PoS(EPS-HEP2015)232. Performance of a 1 m 2 Micromegas Detector Using Argon and Neon based Drift Gases

Similar documents
Precision Calibration of Large Area Micromegas Detectors Using Cosmic Muons

Improvement of Spatial Resolution by Selfconsistent Full Muon Track Reconstruction in Gaseous Detectors

Performance studies of MicroMegas for the ATLAS experiment

R&D and related Simulation Studies for the sphenix Time Projection Chamber

Track Resolution Measurements for a Time Projection Chamber with Gas Electron Multiplier Readout

Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode

Angular resolution of the gaseous micro-pixel detector Gossip

Muon reconstruction performance in ATLAS at Run-2

arxiv:hep-ex/ v1 16 Dec 2000

Simulation of GEM-TPC Prototype for the Super-FRS Beam Diagnostics System at FAIR

Spatial Resolution of a Micromegas-TPC Using the Charge Dispersion Signal

3 Gaseous Detectors. Detectors for Particle Physics Manfred Krammer Institute for High Energy Physics, Vienna, Austria

Spatial resolution of a MPGD TPC using the charge dispersion signal

HIGH energy physics research requires a constant improvement

Development of a Time Projection Chamber with GEM technology in IMP. Herun yang Gas detector group

Particle Energy Loss in Matter

Electron transparency, ion transparency and ion feedback of a 3M GEM

TPC-like analysis for thermal neutron detection using a GEMdetector

A Complete Simulation of a Triple-GEM Detector

The Short Baseline Neutrino Program at Fermilab

Test-bench for the Characterization of MicroMegas Modules for the T2K ND280 TPC

ATLAS New Small Wheel Phase I Upgrade: Detector and Electronics Performance Analysis

arxiv:physics/ v2 27 Mar 2001

Development of Precision Muon Drift Tube Detectors for the High-Luminosity Upgrade of the LHC

A complete simulation of a triple-gem detector

Detecting low energy recoils with Micromegas

Breakdown limit studies in high-rate gaseous detectors

GEM at CERN. Leszek Ropelewski CERN PH-DT2 DT2-ST & TOTEM

arxiv:physics/ v2 [physics.ins-det] 31 Oct 2003

Experimental Methods of Particle Physics

Particle Energy Loss in Matter

Near detector tracker concepts. D. Karlen / U. Vic. & TRIUMF T2K ND280m meeting August 22, 2004

PoS(ICHEP2016)293. The LArIAT experiment and the charged pion total interaction cross section results on liquid argon. Animesh Chatterjee

The NUCLEON Space Experiment Preliminary Results. Skobeltsyn Institute of Nuclear Physics, Moscow State University, Moscow, , Russia

Characteristics of Forbush decreases measured by means of the new scintillation muon hodoscope ScMH

for the HARPO Collaboration: *

Status and Challenges of CEPC Time Projection Chamber Detector. Huirong On behalf of CEPC Tracking Subgroup

Signals in Particle Detectors (1/2?)

ACTAR TPC: an active target and time projection chamber for nuclear physics

SUMMER STUDENT PROGRAM

A Triple-GEM Telescope for the TOTEM Experiment

Performance of the Gamma-ray Imaging Detector with Micro-TPC

GEM: A new concept for electron amplification in gas detectors

Evaluation and reduction of ion back-flow in multi-gem detectors

Measurement of the transverse diffusion coefficient of charge in liquid xenon

Study of the HARPO TPC for a high angular resolution g-ray polarimeter in the MeV-GeV energy range. David Attié (CEA/Irfu)

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Neutrino oscillation physics potential of Hyper-Kamiokande

Advances in the Micro-Hole & Strip Plate gaseous detector

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Spatial Resolution of a Micromegas-TPC Using the Charge Dispersion Signal

Study on Surface Asperities in Bakelite-RPC

Particle Detectors. History of Instrumentation History of Particle Physics. The Real World of Particles. Interaction of Particles with Matter

PoS(HCP2009)042. Status of the ALICE Experiment. Werner Riegler. For the ALICE Collaboration. CERN

The Fast Interaction Trigger Upgrade for ALICE

Ion feedback suppression using inclined MCP holes in a Single-MCP+Micromegas+Pads Detector *

MICROMEGAS Signal: Numerical Simulation Based on Neon-Isobutane and Neon-DME

GEM upgrade of the ALICE TPC. Markus Ball Physics Department E18 Technische Universität München On Behalf of the ALICE TPC upgrade

Status and Plans of the Large TPC Prototype for the ILC

Results with Micromegas modules at LP-TPC

arxiv: v1 [physics.ins-det] 5 Nov 2015

Micromegas detectors & the Great Pyramid. S. Procureur

Micro-pattern gaseous detectors

Neutron imaging with a Micromegas detector

Near Detector Tracker. Dean Karlen / U. Victoria & TRIUMF NP04 Neutrino Session - KEK August 25, 2004

A novel design of the MeV gamma-ray imaging detector with Micro-TPC

PoS(EPS-HEP2015)522. The status of MICE Step IV

arxiv: v1 [physics.ins-det] 29 Jun 2011

arxiv: v1 [physics.ins-det] 7 Dec 2018

The cosmic ray muon tomography facility based on large scale MRPC detectors

Background optimization for a new spherical gas detector for very light WIMP detection

GRAINE Project: a balloon-borne emulsion gamma-ray telescope

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

The outline. 1) Detector parameters: efficiency, geometrical acceptance, dead-time, resolution, linearity. 2) gaseous ionization chambers

arxiv: v1 [physics.ins-det] 28 Mar 2016

This is a repository copy of TACTIC : The TRIUMF Annular Chamber for Tracking and Identification of Charged particles.

Investigation of nuclear Equation of State (EoS) is an attractive subject not only for nuclear

PHYS 3446 Lecture #12

PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group

The ATLAS Detector - Inside Out Julia I. Hofmann

Charge readout and double phase

Status and Perspectives for KM3NeT/ORCA

Experimental Particle Physics

& SUN ZhiJia 1;2. Abstract

Summer Student Project Report

Pressure effect in the X-ray intrinsic position resolution in noble gases and mixtures

The Silicon-Tungsten Tracker of the DAMPE Mission

MICROMEGAS PERFORMANCE BASED IN ARGON- ISOBUTANE AND ARGON-DEMETHYL-ETHER

A fast triple GEM detector for high-rate charged-particle triggering

Neutrino Detectors for future facilities - III

Micro Pixel Chamber Operation with Gas Electron Multiplier

A new detector for neutron beam monitoring

Drift plane. substrate (20ÉIm polyimide) 200ÉIm. Back strip (180ÉIm width) Base (Ceramic) Anode strip (10ÉIm width) Cathode strip (100ÉIm width)

PHOTOELECTRON COLLECTION EFFICIENCY AT HIGH PRESSURE FOR A GAMMA DETECTOR ENVISAGING MEDICAL IMAGING

08 - Miscellaneous and historical detectors

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Alignment of the ATLAS Inner Detector tracking system

PoS(RPC2012)034. Simulation studies on the Effect of SF 6 in the RPC gas mixture

TECHNIQUE OF MEASURING THE FIRST IONIZATION COEFFICIENT IN GASES

Tracking detectors for the LHC. Peter Kluit (NIKHEF)

Transcription:

Performance of a m Micromegas Detector Using Argon and Neon based Drift Gases a, Otmar Biebel a, Jonathan Bortfeldt a, Ralf Hertenberger a, Ralph Müller a and Andre Zibell b a Ludwig-Maximilians-Universität München, Germany b Bayerische Julius-Maximilians-Universität Würzburg, Germany E-mail: Philipp.Loesel@physik.uni-muenchen.de Micromegas (MICRO MEsh GAseous Structures) are used in a broad field of applications due to their excellent spatial resolution and single plane track inclination reconstruction capability. They consist of three planar structures, a cathode, a micro-mesh and a strip anode with.5 mm modularity. The distance of the micro-mesh from the cathode is with typically 5 mm large in comparison to the tiny distance of. mm to the anode, thus creating a drift and amplification region with electric fields differing by a factor of more than 5 and thus increasing the electron transparency of the micro-mesh well above its optical transparency. Position information is obtained by the charge center on the responding anode strips. Alternatively in a TPC-like mode, the track of the incident particle can be reconstructed measuring the drift times of the ionization electrons as a function of the position of the responding anode strip. We report on the performance of a m Micromegas with electronic channels using detector gases based on Ar:CO or Ne:CF mixtures. Central questions are hereby: homogeneity of pulse height and efficiency, mesh transparency, calibration possibility of the location of single readout strips using cosmic muons and the impact of the drift time on the angular and spatial resolution as a function of the incident angle. PoS(EPS-HEP5)3 The European Physical Society Conference on High Energy Physics -9 July 5 Vienna, Austria Speaker. c Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives. International License (CC BY-NC-ND.). http://pos.sissa.it/

Performance of a m Micromegas Using Different Drift Gases. Introduction Micromegas detectors (MICRO MEsh GAseous Structure) detectors are gaseous detectors consisting of three planar elements: cathode, micro-mesh and anode structure, in our case with a stainless steel mesh and a strip anode with a pitch of 5 µm. The related electron drift and amplification region are 5 mm and µm high. Charge created by a traversing muon is collected on the resistive strips and readout via capacitive coupling to readout strips []. Position information is obtained by the charge center of the responding anode-strips, the socalled centroid: x cen = strips x strip q strip strips q strip. Measuring the. mm resistive strips readout strips m resistive strip Micromegas detector 5 mm ionization cluster t drift cathode U drift drift pillar mesh V amplification anode U ampl Figure : Schematic drawing of a muon traversing a Micromegas detector divided in drift and amplification region by a grounded micro-mesh. drift time of the ionization electrons versus the position of the strips enables track angle Θ reconstruction in a single plane using the so-called µtpc method. With the known strip pitch and drift velocity obtained from MAGBLOTZ [] this leads to the track angle Θ = arctan( slope f it pitch v dri ft ). Depending on the drift velocity for different gas mixtures, position and angle reconstruction was investigated using Ar:CO vol% and Ne:CF : vol% at atmospheric pressure. The gas mixture has to be chosen appropriate to the application. A higher drift velocity, e.g. improves the high-rate capability.. Experimental Setup Trigger scintillators MDT reference Chamber Micromegas under test MDT reference Chamber z y x APV APV5 APV APV7 M S M S M S M S M S M S M S M S connector 3 5 7 9 3 5 readout area gas out scintillator readout side scintillators 3 5 7 APV cm APV APV APV3 APV readout electronics APV APV9 APV APV APV APV3 APV APV5 z x y PoS(EPS-HEP5)3 Trigger scintillators 9 gas in 9cm active area open strip side Figure : (left) Scheme of the Cosmic Ray Measurement Facility in Garching consisting of two trigger hodoscopes with cm spatial segmentation, two MDT reference chambers and the Micromegas under test. (right) Scheme of the m Micromegas under test with its subdivision into partitions of 5.7 cm ( APV scintillators). This measurement took place in the LMU Cosmic Ray Measurement Facility (CRMF) consisting of two Monitored Drift Tube (MDT) reference tracking chambers and two trigger scintillator

Performance of a m Micromegas Using Different Drift Gases hodoscopes for the second coordinate (see fig. (left)). The MDTs have an active area of about 9 m and are sandwiching the Micromegas. The angular acceptance is 3 to +3. Therefore the investigation of the whole active area of the Micromegas is possible. The Micromegas under test has an active area of.9.m, strips channels with a pitch of 5 µm and was read out with APV5 front-end boards [3] interlinked to Front-End Concentrator cards and a Scalable Readout Unit of the RD5 Scalable Readout System []. The front-end boards together with the second coordinate obtained from the trigger hodoscopes along the strips allow a subdivision of the Micromegas in partitions (see fig. (right)). 3. Spatial Resolution - Centroid Method The difference between the muon position predicted by the MDTs and the reconstructed position of the Micromegas is called residual. In this case the standard deviation of the Gaussian-like residual distribution is used as approximation for the spatial resolution. Figure 3 shows the measured spatial resolution for the different gas mixtures and drift fields. For tracks perpendicular to the Micromegas the spatial resolution is almost constant at.5 mm limited by the multiple scattering of GeV muons. In a testbeam with GeV pions (CERN SPS H) a spatial resolution of 9 µm was achieved for this Micromegas. The larger the track angle the larger gets the spatial resolution. Ar:CO vol% shows a better spatial resolution for lower drift fields, almost constant for = 5 V/cm due the drift field dependence of the diffusion. For Ne:CF : vol% no drift field dependence can be seen, because the dependence of the diffusion on the drift field in this gas mixture is much weaker. The spatial resolution is similar to the one for Ar:CO vol% at = V/cm. sigma of residual distribution [mm]. = 5V/cm = V/cm = V/cm = V/cm E = V/cm.9 drift..7..5 sigma of residual distribution [mm]..9..7..5-3 - - 3-3 - - 3 = 5V/cm = V/cm = V/cm = V/cm PoS(EPS-HEP5)3 Figure 3: Measured spatial resolution as a function of the reference track angle for different drift fields for Ar:CO at E ampl =.5kV/cm (left) and Ne:CF : at E ampl =.kv/cm (right).. Electron Transparency of the Mesh The micro-mesh of a Micromegas has typically an optical transparency around 5 %. Due to the large ratio between amplification and drift field the electron transparency can be increased to almost %. The electron transparency of a woven stainless steel mesh with 3.5 µm pitch and µm wire diameter was simulated as a function of the drift field for different gas mixtures using Garfield++ [5]. In Figure (left) the decrease of the electron transparency with the drift field is shown. For Ne:CF : vol% the decrease is less rapid than for Ar:CO vol%. This 3

Performance of a m Micromegas Using Different Drift Gases can also be seen in the behavior of the most probable value of the pulse height distribution (see fig. (right)). The rise of the pulse height with increasing field is due to decreasing attachment and increasing drift velocity, leading to a better matching between electronics integration time and signal duration. transparency.9..7..5. Ar:CO : Ne:CF.3 5 5 5 3 [V/cm] MPV of pulse height distribution [arb. units] Ar:CO Ne:CF : [V/cm] Figure : Simulated electron transparency (left) and measured most probable pulse height (right) as a function of the drift field for different gas mixtures. 5. Efficiency The efficiency of a Micromegas depends, among others, on the electron transparency of the micro-mesh. 95 A traversing muon is considered as efficiently detected 9 if the residual is smaller than 3σ spatial resolution. Figure 5 5 shows ɛ 3σ as a function of the drift field for both drift gas mixtures. Ar:CO vol% at low drift fields 75 shows lower efficiency due to the before mentioned integration 7 time effect. For higher drift fields both gas 5 Ar:CO mixtures have good efficiency above 9 %. The maximum of 93 % results from multiple scattering of muons 55 Ne:CF : exceeding the 3σ spatial resolution range. [V/cm] For each of the partitions of the detector ɛ 3σ was Figure 5: 3σ efficiency as a function of individually determined. Two examples at = the drift field for different gas mixtures. V/cm are plotted in figure. Both show a good homogeneity with an RMS of about %. efficiency [%] PoS(EPS-HEP5)3 y [57. mm] 9.3 9. 9. 9.7 9.5 9.5 9. 9. 9. 9.3 9. 9.57 9. 93. 9.7 9.7 9. 9. 9. 9.3 93.9 93.5 9. 9.7 9. 9.3 9.99 93.3 93 9.7 9. 9.75 9. 9.57 9.9 9.3 9. 9. 9. 9. 93.3 93. 93.7 93.75 9. 93.3 9. 9.3 93. 9.59 9.7 9. 9.5 9.5 9. 9.79 9. 9.3 9.9 9.9 9. 93. 93.9 93.5 93.5 93. 93. 93.7 93. 9.5 9.7 9. 9.9 9. 9.3 9. 9.9 9. 9.97 9.9 9. 93.5 93.3 93. 9. 9. 9.3 93.7 9.57 9.5 9. 9.3 9. 9.9 9. 9.97 9.9 9.9 9.39 9.5 9. 9. 9. 9.5 9.3 9.3 9.3 9.7 9. 9. 9.79 9.9 9.55 9.59 9.5 9.99 9.5 9. 9.3 9. 9.7 9.9 93.5 9.57 9. 93.7 9.5 9.55 9.7 9. 9.99 9. 9.55 9. 9.5 9. 9. 9.7 9.9 9.5 9.95 9.7 93. 9.99 9. 9. 9. 9.9 93.5 9. 9. 9.7 9. 9.7 9.3 9.9 9.3 9.93 9.93 9.7 3 5 7 9 x [ mm] 9 93 9 9 9 9 7 5 Efficiency [%] y [57. mm].9 9. 9.5 9.5 9.3 9. 9.77.3.9 5. 9.9 9. 9.7 9. 9.33 9.9 9.5 9.3 7.9 7.57 9. 9. 9.9 9. 9.79 9.77 9. 9.7 9. 9..7 9.7 9.3 9 9.75 9.3 9.7 9.5 9..7 9. 9. 9. 9. 93. 9.7 9.59 9.7 9.3 9.57.9 9.7 9 9.55 9.5 9.5 9.9 9.5 9.9 9.3 9. 9. 9.7 93. 93 93.9 93.7 9.57 9.5 9. 9.7 9.57 9.3 9.9 9.9 9.97 9.9 9.7 9.3 9.3 9.7 9.79 9.7 9. 9.7 9.9 9.53 9.7 9.7 9.5. 9.3 9.57 9. 9. 9.9 9. 9. 9.9 9.33 9.5 9. 9.75 9. 9.3 9.37 9.9 9.3 9.37 9.5.7 9.5 9 9.7 9.55 9.9 9.39 9.9 9.77 9.7.3. 9.9 9.5 9. 9. 9.9 9. 9. 9. 9. 9.7 9.75 9. 9. 9. 9.9 9. 9. 9. 9.77 9. 9. 9.5 9. 9.93 9.53 9.7 9.7 9. 9.7.99 9.7 9. 9. 9. 9. 9. 9.3 9.9 3 5 7 9 x [ mm] 9 93 9 9 9 9 7 5 Efficiency [%] Figure : Measured homogeneity of ɛ 3σ for Ar:CO (left) and Ne:CF : (right).

Performance of a m Micromegas Using Different Drift Gases. Variation of Drift Velocity due to Deformed Drift Region gas in tracks cathode reconstructed z position mesh stiff base plate gas out z [mm]..3.. -. -. -.3 9 7 5 3 y [57. mm] x [ mm] Figure 7: Schematic drawing of the deformation of the drift region with reconstructed z position (left) and measured z position for all partitions of the Micromegas (right). Due to the small overpressure of about mbar in the Micromegas the drift region is slightly deformed (see fig. 7 (left)). The effective z position of its sensitive layer can be determined using inclined tracks for each of the partitions of the detector and is shown in figure 7 (right). Since the stiff base plate support does not deform like the cathode, the deviation in height is inhomogeneous. The maximum deviation of. mm from the plane leads to a deviation of. mm at the drift cathode. Therefore the drift field [cm/ns] V drift..... Ar:CO Ne:CF :. 5 5 5 3 [V/cm] Figure : Simulated electron drift velocity as a function of the drift field for different gas mixtures. has to be determined for each partition separately and thus the drift velocity. Figure shows the drift velocity as a function of the drift field for different gas mixtures simulated with MAGBLOTZ. 7. Angle Reconstruction using the µtpc Method The track angle can be reconstructed within a single detector plane by measuring the arrival time of the ionization electrons reaching the strips. This leads together with the strip pitch and the drift velocity, calculated for each detector partition, directly to the track angle. A simulation of the readout circuit has shown a signal crosstalk of 9 % to the neighboring strips. After correcting for this effect the angle reconstruction for Ne:CF : vol% improves, especially with higher drift fields for the smaller angles (see fig. 9b). For Ar:CO vol% (see fig. 9a) and drift fields above 3 V/cm the reconstruction works as well. But for data points at 3 V/cm the variation of the drift velocity is probably too large within the partitions such that the drift velocity was estimated too small. The presented measurement can be used to correct the systematic deviation from the bisecting line in figure 9 for specific applications..3.. -. -. -.3 delta Z [mm] PoS(EPS-HEP5)3 5

Performance of a m Micromegas Using Different Drift Gases MPV of reconstructed angle distribution [ ] 35 3 5 5 = 3V/cm = V/cm = V/cm = V/cm MPV of reconstructed angle distribution [ ] E = V/cm 3 drift = V/cm = V/cm = V/cm 5 5 5 5 5 3 5 5 5 3 (a) Ar:CO @ E ampl =.5kV/cm (b) Ne:CF : @ E ampl =.kv/cm Figure 9: Reconstructed track angle as a function of the reference track angle for different drift fields and gas mixtures. The blue line is the angle bisector.. Summary The investigation of a m Micromegas in the LMU Cosmic Ray Measurement Facility with Ar:CO vol% and Ne:CF : vol%, under variation of the drift field was shown. Ne:CF : vol% has shown an almost equal spatial resolution for all drift fields. Both gas mixture show a homogeneous efficiency above 9 % for drift fields larger than V/cm. Ar:CO vol% has a larger pulse height variation due to an imperfect matching between electronics integration time and signal duration at low fields and lower transparency. After correction of capacitive coupling between strips the angle reconstruction works well for Ne:CF : vol% at all drift fields. Acknowledgments We acknowledge the support by the DFG Excellence Cluster Origin and Structure of the Universe. References [] Y. Giomataris et al., Micromegas: a high-granularity position sensitive gaseous detecor for high particle-flux environments, Nucl. Instr. Meth. A 37 9 35 (99). [] S.F. Biagi, Monte Carlo simulation of electron drift and diffusion in counting gases under the influence of electric and magnetic fields, Nucl. Instr. Meth. A 3 (999). [3] L. Jones, APV5-S User Guide, http://cds.cern.ch/record/99/files/ cer-753.pdf (). [] S. Martoiu et al., Front-end electronics for the Scalable Readout System of RD5, Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) 3 3 (). [5] R. Veenhof, Garfield simulation of gaseous detectors, http://garfield.web.cern.ch/garfield/ (). PoS(EPS-HEP5)3