Further Developments on a Vibration-Free Helium-Hydrogen Sorption Cooler

Similar documents
14.5 K Hydrogen Sorption Cooler: Design and Breadboard Tests

Document Version Publisher s PDF, also known as Version of Record (includes final page, issue and volume numbers)

Flight Acceptance Testing of the Two JPL Planck Sorption Coolers

System design of 60K Stirling-type co-axial pulse tube coolers for HTS RF filters

Progress in the Development of the IXO 50 mk Sorption-ADR stage

Microscopy Cryostat System

Modification In Charging Composition In Order To Arrive At Desired Circulation Composition In The Context Of Sorption Compressor Based J-T Cooler

Cooling Temperatures of Binary Mixed Refrigerants: Vapor-Liquid-Liquid Equilibrium versus Vapor-Liquid Equilibrium

Development of a 4K Pulse-Tube Cold Finger for Space Applications

Vacuum techniques (down to 1 K)

Space Cryogenics at the Rutherford Appleton Laboratory

Vacuum. Residual pressure can thwart the best cryogenic design. Each gas molecule collision carries ~kt from the hot exterior to the cold interior.

KOH ACTIVATED CARBONS FOR SUPERCAPACITORS

ION Pumps for UHV Systems, Synchrotrons & Particle Accelerators. Mauro Audi, Academic, Government & Research Marketing Manager

CEA Saclay Seminar. Cryogenic Research for HTS Transmission Cables in Korea

Performance Testing of the Astro-H Flight Model 3-stage ADR

High-Pressure Volumetric Analyzer

Cryocoolers (CryoCoolers.tex)

Chapter: Heat and States

Report Liquid Hydrogen Target for the COMPASS Experiment

Vacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular

Cryogenic Technology for CMB-Pol: Passive Cooling and Stored Cryogen Systems

Chapter 16 Temperature and Heat

Adsorption isotherms and Sips models of nitrogen, methane, ethane, and propane on commercial activated carbons and polyvinylidene chloride

ADVANCED MODELLING TECHNIQUES for AEROSPACE SMEs

A cryogenic heat exchanger with bypass and throttling and its thermodynamic analysis

Available online at ScienceDirect. Physics Procedia 67 (2015 ) Superfluid helium heat pipe. P.

Composition Shift of a Mixed-Gas Joule-Thomson Refrigerator Driven by an Oil-Free Compressor

CapaciTorr HV 200 HIGHLIGHTS

1 Diversity of Carbon Pore Structures Obtained by KOH Activation. J. Z. Jagiello*, F. S. Baker, and E. D. Tolles

Experimental Investigation of Hybrid System Pulse Tube and Active Magnetic Regenerator

Physics Nov Cooling by Expansion

Chapter 1 Heating Processes

Vacuum System of Synchrotron radiation sources

Proton Conductive Membrane Compressor-Driven Pulse Tube Cryocooler

REFERENCE : DATE : 23/03/07 ISSUE : 01 Page : 1/23

CapaciTorr HV Pumps. making innovation happen,together

Experimental Investigation on a Single-Stage Stirling-Type Pulse Tube Cryocooler Working below 30 K

Performance and Mass vs. Operating Temperature for Pulse Tube and Stirling Cryocoolers

ScienceDirect. Space cryocooler developments

A Numerical Model of Regenerator Based on Lagrange Description

HEAT HISTORY. D. Whitehall

After successfully completing this laboratory assignment, including the assigned reading, the lab

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

Steven W. Van Sciver. Helium Cryogenics. Second Edition. 4) Springer

Earlier Topics. Introduction to Cryogenic Engineering An introductory knowledge of Cryogenic Engineering.

(Refer Slide Time: 00:00:43 min) Welcome back in the last few lectures we discussed compression refrigeration systems.

REFRIGERA TION OPTIONS FOR THE ADVANCED LIGHT SOURCE SUPERB END DIPOLE MAGNETS

A pulse tube refrigerator below 2 K

THE FIRST LAW APPLIED TO STEADY FLOW PROCESSES

NEXTorr HV 100 HIGHLIGHTS

Thermoacoustic Expansion Valve: A New Type of Expander to Enhance Performance of Recuperative Cryocooler Systems

1. ADR General Description

4.1. Physics Module Form 4 Chapter 4 - Heat GCKL UNDERSTANDING THERMAL EQUILIBRIUM. What is thermal equilibrium?

The Kinetic Theory of Matter. Temperature. Temperature. Temperature. Temperature. Chapter 6 HEAT

Cryogenic characterization of the Planck sorption cooler system flight model

BUILDING LOW-COST NANO-SATELLITES: THE IMPORTANCE OF A PROPER ENVIRONMENTAL TESTS CAMPAIGN. Jose Sergio Almeida INPE (Brazil)

4.1. Physics Module Form 4 Chapter 4 - Heat GCKL UNDERSTANDING THERMAL EQUILIBRIUM. What is thermal equilibrium?

Vacuum. Kai Schwarzwälder, Institut für Physik Universität Basel October 6 th 2006

Complex Compounds Background of Complex Compound Technology

Defining quality standards for the analysis of solid samples

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

PAPER 2 THEORY QUESTIONS

Vacuum Solutions for Ion Thruster Testing

3 Types of Heat Transfer

SOPHISTICATED DESIGN, INTUITIVE OPERATION, RESEARCH-GRADE RESULTS

Venus Atmosphere Platform Options Reconsidered

Russell B. Schweickart and Gary Mills

Baffle Telescope Tube. Bus Module Bus MLI

The Vacuum Case for KATRIN

arxiv: v2 [astro-ph.im] 23 Jul 2018

Conceptual Physics Fundamentals

Magnetic Property Measurement System

file:///biology Exploring Life/BiologyExploringLife04/

Development of high-efficiency Stirling cryocoolers for high temperature superconducting motors

Development Status of 50 mk Hybrid Coolers for Space Applications at CEA-SBT

PREFERRED RELIABILITY PRACTICES. Practice:

Handout 10: Heat and heat transfer. Heat capacity

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

A thermodynamic system is taken from an initial state X along the path XYZX as shown in the PV-diagram.

Experiment 1. Measurement of Thermal Conductivity of a Metal (Brass) Bar

Electricity and Energy 1 Content Statements

SPACE CRYOGENICS AT CEA-SBT

6-3 Particle model of matter Trilogy

Yeon Suk Choi \ Steven W. Van Sciver \ and Ho-Myung Chang u

Development of a Mechanically Pumped Two-Phase CO 2 Loop for the AMS-2 Tracker Thermal Control System

KS3 Science. Heat and Energy

Status of the GERDA experiment

Chapter 16 Temperature and Heat

4.3 Planck. Scientific goals. Planck payload

Development of a Compressor for a Miniature Pulse Tube Cryocooler of 2.5 W at 65 K

CFD Modeling of Tilt Induced Cooling Losses in Inertance Tube Pulse Tube Cryocoolers

Cleaning Electronegative Contamination from Gaseous Xenon Through Cryogenic Pumping

An Investigation on NEG Thick Film for Vacuum packaging of MEMS

Design of a Refrigerator. Department of Aerospace and Mechanical Engineering. Abdallah Soliman. Masih Ahmed. Ryan Seballos. EMAE 355 Project 4

Theoretical Analysis and Optimization of Regenerator of Stirling Cryocooler

Low Vibration Cryogenic Equipment

CUORE Detector Calibration System

NUMERICAL ANALYSIS OF DOUBLE INLET PULSE TUBE REFRIGERATOR. Samarendra Panda Roll No.: 213ME5452

MATTER AND HEAT. Chapter 4 OUTLINE GOALS

Transcription:

Further Developments on a Vibration-Free Helium-Hydrogen Sorption Cooler J.F. Burger1, H.J. Holland1, R.J. Meijer1, H.J.M. ter Brake1, J. Doornink2, A. Sirbi3, M. Linder3 1 University of Twente, Faculty of Science and Technology, 7500 AE Enschede, The Netherlands 2 Dutch Space, The Netherlands; 3 ESA-ESTEC, The Netherlands ABSTRACT In our continuous effort on the development of a passively precooled two-stage 4.5 K / 14.5 K helium-hydrogen sorption cooler, a number of important development steps were made. Firstly, an improved high-density activated carbon was used for the fabrication of four new sorption cells. Tests with these new cells showed that because of increased efficiency, the required passive radiator area for this cooler reduced by a factor of 1.3. Secondly, it was shown that this cooler architecture can easily be used to reach lower (or higher) temperatures. Without hardware changes, the cold temperature was reduced from 4.5 K to 3.1 K. Thirdly, long-term experiments were carried out on the cooler. In two separate periods of two and four months of continuous operation, no change at all was observed in the cooler performance. Fourthly, clogging effects were analyzed that occurred after a 15 months storage period of the cooler at 300 K. We concluded that hydrogen diffusion out of the stainless steel components should be prevented. Finally, a design of an integrated compact cooler chain was presented, which consists of a 50 K Stirling cooler and the helium-hydrogen sorption cooler. This package may be used in the future to test the sorption cooler technology in a zero-gravity environment. INTRODUCTION The University of Twente is working in a continuous effort on the development of a passively precooled two-stage 4.5 K / 14.5 K helium-hydrogen sorption cooler. This cooler has no moving parts and is, therefore, essentially vibration-free. It is a favorite option for space missions such as ESA's Darwin and Xeus missions, which require long-life and vibration-free cooling to low temperatures.1 The selected cooler design consists of a hydrogen stage cooling from 80 K to 14.5 K and a helium stage establishing 5 mw at 4.5 K, see Fig. 1.2 Both stages use micro-porous activated carbon as the adsorption material. The two cooler stages need only a few Watts of input power and will be heat sunk on two passive radiators at temperatures of about 50 K and 80 K, radiators which should be constructed at the cold side of the spacecraft. We have developed and built a demonstrator of the helium stage under an ESA-TRP contract. The design of this cooler, together with detailed experiments, was presented previously at the ICC in 2006.3 23

24 Space cryocoolers for 4-20 K applications 80 K H2/ carbon 16.5 bar 50 K, 1.07 W A = 4.2 m2 50-120 K 4 bar He/ carbon 50 K pi 47 K, 0.89 W A = 3.7 m2 47-80 K 1.3 bar to H2-stage pl 5.7 mw flow = 0.41 mg/s 14.5 K few mw s from shield 4.5 K 14.5 K shield 4.5 K, 5 mw Figure 1. (a) Schematic picture of the proposed helium / hydrogen sorption cooler, which is precooled by two passive radiators at about 50 K and 80 K. (b) More detailed design of the helium sorption cooler. Since then, we have monitored a number of aspects that may affect the long-term operation of this cooler. These aspects will be discussed in this paper. Furthermore, we have replaced the four sorption cells with new cells that contain a new high-density activated carbon, which results in an efficiency improvement by a factor of about 1.3. Measurements with these new cells are presented. In addition, experiments are presented that illustrate the ability of this cooler to reduce the low temperature in a flexible way, to approximately 3 K. Finally, we will present the design of an integrated compact cooler chain that consists of a Thales 50 K Stirling cooler and the helium-hydrogen sorption cooler. For general details about the operation of sorption coolers, the reader is referred to the literature.4, 5 TESTS WITH IMPROVED SORPTION CELLS A passively precooled sorption cooler for space applications has a number of clear advantages over alternative mechanical cooler options, such as no vibration, long or infinite lifetime, and a very low input power. The price to pay for these advantages is that a passive radiator is required. The activated carbon that is used in the compressor cells strongly influences the performance of the cooler, and hence the required radiator area. The carbon used so far was optimized especially for our application by the University of Alicante; it is a monolithic highly micro porous carbon of high density made from anthracite.6 From previous work5 we knew that activated carbons fabricated from synthetic precursors could result in even higher carbon densities (up to 1.1 g/ml), which would reduce the radiator area most likely. An important reason for this performance improvement is the very low void volume of such carbons. We were able to obtain this type of material and we built four new sorption cells with it. Apart from the new carbon, we tested a few fabrication improvements of the cells. The existing sorption cells in the cooler were replaced with the four new cells. In addition, a leaking check valve was replaced, which forced us in previous measurements to test the cooler with three instead of four operating sorption cells.2 After replacement of the sorption cells and the check valve, the cooler was cleaned and re-filled with high-purity helium gas. After cool-down of the system to 50 K using a GM cryocooler, the sorption cooler was started; it cooled down successfully to 4.5 K. Next, important operating parameters such as the compressor low and high temperature and the intermediate pressure were varied to find the optimum operating parameters (i.e. minimum radiator area). A typical measurement of the system cooling to 3.15 K is given in Fig. 2. Table 1 compares the resulting performance numbers of the cooler for the previous and present activated carbon. Clearly, a reduction of a factor of 1.3 is obtained for the resulting radiator area.

25 DeveloPmenT of vibration-free He-H2 SorPTion Cooler Figure 2. Typical measurement of the helium sorption cooler, operating with a low pressure of 0.27 bar and a (very stable) cold temperature of 3.15 K. From top to bottom: compressor and heat switch temperatures of the first stage compressor cells, compressor and heat switch temperatures of the second stage compressor cells, high, medium and low pressure, compressor input powers, cold temperature. VARIATION OF THE LOW TEMPERATURE The cold temperature is determined by the low pressure in the return line of the cold stage, which controls the boiling point of the evaporator. For a low temperature of 4.5 K, the low pressure is about 1.3 bar. In principle, this pressure can be lowered by filling the sorption cooler with less gas so that during operation a lower pressure is present in the low pressure buffer. The low pressure can be reduced as long as no significant pressure drops arise in the low pressure lines, and as long as the first compressor stage is able to pump sufficiently on the low pressure line (for a certain heat sinking temperature the sorption pumping capacity reduces with a Table 1. Comparison of the resulting performance numbers of the sorption compressors. 1st stage compressor sink temperature cycle period average input power in compressor stage resulting radiator area (assuming emissivity = 0.8) 2nd stage compressor sink temperature cycle period average input power in compressor stage resulting radiator area (assuming emissivity = 0.8) combined 1st and 2nd stage compressor average input power resulting radiator area (assuming emissivity = 0.8) test results previous carbon test results new carbon 47.1 289 s (single cell) 0.89 W 4.2 m2 50 K 600 s (two cells) 0.88 W 3.1 m2 50.5 K 975 s 1.07 W 3.7 m2 52 K 1436 s 0.99 W 3.05 m2 1.96 W 7.9 m2 1.85 W 6.2 m2

26 Space cryocoolers for 4-20 K applications Table 2. list of the experimental results in which the temperature is reduced in steps from 4.5 K to 3.1 K. p low (bar) 1.27 0.78 0.47 0.27 0.23 p middle (bar) 4.6 4 2.63 1.45 1.5 T cold (K) 4.5 4 3.55 3.15 3.1 P cold (mw) 4.5 4.6 4.7 5 4 TL1 (K) 50 48 48 45 45 TL2 (K) 52 52 50 45 45 P in (W) 1.85 2.29 2.94 3.15 2.75 Area (m2 ) 6.2 8.5 11.7 17.7 15.4 Area/Pcold (m2 /mw) 1.38 1.85 2.49 3.54 3.85 Radiator area per m W of cooling power (m2 /m W ) reduction of the low pressure, resulting in a faster cycling of the cells). We decided to demonstrate experimentally to what level the low temperature can be reduced. Apart from a reduction of the amount of He gas in the system and an adaption of the control settings in the software, no other hardware changes were made. Table 2 shows a list of the experimental results in which the temperature is reduced in steps from 4.5 K to 3.1 K. A temperature of 3.1 K was the lowest value that could be reached with the present set-up; at this temperature the first compressor stage was just able to maintain the low pressure of 0.23 bar. With minor modifications in the set-up, a temperature as low as 2.5 K can be achieved with 4He. (see the discussion below). Fig. 3 shows a plot of the specific radiator area that is derived from the measured cooler performance, which is compared to previously modelled values. The difference between the measured and modelled values increases for lower temperatures, which we can explain due to two different effects. Firstly, at 4.5 K the cooler operating parameters were optimized experimentally to obtain a minimum radiator area (i.e. the cooler control settings were varied to find the best performance). This optimization was not carried out for the lower temperatures and, therefore, the resulting radiator area is not optimized. This sub-optimal operation will be stronger for lower cold temperatures. Secondly, for lower temperatures the first compressor stage performance is deteriorating due to internal pressure drops, an effect which especially occurred when reducing the low temperature from 3.15 K to 3.1 K. Such low temperatures (and even lower temperatures down to 2.5 K) could be reached without a performance reduction if a lower mass flow could be selected (by replacing the flow restriction) or by adding one or more sorption cells in the first stage compressor. From the results it can be concluded that the sorption cooler technology is very suitable for reaching lower (or higher) cooling temperatures with the same cooler architecture. 4.50 4.00 3.50 3.00 2.50 measured 2.00 modelled 1.50 1.00 0.50 0.00 2.8 3 3.2 3.4 3.6 3.8 4 4.2 4.4 4.6 T cold (K) Figure 3. Plot of the specific radiator area as a function of the cold temperature of the cooler.

DeveloPmenT of vibration-free He-H2 SorPTion Cooler 27 LONG TERM OPERATION OF THE SORPTION COOLER After the initial tests on the sorption cooler which were described previously2, a number of steps were made with the cooler that provide information about various aspects of the long term operation of the sorption cooler. In a period of two years, the following steps were made: 1. After the initial cooler tests2, the cooler was left running for a period of two months. 2. The sorption cooler and the precooling GM cooler were switched off for a period of about 15 months, leaving the sorption cooler unchanged at 300 K in our lab. 3. When the new sorption cells were ready to replace the old cells, we first wanted to check if the sorption cooler with the old cells would still restart properly after the 15 months of storage at 300 K. 4. After this restarting test, the old sorption cells were replaced with the new cells and the tests were carried out that were described in the previous sections. 5. After these tests, the sorption cooler was left running for a period of 4 months (until the day of writing this paper). During the two and four months of continuous cooler operation (steps 1 and 4 above), we did not observe any change in the cooler performance whatsoever. This also means that we did not observe any change or degradation of the activated carbon, the check valves, or the gas-gap heat switches. Also, clogging of the cold stage did not occur during normal continuous operation of the cooler. However, after restarting the sorption cooler after 15 months of storage (see step 3 above), significant clogging problems of the cold stage occurred; stable cooling at 4.5 K with the full cooling power could not be obtained anymore. These problems are discussed in more detail in the next section. ANALYSIS OF CLOGGING EFFECTS In the initial measurements before the 15 months storage period, clogging was only once observed in a special situation. The cooler had operated at 4.5 K without any clogging for about 10 days, when we deliberately and rapidly heated the coldest part of the counterflow heat exchanger from around 5 K to 15 K (while the JT and evaporator were still at 4.5 K!). After this (very local) heating action, suddenly clogging of the JT restriction occurred; it appeared later that the flow had reduced to approximately 25% of its original value. We analyzed the situation and expected that small amounts of frozen hydrogen in the coldest parts of the counterflow heat exchanger were evaporated due to the local heating action, and transferred to the JT restriction that was still at 4.5 K. Here it could freeze again and block the narrow pores of the JT plug. After stabilization of the system in which the cooling and input powers had dropped to 25% of their original values, the system was left in this condition for one night. A gradual increase in the cooling power could be observed (from 1.15 mw to 1.6 mw in 20 hours), indicating a movement of the contamination out of the JT restriction. Then, the restriction was manually heated to 14.5 K for about one hour. After this step, the cooling power returned to the original 4.5 mw at 4.5 K: the contamination was apparently evaporated from the JT. The fact that a temperature of 14.5 K was sufficient to clean the flow restriction confirms the idea that hydrogen was the contaminating gas (the triple point of hydrogen is 13.8 K). This experiment shows that small amounts of contaminant gases can be frozen and maintained inside the cold counterflow heat exchangers, thereby not harming the cooling power as long as the contaminants do not move into the JT flow restriction. Since then, the 4 K sorption cooler was stored in our lab for 15 months at 300 K with the original batch of helium inside. After these 15 months, the GM precooler was restarted to cool the sorption compressors to 50 K. After starting of the sorption compressors, it appeared that we could not successfully reach 4.5 K with 4.5 mw of cooling power anymore. Either the system clogged completely after cooling below 13 K, or it clogged initially partially at 4.5 K and later

28 Space cryocoolers for 4-20 K applications completely. We then tried to measure the hydrogen concentration in the helium gas of the sorption cooler using a mass spectrometer, calibrated for low concentrations of hydrogen in helium gas. We measured a hydrogen concentration on the order of 40 ppm. We estimated the original concentration of hydrogen in the system at 0.1 ppm; this is based on the 6.0 purity helium gas that was used to fill the system. Apparently, a hydrogen concentration increase from 0.1 to 40 ppm is sufficient to move from clogging-free operation to a situation of problematic clogging. This hydrogen concentration increase can most likely be explained by hydrogen diffusion out of the metal elements of the cooler while it was stored at 300 K; such diffusion will not occur if the cooler is operating at 50 K (hydrogen diffusion is strongly dependent on the temperature and is much less at cryogenic temperatures). To prevent outgassing of hydrogen out of the metal elements of the cooler during storage of the cooler at 300 K, a careful bake-out procedure should be applied to these elements prior to use. A similar procedure can be applied that is also used to bake-out UHV components. We expect that this is sufficient to prevent hydrogen outgassing. As an alternative measure, hydrogen gettering in the buffers may be applied. DESIGN OF A COMPACT STIRLING SORPTION COOLER CHAIN A passively precooled sorption cooler is a favorite option for future space missions that require long-life and completely vibration-free cooling to low temperatures. Examples of such missions are ESA's Darwin and Xeus missions. ESA has indicated that early tests in a space environment are desired, to gain experience and reduce the risks of using this new cryocooler technology in an expensive mission. In a small project funded by ESA, we made a conceptual design of a cooler chain consisting of a Stirling precooler plus the helium-hydrogen sorption coolers. This compact system might be used for tests on the International Space Station or in another small space mission to study the effect of the zero-g environment on the cooler behaviour, in particular on two-phase flow and evaporation effects in the cold stage. Fig. 4 shows a schematic lay-out of the cooler chain. The Stirling cooler replaces the large passive precooling radiator that is required for complete vibration-free cooling. We proposed to 50 K platform with sorption cells and buffers helium-stage hydrogen-stage ph Stirling cooler, 3.8 W at 50 K Thales Cryogenics LSF 9330 (developed for ISS Cryosystem) pi pl 14.5 K 15 mw pl 5.7 mw 4.5 K, 5 mw cold stage enclosure 14.5 K shield 50 K radiation shield with MLI isolation hermetically sealed vacuum chamber, with getter inside to maintain a proper vacuum Figure 4. Schematic lay-out of the compact Stirling helium/hydrogen sorption cooler chain.

29 DeveloPmenT of vibration-free He-H2 SorPTion Cooler sorption cells Stirling cooler (compr. + cold tip) hermetically welded aluminium bell-jar 50 K platform gas buffers cold stage (with 14.5 K & 4.5 K platforms) Figure 5. Conceptual drawing of the compact and light-weight aluminium bell jar with the sorption coolers inside, and the Stirling cooler connected from the outside through the collar to the 50 K platform. use the Thales LSF 9330 cooler, originally developed for cooling of Cryosystem on ISS. The Stirling cooler cools an aluminium platform at 50 K that contains the sorption cells of the helium and hydrogen sorption coolers. This sorption cooler architecture is slightly different from the original architecture, where the hydrogen sorption compressor is heat sunk at 80 100 K. In combination with a mechanical cooler a simple configuration arises if the hydrogen sorption compressor is heat sunk at 50 K, together with the helium cells. In this case, one small sorption cell can drive the miniature hydrogen cold stage. The hydrogen cold stage elements below 50 K (which would be an important study item in such a test) remain identical as compared to the originally proposed configuration for Darwin. Notice that in combination with passive precooling it is not attractive to run the hydrogen sorption cooler from 50 K: this would significantly increase the required radiator area! Fig. 5 shows a conceptual drawing of the compact and light-weight aluminium bell jar; it was designed for tests in ESA s Columbus laboratory on ISS. The total mass, including electronics, would be approximately 20 kg. The compact cooler chain provides cooling at 50 K, 14.5 K and 4.5 K, which is available for cooling of small instruments in the (test) mission. CONCLUSIONS A number of new experimental and design steps were made in the continuous effort of the University of Twente to develop the passively precooled vibration-free 4.5 K / 14.5 K heliumhydrogen sorption cooler for space applications. Test results with a new high-density carbon show that the cooler efficiency is improved, which results in a reduction of the specific radiator area with a factor of 1.3. It was shown that the sorption cooler technology is very suitable for reaching lower (or higher) cooling temperatures than 4.5 K, using the same cooler architecture. Without any hardware change a cold end temperature of 3.1 K was reached. Long term experiments were carried out with the sorption cooler. During two periods of two and four months of continuous cooler operation, no change in the cooler performance was observed in more than 20000 compressor cycles that were made. During normal operation no problems with clogging of the JT were observed. However, after 15 months of storage at 300 K the cooler showed significant clogging problems.

30 Space cryocoolers for 4-20 K applications Hydrogen diffusion out of the stainless steel walls is the most likely cause of this problem. With proper bake-out procedures this can probably be prevented. The design of an integrated compact cooler chain was presented, which consists of a Thales 50 K Stirling cooler and the helium-hydrogen sorption cooler. The total package, including compact vacuum chamber and electronic controller, has a mass of less than 20 kg, requires less than 150 W input power, and may be used to test this cooler chain in space. In the period 2008 2010 we are working on the development of the hydrogen sorption cooler: system modelling and design, breadboarding and test activities on component level, and development of a full functioning breadboard model (aiming at TRL level 5). REFERENCES 1. Burger, J.F., ter Brake, H.J.M., Rogalla, H., Linder, M., Vibration-free 5 K sorption cooler for ESA s Darwin mission, Cryogenics, vol. 42 (2002), pp. 97-108. 2. Burger, J.F., ter Brake, H.J.M., Holland, H.J., Meijer, R.J., Veenstra, T.T., Venhorst, G.C.F., Lozano-Castello, D., Coesel, M., Sirbi, A., Long-life vibration-free 4.5 K sorption cooler for space applications, Review of Scientific Instruments, Vol. 78 (2007). 3. Burger, J.F., Holland, H.J., Meijer, R.J., Venhorst, G.C.F., Veenstra, T.T., ter Brake, H.J.M., Rogalla, H. Coesel, M., Lozano-Castello, D., Sirbi, A., Vibration-free 4.5 K sorption cooler, Cryocoolers 14, ICC Press, New York (2007), pp. 487-496. 4. Bowman Jr., R.C., Kiehl, B. and Marquardt, E., Closed-Cycle Joule -Thomson Cryocoolers, Spacecraft Thermal Control Handbook, Volume II: Cryogenics, edited by M. Donabedian, The Aerospace Press, El Segundo, CA (2003), pp. 187-216. 5. Burger, J.F., Holland, H.J., Wade, L.A., ter Brake, H.J.M., Rogalla, H., Thermodynamic considerations on a microminiature sorption cooler, Cryocoolers 10, Kluwer Academic / Plenum Press, New York (1999), pp. 553-564. 6. Lozano-Castello, D., Lillo-Rodenas, M.A., Cazorla-Amoros, D., Linares-Solano, A., Preparation of activated carbons from Spanish antracite I. Activation by KOH, Carbon, Vol. 39 (2001), pp. 741749.