Discharge studies in Micromegas detectors in low energy hadron beams

Similar documents
Micromegas detectors & the Great Pyramid. S. Procureur

Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode

Near detector tracker concepts. D. Karlen / U. Vic. & TRIUMF T2K ND280m meeting August 22, 2004

Neutron imaging with a Micromegas detector

The Cylindrical GEM detector for the KLOE-2 Inner Tracker

Micro Pixel Chamber with resistive electrodes for spark reduction

Neutron Structure Functions and a Radial Time Projection Chamber

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

PoS(EPS-HEP2015)232. Performance of a 1 m 2 Micromegas Detector Using Argon and Neon based Drift Gases

ATLAS New Small Wheel Phase I Upgrade: Detector and Electronics Performance Analysis

PANDA Muon System Prototype

A fast triple GEM detector for high-rate charged-particle triggering

Results with Micromegas modules at LP-TPC

Breakdown limit studies in high-rate gaseous detectors

Electron transparency, ion transparency and ion feedback of a 3M GEM

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

The experiment at JINR: status and physics program

Precision Calibration of Large Area Micromegas Detectors Using Cosmic Muons

Track Resolution Measurements for a Time Projection Chamber with Gas Electron Multiplier Readout

Spatial resolution of a MPGD TPC using the charge dispersion signal

Development of a Time Projection Chamber with GEM technology in IMP. Herun yang Gas detector group

A new detector for neutron beam monitoring

Background optimization for a new spherical gas detector for very light WIMP detection

Light ion recoil detector

Performance studies of MicroMegas for the ATLAS experiment

Charge readout and double phase

Performance of a triple-gem detector for high-rate particle triggering

Particle Energy Loss in Matter

Advances in the Micro-Hole & Strip Plate gaseous detector

A Complete Simulation of a Triple-GEM Detector

Angular resolution of the gaseous micro-pixel detector Gossip

GEM at CERN. Leszek Ropelewski CERN PH-DT2 DT2-ST & TOTEM

The Neutron Structure Function from BoNuS

arxiv: v1 [physics.ins-det] 7 Dec 2018

Spatial Resolution of a Micromegas-TPC Using the Charge Dispersion Signal

Large Bulk Micromegas detectors for TPC applications

arxiv: v2 [nucl-ex] 6 Oct 2008

RTPC Simulation Studies for Tagged Deep Inelastic Experiment. Rachel Montgomery SBS Collaboration Meeting, Jefferson Lab, 22/07/16

arxiv:physics/ v2 [physics.ins-det] 31 Oct 2003

Improvement of Spatial Resolution by Selfconsistent Full Muon Track Reconstruction in Gaseous Detectors

Test-bench for the Characterization of MicroMegas Modules for the T2K ND280 TPC

Kaon Identification at NA62. Institute of Physics Particle, Astroparticle, and Nuclear Physics groups Conference 2015

Triple GEM Detectors for the Forward Tracker in STAR

Detectors in Nuclear and High Energy Physics. RHIG summer student meeting June 2014

Development of a new MeV gamma-ray camera

GEM-based photon detector for RICH applications

Simulation of GEM-TPC Prototype for the Super-FRS Beam Diagnostics System at FAIR

PHOTOELECTRON COLLECTION EFFICIENCY AT HIGH PRESSURE FOR A GAMMA DETECTOR ENVISAGING MEDICAL IMAGING

MTV - S1183 Beam Time Summary. Performance test of MTV new detector : CDC. Yumi Totsuka. Department of Physics, Rikkyo University, Tokyo, Japan

N U C L E O N. Satellite Mission. Present status.

arxiv:physics/ v1 [physics.ins-det] 2 Aug 2000

MINOS. Physics Program and Construction Status. Karol Lang The University of Texas at Austin. YITP: Neutrinos and Implications for Physics Beyond

Neutron Structure Function from BoNuS

GEM: A new concept for electron amplification in gas detectors

Bulk Micromegas detectors for large TPC applications

Equalisation of the PMT response to charge particles for the Lucid detector of the ATLAS experiment

Preparations for BONuS12 experiment

Study of GEM-like detectors with resistive electrodes for RICH applications

Particle Energy Loss in Matter

Micro Pixel Chamber Operation with Gas Electron Multiplier

CLAS12 at Jefferson Lab

Spatial Resolution of a Micromegas-TPC Using the Charge Dispersion Signal

ACTAR TPC: an active target and time projection chamber for nuclear physics

Nuclear Instruments and Methods in Physics Research A

High Energy Electron Radiation Exposure Facility at PSI

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland. First Physics at CMS

arxiv: v1 [physics.ins-det] 10 May 2011

Performance study of the ceramic THGEM *

Study of the HARPO TPC for a high angular resolution g-ray polarimeter in the MeV-GeV energy range. David Attié (CEA/Irfu)

b Physics Prospects For The LHCb Experiment Thomas Ruf for the LHCb Collaboration Introduction Detector Status Physics Program

Performance of the ALICE Muon Trigger system in Pb Pb collisions

The BoNuS Detector. A Radial-Drift GEM TPC. Howard Fenker TPC R&D Meeting LBL, March 24, 2005

arxiv: v1 [physics.ins-det] 3 Jun 2016

Validation of Geant4 Physics Models Using Collision Data from the LHC

& SUN ZhiJia 1;2. Abstract

TREX-DM: a low background Micromegas-based TPC for low-mass WIMP detection

Investigation of nuclear Equation of State (EoS) is an attractive subject not only for nuclear

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Performance of triple GEM tracking detectors in the COMPASS experiment

arxiv: v1 [physics.ins-det] 28 Mar 2016

GEM upgrade of the ALICE TPC. Markus Ball Physics Department E18 Technische Universität München On Behalf of the ALICE TPC upgrade

Recent developments on Micro-Pattern Gaseous Detectors

arxiv:physics/ v2 27 Mar 2001

NA62: Ultra-Rare Kaon Decays

Hybrid Gaseous Detector Module for CEPC-TPC

A complete simulation of a triple-gem detector

IKON, a study of the KN interaction with in flight low momentum kaons

Cross Section of Exclusive π Electro-production from Neutron. Jixie Zhang (CLAS Collaboration) Old Dominion University Sep. 2009

Muon reconstruction performance in ATLAS at Run-2

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

PoS(Vertex 2016)004. ATLAS IBL operational experience

Overview on CERN Test Beam Facilities

Examples for experiments that can be done at the T9 beam line

arxiv: v1 [nucl-ex] 3 Feb 2015

Progress in measuring GMR in unstable nuclei: Decay detector calibration and inverse reaction experiment. J. Button, Y.-W. Lui, and D.H.

A Triple-GEM Telescope for the TOTEM Experiment

Micro-pattern gaseous detectors

ALICE TPC upgrade for High-Rate operations

Detailed performance of the Outer Tracker at LHCb

arxiv: v1 [astro-ph.im] 7 Nov 2011

Transcription:

Discharge studies in Micromegas detectors in low energy hadron beams G. Charles a, M. Anfreville b, S. Aune b, J. Ball a, Y. Bedfer a, M. Boyer b, P. Konczykowski a, F. Kunne a, C. Lahonde-Hamdoun b, L. Cai a, I. Mandjavidze b, C. Marchand a, O. Meunier b, B. Moreno a, H. Moutarde a, D. Neyret a, A. Obertelli a, S. Procureur,a, F. Sabatié a, M. Vandenbroucke a a CEA, Centre de Saclay, Irfu/SPhN, 91191 Gif sur Yvette, France. b CEA, Centre de Saclay, Irfu/Sedi, 91191 Gif sur Yvette, France. Abstract We present measurements of discharge rates in various Micromegas detectors in low energy hadron beams for applications foreseen at the future experiments CLAS12 at JLab and MINOS at GSI. The tests were performed in the T11 beam line of the CERN/PS using hadron beams with momentum between.2 and 3 GeV/c. The discharge probability decreases smoothly below 1 GeV/c, except at some specific energies where narrow peaks are observed. The position of the peaks corresponds to the stop point of protons and heavier particles, predicted by the Geant4 simulation. Discharge rates were also measured using Micromegas prototypes equipped with a GEM foil as foreseen for the COMPASS experiment at CERN. Key words: Micro Pattern Gaseous Detectors, Micromegas, GEM, Discharge, Spark, CLAS12, COMPASS, MINOS, Geant4 PACS: 29.4.Cs, 29.4.Gx 1. Introduction Since its invention in 1996, the Micromegas detector [1] has been studied extensively and widely used in high energy physics. Its ability to withstand high fluxes of particles combined with a low material budget and excellent performance makes it very attractive for modern particle physics experiments. Other characteristics, such as its robustness and low price, were further improved with the bulk manufacturing process [2] developed in 26. Thanks to this new process thin and flexible detectors can now be built and used in cylindrical shape as needed for the future trackers of CLAS12 [3] and MINOS [4] spectrometers, devoted respectively to the study of the nucleon structure and of exotic nuclei. The current limitation of Micromegas mainly comes from the generation of a Email address: Sebastien.Procureur@cea.fr. Preprint submitted to Nucl. Instrum. Meth. A September 19, 211

large number of electron-ion pairs in the gas volume, which can lead to a discharge (or spark) between the micro-mesh and the readout strips. This situation usually occurs with the stopping of highly ionizing particles, coming either from the incident beam or from nuclear interactions in the detector s material [5]. Many studies have already been performed on discharge rates in hadron beams [6, 7], however only at momenta above 5 GeV/c. Measurements below a few GeV/c, needed for the CLAS12 and MINOS experiments are still lacking. In the case of CLAS12, the hadron flux is expected to be of the order of 1 MHz per detector, with more than 9% of hadrons between.1 and 1 GeV/c. 2. Experimental setup 2.1. Beam line The tests took place in the T11 beam line of the CERN Proton Synchroton (PS) in August 21. This line was chosen for its characteristics [8] in: luminosity: the discharge probability usually being of the order of one per million, a beam flux higher than 1 5 per spill is needed for precise measurements, with a beam size of a few cm 2 to match the active area of the detectors; energy range: the beam momentum is easily tunable from.2 to 3 GeV/c, and therefore covers the whole CLAS12 kinematics. T11 delivers beam in one or two spills of.4 s every 5 s. Both polarities of focusing magnets can be used, leading to π or π + beams. In the latter case, a small contamination of (mainly) protons is expected. During the 2 weeks of data taking, more than 27, spills were delivered, corresponding to 3.8 billion particles. 2.2. Prototypes and setup Twelve prototypes built with the bulk technology have been installed and tested simultaneously in the beam line as illustrated in Fig. 1, to compare them in the same running conditions. All the detectors were made from the same,.8 mm thick, Printed Circuit Board (PCB). A woven, stainless steel micro-mesh with 18 micron thick wires separated the 128 micron amplification gap from the 5 mm conversion gap. A 25 micron thick aluminized Mylar was used as the drift electrode. Their other main characteristics are summarized in Table 1. Four detectors placed at the extremities of the setup were used as reference for tracking and beam monitoring in horizontal (X) and vertical (Y) directions. Two detectors were equipped with an additional GEM foil placed respectively at 1 and 2 mm from the micro-mesh, to study the effect of the transfer gap on the discharge rate reduction. One detector was mounted on a rotating structure to measure the impact of the beam angle on the discharge probability. Two prototypes were equipped with different micro-meshes built with 16 (resp. 5) microns wires placed every 56 (resp. 265) microns. Almost all the detectors 2

were built at the Saclay new bulk workshop, except a reference one which was built at CERN. The same gas mixture (95% Ar - 5% ic 4 H 1 in volume) was used during all the test. For each detector, the 14 strips with a 4 micron pitch covered an active area of 5.6 1 cm 2, and were connected to the readout electronics developed for the T2K experiment [9]. The ASIC continuously reads and filters the strip signal and samples it in an analog memory until a trigger occurs. The connection to the detectors was ensured by 15 cm long SAMTEC micro-coaxial cables, having a capacitance of 7 pf/m. The data from the twelve detectors were collected by six Front-End Cards (with four ASICs each) mounted on a T2K Front-End Mezzanine. In spite of very long cables, a S/N ratio of 3 was obtained in this configuration with minimum ionizing particles. For each trigger, 6 consecutive samples were read-out for all of the 1728 electronic channels. An acquisition rate of 15 Hz was achieved. The trigger signal was defined by the coincidence of three 15 15 cm 2 plastic scintillators, two upstream and one downstream of the detectors. This triple coincidence was also used to monitor the beam luminosity on a spill by spill basis. A systematic comparison between the triple and all the double coincidences have been performed, and concluded that the trigger efficiency is very close to 1%. Figure 1: Picture of the experimental setup. 2.3. Discharge monitoring Discharges in the detectors were tagged by measuring rapid changes of the micro-mesh potential through a capacitor [6]. The amplified resulting signal was sent through a discriminator to a CAEN V56N 16-channel VME scaler, and the run duration was given by a 5 Hz clock. A CAEN V2718 VME controller was used to communicate with the DAQ monitored through a LabVIEW user 3

position in beam name main characteristics 1 TFV2-1 X reference 2 TFV2-2 Y reference 3 TFV2-3 (MMGEM2) detector with GEM foil, 2 mm transfer gap 4 TFV2-4 (MMGEM1) detector with GEM foil, 1 mm transfer gap 5 TFV2-5 detector rotating along vertical axis 6 TFV2-7 micro-mesh 56/16 7 TFV2-8 micro-mesh 265/5 (amplification gap: 192 microns) 8 TFV1-3 resistive kapton 9 TFV2-9 drift electrode: standard or woven, stainless steel mesh 1 TFV1-4 CERN bulk 11 TFV2-6 X reference 12 TFV1-2 Y reference Table 1: Specificity of each prototype used. interface. The current scaler values were written at a maximum frequency of 5 Hz into an ASCII file for offline analysis. 3. Calibrations 3.1. Gain measurements The gain of each detector was measured before the beam test as a function of the micro-mesh high voltage. The calibration was performed using a 5.9 kev X-rays from a 55 Fe source for which 225 primary electrons are created on average in a 95% Ar - 5% ic 4 H 1 gas mixture. The extraction of the detector s gain required a prior calibration of the acquisition chain, made through the injection of fixed voltages through a reference capacitance. Similar gains have been obtained for all non GEM detectors, as illustrated for some of them in Fig.2, except the one with a thicker micro-mesh and amplification gap. For the two detectors mounted with a GEM foil (MMGEM) the gain was first measured without the GEM foil. A 2D fit of the gain as a function of GEM and micro-mesh high voltages was then performed for transfer fields 1 of 1 and 3 V/mm. The results are given in Fig.3. 3.2. Luminosity corrections The estimate of the discharge probability per incident particle requires the measurement of the luminosity which is evaluated from the number of coincidences in the scintillators. However, the scintillators are larger than the detectors, and therefore trigger on more particles than seen by the detectors. This effect is emphasized at low momentum where the beam is much wider (see Fig.4). 1 The transfer field is the field between the GEM foil and the micro-mesh. 4

Figure 2: Gains measured as a function of the micro-mesh high voltage for some of the non GEM detectors. The detector with the smallest gains has a thicker micro-mesh and a 192 micron amplification gap. TFV2 3 MM+GEM 2mm (E transfert 1 V/mm) Gain 1 5 HV GEM 24 V HV GEM 26 V HV GEM 28 V HV GEM 3 V HV GEM 32 V 4 1 3 1 26 28 3 32 34 36 38 HV mesh (V) Figure 3: Gains as a function of the micro-mesh high voltage for the MMGEM with a 2 mm transfer gap. The transfer field is 1 V/mm and the GEM high voltage is varied from 24 V to 32 V. Corrections are therefore needed to determine the number of particles going through each detector as a function of the number of coincidences between scintillators N coin. The calculation proceeds in two steps: the 2D beam profiles in the scintillators are first estimated from the extrapolation of 1D profiles in the detectors, the latter coming from gaussian fits of the hit positions. The total number of particles in the spill N spill is thus obtained; 5

Cluster position.35.3.25.2 GeV/c 3 GeV/c.2.15.1.5 2 4 6 8 1 12 14 Strip number Figure 4: Distribution of the hit position in the most upstream detector using 3 GeV/c (full) and.2 GeV/c (hollow) π beam. The two curves are gaussian fits. the number of particles N det i crossing the i th detector for each spill is then calculated from the gaussian profile in the detector. This leads to the following relations: g(µ x, σ x, µ y, σ y ) R N spill = N coin g(µ x, σ x, µ y, σ y ), (1) Sc where g is the 2D normalized gaussian beam profile, µ x, µ y, σ x and σ y are the average positions and the spreads of the beam profiles in X and Y directions. stands for the integration on the scintillators paddles area. Sc The number of particles crossing the detector i is similarly calculated as: g(µ x,det i, σ x,det i, µ y,det i, σ y,det i ) det i N det i = N spill g(µ x,det i, σ x,det i, µ y,det i, σ y,det i ), (2) R where µ det i and σ det i are the mean position and the spread for the i th detector. By combining Eq. 1 and Eq. 2, the number of particles crossing the detector i can be expressed as: g(µ x, σ x, µ y, σ y ) g(µ x,det i, σ x,det i, µ y,det i, σ y,det i ) R N det i = N coin g(µ x, σ x, µ y, σ y ) det i g(µ x,det i, σ x,det i, µ y,det i, σ y,det i ) N coin C Sc R (3) C is defined as the luminosity correction factor, and varies between (high correction) and 1 (small correction). The values obtained are presented in Fig. 6

5. As expected the correction is close to one at 3 GeV/c, where the beam is better focused. It corresponds to a number of particles per spill of the order of 2 1 5. The calculated correction factor evolves smoothly with the beam momentum. It is fitted by α i + β i /p.4, where α i and β i are the fit parameters for the i th detector and p is the beam momentum. The fit is then used to correct for the luminosity. As expected the two fits are very similar, since the two beams differ only by the direction of the magnetic field in the magnets of the T11 beam line 2. Different fitting functions were tried to estimate the systematics associated Luminosity correction factor 1.8.6.4.2 π + - π.5 1 1.5 2 2.5 3 Momentum [GeV/c] Figure 5: Luminosity correction factor (C) for one detector, as a function of the beam momentum, calculated with π + and π data. The curves are fits of the form α + β/p.4. with the correction factor calculation. It lead to systematic errors of the order of 5%, and up to 1 % at low momenta. 4. Discharge probability in standard Micromegas 4.1. Discharge probability as a function of particle type and momentum The discharge probability per incident particle was measured as a function of the beam momentum, and corrected for the luminosity effect. Almost all the detectors exhibited similar discharge probabilities. This is illustrated for three of them in Fig. 6, using a micro-mesh high voltage of 43 V, corresponding to gains above 1 4. Above 1 GeV/c, the discharge probability is independent of the momentum and pion charge, and is of the order of 2 1 5. This value is in agreement with a previous measurement obtained at 15 GeV/c with the same gas mixture [6]. Below 1 GeV/c however, the discharge probability slowly decreases, except at some specific momenta for which large and narrow peaks 2 The proton contamination is too small to change the beam profile. 7

show up in the case of the π + beam. These peaks cannot be explained by any resonances in the pion cross sections. However, the π + beam is slightly contaminated by heavier particles, which is not the case for the π beam. Using a Geant4 simulation of the setup (see section 6), it appears that the position of the three peaks are well compatible with momenta for which protons, deuterons and tritons stop in the detectors. Such particle stopping leads to large energy deposits and therefore to a high discharge probability. This interpretation is confirmed by the observed shifts of the peak positions from one detector to another, caused by the energy loss in the setup. Spark probability Spark probability Spark probability.15.1.5 Detector -3 1 1.8.4.15.1.5 Detector -3-3 1 1, gain = 17 1, gain = 17 Detector 1, gain = 17 Detector 1, gain = 17 + π - π.5 1 1.5 2 2.5 3 Detector 5, gain = 13 Detector 5, gain = 13 Detector 5, Detector gain = 13 5, gain = 13 Momentum [GeV/c].5 1 1.5 2 2.5 3 11, gain = 12 Detector 11, gain = 12 Detector 11, gain = 12 Detector 11, gain = 12 Momentum [GeV/c].5 1 1.5 2 2.5 3 Momentum [GeV/c] Figure 6: Discharge probability as a function of the beam momentum for π (circles) and π + (triangles) for detectors in position 1, 5 and 11. Statistical and systematic errors (from the luminosity correction factor) are included. 4.2. Discharge probability as a function of the conversion gap During the tests, the conversion gap of one detector was varied from 2 to 5 mm to study the effect of this gap on the discharge probability. Previous tests were performed on this parameter, but no precise conclusion could be reached as they did not make use of the same detector. At a fixed gain, the discharge probability should depend only weakly on the conversion gap. According to the simulation, a small fraction of the highly ionizing particles are indeed created by 8

nuclear interactions with the gas volume. The result on the discharge probability is shown in Fig. 7 using 3 GeV/c π. No significant trend is observed within the error bars. Measurements at several different gains yield the same conclusion. Spark probability 1 1 8 6 4 2-6 gain = 64 2 2.5 3 3.5 4 4.5 5 Conversion gap [mm] Figure 7: Discharge probability as a function of the conversion gap height for 3 GeV/c π beam. Statistical and systematic errors are included. 5. Discharge probability in MMGEM detectors Previous studies showed that the discharge probability of a Micromegas equipped with a GEM foil (MMGEM) is reduced by a factor of 1 to 1 compared to a standard Micromegas at the same total gain. The reduction proved that the relevant parameter in the discharge development is not the total number of electrons, but more likely a local charge density. To better understand the effect of the transfer gap and of the GEM pre-amplification, two MMGEMs with 1 and 2 mm gaps were studied for various GEM high voltages. The measured discharge probabilities as a function of the total gain are presented in Fig. 8 and compared with a standard Micromegas using 3 GeV/c π. From Fig. 8.a) to 8.f) the HV difference of the GEM foil is increased by steps of 2 V starting from 24 V. At moderate GEM gains (first two plots), a large reduction of the discharge probability is already observed compared to the standard Micromegas, but there is no significant difference between the two MMGEMs. Therefore the transverse diffusion in the transfer gap, affecting mostly the electrons created in the conversion gap, does not change the discharge probability. This suggests that the discharges occurring in this regime mainly come from large energy deposits in the transfer gap. These deposits being amplified only by the Micromegas gain, they are dramatically suppressed by transferring part of the gain to the GEM 9

Figure 8: Discharge probability as a function of the total gain for the two MMGEMs and a standard Micromegas with 3 GeV/c π. From a) to f) the GEM high voltage is increased by steps of 2 V, with a constant transfer field of 3 V/mm for the two MMGEMs. foil. At higher GEM gains however, the discharge probability is further reduced in the MMGEM with the largest transfer gap. It indicates that the discharges originating from the transfer gap have been suppressed enough to be sensitive to discharges coming from the conversion gap. Not surprisingly, these discharges are better suppressed with a larger transverse diffusion. The relevant parameter in the development of a discharge is therefore a local charge density rather than a total number of electrons. 6. Geant4 simulation of the discharge probability Simulations have been performed to understand the variations of the discharge rate with the beam momentum in the case of positively charged particles. In Geant4 simulations, a discharge is associated with a local, large energy deposit in the detector, as detailed in [5]. The large energy deposits occur from highly ionizing particles, usually produced from nuclear interactions between the detector material and the incident beam particles. In addition incident low energy particles can themselves be highly ionizing. For example, 29 MeV/c protons usually stop in the very first detector. In this configuration, this detector is likely to record large discharge rates. Increasing the beam momentum by a few MeV/c will lead protons to stop in the following detectors, thus leading to a very rapid increase of their discharge rate. This is exactly what is seen around 3 MeV/c (see Fig. 6) where the narrow peaks are slightly shifted in momentum from one detector to another. Similar simulations with heavier positively charged particles show that the stopping of deuterons (resp. tritons) occurs around 5 (resp. 65) Mev/c, again very close to the momentum of the second and third peaks of Fig. 6. The discharge probabilities obtained from the simulation for pions, protons, deuterons and tritons are shown in Fig.9 as a function of the beam momentum. 1

Except for pions, it is not possible to quantitatively compare with the data since the contamination of the beam with heavier particles is poorly known. The contaminations introduced in the simulation for protons, deuterons and tritons were therefore tuned to reproduce the amplitudes of the three peaks. From this tuning, it turns out that the ratio between proton and deuteron contaminations ( 7) is the same as between deuteron and triton, which is reasonable. Concerning protons, the tuning leads to a.5% contamination of the π + beam. This is in disagreement with an old simulation of the T11 line [8] which predicted a contamination of the order of 1%. However, systematic flux measurements performed in the scintillators located upstream and downstream of the detectors agreed within 1% even with the 3 MeV/c π + beam. In this configuration, protons can only be seen by the upstream scintillators, meaning that the proton contamination should be smaller than 1%. The value obtained from the tuning of the simulation agrees with this observation. For pions, the simulation gives the correct order of magnitude for the discharge probability, using a Raether limit of 4 1 7. This limit is similar to the one used in [5], i.e. 2 1 7, and therefore confirms the ability of the simulation to predict the correct order of magnitude for the discharge rate. Discharge probability.8 1.7.6.5.4.3.2.1-3 π- π+ protons (.5%) deuterons (.7%) tritons (.1%) Detector 5 (G=13,) 5 1 15 2 25 3 Momentum [MeV/c] Figure 9: Geant4 simulation of the discharge probability as a function of the beam momentum obtained for different particles, in the detector 5 (with a gain of 13,). Protons, deuterons and tritons are scaled to represent.5%,.7% and.1% of the π+ beam, respectively. 11

7. Conclusion Measurements of discharge rates in Micromegas have been performed at beam energies between.2 and 3 GeV/c. Large variations of the discharge probability have been observed with π+ beam below 1 GeV/c. These variations are well described by a Geant4 simulation, confirming its reliability for discharge rate predictions. Systematic studies also lead to a better understanding of the origin of the discharge reduction in Micromegas equipped with a GEM foil. The measurements at moderate GEM gains suggest that the discharges in MMGEMs are generated mainly by large energy deposits in the transfer gap. At high GEM gains however, discharges originating from the conversion gap become predominant. In this configuration, the transverse diffusion in the transfer gap plays an important role to further reduce the discharge rates. All these results are of particular importance for the application of Micromegas detectors for high luminosity and low energy experiments. Acknowledgments We are particularly grateful to Lau Gatignon for useful discussions before and during these tests to optimize the setup and for the beam tuning. Special thanks are due to Horst Breuker for the dedicated beam time granted on the T11 line. We also thank J. Duplessy and B. Pichler for their help on safety issues. References [1] Y. Giomataris et al., Nucl. Instrum. Methods A 376 (1996) 29 [2] Y. Giomataris et al., Nucl. Instrum. Methods A 56 (26) 45-48 [3] S. Aune et al., Nucl. Instrum. Methods A 64 (29) 53-55 [4] A. Obertelli, ERC-Starting Grant 21, 258567-MINOS [5] S. Procureur et al., Nucl. Instrum. Methods A 621 (21) 177 [6] D. Thers et al., Nucl. Instrum. Methods A 469 (21) 133 [7] S. Procureur et al., submitted in Nucl. Instrum. Methods A [8] O. Ferrando, http://gatignon.web.cern.ch/gatignon/eastarea/docs/t11 Guide.pdf [9] P. Baron et al., IEEE Trans.Nucl.Sci.55:1744-1752, 28 12