Multi-Energy CT: Principles, Processing

Similar documents
Data Acquisition and Image Formation Methods for Multi Energy CT

Metal Artifact Reduction and Dose Efficiency Improvement on Photon Counting Detector CT using an Additional Tin Filter

Applications of Low KeV Imaging in Abdomen

Metal Artifact Reduction with DECT

Detector. * All clinical images are courtesy of. University, Jerusalem. Ami Altman, Ph.D., and Raz Carmi Ph.D., CT BU, PHILIPS Healthcare

X. Allen Li. Disclosure. DECT: What, how and Why Why dual-energy CT (DECT)? 7/30/2018. Improving delineation and response assessment using DECT in RT

Two-Material Decomposition From a Single CT Scan Using Statistical Image Reconstruction

DUAL ENERGY of the Pancreas

A practical approach to the introduction of spectral imaging into a large UK acute care teaching hospital

Abdominal DECT: How to Integrate Into Your Practice

Carlo N. De Cecco, MD, PhD

Potentials for Dual-energy kv/mv On-board Imaging and Therapeutic Applications

Nuclear Medicine Intro & Physics from Medical Imaging Signals and Systems, Chapter 7, by Prince and Links

CT-PET calibration : physical principles and operating procedures F.Bonutti. Faustino Bonutti Ph.D. Medical Physics, Udine University Hospital.

Part III Minor Option in Medical Physics 2018 Examples Sheet

Multi-energy CT: Future Directions. Acknowledgements. Overview 7/23/2014. Taly Gilat Schmidt, PhD. Kevin Zimmerman Franco Rupcich Steven Haworth

Electron density and effective atomic number images generated by dual energy imaging with a 320-detector CT system: A feasibility study

Introduction to SPECT & PET TBMI02 - Medical Image Analysis 2017

Differential Absorption Analysis of Nonmagnetic Material in the Phantom using Dual CT

PERFORMANCE EVALUATION OF MATERIAL DECOMPOSITION USING RAPID KVP-SWITCHING DUAL-ENERGY CT FOR ASSESSING BONE MINERAL DENSITY

Initial Certification

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah

11/19/2014. Chapter 3: Interaction of Radiation with Matter in Radiology and Nuclear Medicine. Nuclide Families. Family Nuclides with Same: Example

The relationship between image noise and spatial resolution of CT scanners

The physics of medical imaging US, CT, MRI. Prof. Peter Bogner

What is scintigraphy? The process of obtaining an image or series of sequential images of the distribution of a radionuclide in tissues, organs, or

Radionuclide Imaging MII Positron Emission Tomography (PET)

Technical University of Denmark

An experimental study of dual-energy CT imaging using synchrotron radiation

1. Which of the following statements is true about Bremsstrahlung and Characteristic Radiation?

Investigation of the relationship between linear attenuation coefficients and CT Hounsfield units using radionuclides for SPECT

Chapter 2 PET Imaging Basics

1-D Fourier Transform Pairs

Procesamiento de Imágenes y Bioseñales

Differentiating Chemical Reactions from Nuclear Reactions

ESTIMATION OF 90 SCATTERING COEFFICIENT IN THE SHIELDING CALCULATION OF DIAGNOSTIC X-RAY EQUIPMENT

Development of Radioactivity Standards for Quantitative Positron Emission Tomography

ELG7173 Topics in signal Processing II Computational Techniques in Medical Imaging

2015 Ph.D. Comprehensive Examination III. Radiological Sciences - Medical Physics

CLINICALLY USEFUL RADIONUCLIDES:

Introduction to Medical Imaging. Medical Imaging

Nuclear Radiation. Natural Radioactivity. A person working with radioisotopes wears protective clothing and gloves and stands behind a shield.

A. I, II, and III B. I C. I and II D. II and III E. I and III

Tomography is imaging by sections. 1

Rad T 290 Worksheet 2

HEAVY ion therapy is an advantageous modality over the

Quantitative Imaging with Y-90 Bremsstrahlung SPECT (Single Positron Emission Computed Tomography)

DEVIL PHYSICS THE BADDEST CLASS ON CAMPUS IB PHYSICS

Radioactive Decedents What is the risk?

ABSOLUTE AIR-KERMA MEASUREMENT IN A SYNCHROTRON LIGHT BEAM BY IONIZATION FREE-AIR CHAMBER

Positron Emission Tomography

Absorption spectra variations of EBT radiochromic film from radiation exposure

Medical Physics. Image Quality 1) Ho Kyung Kim. Pusan National University

Proposed Room Requirements for CT System

October 4th, Bioengineering 508: Physical Aspects of Medical Imaging Some Elementary Particles

Technical University of Denmark

List of Nuclear Medicine Radionuclides. Nuclear Medicine Imaging Systems: The Scintillation Camera. Crystal and light guide

11/10/2014. Chapter 1: Introduction to Medical Imaging. Projection (Transmission) vs. Emission Imaging. Emission Imaging

Research on the Method to Obtain Effective Energy in Materials Density Test Using X-ray CT

LECTURE 1: ELECTROMAGNETIC RADIATION

Lecture 5: Tomographic nuclear systems: SPECT

ANALYSIS OF THE GEOMETRICAL AND PHYSICAL FLUCTUATIONS WHILE PERFORMING INTRINSIC UNIFORMITY TEST FOR PHILIPS FORTE GAMMA CAMERA

Radioisotopes and PET

CHAPTER 5. Department of Medical Physics, University of the Free State, Bloemfontein, South Africa

Physics 210 Medical Physics Midterm Exam Winter 2015 February 13, 2015

Outline. Indrin J. Chetty, AAPM 2006 Monte Carlo CE course. Indrin J. Chetty Henry Ford Hospital. David W. O. Rogers Carleton University

Radiation Detectors. How do we detect ionizing radiation? What are these effects? Types of Ionizing Radiation Detectors

Radiation Detection and Measurement

Prompt gamma measurements for the verification of dose deposition in proton therapy. Contents. Two Proton Beam Facilities for Therapy and Research

CHAPTER 4 RADIATION ATTENUATION

Overview and Status of the Austrian Particle Therapy Facility MedAustron. Peter Urschütz

Reconstruction for Proton Computed Tomography: A Monte Carlo Study

Bases of radioisotope diagnostic methods

Research Article Evaluation of the X-Ray Absorption by Gold Nanoparticles Solutions

Physics in Nuclear Medicine

Acknowledgements. PET Fundamentals: Ideal Case. Why Are We Excited About PET/CT? PET Fundamentals: Real Case

MEASUREMENT OF DIAGNOSTIC X-RAY SPECTRA USING CdZnTe DETECTOR

The Nuclear Imaging Uncertainty Principle. Do Nuclear Cameras Really Work? Richard M. Fleming

Quality-Assurance Check of Collimator and Phantom- Scatter Factors

This is the last of our four introductory lectures. We still have some loose ends, and in today s lecture, we will try to tie up some of these loose

EFFECT OF SOURCE X-RAY ENERGY SPECTRA ON THE DETECTION OF FLUORESCENCE PHOTONS FROM GOLD NANOPARTICLES

Radionuclide Imaging MII Detection of Nuclear Emission

Evaluation of Phantom Equivalent Materials in Polychromatic Diagnostic X-Ray Beam

It is important. It is important. MTR: Imaging Clinical Trials. Isn t t it obvious? then why do we ask the question?

MRI of the airways and lungs Including hyperpolarized techniques

Fat to Muscle Ratio Measurements with Dual Energy X Ray Absorbtiometry

Physics of Novel Radiation Modalities Particles and Isotopes. Todd Pawlicki, Ph.D. UC San Diego

Mayneord-Phillips Summer School St Edmund Hall, University of Oxford July Proton decays to n, e +, ν

Expand the probe idea functionality (above points) to larger imaging systems. First Applications, Probes, Isotopes

Physics. Sunday, March 4, :30 a.m. 10:00 a.m.

Measurement of bone mineral in vivo: An improved method*

Bioimage Informatics. Lecture 23, Spring Emerging Applications: Molecular Imaging

Best MeV. Best , 25 MeV

6: Positron Emission Tomography

For the next several lectures, we will be looking at specific photon interactions with matter. In today s lecture, we begin with the photoelectric

Experimental validation of two dual-energy CT methods for proton therapy using heterogeneous tissue samples

Field trip: Tuesday, Feb 5th

BioE Exam 1 10/9/2018 Answer Sheet - Correct answer is A for all questions. 1. The sagittal plane

Number of protons. 2. What is the nuclear symbol for a radioactive isotope of copper with a mass number of 60? A) Cu

Renal perfusion measurement with Ultrasound Contrast Agents. Emilio Quaia. Department of Radiology University of Trieste

Transcription:

Multi-Energy CT: Principles, Processing and Clinical Applications Shuai Leng, PhD Associate Professor Department of Radiology Mayo Clinic, Rochester, MN Clinical Motivation CT number depends on x-ray attenuation Physical density (g/cm 3 ) [electron-density] Atomic number (Z) Different materials can have the same CT number if atomic number differences are offset by appropriate density differences 2 Technical Implementations of DECT Slow kvp Switching Inter-scan delay = scan time + table move time Fast kvp Switching Low kvp High kvp 1

Technical Implementations of DECT Dual Source Use twin beam filters Low kvp High kvp Technical Implementations of DECT X-rays X-rays Semiconductor detector directly converts x-ray to charge (e. g. CdTe) Read out lowenergy data Read out highenergy data Dual Layer Sandwich Detectors Photon Counting Detector C. McCollough, S Leng, L Yu, JG Fletcher. Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications. Radiology, 2015 DECT Image Type and Processing Algorithms 100 kv 140 kv Mixed 2

Material Differentiation Differentiate two different type of materials (no quantification) HU at 80 kv high Z low Z HU at 140 kv Iodine and Water Quantification Iodine Image Water Image 20 mg/cc Fused Image 8 Virtual Monoenergetic Images 50 kev 60 kev 70 kev 80 kev 100 kev 140 kev 9 3

Clinical Applications Renal stone differentiation Bone/Plaque removal in CTA Virtual noncontrast (VNC) image from contrast scans Bone bruise (VNCa) Lung perfusion Cardiac perfusion (blood pool) Gout detection and quantification Tumor treatment response assessment Renal Stone Differentiation UA UA CYS APA COX/BRU/STR APA Qu et al, AJR, 2011 Material Differentiation - Gout Glazebrook et al, Radiology, 2011 4

Material Differentiation - Gout All accurate assessment of disease burden to monitoring treatment effectiveness April December 90% reduction in volume of uric acid crystals over 8 months after receiving multiple infusions of rasburicase. Bone Removal Material characterization: Dual energy CT with bone subtraction Courtesy Terri Vrtiska, MD AP images Routine volume rendered 3D images obscured the stenosis (left) The high grade stenosis is easily depicted with DECT subtraction (right) 5

Virtual non-contrast (VNC) Contrast enhanced mixed (DE) image VNC image True non-contrast image 16 Lung perfusion Normal: homogeneous iodine map Patient with deep venous thrombosis developing severe dyspnea. Massive PE with occlusion of the right pulmonary artery. DE perfusion map shows an extensive perfusion defect in the right lower lobe Thieme et al, Seminar in Ultrasound, CT and MRI, 2010 DE Cardiac ccta shows subtotal occlusion (arrows) w/ calcified plaque I 2 map SPECT Ruzsics et al, Dual-energy CT of the heart for diagnosing coronary artery stenosis and myocardial ischemia-initial experience. Eur Rad. 2008 6

Virtual non-calcium Image SECT DECT - VNCa MRI S. Ai et al, Use of dual-energy CT and virtual non-calcium techniques to evaluate posttraumatic bone bruises in knees in the subacute setting. Skeletal Radiology; 2014 19 Monoenergetic Image 40 kev 85 kev 120 kev 140 kev (narrower window setting) Image window was adjusted individually. Silva et al, Radiographics 2011 Metal Artifacts Reduction Standard Image Monoenergetic Image (105 kev) 7

Dual Energy in Oncology Iodine Maps - Characterization Iodine Color Map late arterial phase VNC late arterial phase Courtesy of Dr. Joel G. Fletcher Dual Energy in Oncology Iodine Quantitation & Response to Rx Courtesy of Dr. Joel G. Fletcher Iodine Quantification 2 nd Generation DSDE 80/Sn140 kv a b c 100/Sn140 kv d f Scanner Model g DE Mode 25 cm 30 cm 35 cm 40 cm 45 cm All Sizes 80/Sn140kV 0.4 0.3 0.4 0.8 1.7 0.7 2 nd Gen. DS 100/Sn140kV 0.3 0.3 0.3 0.5 0.5 0.4 Leng et al, Phys. Med. Bio., In Press 8

Iodine Quantification 3 rd Generation DSDE 70/Sn150 80/Sn150 90/Sn150 100/Sn150 Leng et al, Phys. Med. Bio., In Press Energy Selective Images CT data acquisition: Polyenergetic beam CT number represents effective attenuation Virtual monoenergetic (monochromatic) images (VMI): mimicking image acquired with a monoenergetic beam CT number: attenuation at a certain kev. VMI CT Number Accuracy Leng et al, Phys. Med. Bio., In Press 9

30 cm 8/2/2017 CT number stability Across scanner models and phantom sizes VMI CT numbers for 10 mgi/cc at 60 kev CV 0.036 0.038 0.013 0.042 0.032 0.022 0.016 28 Iodine Quantification and CMI CT Number Accuracy Philips iqon scanner Courtesy of Dr. Xinhui Duan, UT South Western Iodine Quantification Error in iodine measurement generally within 10% across vendors (horizontal lines) Split-filter system within 10% of nominal value post-calibration Jacobsen, et al. Inter-manufacturer Comparison of Dual-Energy Computed Tomography Iodine Quantification and Monochromatic Attenuation: A Phantom Study. Radiology. Accepted pending revisions. July 2017. 40 cm Effect of Calibration on Split- Filter System: Nominal Default Calibrate Iodine Concentrati on Settings [mg/ml ] d Settings [mg/ml] 2 mg/ml 1.3 ± 0.2 2.0 ± 0.2 5 mg/ml 4.6 ± 0.2 5.4 ± 0.2 15 mg/ml 13.5 ± 0.2 14.2 ± 0.2 Courtesy of Dr. Dianna Cody 10

Radiation Dose Dual-energy scans don t need to increase dose Dose distributed between low/high energy acquisitions, each has a fraction of the total dose Mixed images use all photons (dose) 100 kv 140 kv Mixed Single Energy (120 kv) March 2009 CTDIvol: 18.65 mgy Indication: HCC 35 36 cm lateral width Dual Energy Mixed April 2009 CTDIvol: 15.59 mgy Radiation Dose Dual-energy scans don t need to increase dose Dose distributed between low/high energy acquisitions Mixed images VMI Energy domain noise reduction 50 kev 70 kev 100 kev 11

Energy Domain Noise Reduction 50 kev 60 kev Original HYPR-LR Leng et al, Med. Phys. 2011 Leng et al, Radiology, 2015 Energy Domain Noise Reduction DECT VMI SECT Leng et al, Med. Phys. 2011 Leng et al, Radiology, 2015 Summary Multiple technical approaches have been implemented to perform DECT Different types of images can be generated by DECT Low/high/mixed images Material specific images Energy selective images (VMI) Wide range of clinical applications Considerations in clinical trial Accurate iodine quantification Accurate and stable VMI CT number Radiation dose comparable to SECT Impact of patient side on DE mode selection 12

37 13