A compression load cell, with strain gauges, tested as a part of a weighing instrument. Manufacturer : Molen or Precia Molen.

Similar documents
E v a l u a t i o n C e r t i f i c a t e

E C t y p e - e x a m i n a t i o n C e r t i f i c a t e

+ + ( indicator ) + (display, printer, memory)

Type UB1 Load Cell. Option Stainless steel cable gland

Certification of a High Capacity Force Machine for Testing of Load Cells According to OIML R60

9.1 Compatibility of modules for nonautomatic weighing instruments (NAWIs) Common requirements

Load Cell Approval Field and Laboratory Evaluation Manual

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Single point load cells

NEW VSL Conditioning plate!

Z7A. Load cells. Special features. Data sheet. Wiring code

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction

Benefits/Application. Very high-cycle fatigue resistant up to 100 % of nominal load. Extremely robust against side forces and bending moments

Glossary Innovative Measurement Solutions

Morehouse. Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA PH: web: sales:

OIML R 50-3 RECOMMENDATION. Edition 2014 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Guidelines on the Calibration of Automatic Instruments for Weighing Road Vehicles in Motion and Measuring Axle Loads AWICal WIM Guide May 2018

Type examination and testing of 825 non-automatic weighing indicator according to EN Performed for Cardinal Detecto Scale Manufacturing Company

Traceable Mass Determination and Uncertainty Calculation

KINECTRICS NORTH AMERICA INC. TEST REPORT FOR 774-KCMIL 3M TM COMPOSITE CONDUCTOR

Benefits/Application. For static and dynamic tensile and compressive forces. Easy assembling, lots of possibilities. Options/Accessories

Ring-Torsion Load Cells RTB

D a t a s h e e t. F o r c e T r a n s d u c e r. S e r i e s K. ( 4 k N k N ) Benefits/Application. Options/Accessories

OIML R 76-2 RECOMMENDATION. Edition 2007 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Non-automatic weighing instruments

INTERNATIONAL OIML R 61-2 RECOMMENDATION

ED 701 General Industry Pressure Transmitter

Installation guide 862 MIT / MIR

ZF Series Force Transducers

CapaciTorr HV Pumps. making innovation happen,together

Performance characteristics of metallic resistance strain gauges

Humidity Calibration Solutions

A comparison of primary platinum-iridium kilogram mass standards among eighteen European NMIs

SVENSK STANDARD SS-EN ISO 376. Metalliska material Kalibrering av kraftmätdon avsedda för kontroll av maskiner för enaxlig provning (ISO 376:1999)

Humidity Calibration Solutions

T h e rm i s t o r s

INTERNATIONAL OIML R 15 RECOMMENDATION

Understanding uncertainties associated with the 5128A RHapid-Cal Humidity Generator

Specifications. Performance. Mechanical Properties. Optional Accessories SR50. Saddle (CA 10B) (Option) Mount Base. LCR-B-5KNS7 to 50KNS7

PC TOOL FOR DATA ANALYSIS IN CALIBRATION OF SPECIAL WEIGHTS

SHIVAJI UNIVERSITY, KOLHAPUR

Loadcell Calibration - Evaluation of Uncertainties

ACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES

Certificate of Accreditation

OIML D 28 DOCUMENT. Edition 2004 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Conventional value of the result of weighing in air

Infrared Thermometer Calibration A Complete Guide

Guidelines on the Calibration of Static Torque Measuring Devices

OIML R RECOMMENDATION. Edition 2006 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Instruments for measuring the areas of leathers

Standard burettes for verification officers

Check Homework. Reading Quiz Applications Equations of Equilibrium Example Problems Concept Questions Group Problem Solving Attention Quiz

An Introduction to the Differences Between the Two Most Recognized Force Standards

OIML R 51-2 RECOMMENDATION. Edition 2006 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Automatic catchweighing instruments

This specification covers the requirements for product performance, test methods and quality assurance provisions of FG Terminal.

ISO INTERNATIONAL STANDARD

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

16 Appendix 16 Electrical Research Association Report

Renolit stretch ceilings

Integrated Circuits Thermal Test Method Environment Conditions - Natural Convection (Still Air)

OIML R 141 RECOMMENDATION. Edition 2008 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

CapaciTorr HV 200 HIGHLIGHTS

SVENSK STANDARD SS-EN ISO

Automated volume measurement for weihts using acoustic volumeter

Test Report EN (2008)

Blower Motor 3P Connector

Temperature Compensation for MEAS Pressure Sensors

ORGANISATION INTERNATIONALE DE MÉTROLOGIE LÉGALE INTERNATIONAL RECOMMENDATION

DESIGN, DEVELOPMENT, AND COMMISSIONING OF A 120 kn DEADWEIGHT FORCE STANDARD MACHINE

Nanometrology and its role in the development of nanotechnology

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Physics Assessment Unit AS 1

(Round up to the nearest inch.)

INVESTIGATION OF THE CALIBRATION CAPABILITIES OF A 1 KN M AND 10 KN M REFERENCE CALIBRATION MACHINE

Electrical safety testing Checklist

TEMPERATURE COMPENSATION FOR MEAS PRESSURE SENSORS APPLICATION NOTE

PRODUCT DATA SHEET. Eagle Eye Outdoor LED Module 5700K. RoHS Compliant. CUSTOMER :. DATE : REV : Rev. 2.0.

PRODUCT DATA SHEET. Eagle Eye Outdoor LED Module 3000K. RoHS Compliant. CUSTOMER :. DATE : REV : Rev. 1.0.

TEMPERATURE AND HUMIDITY DEPENDENCE ON STABILITY OF TORQUE MEASURING DEVICES Tassanai Sanponpute and Nittaya Arksonnarong

Calibration Traceability Guidelines

High pressure comparison among seven European national laboratories

Certificate of Accreditation

MOY/SCMI/36 SPECIFICATION OF ACCURACY FOR A PRECISION CLINOMETER

Multiphysics Simulations for the design of a Superconducting magnet for proton therapy

Obtaining a Converged Solution with Abaqus

Single Phase Motors Technical Datasheets

APPENDIX G EVALUATION OF MEASUREMENT UNCERTAINTY

Certificate of Accreditation

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

PSMN002-25P; PSMN002-25B

ISO INTERNATIONAL STANDARD

EA-10/14. EA Guidelines on the Calibration of Static Torque Measuring Devices. Publication Reference PURPOSE

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

SHANGHAI MYLCH WINDOWS & DOORS THERMAL PERFORMANCE TEST REPORT

TOP Transfer. Data Sheet. Force transfer standard. Special characteristics. D 20.TOPTRANS.10 en

Uncertainty Workshop: Overview of uncertainty factors in HTGHPs

ValkPitched - Trapezoidal

In data sheets and application notes which still contain NXP or Philips Semiconductors references, use the references to Nexperia, as shown below.

473-SHX Dew Point Mirror

Load Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B

CERTIFICATE OF ACCREDITATION

EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement

Verification for Non-Automatic Weighing Instruments (NAWI)

Transcription:

Test certificate Page 1 of 4 Issued by Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands Notified Body Number 0122 In accordance with Applicant In respect of Paragraph 8.1 of the European Standard on Metrological aspects of non-automatic weighing instruments EN 45501:1992/AC:1993 and by application of the OIML International Recommendation R60 (Edition 1991). The applied error fraction p, meant in the paragraph 3.5.4. of the standard is 0.7. Precia Molen B.V. Franse Akker 1 4824 AL Breda The Netherlands A compression load cell, with strain gauges, tested as a part of a weighing instrument. Manufacturer : Molen or Precia Molen Type : CSP-M- t-..-c..-ss/eex(d)/eex(i) Characteristics Maximum capacity (E max ) Accuracy class Maximum number of load cell verification intervals (n max ) Ratio of minimum LC verification interval Y = E max / V min 5, 10, 25, 40, 60 or 100 t C 1000 2000 3000 3000* 3500 3500* 5000 10000 10000 24000 11666 24000 * = special type with additional type description MB In the description number TC2194 revision 3 further characteristics are described. Nederlands Meetinstituut Hugo de Grootplein 1 3314 EG Dordrecht Telephone +31 78 6332332 Telefax +31 78 6332309 NMi B.V. (Chamber of Commerce no.27.228.701) Subsidiary companies: NMi Van Swinden Laboratorium B.V. (27228703) (27.233.418) Verispect B.V. (27.228.700) This document is issued under the provision that NMi. B.V. nor its subsidiary companies accept any liability. Reproduction of the complete document is allowed. Parts of the document may only be reproduced after written permission.

Test certificate Page 2 of 4 Description and The load cell is described in the description number TC2194 revision 3 and documentation documented in the documentation folder TC2194-3, appertaining to this test certificate. Remarks Summary of the test involved: see Appendix number TC2194 revision 3. This revision test certificate replaces the earlier version(s), including its documentation folder. Dordrecht, 30 June 2008 Ing. C. Oosterman Manager Product Certification

Description Page 3 of 4 1 General information about the load cell All properties of the load cell, whether mentioned or not, may not be in conflict with the standard mentioned in the test certificate. 1.1 Essential parts Description Drawing number Rev. Remarks Load cell assembly CSP-M-40-EEx-C 7.882.005.0.635 0 Mechanical Outline Dimensions Special CSP-M 10t / 100 t 799523 - Mechanical Load cell Assy. type CSP 7.882.005.0.638 0 Electrical Cable: - The load cell is provided with a 4-wire system; - The cable length has to be approximately 10 meters for capacity of 5 t and 10 t; - The cable length has to be approximately 20 meters for capacity of 25, 40, 60 and 100 t; - The cable should be a shielded cable, the shield is connected to the load cell. 1.2 Essential characteristics Minimum dead load : 0 kg Safe overload : 150 % of E max Rated Output : 2 mv/v Input impedance : 450 Ω ± 4.5 Ω Output impedance : 480 Ω ± 4.8 Ω Recommended excitation : 5-20 V DC/AC Excitation maximum : 25 V DC/AC See also drawing Specifications load cell CSP-M-..t-., drawing number HV-930217.079. 1.3 Essential shapes The load cell is built according to the drawings: - Load cell assembly CSP-M-40-EEx-C, drawing number 7.882.005.0.635; - Outline Dimensions Special CSP-M 10t / 100 t, drawing number 799523. The data plate is secured against removal by sealing or will be destroyed when removed. The data plate mentions at least the information and markings as described in the OIML R60 document. In the countries where it is mandatory the load cell should bear this test certificate number: TC2194. Securing: The connecting cable of the load cell or the junction box is provided with possibility to seal.

Appendix Page 4 of 4 Tests performed for this test certificate: Test Institute type, version, remarks Temperature test and repeatability (20, 40, -10 and 20 C) Temperature effect on minimum dead load output (20, 40, -10 and 20 C) CSP-M-25t-SC-C3.5-MB CSP-M-25t-SC-C3.5-MB Creep (20, 40 and 10 C) CSP-M-25t-SC-C3.5-MB Minimum dead load output return (20, 40 and 10 C) CSP-M-25t-SC-C3.5-MB Barometric pressure effects at room temperature CSP-M-25t-SC-C3.5-MB Humidity test CSP-M-25t-SC-C3.5-MB

Documentation folder Number TC2194-3 Page 1 of 1 Description Drawing number Rev. Remarks Load cell assembly CSP-M-40-EEx-C 7.882.005.0.635 0 Mechanical Outline Dimensions Special CSP-M 10t / 100 t 799523 - Mechanical Load cell Assy. type CSP 7.882.005.0.638 0 Electrical Specifications load cell CSP-M-..t-. HV-930217.079 -