEnvironmental Applications
Environmental Applications Gamma ray Spectrometry Paul Nolan University of Liverpool Gamma ray spectrometry of environmental samples is a standard technique Germanium detector Programs available for spectrum
More informationFrazier L. Bronson CHP Canberra Industries, Inc., Meriden, CT USA ABSTRACT
THE SPECIAL PROPERTIES OF MASSIMETRIC EFFICIENCY CALIBRATIONS AS COMPARED TO THE TRADITIONAL EFFICIENCY CALIBRATION FOR D&D AND ER GAMMA SPECTROSCOPY MEASUREMENTS 10021 Frazier L. Bronson CHP Canberra
More informationFundamentals of Radionuclide Metrology
Fundamentals of Radionuclide Metrology Brian E. Zimmerman, PhD Physical Measurement Laboratory National Institute of Standards and Technology Gaithersburg, MD USA SIM Metrology Workshop Buenos Aires, Argentina
More informationhν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?
Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous? 2. Briefly discuss dead time in a detector. What factors are important
More informationDistinguishing fissions of 232 Th, 237 Np and 238 U with beta-delayed gamma rays
Distinguishing fissions of 232, 237 and 238 with beta-delayed gamma rays A. Iyengar 1, E.B. Norman 1, C. Howard 1, C. Angell 1, A. Kaplan 1, J. J. Ressler 2, P. Chodash 1, E. Swanberg 1, A. Czeszumska
More informationComparison of Several Detector Technologies for Measurement of Special Nuclear Materials i
Comparison of Several Detector Technologies for Measurement of Special Nuclear Materials i A. E. Proctor, K. R. Pohl Constellation Technology Corporation, 7887 Bryan Dairy Road, Largo Fl 33777,U.S.A. Abstract
More informationatomic number and mass number. Go over nuclear symbols, such as He-4 and He. Discuss
Nuclear Decay and Chain Reactions ID: 9522 Time required 45 minutes Topic: Nuclear Identify and write equations for the three forms of nuclear decay. Predict decay products. Perform half-life and decay
More informationAcoustics and Ionising Radiation Formulation and Strategy. 13 November 2008 Alan DuSautoy
Acoustics and Ionising Radiation Formulation and Strategy 13 November 2008 Alan DuSautoy Contents What is the future of Programme Formulation? What is Rolling Formulation? Programme Overview Roadmaps Future
More informationProject Memorandum. N N o. = e (ρx)(µ/ρ) (1)
Project Memorandum To : Jebediah Q. Dingus, Gamma Products Inc. From : Patrick R. LeClair, Material Characterization Associates, Inc. Re : 662 kev Gamma ray shielding Date : January 5, 2010 PH255 S10 LeClair
More informationWM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA
Determination of Components of Fuel Matrix in Water and in Bottom Slimes in the MR Reactor Ponds in NRC Kurchatov Institute 14038 Alexey Stepanov *, Iurii Simirskii *, Ilya Semin *, Anatoly Volkovich *
More informationSensitivity of the IRD whole-body counter for in vivo measurements in the case of accidental intakes
Sensitivity of the IRD whole-body counter for in vivo measurements in the case of accidental intakes B.M. Dantas, E.A. Lucena and A.L.A. Dantas Laboratório de Monitoração In Vivo Divisão de Dosimetria
More informationNuclear Chemistry. Nuclear Terminology
Nuclear Chemistry Up to now, we have been concerned mainly with the electrons in the elements the nucleus has just been a positively charged things that attracts electrons The nucleus may also undergo
More informationSECTION 8 Part I Typical Questions
SECTION 8 Part I Typical Questions 1. For a narrow beam of photons, the relaxation length is that thickness of absorber that will result in a reduction of in the initial beam intensity. 1. 1/10. 2. 1/2.
More informationInaccuracy Determination in Mathematical Model of Labsocs Efficiency Calibration Program
Inaccuracy Determination in Mathematical Model of Labsocs Efficiency Calibration Program M Kuznetsov, T Nikishkin, S Chursin National Research Tomsk Polytechnic University, Tomsk, Russia E-mail: chursinss@tpu.ru
More informationNatural Radiation Map of the Sudan
IOSR Journal of Applied Physics (IOSR-JAP) e-issn: 2278-4861.Volume 9, Issue 4 Ver. III (Jul. Aug. 2017), PP 35-39 www.iosrjournals.org Natural Radiation Map of the Sudan * Magdi Hassan Saad 1, 2 1 - Department
More informationUnderstanding the contribution of naturally occurring radionuclides to the measured radioactivity in AWE Environmental Samples
Understanding the contribution of naturally occurring radionuclides to the measured radioactivity in AWE Environmental Samples Dr Jonathan Burnett ASc Analytical Sciences PhD Supervisors Dr Richard Greenwood
More informationInternational Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories
International Atomic Energy Agency Department of Nuclear Sciences and Applications IAEA Environment Laboratories Vienna International Centre, P.O. Box 100, 1400 Vienna, Austria REFERENCE SHEET CERTIFIED
More informationChem 1A Chapter 5 and 21 Practice Test Grosser ( )
Class: Date: Chem A Chapter 5 and 2 Practice Test Grosser (203-204) Multiple Choice Identify the choice that best completes the statement or answers the question.. The periodic law states that the properties
More informationHigh-energy calibration data for neutron activation analysis
Nuclear Analysis and Radiography Department High-energy calibration data for neutron activation analysis L. Szentmiklósi 1, Zs. Révay 2, B. Maróti 1, D. Párkányi 1, I. Harsányi 1 1 Nuclear Analysis and
More informationNuclear Radiation. Natural Radioactivity. A person working with radioisotopes wears protective clothing and gloves and stands behind a shield.
Nuclear Radiation Natural Radioactivity A person working with radioisotopes wears protective clothing and gloves and stands behind a shield. 1 Radioactive Isotopes A radioactive isotope has an unstable
More informationAUTOMATIC AND INTERACTIVE ANALYSIS SOFTWARE FOR BETA- GAMMA COINCIDENCE SYSTEMS USED IN CTBT MONITORING
ABSTRACT AUTOMATIC AND INTERACTIVE ANALYSIS SOFTWARE FOR BETA- GAMMA COINCIDENCE SYSTEMS USED IN CTBT MONITORING J. Rynes, K.M.F. Biegalski, P. Donohoe, and S. Biegalski Veridian Pacific-Sierra Research
More informationSODIUM PERTECHNETATE ( 99m Tc) INJECTION (FISSION): Revised Final text for addition to The International Pharmacopoeia (January September 2009)
September 2009 RESTRICTED SODIUM PERTECHNETATE ( 99m Tc) INJECTION (FISSION): Revised Final text for addition to The International Pharmacopoeia (January September 2009) [Note from the Secretariat: This
More information29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies AUTOMATED QA/QC CHECK
AUTOMATED QA/QC CHECK FOR β- COINCIDENCE DETECTOR Matthew W. Cooper, James C. Hayes, Tom R. Heimbigner, Charles W. Hubbard, Justin I. McIntyre, Michael D. Ripplinger, and Brian T. Schrom Pacific Northwest
More informationJúlio Takehiro Marumo. Nuclear and Energy Research Institute, IPEN CNEN/SP, Brazil
Júlio Takehiro Marumo Nuclear and Energy Research Institute, IPEN CNEN/SP, Brazil Introduction Brazil State of São Paulo City of São Paulo Reactor IEA-R1 Source: http://www.relevobr.cnpm.embrapa.br Source:
More informationChapter 16 Basic Precautions
Chapter 16 Basic Precautions 16.1 Basic Principles of Radiation Protection The four basic methods used to control radiation exposure are time, distance, shielding, and contamination control. The first
More informationUltratrace analysis of radionuclides by AMS
Ultratrace analysis of radionuclides by AMS Francesca Quinto Contact information: francesca.quinto@kit.edu Karlsruhe Institute of Technology, Please insert a figure in the master transparency. KIT University
More informationPeter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K.
783 SCOPE AND LIMITATIONS XRF ANALYSIS FOR SEMI-QUANTITATIVE Introduction Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K. Historically x-ray fluorescence spectrometry has
More informationA Brief Overview of Radiation and Analytical Water Testing for Radiological Contaminants.
A Brief Overview of Radiation and Analytical Water Testing for Radiological Contaminants. James Henitz Radioanalytical Services NJ Water Monitoring Council: January 24, 2018 Overview of Presentation What
More information7 th International Summer School 2015, JRC Ispra: Operational Issues in Radioactive Waste Management and Nuclear Decommissioning
7 th International Summer School 2015, JRC Ispra: Operational Issues in Radioactive Waste Management and Nuclear Decommissioning Nucleonica: Nuclear Applications for Radioactive Waste Management and Decommissioning
More informationEvaluation of Nondestructive Assay Characterization Methods for Pipe- Over-Pack Containers
Evaluation of Nondestructive Assay Characterization Methods for Pipe- Over-Pack Containers S.B. Stanfield, J.R. Wachter, D.L. Cramer Canberra Instruments Inc. 800 Research Pkwy, Meriden, CT 06450 USA ABSTRACT
More information