Liquid Scintillation at NPL: Practical Applications

Similar documents
Validation of detection efficiency of alpha particles in commercial liquid scintillation counters

The TDCR method in LSC. P. Cassette Laboratoire National Henri Becquerel CEA/LNE, France

BUREAU INTERNATIONAL DES POIDS ET MESURES

Activity measurement of 55 Fe within the scope of the BIPM comparison 2006

Acoustics and Ionising Radiation Formulation and Strategy. 13 November 2008 Alan DuSautoy

Fundamentals of Radionuclide Metrology

Primary Standardization of 152 Eu by 4πβ(LS) γ (NaI) coincidence counting and CIEMAT-NIST method

19:00 21:30 Registration and reception at Hotel ETAP Altinel. Welcome

Čerenkov counting and liquid scintillation counting of 36 Cl

Summary of the ICRM Life Sciences Working Group Meeting

TDCR in a nutshell. P. Cassette, Laboratoire National Henri Becquerel, France

TECHNETIUM-99 IN WATER

RESULTS YOU CAN COUNT ON

Activity determination of 88 Y by means of 4πβ(LS)-γ coincidence counting

SECTION 8 Part I Typical Questions

Standardization of Tritium by CIEMAT/NIST Method and TDCR Method

Radioactivity standardization in South Africa

LIQUID SCINTILLATION COUNTERS. {Beta Counters}

LSUF Update on Organically Bound Tritium Standard project. Arvic Harms. 5 May 2004

SYRACUSE UNIVERSITY RADIATION PROTECTION PROGRAM APPLICATION FOR USE OF RADIOACTIVE MATERIALS

Gross Alpha-Gross Beta Analysis in Water by Liquid Scintillation Counting (LSC)

The measurement of tritium in environmental water samples

DISTRIBUTION LIST To be filled out by Document Author or person requesting document deletion

NPL REPORT IR 26. Environmental Radioactivity Proficiency Test Exercise 2010 ARVIC HARMS AND CHRIS GILLIGAN

5) Measurement of Nuclear Radiation (1)

Consistency and confidence: the role of the National Measurement System

RADIOLOGICAL CHARACTERIZATION Laboratory Procedures

Hidex LSCs. LSC 2013 Barcelona

GUIDE TO LABORATORY SURVEYS. Introduction

Acronyms, Abbreviations, and Symbols Foreword to the First Edition Foreword to the Second Edition Preface to the First Edition Preface to the Second

Energy Calibration of Liquid Scintillation Counter to allow Semi-Qualitative Nuclide Identification in Water Samples

Work Programme. of the International Bureau of Weights and Measures. for the four years Comité international des poids et mesures

Determination of H-3 and C-14 in the frame of decommissioning projects at the Paul Scherrer Institute

TECHNETIUM-99 IN SOIL

TDCR and CIEMAT/NIST Liquid Scintillation Methods applied to the Radionuclide Metrology

Accreditation of radiochemical analyses, from NAMAS to ISO 17025:2005 and beyond

Working Copy. P /ru /,6. 8-tt tt. EffectiveDate: I ^, Operation and Calibration of the Tri-Carb Liquid Sclntillation Counter QAM-RI.106.

Standardization of 18 F by Digital β(ls)-γ Coincidence Counting

COMPARATIVE STUDY BETWEEN EXTERNAL STANDARD METHOD AND INTERNAL STANDARD METHOD FOR LOW-LEVEL TRITIUM MEASUREMENTS

Ionizing Radiation Metrology at NMIJ/AIST and ENEA-INMRI

This document is a preview generated by EVS

COMBINED LSC-BASED METHOD FOR RADON IN AIR MEASUREMENTS

Recent Primary Standardisations and Traceability in Nuclear Medicine. Lena Johansson, NPL Radioactivity Group

Scintillation Proximity Assay on the TopCount Microplate Scintillation Counter

SEQUENTIAL DETERMINATION OF AMERICIUM, PLUTONIUM AND URANIUM IN LIQUID EFFLUENTS FROM NUCLEAR POWER PLANTS

1.1. This is a method for the separation and measurement of 228 Ra in water via its beta emitting 228 Ac daughter.

*Corresponding author,

Radiochemistry and Compliance Assessment of LLW The Waste Quality Checking Laboratory (WQCL) Chris Dale AMEC Nuclear UK Limited UKAEA Winfrith

Hidex 300 SL Automatic TDCR Liquid Scintillation Counter

Portable Radiation Survey Instruments

Unit 2. Instrumentation. Experts Teaching from Practical Experience

APPLICATION OF A FREE PARAMETER MODEL TO PLASTIC SCINTILLATION SAMPLES

SLAC Radioanalysis Laboratory

Application Note. Abstract. Introduction. Experimental

The detector and counter are used in an experiment to show that a radioactive source gives out alpha and beta radiation only.

The metrology of radioactivity. C. Michotte, BIPM

ISO Water quality Determination of carbon 14 activity Liquid scintillation counting method

APPLICATION FOR AUTHORIZATION

C2-05: Creation of national standards for some emerging pharmaceutical radionuclides to ensure the radioprotection of patients and medical staffs

UNCORRECTED PROOF. Table of Contents

Plastic Scintillation and dryness evaporation: a new procedure for Alpha/Beta determination in water samples

Nuclear Engineering Seibersdorf GmbH

Revision checklist. Step Learning outcome Had a look Nearly there Nailed it!

INSTRUMENTAL NEUTRON ACTIVATION ANALYSIS (INAA)

Revised material in Section 4, Analytical Chemistry

Primary Standardisation of I-125

LSC for Quality Control of 99m TC Eluate from 99 Mo- 99m Tc Generator

CCRI(II) activity comparison of 241 Pu CCRI(II)-K2.Pu-241

DETERMINATION OF BETA EMITTERS IN MATERIALS FROM RESEARCH REACTOR DECOMISSIONING

Liquid Scintillation Measurement Assurance Improvements for Tritium Counting (U)

Refresher Radiation Safety Training Scott Jaqua, RSO

Michael G. Stabin. Radiation Protection and Dosimetry. An Introduction to Health Physics. 4) Springer

Derivation of Calibration Factors and Dial Settings Michaela Baker

Part 1: Water quality Radium-226. Test method using liquid scintillation counting

IMPROVED TECHNIQUES FOR THE ACTIVITY STANDARDIZATION OF 109 Cd BY MEANS OF LIQUID SCINTILLATION SPECTROMETRY

TECHNETIUM-99 IN WATER

Applied Nuclear Science Educational, Training & Simulation Systems

1220 QUANTULUS The Ultra Low Level Liquid Scintillation Spectrometer

Reference Materials for Trade and Development: Quality and Comparability

Nuclear Chemistry. Nuclear Terminology

The sources include Am-241 which emits alpha radiation, Sr-90 which emits beta radiation and Co-60 which emits gamma radiation.

4.4 Atomic structure Notes

Depth Distribution of H-3, C-14 and Co-60 in Decommissioning of the Biological Shielding Concrete of KRR-2

Analyzing Radiation. Pre-Lab Exercise Type of Radiation Alpha Particle Beta Particle Gamma Ray. Mass (amu) 4 1/2000 0

Michigan Small Animal Imaging Resource Center for Molecular Imaging. Department of Radiology. University of Michigan

Basics of a/b Discrimination for Liquid Scintillation Counting

Core Questions Physics unit 4 - Atomic Structure

DETERMINING FUNDAMENTAL PARAMETERS OF A SINGLE-PHOTOTUBE LIQUID SCINTILLATION COUNTER

The UK Tritium Users' Group

Activities of the neutron standardization. at the Korea Research Institute of Standards and Science (KRISS)

Page 2. Draw one line from each type of radiation to what the radiation consists of. Type of radiation. What radiation consists of

There are no stable isotopes of elements above atomic number 83.

12/18/2016. Radioanalysis Laboratory Capabilities and Issues. Eleventh Annual Radiation Measurement Cross Calibration Workshop RMCC XI

Mohamed BEN ABDALLAH

Radiation Safety In-Service House-Keeping and Security Departments. Petrone Associates LLC Specialists in Applied Medical Physics

LSC-BASED APPROACH FOR RADON IN SOIL GAS MEASUREMENTS. The Marzeev Institute of Hygiene and Medical Ecology 50, Popudrenko str., Kiev 02094, Ukraine.

2100TR Liquid Scintillation Counter

ISO INTERNATIONAL STANDARD. Measurement of radioactivity in the environment Soil Part 5: Measurement of strontium 90

NICKEL-63/59 IN WATER

NEW DEVELOPMENTS OF AUTORADIOGRAPHY TECHNIQUE TO IMPROVE ALPHA AND BETA MEASUREMENTS FOR DECOMMISSIONING FACILITIES

Transcription:

2003 LS User s Forum Liquid Scintillation at NPL: Practical Applications Andy Pearce CAIR, NPL 2 nd April 2003

Introduction Overview of applications Current projects Neutron-activated thioacetamide discs Impurity assay for 32 P comparison

Primary Standards & Development Customer & Secondary Standards Health Physics TDCR 4πβ-γ LS Adsorption tests 3 H assay Alpha assay Pure beta Dilution checks 3 H screening Swabs Waste assay Radiochemistry CIEMAT / NIST

Primary Standards & Development Funded by DTI: Assay of 32 P, 90 Y, 192 Ir, 204 Tl for international comparisons Enhancement of TDCR system Etension of CIEMAT/NIST technique Organically Bound Tritium (OBT)

Primary Standards & Development Other maintenance/development work: HSE 3 H in water audit NPL environmental level comparison 2002 & 2003 Development of new environmental level standards Radon in water rig

Secondary Standards & Customer Many projects/services involving LSC, for eample: Environmental level radioactivity standards Non-gamma emitting radioactivity standards 32 P in neutron-activated Thioacetamide discs

Impurities in 32 P by Liquid Scintillation In 2002, NPL participated in the International Comparison of 32 P activity organised under Bureau International des Poids et Mesures (BIPM) 32 P is used to bind to molecules such as ATP (involved in cellular respiration) for MR spectroscopy However

Impurities in 32 P by Liquid Scintillation 32 P is produced by neutron irradiation of Sulphur 33 P & 35 S also produced in trace amounts the half life of 32 P is shorter than the impurities if the solution is old, the contaminants become increasingly significant

Impurities in 32 P by Liquid Scintillation To determine activity of 32 P accurately, the ratio of the contaminants must first be quantified A series of 63 measurements taken on two LS vials containing samples of the solution were assayed over a 2-3 month period Knowledge of the half lives enables the impurity to be determined by a linear least squares technique

Impurities in 32 P by Liquid Scintillation The count rate in the samples is given by: The best fit is found by minimising: 3 3 3 2 2 2 1 1 1 3 2 1 3 2 1 ),, ( ; ; 3 2 1 A A A N e e e t t t ε ε ε λ λ λ + + = = = = = i i i i i i N N 2 3, 2, 1, 2 ),, ( σ χ

Estimate of Activities in 32 P Fitted values for 32 P, 33 P, 35 S Estimated Activities/Bq 10 5 8 7 6 5 4 3 2 10 4 8 7 6 5 4 3 Counts Least Squares Fit P-32 P-33 S-35 2 10 3 0 10 20 30 40 50 time/days

Impurities in 32 P by Liquid Scintillation Some comments: By comparing χ 2 for models with and without 35 S, can determine if 35 S is really present (we re pretty sure it is) Samples have to be stable over the measurement period. We re dealing with 0.1 g aqueous solution in 10 ml (get the scintillant), and the results seem OK The model fits the data very well and the type A uncertainties are low at around 0.1 %

Neutron-Activated Thioacetamide Discs Neutron accident dosimeters (neutron belts) contain sulphur discs which become activated on eposure to large neutron flues These discs are assayed via a calibrated GM counter to determine activity and hence received dose NPL provides a service to a particular customer of calibrating the 32 P content of the sulphur discs

Neutron-Activated Thioacetamide Discs Problem 1: Getting large sulphur samples into a scintillation cocktail can be hazardous for your Radiochemist s health Solution: Thioacetamide and Sulphur tablets are irradiated in the same neutron beam. A relative measurement is made of all tablets using a proportional counter and the Thioacetamide tablets are assayed (destructively) to determine the activity by LSC

Neutron-Activated Thioacetamide Discs Problem 2: How to determine the efficiency of the liquid scintillation counter for the 32 P (and the contaminants) at high quench Solution: The 32 P is usually absolutely standardised and relative measurements made on the LSC; this time however the activity of the 32 P in the cocktail was assayed directly by the CIEMAT/NIST technique using 3 H as a tracer and thioacetamide as the quenching agent

Neutron-Activated Thioacetamide Discs sample crushed under a fume hood 0.1 g Thioacetamide dispensed to each vial 2 g Ethanol dispensed & allowed to dissolve (~2 hours) 10 ml Ecoscint A dispensed to each vial

Neutron-Activated Thioacetamide Discs 10 ml Ecoscint A dispensed to each of 10 LS vials 0.1 g 3 H standard added to each vial at 10 kbq/g 0-3 g 10 % Thioacetamide in Ethanol dispensed to each vial Vials thoroughly whirlimied before use!

Quench Curve 32 P Thioacetamide in Ethanol 0.995 0.990 Efficiency 32 P 0.985 0.980 0.975 0.970 0.965 20 40 60 80 100 120 140 tsie

Neutron-Activated Thioacetamide Discs Results still in preparation but appears to work as well as the previous technique of using a 32 P standard directly to determine the efficiency Has some benefits particularly as 3 H is not usually contaminated with secondary nuclides Uncertainties on the activity concentration determined by LSC are around 4 % - not bad considering etremely high quench