Inspection of raw materials and chemicals by using Raman Spectroscopy October, 2013

Similar documents
Verification of Pharmaceutical Raw Materials Using the Spectrum Two N FT-NIR Spectrometer

Quality by Design and Analytical Methods

Pros and cons of using correlation versus multivariate algorithms for material identification via handheld spectroscopy

Swiss Medic Training Sampling

Raw Material Identification with FT-NIR

Rapid Field Testing of Ecstasy Pills Using a 1064-nm Handheld Raman Device

BIOLIGHT STUDIO IN ROUTINE UV/VIS SPECTROSCOPY

Overview of HACCP Principles. OFFICE OF THE TEXAS STATE CHEMIST Texas Feed and Fertilizer Control Service Agriculture Analytical Service

HACCP Concept. Overview of HACCP Principles. HACCP Principles. Preliminary Tasks Development of the HACCP Plan

Test Method Development and Validation as Pertaining to Microtrac Particle Size Measuring Instruments

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FTIR

Snowy Range Instruments

VALIDATION OF ANALYTICAL METHODS. Presented by Dr. A. Suneetha Dept. of Pharm. Analysis Hindu College of Pharmacy

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FT-IR

Introduction to E&Ls 1

IDRaman reader and IDRaman mini: Raster Orbital Scanning (ROS)

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

Application of Raman Spectroscopy for Noninvasive Detection of Target Compounds. Kyung-Min Lee

Overview and comparison of portable spectroscopy techniques: FTIR, NIR and Raman

Putting Near-Infrared Spectroscopy (NIR) in the spotlight. 13. May 2006

Introduction to Fourier Transform Infrared Spectroscopy

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

La RMN quantitative appliquée aux petites molécules

Mira Metrohm Instant Raman Analyzer. Always ready to measure

Spectroscopy tools for PAT applications in the Pharmaceutical Industry

Regulatory and Alternative Analytical Procedures are defined as follows 2 :

Traceable UV-Vis Reference Materials

Application of Raman Spectroscopy for Detection of Aflatoxins and Fumonisins in Ground Maize Samples

New Developments in Raman Spectroscopic Analysis

NaturalFacts. Introducing our team. New product announcements, specials and information from New Roots Herbal. April 2009

transpec Instant Polymer Analyser Webinar starting soon

Agilent Oil Analyzer: customizing analysis methods

COMMITTEE FOR HUMAN MEDICINAL PRODUCTS (CHMP) COMMITTEE FOR VETERINARY MEDICINAL PRODUCTS (CVMP)

SWGDRUG GLOSSARY. Independent science-based organization that has the authority to grant

Substance Characterisation for REACH. Dr Emma Miller Senior Chemist

IntelliCal FAQ Revised 9/27/12

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages

Introduction to Pharmaceutical Chemical Analysis

Simplifying the Process: Automated USP 643 / EP

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

serve the goal of analytical lmethod Its data reveals the quality, reliability and consistency of

Method Transfer across Multiple MicroNIR Spectrometers for Raw Material Identification

Certified Reference Material - Certificate of Analysis Methylone, Primary Standard

Certified Reference Material - Certificate of Analysis

Perseverance. Experimentation. Knowledge.

Probabilistic Approach for Material Verification and Identification in Pharmaceutical Applications

Snowy Range Instruments

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

The Role of a Center of Excellence in Developing PAT Applications

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Portable Raman Spectroscopy for the Study of Polymorphs and Monitoring Polymorphic Transitions

Independence and Dependence in Calibration: A Discussion FDA and EMA Guidelines

Whole Tablet Measurements Using the Frontier Tablet Autosampler System

SIMATIC Ident Industrial Identification Systems

RPR 29 CYCLOTRON RADIOCHEMISTRY LABORATORY

CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR

Introduction to Fourier Transform Infrared Spectroscopy

Confirmation of Coal Quality Using the Agilent ExoScan 4100 Handheld FTIR Spectrometer

Pulsar. Delivering NMR to your benchtop

X-Ray Net Weight Control of Pharmaceutical Products

Benchtop NMR Combined with GC/MS Confirms Identity of Forensic Case Sample

Everyday NMR. Innovation with Integrity. Why infer when you can be sure? NMR

Certified Reference Material - Certificate of Analysis

The Claviature of Gas Analysis

Since 1988 High Force Research has worked with organizations operating in practically all end use sectors requiring chemical synthesis input, and

Laboratory ID. Laboratory Name. Analyst(s) Auditor. Date(s) of Audit. Type of Audit Initial Biennial Special ELCP TNI/NELAP.

Nanoscale IR spectroscopy of organic contaminants

The Elzone II Particle Count and Size Analyzer

Advanced Spectroscopy Laboratory

ALPHA. Innovation with Integrity. The very compact and smart FTIR spectrometer FTIR

ISO Water quality Determination of carbon 14 activity Liquid scintillation counting method

EMPRESA ESPECIALIZADA EN LA DISTRIBUCIÓN DE EQUIPOS DE INVESTIGACIÓN Y CONTROL DE CALIDAD.

HPLC Sample Preparation

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Mixture Analysis Made Easier: Trace Impurity Identification in Photoresist Developer Solutions Using ATR-IR Spectroscopy and SIMPLISMA

Traceability, validation and measurement uncertainty 3 pillars for quality of measurement results. David MILDE

Automated Stability Testing Delivering Rapid Product Development

LABORATORY EXERCISE: USING SPECTROPHOTOMETRY FOR QUALITY CONTROL: NIACIN

Fourier transform infrared spectroscopy (FTIR) is a method used to obtain an infrared

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Introducing New Technology for Liquid Handling Quality Assurance

DAY LABORATORY EXERCISE: SPECTROSCOPY

Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K.

applying a unique combination of disciplines consulting, preclinical, toxicology,

Detection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR

IN THE CIRCUIT COURT OF THE SEVENTEENTH JUDICIAL CIRCUIT IN AND FOR BROWARD COUNTY, FLORIDA. Div.: XXXXXXXX PRC MOTION TO COMPEL ADDITIONAL DISCOVERY

White Paper. Perform Conductivity Measurements In Compliance with USP <645>

Using Calibrated Specular Reflectance Standards for Absolute and Relative Reflectance Measurements

Optical density measurements automatically corrected to a 1-cm pathlength with PathCheck Technology

Whole Tablet Measurements Using the Spectrum One NTS Tablet Autosampler System

Drug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F

Philadelphia University Faculty of Pharmacy Department of Pharmaceutical Sciences First (Fall) semester, 2011/2012. Course code:

Monitoring Emulsion Polymerization by Raman Spectroscopy

ASEAN GUIDELINES FOR VALIDATION OF ANALYTICAL PROCEDURES

Chapter 4: Verification of compendial methods

Robert P. Cogdill, Carl A. Anderson, and James K. Drennen, III

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

The Theory of HPLC. Quantitative and Qualitative HPLC

PC Laboratory Raman Spectroscopy

SYMBIOSIS CENTRE FOR DISTANCE LEARNING (SCDL) Subject: production and operations management

Transcription:

Inspection of raw materials and chemicals by using Raman Spectroscopy October, 2013 Dr Enrique Lozano Sales Director MMS E&A

Industry Trends and Requirements Incremental Regulatory Control for Incoming Material Identification. Regulated markets (pharma, vet, nutr ) PIC/S recommendations on complete traceability of incoming materials GMP is expanding to new products Global Supply Chain Companies are moving toward a more delocalized supply chain Problems associated with supplier quality assurance and transportation Quality Assurance and Cost Reduction Increase analytical capabilities Reduce operational cost Optimize operational efficiencies

Ideal Requirements (5S+C Rules): Sensitive capable of detection of deviations Selective many peaks/bands, minimal outside interference Simple used by spectroscopists and non-specialist operators Stable results must be homogenous through samples, time or environment Specific designed for or customizable to target environment How Much? How Far? How Low? How Many? How Specific? And.Cheap to implement! www.bwtek.com 3

Technology can help Spectroscopy Raman 16/Oct/2013 www.bwtek.com 4

What is Raman Spectroscopy? Molecular spectroscopy that can be used to provide a fingerprint of a compound based on the chemical bonds Based on inelastically scattered light from a molecule Not for trace level detection (~ <1%) Advantages: Can perform analysis directly through transparent containers Samples can be solids, liquid, slurries Applicable for both qualitative and quantitative analysis Little to no sample preparation required Insensitive to aqueous absorption bands Doesn t require large sample volume Highly selective Fast analysis times Reproduced from the website of Dr. David Rankin, Univ. of Edinburgh. Used with permission. www.bwtek.com 5 Copyright @ B&W TEK

www.bwtek.com 6 Copyright @ B&W TEK

What Are companies and Gov. institutions Looking For? Compliance with company production and profitability targets Compliance with regulations Optimization of resources Before introducing handheld Raman in incoming materials at the warehouse Team development and productivity After introducing handheld Raman Simplification of operating procedures Full operations traceability Safety and security image. Source Web www.bwtek.com 7

Raman Spectra Raman Shift Independent of laser output Excitation wavelength is determined by analytical and sample needs (avoid fluorescence interference with longer wavelength) Raman Intensity Depends on laser wavelength The longer the excitation wavelength the lower Raman peak counts (at same power output) www.bwtek.com 8 Copyright @ B&W TEK

Towards 100% Material Inspection Why do we benefits of Identity Testing? But, keep in mind, Raman isn t magic, and it has its limitations!

Benefits of Handheld Raman for ID Reduced material movement directly implement in warehouse, loading dock Easy and simple operations- simple training & improved resource usage Reduce chemical exposure scan through packaging materials & maximize personnel safety Fewer lab delays reduce cycle time on-time production & higher throughput; reduce material quarantine time and stocks Free up laboratory resources increases lab capacity Reduced transcription fewer errors; lower personnel and equipment overhead; control costs Copyright @ B&W TEK

NanoRam Handheld Innovations Only handheld with high resolution touch screen interface Only handheld offering easy data management and reporting Best methodologies for robust analysis Fastest in adding Methods and Libraries Only handheld allowing editing Method Full method development and validation support www.bwtek.com 11 Copyright @ B&W TEK

Issues and Customer Concerns Can Raman help my project? What are the differences between Raman and other spectroscopy techniques like NIR? Should I really perform 100% container ID test? What are my options? Do I need to validate the Raman method? If yes, what are the requirements for method validation? What is next after the Raman ID becomes a routine method? Do I need to know the filing expectations from regulatory agencies, do they apply to me? (JP/EMA/FDA..) Can vendors provide GMP support & related documents? 12

Raman can measure through packaging: broad class Bottles Manufacturer Thickness Vials Bags Amber Glass VWR 3 mm Clear Glass (A) I-Chem 2 mm Clear Glass (B) VWR 2 mm High Density Polyethylene (HDPE) VWR 1 mm Teflon FEP Nalgene 1 mm Polystyrene Uline 1 mm Amber Glass Kimball 1 mm Clear Glass Kimball 1 mm Polypropylene (PP) Low-Density Polyethylene (LDPE) Uline VWR 2 mil 2 mil

Some Raman Applications In Use TODAY ID Identification of raw materials (building up an extensive library of Raman spectra); This is the application for NanoRam Quantitative analysis (iraman products) Quantitative determination of substances in different formulations; Polymorphism (iraman products) Supporting polymorphic screenings (polymorphs have different solubility rates, thereby impacting the effective dosing); Process (PAT) (iraman and MiniRam products) Supporting chemical development process scale-up (as process steps are modified and refined to ascertain whether the desired chemical is being produced or not, and the rate at which it is formed). Identification of unknowns (iraman and nanoram) Forensics, military, police, art conservation Material characterization (iraman products) Define characteristics of materials Unique fingerprint

Portable Raman Instruments Units in each market are designed with key features and characteristics to address specific needs within the market. Some common considerations are: High resolution requires a larger footprint Handheld instruments require fast on-board analysis Portable instruments require highly flexible sampling capabilities www.bwtek.com

The Measurement Challenges- Measure Through Plastic Packaging Implementation advantages of spectroscopic methods No cross-contamination (the material inside the bag) Safe and easy to implement Can be implemented in warehouse, docking area or lab But Challenges exist if using e.g. NIR technique Spectral profiles include packaging absorptions Packaging interferences may reduce the specificity of the method when identify similar materials The library requires assessment or change if the bag changes, i.e., not suitable for multiple suppliers of same materials Packaging could have multiple layers, with different colors or materials 16

1.8 1.6 1.4 NIR Spectra of caffeine (Plastic bag contribution) NIR Spectra of material with plastic bag 1.2 1.8.6 One layer PE bag Two layer PE bag.4 No PE bag (pure sample) 8500 8000 7500 7000 6500 6000 5500 5000 4500 Wavenumber (cm -1 ) Required to evaluate the method specificity in the presence of bag! 17

Raman Spectra of caffeine (Plastic bag 9900 9000 effect) No significant spectral absorption from PE bag Intensity 8100 7200 6300 5400 4500 3600 2700 1800 900 Two layer bag One layer bag No bag 0 2400 2200 2000 1800 1600 1400 1200 1000 800 600 400 200 0 Raman shift [cm -1 ] 18

Raman has greater specificity than NIR 16/Oct/2013 www.bwtek.com 19

Spectroscopic-based Identity Method Sample analysis Operators 1. Access Method 2. Scan sample 3. Identify Material 20

Tools for different verification modes of materials. Identification vs. defined method with p-value (significance level) Investigation for unknown samples: HQI In general, we recommend the use of p-value for ID (identification mode). The HQI (Investigation mode) may be considered an additional tool for validation.

Investigation vs identification on the nanoram Uses statistics, it is used for example to verify that paracetamol is paracetamol, independently of the supplier, container or grades. That variation must be included in the population of the method. Uses HQI to recognize which e.g. supplier of paracetamol is. Here each supplier, container or grade may have a different signature. Requires to setup the libraries.

Validation and/or identification by correlation with a reference, HQI results: from 0% (no relation) to 100% (perfect match)

What HQI means? HQI is the spectral correlation coefficient, i.e. a normalized measure of spectral covariance Nobel prices/country/population vs. amount of chocolate/person. Correlation does not imply causation.

When running IDENTIFICATION and fails, I have some potential hits, what is this? If an identification fails, the system will automatically run an investigation of potential matches.

Spectroscopic-based Identity Test The methods/libraries must be developed and can then be run on routine basis Method development Well-trained analysts Absorbance Units 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Absorbance Units 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 11000 10000 9000 8000 Wavenumber cm-1 7000 6000 5000 11000 10000 9000 8000 7000 6000 5000 1. Measure 3-10 Batches; NanoRam uses 20 spectra 2. Threshold p-value 0.05 based on PCA of 20 spectra 3. Build & Test Method 26

Powerful Spectroscopy!!! Capable to differentiate the smallest changes!!! HQI 100% correlation HQI 99% correlation Reference in library: Calcium Stearate 27

100% correlation with reference on library 99% correlation with reference on library Samples were analyzed on glass vials to reduce container interference. The system is powerful enough to identify the small differences on the structure introduced by the counter ion. 28

Best-of-kind Data reproducibility Unit A Manitol PVC Repetition1 99 97 Repetition2 99 97 L-Alanyl-L-Glutamine Threonine Glutamic acid Repetition3 99 97 Repetition4 99 97 Tryptophan Repetition5 99 97 PVC Manitol Unit B Glutamic acid L-Alanyl-L- Glutamine Tryptophan Threonine Repetition1 99 99 97 97 Repetition2 99 100 98 96 Repetition3 99 100 99 97 Repetition4 99 100 95 97 Repetition5 99 100 99 98 Level of HQI can be increased to 100% adjusting the acquisition parameters 29

Best-of-kind Data reproducibility Unit C Olive Oil (search range 175-2500) Olive Oil (search range 175-1900) Repetition1 99 100 Repetition2 99 100 Repetition3 99 100 Repetition4 99 100 Repetition5 99 100 30

Proximity Matrix Proximity Matrix: Testing of all the materials in Identification Mode using specific methods generated by each of the reference materials Method Materials Material A Material B Material C Method A Method B Method C Method D Method E PASS Fail Fail Fail Fail Fail PASS Fail Fail Fail Fail Fail PASS Fail Fail Provides an overview to illustrate which chemicals may produce: False Positive False Negative good signal bad signal Material D Material E Fail Fail Fail PASS Fail Fail Fail Fail Fail PASS p-value > 0.05 p-value www.bwtek.com 0.001 < 0.05 p-value 10-6 - < 10-3 p-value 10-15 - < 10-6 p-value zero

Common Questions from Customers. 32

Q1: What is the difference between ID and purity tests Identity and Purity are two separate specifications. Purity implies some type of quantitative method; typically HPLC Purity is a test for specific impurities such as low level contaminants/adulterants. An identity test says nothing about purity, strength, or composition. Usually gives binary result : Positive/Negative; Pass/Fail; Yes/No Identity verifies it is similar to what has been used in the past Every proposed method should be validated if it is used for quality decision!

Q2: How long does it take to get a Raman Method in place Bottleneck: Document preparation & internal review Assembling samples Example: Develop an ID method for 10 materials: Training < 1 week Method development 1-2 weeks Specificity & robustness tests < 1 week Documentation (prepare, review & approve) 2-4 weeks The first ID method validation takes 4-6 weeks The next ID validation project takes only 1-2 weeks B&W Tek can provide Support Services

Q3: How do traditional vs. spectroscopic-based methods compare? In traditional methods often have a univariate calibration model Spectroscopic method based on chemometric modeling or statistical calculations Identification/Qualitative Calculate spectral similarity between method and unknown samples Specificity test- interval validation evaluation focus on the model correctness of spectral library Note: Different terminology: Calibration in chemometrics- method/model calibration Calibration in GMP environment - e.g., instrument calibration 35

Summary Raman has proven to be a promising tool to increase operational capabilities and reduce cost. 36

THANK YOU FOR YOUR ATTENTION Dr. Enrique Lozano Sales Director E&A enriquel@bwtek.com www.bwtek.com +447730871095 37

BACK UP SLIDES 38

Raman Related Documents (2) ASTM E1840-96(2007) Standard Guide for Raman Shift Standards for Spectrometer Calibration ASTM E1683-02(2007) Standard Practice for Testing the Performance of Scanning Raman Spectrometers ASTM E2529-06 Standard Guide for Testing the Resolution of a Raman Spectrometer US FDA Advancing Regulatory Science at FDA: A Strategic Plan (August 2011): Section 2. Develop new analytical methods: a) Investigate feasibility and value of using emerging and improved analytical technologies like Nuclear Magnetic Resonance (NMR), mass spectrometry, or near infrared or Raman spectroscopy for evaluating product quality of pharmaceutical agents, and evaluate whether these technologies should replace existing methods;

USP <1225>Validation of Compendial Procedures

Regulatory Standards Compliance 21 CFR Part 11 Electronic Records; Electronic Signatures 21 CFR Part 1040.10 Laser and Laser Systems US Pharmacopeia <1120> Raman Spectroscopy European Pharmacopeia Ch.2.2.48 guidelines for Raman Spectroscopy ASTM 1840-96(2007) Standard Guide for Raman Shift Standards for Wavelength Calibration

Why do Raman ID methods fail? (1) Failure to include lot-to-lot variability use numerous non-consecutive lots realize material potential variability (particle size, moisture, mechanics etc.) Failure to understand the limitation of Raman fluorescence interference low Raman scattering signal (e.g., cellulose, salts, metals) low concentration (e.g., tablet API) Potentially close materials give ambiguous results (pass more than one method) Adjust p-value to narrow acceptance range for material, and limit overlap of methods

Why do Raman ID methods fail? (2) Occasional operational errors Sampling/scanning problem Quality of sample vials (sealed, glass etc.), plastic bags or containers Method specific to particular sampling accessory and/or packaging Limited knowledge or misuse of identity algorithms Performance/sensitivity of identification method (p-value is based on a PCA model on the 20 scans in the method)

Deficiencies of Filed Spectroscopic Methods (1) Absence of instrument description Light source, design, detector, sampling module, software package Minimal description of chemometric techniques Algorithms for pass/fail results Method validation Limited results for method validation Without acceptance criteria (ID thresholds) Detailed results (with predicted values, not just pass or fail) Inappropriate selection of negative control samples (material structurally similar or closely related to the analyte)

Deficiencies of Filed Spectroscopic Methods (2) Inadequate SOPs and plan for change control Spectroscopic method performance verification? Spectroscopic method maintenance plan? Lack of information for library/method update plan SOPs for method/library update?

Raman Method Development Raman bands are distinct and can be easily related to chemical structure -very good for fingerprinting. Conduct a feasibility test: To ensure sufficient sensitivity for compounds to be included in the reference library (very weak scatterers) Minimize fluorescence interference/impurities Laser powers and exposure times confirm that the sample is not being altered Sampling Appropriate sample accessory Collect valid representative samples Understand the sources of variations Glass vial and packaging materials variability Material lot-to-lot variability Supplier variations Need to evaluate the performance on testing numerous lots of material

Raman Method Development Raman bands are distinct and can be easily related to chemical structure -very good for fingerprinting. Raman spectral data collection Measure through containers and plastic bags with appropriate accessory; contribution from the packaging components are usually very minor System automatically determines scan time to give sufficient Raman signal for each sample Collect 20 scans for each method best to use different lots Identification Method The method is based on the 20 scans of the material A multivariate model of the spectra (PCA) with Hotelling st 2 limit determined (95% confidence; p = 0.05) p-value used as Pass/Fail criterion

Validation Process of providing documented evidence that something does what it is intended to do Process, system, method Qualification Inspection, testing and documentation review Is a part of the validation process which verifies module and system performance prior to being placed in routine use Equipment/instrument

Analytical Method Development Prerequisites for analytical method validation-six M s Man Machine Methods qualified calibrated characterized skilled Qualified Material Quality Material qualified Vibrations Milieu robust Humidity Temperature Irradiation suitable Time Management Supplies documented Analysts support Quality of the analytical method

Analytical Instrument Qualification USP <1058> Analytical Instrument Qualification

DQ/IQ/OQ and PQ Documents for NanoRam

Calibration Validation: part of the PQ Self check: by performing calibration validation using ASTM 1840 ref material: Polystyrene 53

Method Development- Special Considerations for Raman Technique Fluorescence interference/presence of impurities Baseline shifts and background signal Laser power Confirm that the sample is not being altered. We keep information on laser power in the method. Sample-position sensitivity Use of appropriate sampling accessory.

NanoRam: Operation Preset Managerial level access to set Operation Preset ADMIN can also create user accounts: Developer and Operator level users Create calibration files Copyright www.bwtek.com @ B&W TEK 55

Selecting libraries to use in Investigation The libraries against which the search and match is performed can be modified. Multiple libraries can be selected. The Methods also can be searched to establish a match of materials using an HQI against www.bwtek.com 56 Copyright @ B&W TEK every Method.

Operator NanoRam User Levels Developer User Type Administrator Device Manager User Type Symbol 57 User Privileges Select Method Perform Material Identification Select Operation Preset Data Transfer All above, plus: Create /Edit Method Create/Modify Operation Preset Create/Modify Data Library All above, plus: Manage User Accounts Create calibration files Set system clock Set password expiration Create calibration file Reset ADMIN password Copyright @ B&W TEK

ADMIN user can create other accounts Three levels of users: Operator Developer Administrator User accounts www.bwtek.com 58 Copyright @ B&W TEK

Analytical Method Validation Do we need to perform method validation of spectroscopic-based techniques?