Analogue Meters CQ2x07 series

Similar documents
Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

Type Function Output config. Auxiliary Case Page

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Non-Contact Safety Systems CMS

Operating Instructions for Digital Manometer. Model: MAN-SD

TECHNICAL INFORMATION

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

Thermal-Magnetic Circuit Breaker 2210-T2...

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DC/DC regulator Input V Output up to 16 A

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

Redline Unibis : the solution Circuit protection

TeSys circuit-breakers

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

American Zettler AZ742 RELAY Datasheet

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

5730A High Performance Multifunction Calibrator. Extended specifications

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

S R O T C U D IN & MYRRA

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

ct m ive p 5/EC Thermal cut-outs

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

THREE PHASE CAPACITOR For WIND TURBINES

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2...

Film Capacitors. EMI suppression capacitors. Date: June 2018

Impedance relay and protection assemblies

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure Measurement Single-range transmitters for general applications

GENERATOR INTERCONNECTION APPLICATION

792A AC/DC Transfer Standard

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW

LED light engine / OLED LED compact. Uready2apply DLA G1 SNC China domestic

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS

Thermal-Magnetic Circuit Breaker 2210-S2..

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Thermal-Magnetic Circuit Breaker 2210-S2..

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

Time - timing relays 1 Industrial relays, solid state output, width 22.5 mm

Thermal-Magnetic Circuit Breaker 2210-S2..

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Issued August DATA SHEET. 3VT3 MCCB up to 630 A

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

Work, Energy and Power

Imformation of C091D series

Masterpact. Installation recommendations

792A AC/DC Transfer Standard

VTU E-LEARNING NOTES ON:

PHOENIX CONTACT - 04/2016. Features

RoHS. Versatile. X g. X 2 e

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES

Display counter electromechanical

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

VK2 volume flow controller Overview

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

Installation Contactors ISU-xxx ISM-xxx

Pressure Display Controller

Linear measuring technology

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Lecture 11 - AC Power

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS

Work, Energy and Power

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

Power Resistor for Mounting onto a Heatsink Thick Film Technology

CDS. high density spring connection

Lecture 05 Power in AC circuit

LED light engine / OLED LED compact. Uengine DLE G2 integrated ADV

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

Features. Type List. Ordering Information TPDT H

Power and Energy Measurement

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

BETA Protecting Miniature Circuit Breakers

Power Resistors, for Mounting onto a Heatsink Thick Film Technology

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Lamp and Control Panel (Lamp Panel)

ED 701 General Industry Pressure Transmitter

2-2. Bulletin 140M Motor Protection Circuit Breakers. Product Overview. Table of Contents. Standards Compliance. Certifications. General Information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Size A DIN EN

W250: Compact photoelectric switch series for a broad range of applications

Sinusoidal Steady State Power Calculations

Transcription:

Analogue Meters CQ2x07 series Analogue Power Meters Active, reactive, apparent power meters and Power factor meters with exchangeable scales EQ0207/2207/0107/2107 & YQ0207/2207/0107/2107 o Measurement of Active or reactive or apparent power (EQ) or power factor (YQ) o Single or three phase, 3 or 4 wire, balanced or unbalanced connection o Standard 96 X 96 DIN case (EQx207, YQx207) or standard 144 X 144 DIN case (EQx107, YQx107) o Protective cover for terminal o USB service port (option)

PROPERTIES o Measurement of Active or reactive or apparent power (EQ) or power factor (YQ) o Single or three phase, 3 or 4 wire, balanced or unbalanced connection o Standard 96 X 96 DIN case (EQx207, YQx207) or standard 144 X 144 DIN case (EQx107, YQx207) o Exchangeable scale o Frequency range from 16 Hz to 400 Hz o Automatic range of nominal current (max. 12.5 A) o Protective cover for terminal o USB service port (option) DESCRIPTION The meter is intended for measuring power and power factor in single phase or three phase electrical power network. The meter measure according to the principle of fast sampling of voltage and current signals. A built in microprocessor calculates power and power factor from the measured signals. USE The meter is intended for measuring power of single phase or three phase electric distribution system. COMPLIANCE WITH STANDARDS: Standard EN 61010 1 60529 60051 1 61326 * Par al compliance SHIP VERSION Description Safety requirements for electrical equipment for measurement, control and laboratory use Degrees of protection provided by enclosures (IP code) Direct acting indicating analogue electrical measuring instruments and their accessories Electrical equipment for measurement, control and laboratory use EMC requirements Special "ship version" are delivered for building into ships. These are mechanically resistive instruments which correspond to the rules of construction of seagoing ships (Bureau Veritas certified). DESCRIPTION OF PROPERTIES MEASURANDS Measurements of momentary active, reactive, apparent power and power factor. ANALOGUE POINTER Two types of pointers are available EQ0X07 and YQ0X07 have 90 analogue pointer. EQ2X07 and YQ0X07 have 240 analogue pointer. END SCALE VALUE The end scale value is determined as follows: The power to be measured by the instrument can be calculated by using one of the formula below: Power system Active Reactive Apparent single phase U I cosϕ U I sinϕ U I 3 phase 3 wire 3U I cosϕ 3U I sinϕ 3U I 3 phase 4 wire 3 U I cosϕ 3 U I sinϕ 3 U I Power factor is calculated from active and apparent power U in equations is the phase voltage in single phase system, line voltage in three phase 3 wire system, and phase voltage in three phase 4 wire systems. According to the calculated value, one of the following standard end scale values and their decade are chosen: 1 1.2 1.5 2 2.5 3 4 5 6 7.5 8 Accordingly, it has been considered that the scale factor, i.e. the relation between the end scale value and the apparent power (cosϕ or sinϕ is 1) must be within limits of 0.6... 1.2. SUPPLY Power supply connection of the meter is adaptive. Meter can be supplied internally from voltage measuring inputs or externally via separate connector. USB SERVICE COMMUNICATION (OPTION) Meter can be equipped with service port with mini USB connector that can be used for setting. This port is not galvanic separated and for this reason, BEFORE USE INPUT VOLTAGE AND POWER SUPPLY ON THE METER MUST BE DISCONNECTED. Communication via service port is time limited. TECHNICAL DATA EU DIRECTIVES Directive 2014/35/EU on low voltage. Directive 2014/30EU on electromagnetic compatibility. Directive on RoHS 2011/65/EU. SAFETY Protection: protection class II 600 V rms, installation category II 300 V rms, installation category III pollution degree 2 in compliance with EN 61010 1 Enclosure material: PC/ABS incombustibility self extinguishability, complying with UL 94 V 0 Enclosure protection: IP 52 (IP 00 for terminals) in compliance with EN 60529 Cutting for installation: 92 +0,8 mm 138 +0,1 mm Converter mass: max. 600 g 2 EQxx07C Active, reactive, apparent power meters & YQxx07C Power factor meters

AMBIENT CONDITIONS Temperature range of operation: Storage temperature range: Average annual humidity: 10 to +60 C 40 to +70 C 75% r.h. INPUTS Input signals Current Voltage Nominal frequency range 50, 60 Hz Measuring frequency range 16 400 Hz Nominal value (In, Un) 1 / 5 A 75, 120, 250, 500 V L N Maximal value 12.5 A 600 V L N Consumption < 0.1 VA < 0.1 VA SUPPLY Power supply Nominal voltage AC Nominal frequency Nominal voltage DC Consumption AC 57.7 / 63.5 / 100 /110 / 230 / 400 V 40 65 Hz < 1.5 VA REFERENCE CONDITIONS Ambient temperature: 10 23 55 C Voltage input: +/ 20% Un Current input 0 100 % In Active/reactive power factor: cos =1 / sin =1 Waveform: Sinus CONNECTION ACCURACY Measurand Accuracy Active or reactive or apparent power 1.5 Voltage inputs can be connected either directly to low voltage network or via a high voltage transformer to high voltage network. Current inputs shall be connected to network via a corresponding current transformer. System/ connection with Terminal assignment 1b single wire, balanced load 3b three wire, balanced load EQxx07C Active, reactive, apparent power meters & YQxx07C Power factor meters 3

3u thee wire, unbalanced load 4b four wire, balanced load 4u four wire, unbalanced load CONNECTION TERMINALS AND MARKING Inputs / Quantities Terminals IL1 CT1 AC current IL2 CT2 IL3 CT3 Measuring inputs: UL1 2 AC voltage UL2 5 UL3 8 N 11 Auxiliary power supply: AC L 13 AC N 14 COMMUNICATION TERMINALS Communication Terminals USB service port USB Min B type TERMINALS Connection Max. conductor cross sections Voltage inputs (4) 2.5 mm 2 ; one conductor Current inputs (3) Ø 6 mm; one conductor with insulation Power supply (2) 2.5 mm 2 ; one conductor 4 EQxx07C Active, reactive, apparent power meters & YQxx07C Power factor meters

DIMENSIONAL DRAWING DATA FOR ORDERING The following data shall be stated: Type of a meter Connection VT and CT ratio Voltage range Type of power supply Scale data Special option ORDERING When ordering the meter, all required specifications shall be stated in compliance with the ordering code. EXAMPLE OF ORDERING: EQ0207 meter will measure active power with 90 pointer (standard scale). It is connected directly to three phase 4 wire system with phase voltage 230 V L N, nominal current 5A and frequency range 50Hz. Device is powered from measuring circuit. It has no communication build in. Cutout for panel is 96 x 96 and standard finish. Ordering code: EQ0207 S L 4U 230V 5A S X T N A A S S S Y EQxx07C Active, reactive, apparent power meters & YQxx07C Power factor meters 5

EQXX07 GENERAL ORDERING CODE Type Class Zero Position Connection Nominal Voltage Nominal Current Frequency Range Auxiliary Supply Current connection Service Comm. Finish EQx207 x x x x x x x x x x x x x x x I I I I I I I I I I I I I I I Y Yes * I I I I I I I I I I I I I I I N No I I I I I I I I I I I I I I S Black * I I I I I I I I I I I I I I W White Not available if Finish is P, G, R or V I I I I I I I I I I I I I S Single Scale * I I I I I I I I I I I I I D Double Scale I I I I I I I I I I I I S Standard with Scale * I I I I I I I I I I I I N Bianco Dial I I I I I I I I I I I I X No Dial I I I I I I I I I I I A Clear Glass * I I I I I I I I I I I B Clear Glass + Red Adj. Index I I I I I I I I I I I L Anti Glare Glass I I I I I I I I I I I D Anti Glare + Red Adj. Index I I I I I I I I I I A Standard * I I I I I I I I I I H HVE (Tropical Seal) I I I I I I I I I I M Inc. Mech. Resistance I I I I I I I I I I S Ship Ver. I I I I I I I I I I P IP54 I I I I I I I I I I G HVE + IP54 I I I I I I I I I I R Ship Ver. + IP54 I I I I I I I I I I T Ship Ver. + HVE I I I I I I I I I I V Ship Ver. + HVE+IP54 I I I I I I I I I N Without * I I I I I I I I I M Mini USB I I I I I I I I T Through Hole Transformer * I I I I I I I I C Screw Terminal Connector I I I I I I I X Internal L1 N I I I I I I I Y Internal L1 L2 I I I I I I I A E 57,7 V I I I I I I I B E 63,5 V I I I I I I I C E 100 V I I I I I I I D E 110 V I I I I I I I E E 230 V I I I I I I I F E 400 V I I I I I I I J E 440 V I I I I I I S 50 Hz * I I I I I I T 60 Hz I I I I I I R 45 65 Hz I I I I I 1A 1 A I I I I I 5A 5 A I I I I 57P7 57,7 V L N \ 100L 100 V L L \ 57V7 57,7/100 V \ I I I I 63P5 63,5 V L N I 110L 110 V L L I 63V5 63,5/110 V I I I I I 66P4 66,4 V L N I 115L 115 V L L I 66V4 66,4/115 V I I I I I 69P3 69,3 V L N I 120L 120 V L L I 69V4 69,3/120 V I I I I I 100P 100 V L N I 220L 220 V L L I 110V 110/190 V I I I I I 115P 115 V L N I 225L 225 V L L I 120V 120/208 V I I I I I 127P 127 V L N 1B 230L 230 V L L I 127V 127/220 V I I I I I 130P 130 V L N Connect. 380L 380 V L L 3B and 3U 130V 130/225 V 4B and 4U I I I I 132P 132 V L N I 400L 400 V L L Connect. 132V 132/230 V Connect. I I I I 220P 220 V L N I 415L 415 V L L I 220V 220/380 V I I I I I 230P 230 V L N I 440L 440 V L L I 230V 230/400 V I I I I I 240P 240 V L N I 450L 450 V L L I 240V 240/415 V I I I I I 250P 250 V L N I 460L 460 V L L I 254V 254/440 V I I I I I 254P 254 V L N / 470L 470 V L L I 277V 277/480 V I I I I I 480L 480 V L L I 288V 288/500 V / I I I I 500L 500 V L L I I I I 1B Single phase I I I 3B 3 phase 3 wire balanced I I I 3U 3 phase 3 wire unbalanced I I I 4B 3 phase 4 wire balanced I I I 4U 3 phase 4 wire unbalanced I I L 0 / 1 * I I C 1 / 0 / 1 I I F 0.1 / 0 / 1 I I A 0.x / 0 / 1 I S 1.5 * I H 1.0 EQ0107 Power meter 144 mm 90 EQ0207 Power meter 96 mm 90 EQ2107 Power meter 144 mm 270 EQ2207 Power meter 96 mm 270 * Default ordering value Window Dial Index Type Zero Adjuster Colour Protection Cover 6 EQxx07C Active, reactive, apparent power meters & YQxx07C Power factor meters

EQXX07 GENERAL ORDERING CODE CONFIGURATION SETTINGS VT ratio CT ratio Measured Parameter Index Scale Range Index xxx V / xxx V xxx A / x A x 0 xxx W I I I 0...xxx W (kw, MW, GW) I I I 0...xxx var (kvar, Mvar, Gvar) I I I 0...xxx VA (kva, MVA, GVA) I I I xxx...0...xxx W (kw, MW, GW) xxx...0...xxx var (kvar, Mvar, Gvar) I I I xxx...0...xxx VA (kva, MVA, GVA) I I P Total Active Power I I Q Total Reactive Power I I S Total Apparent Power I xxx A / 5 A I xxx A / 1 A xxx V / xxx V EQxx07C Active, reactive, apparent power meters & YQxx07C Power factor meters 7

YQXX07 GENERAL ORDERING CODE Type Class Zero Position Connection Nominal Voltage Nominal Current Frequency Range Auxiliary Supply Current connection Service Comm. Finish Window YQxx07 x x x x x x x x x x x x x x x x x x I I I I I I I I I I I I I I I I I I A 0.5 / 1 / 0.5 * I I I I I I I I I I I I I I I I I I B 0.3 / 1 / 0.3 I I I I I I I I I I I I I I I I I I C 0.3 / 1 / 0.8 I I I I I I I I I I I I I I I I I I D 0.8 / 1 / 0.3 I I I I I I I I I I I I I I I I I I X I 0.1 / 1 / 0 / 1 / 0.1 E I I I I I I I I I I I I I I I I I I Y Custom (appendix) I I I I I I I I I I I I I I I I I xxxa/5a I I I I I I I I I I I I I I I I I xxxa/1a I I I I I I I I I I I I I I I I xxxv/xxxv I I I I I I I I I I I I I I I Y Yes * I I I I I I I I I I I I I I I N No I I I I I I I I I I I I I I S Black * I I I I I I I I I I I I I I W White Not available if Finish is P, G, R or V I I I I I I I I I I I I I S Single Scale * I I I I I I I I I I I I I D Double Scale I I I I I I I I I I I I S Standard with Scale * I I I I I I I I I I I I N Bianco Dial I I I I I I I I I I I I X No Dial I I I I I I I I I I I A Clear Glass * I I I I I I I I I I I B Clear Glass + Red Adj. Index I I I I I I I I I I I L Anti Glare Glass I I I I I I I I I I I D Anti Glare + Red Adj. Index I I I I I I I I I I A Standard * I I I I I I I I I I H HVE (Tropical Seal) I I I I I I I I I I M Inc. Mech. Resistance I I I I I I I I I I S Ship Ver. I I I I I I I I I I P IP54 I I I I I I I I I I G HVE + IP54 I I I I I I I I I I R Ship Ver. + IP54 I I I I I I I I I I T Ship Ver. + HVE I I I I I I I I I I V Ship Ver. + HVE+IP54 I I I I I I I I I N Without * I I I I I I I I I M Mini USB I I I I I I I I T Through Hole Transformer * I I I I I I I I C Screw Terminal Connector I I I I I I I X Internal L1 N I I I I I I I Y Internal L1 L2 I I I I I I I A E 57,7 V I I I I I I I B E 63,5 V I I I I I I I C E 100 V I I I I I I I D E 110 V I I I I I I I E E 230 V I I I I I I I F E 400 V I I I I I I I J E 440 V I I I I I I S 50 Hz * I I I I I I T 60 Hz I I I I I I R 45 65 Hz I I I I I 1A 1 A I I I I I 5A 5 A I I I I 57P7 57,7 V L N \ 100L 100 V L L \ 57V7 57,7/100 V \ I I I I 63P5 63,5 V L N I 110L 110 V L L I 63V5 63,5/110 V I I I I I 66P4 66,4 V L N I 115L 115 V L L I 66V4 66,4/115 V I I I I I 69P3 69,3 V L N I 120L 120 V L L I 69V4 69,3/120 V I I I I I 127P 127 V L N I 190L 190.5 V L L I 110V 110/190 V I I I I I 130P 130 V L N I 220L 220 V L L I 120V 120/208 V I I I I I 127P 127 V L N 1B 225L 225 V L L I 127V 127/220 V I I I I I 130P 130 V L N Connect. 230L 230 V L L 3B and 3U 130V 130/225 V 4B and 4U I I I I 132P 132 V L N I 380L 380 V L L Connect. 132V 132/230 V Connect. I I I I 220P 220 V L N I 400L 400 V L L I 220V 220/380 V I I I I I 230P 230 V L N I 415L 415 V L L I 230V 230/400 V I I I I I 240P 240 V L N I 440L 440 V L L I 240V 240/415 V I I I I I 250P 250 V L N I 450L 450 V L L I 254V 254/440 V I I I I I 254P 254 V L N / 460L 460 V L L I 277V 277/480 V I I I I I 470L 470 V L L I 288V 288/500 V / I I I I 480L 480 V L L I I I I I 500L 500 V L L / I I I 1B Single phase I I I 3B 3 phase 3 wire balanced I I I 3U 3 phase 3 wire unbalanced I I I 4B 3 phase 4 wire balanced I I I 4U 3 phase 4 wire unbalanced I I L 0 / 1 * I S 1.5 * I H 1.0 YQ0107 Power Factor meter 144 mm 90 YQ0207 Power Factor meter 96 mm 90 YQ2107 Power Factor meter 144 mm 270 YQ2207 Power Factor meter 96 mm 270 * Default ordering value Dial Index Type Zero Adjuster Colour Protection Cover VT ratio CT Ratio Scale Base 8 EQxx07C Active, reactive, apparent power meters & YQxx07C Power factor meters

Printed in Slovenia Subject to change without notice Version 4.00 / Jun 2017 GB P 22.430.080 EQxx07C Active, reactive, apparent power meters & YQxx07C Power factor meters 9