DIN Timers TD. Options and ordering codes. Specification

Similar documents
Time - timing relays 1 Industrial relays, solid state output, width 22.5 mm

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Non-Contact Safety Systems CMS

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Display counter electromechanical

W 30 Photoelectric proximity switches: Clear signals even with low remission

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards

WT 27 L-2 Laser Photoelectric proximity switches, background suppression -- DC. Dimensional drawing Adjustments possible WT 27L-2F 430

LEDlight 20 W Universal dimmable series

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

Impedance relay and protection assemblies

LEDlight 30 W Universal dimmable series

I Ex d/e Switch- and Control-Equipment I

W250: Compact photoelectric switch series for a broad range of applications

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN

General characteristics, Products

American Zettler AZ742 RELAY Datasheet

TeSys contactors. TeSys D contactors. 690 V on a and c

BETA Protecting Miniature Circuit Breakers

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

74LS195 SN74LS195AD LOW POWER SCHOTTKY

UL 1077 DIN Rail Supplementary Protectors

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

CTC 155 / 350 / 660 Dry-block calibrator

TeSys enclosed starters 2

EX-CONTROL AND DISTRIBUTION SYSTEMS

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Operating Instructions for Digital Manometer. Model: MAN-SD

General Purpose Relays Types K, R, N, and C

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

XM1 Motor Protection Relay. Manual XM1 (Revision B)

90 MCB range Modular circuit breakers for circuit protection

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION

xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters.

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Modular contactors for installation into distribution

RELAYS. Phone: Fax: Web:

W 34: Sensor technology that does justice to demanding requirements

Type Function Output config. Auxiliary Case Page

BMXART0814 analog input module M340-8 inputs - temperature

TeSys circuit-breakers

74F193 Up/Down Binary Counter with Separate Up/Down Clocks

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

System Components. Electric Motors.

No /06e. Technical Manual Multistage-Temperature-/Differential Controller TAR x700

Number of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E

Metallized PPS Capacitors for extreme capacitance stability. 1 min / 23 C B

Zelio Relay - Solid State Relays

W 9 L: Laser photoelectric switches: small, light and reliable

XD1-L Cable Differential Protection Relay

DRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories

LED- NETZTEILE LED-POWER SUPPLIES

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Pressure Display Controller

FL ballasts Electronic dimming. PCA TC ECO Y II, W ECO compact

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1

NTE74HC299 Integrated Circuit TTL High Speed CMOS, 8 Bit Universal Shift Register with 3 State Output

THREE PHASE CAPACITOR For WIND TURBINES

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

Issued August DATA SHEET. 3VT3 MCCB up to 630 A

Double Thyristor Module For Phase Control MT A2

DRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories

NTE74HC109 Integrated Circuit TTL High Speed CMOS, Dual J K Positive Edge Triggered Flip Flop w/set & Reset

3VT4 Molded Case Circuit Breakers up to 1000 A

Product manual. Mylos KNX Shutter actuator 2CSY1104C/S

Series CCR-39S Multi-Throw DC-12 GHz, SP7T & SP8T Latching Coaxial Switch

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

16 Input AC Block I/O Module

Teccor brand Thyristors 1.5 Amp Sensitive SCRs

Samples. Symbol Parameter Test Conditions Value Unit RMS on-state current T C = 40 C 1.5 A I T(AV) Average on-state current T C

Series CCR-39S Multi-Throw DC-12 GHz, SP9T & SP10T Latching Coaxial Switch

PHOENIX CONTACT - 04/2016. Features

Heat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97

5SP and 5SY Supplementary Protection UL 1077

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

INSTRUCTION AND MAINTENANCE MANUAL FOR TECHTROL COUNTER CONTROLLER & TOTALISER (TCCT)

7S SERIES. Relay module with forcibly guided contacts 6 A 7S S /0310 7S

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Direct-operated 2/2-way solenoid valves Type EV210B

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS

Series CCR-39S Multi-Throw DC-12 GHz, SP9T & SP10T Latching Coaxial Switch

Series CCT-58S Multi-Throw DC 18 GHz, SP7T & SP8T Normally Open Coaxial Switch

4N25/ 4N26/ 4N27/ 4N28. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. Features.

4N35/ 4N36/ 4N37. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. Features.

Thermal-Magnetic Circuit Breaker 2210-S2..

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A

Transcription:

DIN imers D 17.5mm or 22.5mm DIN rail mounting Electronic imers Wide coil operation, 24V to 320V AC/DC Multi ime range / Multi function ON-Delay, OFF-Delay, Asymetrical, Star/Delta versions Perfect to fit in Modular Enclosure Protection against over voltage and reverse polarity Self-Extinguishing plastic housing Options and ordering codes D M10 DIN rail mount timers D Multi-function Asymetical 5 function Star/Delta 20-500ms M10 AS SD1 DM10 Operation modes A,B,C,D,E,F,G,H,I,K ND,FD,NFD,Fon, Foff Star Delta ime range 0.1sec - 10 days 0.1sec - 10 days 1-30sec / 20-500ms Accuracy Supply voltage Nominal power consumption Input signal Control contact must be 90% of A1-A2 Contact configuration Power On - contact control 1 C/O contact Power On 1 C/O contact Power On 2 independent C/O contact Control output 10A @ 250VAC / 3A @ 30VDC Life expectancy Electrical 5 10 4 (5 A @ 250 V AC) Mechanical 10 7 operations Allowable ambient Storage -40 to +85 deg C temperature Operating -25 to +70 deg C IP rating erminals IP20 2.5mm 2 Stranded, 4mm 2 Solid or 2x1.5mm 2 Solid Guarantee / Certification 2 years / CE / UL / cul DAS DSD1 30ppm 150-500VAC 24-300V AC/DC, +/-10%, 45-65Hz 45-65 Hz 24-320VDC max 1W ; 24VAC 2.5VA, 48VAC 4.46VA ; 110VAC 1.76 VA ; 220VAC 2.53 VA Y Y Dimers 03/17

DIN imers DM10 Multi-function time delay Multi-time range Compact design Universal voltage input 24~300V AC/DC Single module size Adjustable values / ime Range Multiplier DM10 1 second 10 second 100 second 1 minute 10 minute 1 hour 10 hour 100 hour 1 day 10 day 0.1-0.2-0.3-0.4-0.5-0.6-0.7-0.8-0.9-1 Indication Lights Legend LED State Description On/t Relay output M1, M2 ON OFF ON OFF Power ON Power OFF Output relay energised Output relay de-energised M1, M2 are used to indicate which function is currently used, see charts page 3 for more details ime Settings ime range selector switch selects full scale time range. he t multiplier selector switch provides fine adjustment of time value, t, within the full scale time range. Selector switch positions are latched upon startup to avoid accidental changes during operation. herefore changing selector switch positions have no effect when the device is operational. he below example shows how to set a t value. Power Input 24..300V AC/DC Relay ime range t multiplier In the above figure: t=10h x 0.5 = 5 hour Note: All the pot values are digitilised. Cannot be set to mid values. Dimers 03/17

DIN imer DM10 continued Mode functions A On Delay On application of supply voltage to terminals U1 and U2 (M2 LED flashing) the set time period t starts to run. On completion of time t, the output Relay energises. Power off reset B Off Delay On application of supply voltage to terminals U1 and U2 (M1 LED flashing) the output Relay is energized and the time period t starts to run. On completion of time t, the output Relay de-energises. Power off reset C On Delay with Control Signal Supply to the unit s terminals U1 and U2 must be continuous (M1 LED On and M2 LED flashing). he output Relay is initially de-energized. Connection of U1 to, triggers the timer and the output Relay is energised after the set time t has elapsed. he Relay remains energized as long as there is a contact connection between U1 and, opening the contact resets and de-energises the output Relay. D Off Delay with Control Signal Supply to the unit s terminals U1 and U2 must be continuous (M2 LED On and M1 LED flashing). Connection of U1 to energizes the output Relay, then on opening the U1- connection the set time period t starts running, when elapsed the output Relay is de-energized. Reconnect of U1 to restarts the time delay and the output Relay will remain energized if the time period has not elapsed. E Rising edge triggered Off Delay Supply to the unit s terminals U1 and U2 must be continuous (energizes asynchronous flashing of M1 and M2 LEDs). On closure of contact between U1 and the output Relay energizes and starts the set timing period t, after t has elapsed the output Relay is de-energized. Changes to the input will be ignored during the timing period t. F Falling edge triggered Off Delay Supply to the unit s terminals U1 and U2 must be continuous (synchronous flashing of M1 and M2 LEDs). On closure and opening of the connection between U1 and the output Relay energizes and the set timing period t starts after this has elapsed the output Relay will de-energize. Changes to the input will be ignored during the timing period t. G Off Flasher On application of supply voltage to U1 and U2 (synchronous flashing of M1 and M2 LEDs) starts the set timing period t with the output Relay initially de-energized, it is energised after the set time t has elapsed then de-energized for time period t. he process repeats, until supply is removed. H On and Off Delay with Control Input Supply to the unit s terminals U1 and U2 must be continuous (asynchronous flashing of M1 and M2 LEDs). On closure of a connection between U1 and the set timing period t starts, when elapsed the output Relay energizes, after which on opening of this connection the timing period t starts again and output Relay is deenergized after the set time t has elapsed. I Adjustable Pulse Output with Control Input Supply to the unit s terminals U1 and U2 must be continuous (M1 LED flashing slowly). Connection of U1 to triggers the timer and energizes the output Relay, changes to the input will be ignored during the time period t. he Relay is then de-energized after the set time t has elapsed. K On Delay With memory Supply to the unit s terminals U1 and U2 must be continuous (M2 LED flashing slowly). With no connection between U1 and on application of the supply output Relay will energize after time period t. If there is a connection made between U1 and during the time period t the count is delayed until such a time that this connection is opened, and then the count continues to relay energising. Once the set time t has elapsed making and breaking the connection between U1 and restarts the process. Dimers 03/17

DAS Mode functions Indication Lights Legend LED On/t State Description ime Settings Relay Output M1, M2 Adjustable values / ime Range Multiplier DAS 1 second 10 second 100 second 1 minute 10 minute 1 hour 10 hour 100 hour 1 day 10 day 0.1-0.2-0.3-0.4-0.5-0.6-0.7-0.8-0.9-1 24-300V DC 24-300V AC Dimers 03/17

DSD1 Mode Functions DS1 star-delta starter is used for take-off starting method used in electrical motors. When energy applied from U1 and U2 terminals, star contacts will be energised until the end of the adjustable t time. Later, at the end of the adjusted wait time t, delta contacts will be energised until the device powered off. IMO DSD1 AC 150-500V Dimers 03/17