WEATHER STATION FIELD GUIDE

Similar documents
PRODUCT DATA. Sound Intensity Calibrator Type 3541-A. Uses and Features

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA MODELS: 450S AND 450ES

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 300

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 400

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

Assembly and Operation Manual. April 2016

Quick Start Guide. The ieq45 GoTo German Equatorial Mount # 8000C

HT600 Dat e Code: 2 - HT MW Purchase Date: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE. All Rights Reserved

INSTALLATION INSTRUCTIONS FRONT PLOW MOUNT KIT Part Number: Application: Polaris Sportsman 400, 500, 800

Product Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541

INSTALLATION INSTRUCTIONS PLOW MOUNT KIT Part Number: Application: Honda Foreman 500

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL

HEAVY DUTY SWING-OUT VALVE

INSTALLATION INSTRUCTIONS ATV PLOW ACCESSORY Plow Mounting Kit:Warn PN Application:2002 and newer+ Suzuki Eiger 400

Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR

HEAVY DUTY SWING-OUT VALVE

Conversion Kit for: 7620 and 7820 Swing-Out Valves ft-lbs ft-lbs 8835/ ft-lbs

Elcometer 116C. Sling Hygrometer. Operating Instructions

/2" Heavy Duty Swing-Out

WARNING. INJURY HAZARD Failure to observe these instructions could lead to severe injury or death.

RECON. How to Setup the Telescope to Observe. This guide will show you how to setup your telescope for observing. Written By: Brittany McCrigler

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

PoleMaster User Manual (Northern Hemisphere)

INSTALLATION INSTRUCTIONS ProVantage Plow Pulley Part Number: 84526

Experiment C-10 Titration of a Strong Acid and a Strong Base

WeatherHawk Weather Station Protocol

F AX:

Doc No. KF08-002D. Portable Ultrasonic Flowmeter UFP-20. Installation & Operation Manual

WeatherHub2 Quick Start Guide

Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0

Non-Acoustical Inputs

x Builders Level Service Manual

22X Builder s Level Model No Instruction Manual

Electricity. Measuring the force on current-carrying conductors in a homogeneous magnetic field. LEYBOLD Physics Leaflets P

Experiment C-15 Distillation - part 1

FOR POLARIS ATV s P/N ASSEMBLY / OWNERS MANUAL

Important Instructions

VIBRATION METER. Instruction Manual.

PUSH TUBE STANDARD DUTY

FIELD SPECTROMETER QUICK-START GUIDE FOR FIELD DATA COLLECTION (LAST UPDATED 23MAR2011)

Training Guide. Coastal Environmental Systems, Inc.

FOREMAN ASSEMBLY / OWNER S MANUAL

Rain Collector (# 7852 & 7852M)

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

Pneumatic Tools / Machinery. Components and Spare Parts see pages 286 to 291

Sensor Accessories. Rotary Motion Accessory Pack. Pendulum Rod with two masses, Angular Momentum disc set and Linear Rack with mini c-clamp

Instruction Manual. Omegon EQ-500 Equatorial Mount English version Rev A

FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

22X Builder s Transit Level Model No Instruction Manual

OASIS WIRELESS WEATHER STATION

FOR CAN-AM ATV s P/N ASSEMBLY / OWNERS MANUAL

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

WATTS MICROPTIC ALIDADE OPERATING INSTRUCTIONS 20-7

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

473 Dew Point Hygrometer

Dynamics Track. Magnetic Force Impulse and Momentum

Appendix 2: Disassembling and Assembling the Telescopes and the Celestron Equatorial Mounts

Directions for use

Must Read Before Installation TadPoleTM Safety and Warnings

iweathar EDGE V Installation Guide Copyright 2012 iweathar. All rights reserved.

WARNING. INJURY HAZARD Failure to observe these instructions could lead to severe injury or death.

Quick Reference. Daily Cleaning Procedures Pages 3-8 Stopping Conditions & Recovery Steps Pages 9-20

SL191. Structured Pattern Generator SL191-WHIIC SL IC. Designed for applications requiring structured illumination

Automatic Level NP-732

WEATHER MULTI-SENSOR. Vaisala Weather Transmitter WXT510. Change the Way You Measure Weather

HD2016. [ GB ] Weighing rain gauge. Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION

THE LOSMANDY G-11 MOUNT

Dual Red or Green Electronic Dot Sight Instruction Manual

PLOW MOUNT KIT FOR YAMAHA VIKING P/N ASSEMBLY / OWNERS MANUAL. Application PLOW PUSH FRAME NO or

INSTRUCTION MANUAL. EQ8 Mount V2. Copyright Sky-Watcher

Edition 3 September Air Angle Wrench and Nut Runner. QA6 and QA8 Series. Parts Information. Save These Instructions

PHOENIX CONTACT - 04/2016. Features

personal weather station

product manual H-3220A Benkelman Beam

BERMAD Irrigation. BIC2000 Weather Station SYSTEM GUIDE VERSIONS : BIC ; PC 4.90

WEATHERPAK TRx Training Guide

Innovative Sustainable Technology

WEATHERPAK MTR Training Guide

WS-9018U Wireless Weather Station. Instruction Manual

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

Online Assembly Guide : 4.5 inch Reflector Telescope

HUSTLER 7' & 8' POOL TABLE ASSEM BLY I NSTRUCTI ONS

Electron Microscopy Sciences INSTRUCTION MANUAL. Stereo Microscopes Non-illuminated Stands

Optional Connector Optional power compatibility XXX. IC i3 C2 C3 C5. M12* (i3: 5-pin male; IC: 4-pin male) 3.0 mw/cm2 245,000 Lux (white)

O P E R A T I N G M A N U A L

Lever-type Dial Test Indicators

2.4M SERIES 1241 ANTENNA

Lever-type Dial Test Indicators

ATV WP2 FRONT MOUNT PUSH TUBE

IF YOU NEED ANY FURTHER HELP WITH YOUR GALILEO TELESCOPE PLEASE CALL MON-FRI 9AM - 5PM E.S.COM

Red and Green Dot Sight FF26002 USER MANUAL

AccuAligning TM Polar Scope for SmartEQ TM Portable German Equatorial GOTO Mount. Installation and User Manual. Product #3130

Professional Wind Station

E8EB-N0C2B E8EB-N0B2B

GY 301: Geomorphology Lab 5: Total Station Mapping Project

THE VIPER ATV PLOW SYSTEM

EXPERIMENTAL INVESTIGATION OF PRECESSION AND NUTATION OF A GYROSCOPE AND DETERMINATION OF MOMENT OF INERTIA

Integrated Sensor Suite Installation Manual. Model #6357. Distributed by MicroDAQ.com, Ltd. (603)

Transcription:

WEATHER STATION FIELD GUIDE

2013 Copyright Brüel & Kjær. All rights reserved

OVERVIEW This guide illustrates the setup of Weather Station Kits MM-0316-A and MM-0256-A and general accessories for adding weather data to environmental noise measurements. 1) Check case contents and assess needed accessories for appropriate mounting method. (Included and Optional Accessories, p. 2) 2) Mount weather station. (Mounting, p. 3) 3) Connect to hand-held analyzer. (Connection, p. 7) 4) Hand-held analyzer setup and system operation check. (System Setup and Check, p. 8) 5) Post-processing using Measurement Partner Suite BZ-5503. (Post-processing, p. 10) Weather Station Kit MM-0316-A (left) measures wind speed and direction and MM-0256-A (right) adds ambient temperature, ambient humidity, ambient pressure and rainfall measurement. Weather conditions affect the propagation of sound. Particularly wind speed and direction must be taken into account when measuring noise outdoors. Most standards for the measurement of environmental noise specify allowed ranges of wind speed and direction. Brüel & Kjær s Weather Station Kits (based on Vaisala WINDCAP Ultrasonic Wind Sensor WMT52 and Weather Transmitter WTX520, respectively) capture wind speed and direction data simultaneously with noise parameters directly on the analyzer. Post-processing is provided by Measurement Partner Suite BZ-5503. Check applicable standards for specific setup height, distance, etc. NOTE: Safety related issues such as the height /stability of the weather station and analyzer mounting are not addressed in this guide. 1

INCLUDED AND OPTIONAL ACCESSORIES Included with the Weather Station Kit 1) KE-4334 Carrying Case 1 2) BR-1779 Field Guide and Weather Station User s Guide (under field guide) 2 3) MM-0256-002 6-Parameter Weather Station and Mounting Kit or MM-0316-002 2-Parameter Weather Station and Mounting Kit (insert) 3 4) UA-1707-A Tripod Adaptor 5) ZH-0698 Weather Station USB Adaptor 4 3 6) DB-4364 Pole Adaptor (for 1 pole or speaker tripod) 7) QX-1171 2.5 mm Hex Wrench 5 6 8) QX-0016 Flat-head Screwdriver 9) AO-0657 USB Adaptor Cable 10 7 8 9 10) AO-0659 Cable M12 8-pin (F) to Lemo 1-B 8-pin (M), 10 m (33.3 ft) Optional Accessories (not Included) AO-0751-D-200 Extension Cable (20 m) UA-0801 Tripod (lightweight, for use with tripod adaptor) UA-0587 Tripod (heavy duty, for use with tripod adaptor) Speaker tripods (not supplied by Brüel & Kjær), which can be used with the pole adaptor NOTE: Speaker tripod suppliers may be able to provide other useful accessories for mounting the weather station or analyzer. 2

MOUNTING Mounting Kit The mounting kit can be used to save time and wear when, for example, you will be mounting and dismounting the weather station repeatedly at a particular location. If you will be mounting the weather station on the tripod adaptor or pole adaptor for a long period, the mounting kit is not necessary. Except where specifically stated, all mounting instructions use the mounting kit. 1 3 2 4 Attach the Mounting Kit to the Tripod Adaptor, Pole Adaptor or Pole 1) Use the 2.5 mm hex wrench to loosen the retaining screw on the sleeve of the mounting kit. 2) Unless you are placing the adaptor on a 3/4 pole, remove the 3/4 pole adaptor sleeve from the mounting kit. NOTE: If using the adaptor, ensure that the gap in the adaptor does not line up with the retaining screw. 3) Place the mounting kit on the end of the adaptor or pole. 4) Tighten the retaining screw, slightly. You may loosen the screw again soon for northerly orientation. NOTE: Do not overtighten the retaining screw, particularly on the tripod adaptor, you may damage the adaptor. 3

1 2 Mounting the Weather Station on a Tripod 1) Remove the tripod s head, if present. 2) Unscrew and remove the tripod adaptor base and screw it onto the tripod. 3) Thread Cable AO-0659 through the body of the adaptor and mounting kit Screw the adaptor body back on the adaptor base. NOTE: Ensure that the cable runs through the slot at the base of the adaptor. 4) Connect the cable to the weather station. 5) Place the flanges on the mounting kit into the slots in the weather station and turn clockwise until it snaps into place. 3 4 Align to North Align the weather station using a compass and the NORTH arrow on the bottom of the weather station by: a) turning the tripod, or b) loosening the mounting kit retaining screw (2.5 mm hex wrench), turning the mounting kit then retightening the retaining screw. 5 4

1 3 2 Mounting the Weather Station on a Speaker Tripod Using the Pole Adaptor 1) Remove the endcap from the tripod stem. 2) Thread Cable AO-0659 through the body of the adaptor and mounting kit, then slide the adaptor onto the tripod stem. NOTE: Ensure that the cable runs through the slot at the base of the adaptor. 3) Tighten the pole adaptor retaining screw using the screwdriver. 4) Connect the cable to the weather station. 5) Place the flanges on the mounting kit into the slots in the weather station and turn clockwise until it snaps into place. Align to North Align the weather station using a compass and the NORTH arrow on the bottom of the weather station by: a) turning the tripod, or b) loosening the mounting kit retaining screw (2.5 mm hex wrench), turning the mounting kit then retightening the retaining screw. 4 5 5

1a 2 1b Mounting the Weather Station on a Pole 1) Place the pole adaptor or mounting kit (appropriate to pole diameter) onto the pole: If you are using the pole adaptor: thread Cable AO-0659 through the body of the adaptor and mounting kit (1a) or thread the cable through the pole, adaptor and mounting kit (1b). If you are only using the mounting kit, you must thread Cable AO-0659 through the pole and mounting kit (1b). NOTE: Ensure that the cable runs through the slot at the base of the adaptor. 2) Tighten the pole adaptor or mounting kit retaining screw using the screwdriver. 3) Connect the cable to the weather station. 4) Place the flanges on the mounting kit into the slots in the weather station and turn clockwise until it snaps into place. Align to North Align the weather station using a compass and the NORTH arrow on the bottom of the weather station by: a) turning the tripod, or b) loosening the mounting kit retaining screw (2.5 mm hex wrench), turning the mounting kit then retightening the retaining screw. 3 4 6

CONNECTING USB ADAPTOR ZH-0698 1 2 Using a Tripod 1) Mount the hand-held analyzer on its tripod. 2) Strap the USB adaptor to the tripod wth the Velcro band. 3) Connect the cable from the weather station to the USB adaptor. 4) Connect the USB adaptor to the analyzer s USB standard A socket for G4 analyzers (shown) or USB mini B socket for G1 3 (Adaptor Cable AO-0657). The weather station will function automatically while connected to the analyzer. To check system operation and additional setup information see the next section: System Setup and Check. 3 Weather Protection 4 USB Adaptor ZH-0698 and the hand-held analyzer can be protected inside All-weather Case Type 3535-A. Please refer to Product Data BP 2251. NOTE: For more information on analyzer storage and mounting, see User Manual for Hand-held Analyzer Types 2250 and 2270 (BE 1713) or User Manual for 2250 Light (BE 1766). 7

SYSTEM SETUP AND CHECK System Setup The weather station communicates automatically with the analyzer without any operator setup of the weather station. When the weather station connects, this message will display for about 2 seconds. When the weather station disconnects, this message will display for about 2 seconds. For information concerning weather parameter settings on the analyzer, see User Manual for Hand-held Analyzer Types 2250 and 2270 (BE 1713) or User Manual for 2250 Light (BE 1766). NOTE: Wind Speed and Wind Direction data are updated at a 1 s interval and will normally update on screen every few seconds (even though they are exponentially averaged with an averaging time of 5 s). 8

System Check To confirm that the system is working, open the template you will use (Enhanced Logging template is shown), tap the Broadband tab then: Tap a parameter. Tap More. Tap Weather. Tap Wind Speed. Wind speed values will be displayed on screen circa 8 seconds after the weather station is connected. If there is a connection problem, dashes will be displayed on screen. NOTE: MM-0256-A: Data are shown for all weather parameters. MM-0316: Data are shown only for wind parameters. 9

POST-PROCESSING Measurement Partner Suite BZ-5503 Back in the office download your noise and wind data to Measurement Partner Suite for post-processing. All weather parameters as measured on the instrument can be seen in Measurement Partner Suite, and you can even display wind speed and direction on the same graph as your noise profile. If wind data has been logged, use the Report and marker wizard in Logging Module BZ-5503-A-012 to select the time intervals in the logging profile that you need to make an assessment of noise. Otherwise make your assessment based on the total values for wind speed and direction. For more information, please refer to the Measurement Partner Suite BZ-5503 Online Help and Product Data (BP 2430). 10

SPECIFICATIONS Setup and Specifications Please refer to the analyzer user manuals and included weather station user s guide. Dimensions Case 345 x 265 x 165 mm Configuration: Type 2250, weather station, speaker tripod and pole adaptor. 11

Configuration: Type 2250, weather station, Outdoor Microphone Type 4952, Configuration: Type 2250, weather station,,all-weather Case Type 3535-A tripod and tripod adaptor speaker tripod and pole adaptor 12

HEADQUARTERS: Brüel & Kjær Sound & Vibration Measurement A/S DK-2850 Nærum Denmark Telephone: +45 7741 2000 Fax: +45 4580 1405 www.bksv.com info@bksv.com Local representatives and service organisations worldwide BR 1779 12 ËBR-1779---}Î