FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

Similar documents
FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

Apply Force to Your LC Methods

Fast, Rugged Raptor Columns with Time-Tested Selectivity

Ahead of the Curve for Large, Multiclass Lists by Mass Spec

Definitive EtG/EtS LC-MS/MS Analysis:

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

LC Technical Information

penta-hilic UHPLC COLUMNS

BGB Flash Cartridges. Ultra-pure silica-based material. High-performance spherical 30 µm C18, CN, Diol & HILIC. Pressure up to 27 bar (400 psi)

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

penta-hilic UHPLC COLUMNS

Part 2. Overview of HPLC Media

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Your Reversed Phase Method

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Alltech Alltima HP Introduction

1.7 m Fortis UHPLC Columns

1.7µm Fortis UHPLC Columns

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Acclaim Mixed-Mode WCX-1

LIQUID CHROMATOGRAPHY

LC and LC/MS Column Selection Flow Chart

for Acclaim Mixed-Mode HILIC-1 Column

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

Next Generation of Phenyl Columns. Chromatography Products.

Successfully Scaling and Transferring HPLC and UPLC Methods

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

for Acclaim Mixed-Mode WCX-1

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases

Changing the way you think about HPLC

Multi-mode Separations Using Zirconiabased Stationary Phases

Reversed Phase Solvents

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Acclaim Mixed-Mode WAX-1 Columns

Bringing uhplc Performance to the Separation of Peptides

How proteins separate on reverse-phase HPLC

Alternatives to Sub-2 µm UHPLC Columns

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

+ butanal + 2-picolineborane. + acetic acid. + butanal + 2-picolineborane. + acetic acid

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Too Polar for Reversed Phase What Do You Do?

Epic Aromatic Selectivity

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Small Molecule Selectivity Sampler

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Method Development Kits

HPLC & LC-MS. Techniques to Improve Speed, Resolution and Sensitivity without Investing in Capital Equipment

Technical Guide Thermo Scientific Syncronis HPLC Columns

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Trends in Method Development for HPLC and UHPLC... the movement toward using solid-core particles

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

Packings for HPLC. Packings for HPLC

A Look at Agilent HPLC Columns Choices

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

New Product Update. HPLC Columns

C18 Column. Care & Use Sheet

Kromasil Eternity Designed for long life

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

It s hot! ZIC -chilic

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

InertSustainSwift C8

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

3µm Fortis C18. Fortis 2.1µm. Increased Efficiency. Scalability and Sensitivity

An Introduction to Liquid Chromatography

LC Column Troubleshooting. Do you have an equivalent column for my LC column?

UPLC Method Development and Validation

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

Kromasil Eternity Designed for long life. For use in HPLC and UHPLC

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Routine MS Detection for USP Chromatographic Methods

Advantages and Applications of Revolutionary Superficially Porous Particle Columns in Liquid Chromatography

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

Analyze Nucleotides, Nucleosides, Purine, and Pyrimidine Bases Simultaneously with the Ultra IBD Column

New Applications of Zirconia Based Stationary Phases

[ CARE AND USE MANUAL ]

The Analysis of Organic Acids in Foods and Beverages Using Reversed Phase HPLC

Do you need trouble-free speed? The NEW Chromolith HR

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

Analysis - HPLC A.136. Primesep 5 µm columns B.136

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Fluophase and Fluofix Columns

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

Strategies for the Flash Purification of Highly Polar Compounds

Transcription:

Get the Power of HILIC and RP Modes in One LC Column Selectivity Accelerated Stationary Phase: luorophenyl CH 3 Si CH 3 O Pure Chromatography www.bgb-shop.com/raptor

The Raptor luorophenyl Column With Raptor LC columns, Restek chemists became the first to combine the speed of.7 and 5 μm superficially porous particles (also known as SPP or core-shell particles) with the resolution of highly selective USLC technology, improving separations and speeding up analysis times with standard HPLC instruments. Raptor then evolved to bring that same improved speed, efficiency, and selectivity to UHPLC analyses by offering.8 μm particle columns. Learn more about Raptor LC columns at www.bgb-shop.com/raptor With the addition of Raptor luorophenyl columns, Restek further expanded the speed and reliability of Raptor column technology into the HILIC realm. Restek s Raptor luorophenyl phase offers chromatographers the ability to run in reversed-phase or HILIC mode for a variety of compounds. The Restek Raptor luorophenyl column is also amenable to LC-MS because it is extremely reliable and efficient with acidic mobile phases. Switch to a Raptor luorophenyl LC column for reliable performance in both reversed-phase and HILIC modes. Column Description: CH 3 Si CH 3 O Stationary Phase Category: Pentafluorophenyl propyl (L43) Ligand Type: luorophenyl Particle:.8 μm,.7 μm, or 5 μm superficially porous silica (SPP or core-shell ) Pore Size: 90 Å Surface Area: 5 m /g (.8 μm), 30 m /g (.7 μm), or 00 m /g (5 μm Recommended Usage: ph Range:.0 8.0 Maximum Temperature: 80 C Maximum Pressure:,034 bar/5,000 psi* (.8 μm), 600 bar/8,700 psi (.7 μm); 400 bar/5,800 psi (5 μm) * or maximum lifetime, recommended maximum pressure for.8 μm particles is 830 bar/,000 psi. Properties: Capable of both reversed-phase and HILIC separations. Ideal for increasing sensitivity and selectivity in LC-MS analyses. Offers increased retention for charged bases. Switch to a Raptor luorophenyl LC column when: You observe limited retention and selectivity on a C8 for basic compounds. You need increased retention of hydrophilic compounds. Column Interaction Profile: Solute Retention Profile: Hydrophobic Dispersion H-Bonding Dipolar Acidic Polarizability Cation Exchange Defining Solute Interaction: Cation exchange Complementary Solute Interactions: Polarizability Dispersion Basic 0 4 6 8 0 Target Analyte Structures: Nitrogen-containing Target Analyte unctionalities: Protonated amines Quaternary ammonium compounds Positively charged moieties Lewis bases www.bgb-shop.com/raptor

Raptor luorophenyl Columns: Rugged, Check Reproducible, Double Check. Of course, Raptor luorophenyl columns are rugged; that is to be expected. And, they are exceptionally reproducible as well. Reproducibility can be an issue for fluorinated phenyl phases, which is why we engineered all our columns for dependable performance. Lot to lot, column to column, and injection to injection, every Raptor luorophenyl column gives a consistent performance that you can count on: consider it done. igure : Raptor luorophenyl columns maintain efficiency in any dimension or particle size even at their maximum recommended operating pressures so you can run at high linear velocities with confidence. 0.0% 00.0% 90.0% % Efficiency vs. # of Injections at Maximum Pressure Raptor luorophenyl.7 µm.7 at µm 600 bar 30x.mm 50x.mm 00x.mm 50x.mm 30x3.0mm 80.0% 50x3.0mm 00x3.0mm 70.0% 50x3.0mm 30x4.6mm 60.0% 50x4.6mm 00x4.6mm 50.0% 0 00 400 600 800 000 50x4.6mm igure : Strict quality control ensures Raptor luorophenyl columns are exceptionally reproducible, so you get predictable performance from every column. Reliable, reproducible fluorophenyl column performance. igure 3: rom start to finish, Raptor luorophenyl columns provide accurate, reproducible results. Peaks tr (min) Precursor Ion Product Ion. 4-Methylimidazole (4-MEI).9 83 56 Peaks tr (min) Precursor Ion Product Ion Product Ion. Baccatin III 0.97 587.0 405. 05.0. Docetaxel.5 808. 57.3 6. 3. Paclitaxel.33 854. 569.3 86. 3 Lot Injection Injection 500 Lot Lot 3 Lot 4 Lot 5 Lot 6 0. 0. 0.3 0.4 0.5 0.6 0.7 0.8 0.9.0...3.4.5.6.7.8.9.0 LC_BA035 Column: Raptor luorophenyl (cat.# 93955E); Dimensions: 50 mm x 3 mm ID, Particle Size: 5 µm; Temp.: 35 C; Sample: Diluent: Water; Conc.: 00 ng/ml; Inj. Vol.: 5 µl; Mobile Phase: A: 0.% ormic acid in water; B: 0.% ormic acid in acetonitrile; Gradient (%B): 0.00 min (5% B),.00 (95% B),.0 (5% B), 3.50 (5% B); low: 0.8 ml/min; Detector: MS/MS; Ion Mode: ESI+; Mode: MRM; Instrument: UHPLC. 0.90 0.95.00.05.0.5.0.5.30.35.40.45 LC_056 Column: Raptor luorophenyl (cat.# 939A5); Dimensions: 50 mm x. mm ID, Particle Size:.7 µm; Temp.: 35 C; Sample: Diluent: Acetonitrile; Conc.: 00 ng/ml; Inj. Vol.: 5 µl; Mobile Phase: A: 0.% ormic acid in water; B: 0.% ormic acid in acetonitrile; Gradient (%B): 0.00 min (95% B),.00 (30% B),.0 (95% B), 3.50 (95% B); low: 0.6 ml/min; Detector: MS/MS; Ion Mode: ESI+; Mode: MRM; Instrument: UHPLC. www.bgb-shop.com/raptor 3

More Separating Power than a C8 C8 columns work well for many compounds, but they just don t work for everything. Raptor luorophenyl columns can provide greater selectivity and retention for analytes that are not easily separated by C8 phase chemistry. or example, interest in vitamin D status is on the rise in clinical diagnostics, but accurate analysis is only possible if the epimeric forms of both vitamin D and D3 5-hydroxy metabolites can be distinguished. Typical reversed-phase C8 columns cannot separate these isobaric epimers, which differ in bioactivity, but the new Raptor luorophenyl column provides adequate chromatographic resolution so accurate results are generated and the proper diagnosis can be made. igure 4: Reversed-phase C8 columns do not have the right selectivity or retention mechanism to separate the epimers of vitamin D and D3 5-hydroxy metabolites. Epimers do not separate on a C8, even in a 4-minute analysis time.,, Conc. Peaks MRM tr (ng/ml). 5-Hydroxyvitamin D3 40.5/383.4 9.36 50. 3-Epi-5-hydroxyvitamin D3 40.5/383.4 9.36 5 Conc. Peaks MRM tr (ng/ml). 5-Hydroxyvitamin D 43.5/355.5 0.38 50. 3-Epi-5-hydroxyvitamin D 43.5/355.5 0.38 5.0.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 0.0.0.0 3.0 LC_C0649.0.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 0.0.0.0 3.0 Column: Raptor ARC-8 (cat.# 934A); Dimensions: 00 mm x. mm ID, Particle Size:.7 µm; Temp.: 30 C; Sample: Diluent: Water:methanol (50:50); Conc.: 5-50 ng/ml; Inj. Vol.: 5 µl; Mobile Phase: A: 0.% ormic acid in water; B: Methanol; Gradient (%B): 0.00 min (75% B), 4.00 (80% B),.00 (80% B),.0 (75% B); 4.00 (75% B); low: 0.5 ml/min; Detector: MS/MS; Ion Mode: ESI+; Mode: MRM; Instrument: HPLC. igure 5: Raptor luorophenyl columns have the selectivity and retention you need to quickly and easily separate compounds that coelute on a C8, such as the epimeric forms of vitamin D and D3 5-hydroxy metabolites. Raptor luorophenyl columns easily separate compounds that coelute on a C8. Raptor reproducibility lets you develop assays with confidence. Conc. Peaks MRM tr (ng/ml). 5-Hydroxyvitamin D3 40.5/383.4 3.59 50. 3-Epi-5-hydroxyvitamin D3 40.5/383.4 3.78 5 Lot 0.5.0.5.0.5 3.0 3.5 4.0 4.5 5.0 Lot Conc. Peaks MRM tr (ng/ml). 5-Hydroxyvitamin D 43.5/355.5 3.73 50. 3-Epi-5-hydroxyvitamin D 43.5/355.5 3.9 5 Lot 3 0.5.0.5.0.5 3.0 3.5 4.0 4.5 5.0 LC_C0644 0.5.0.5.0.5 3.0 3.5 4.0 4.5 5.0 5.5 LC_C0646 Column: Raptor luorophenyl (cat.# 939AE); Dimensions: 00 mm x 3 mm ID, Particle Size:.7 µm; Temp.: 30 C; Sample: Diluent: Water:methanol (50:50); Conc.: 5-50 ng/ml; Inj. Vol.: 5 µl; Mobile Phase: A: 0.% ormic acid in water; B: Methanol; Gradient (%B): 0.00 min (75% B), 4.00 (85% B), 4.0 (00% B), 5.00 (00% B), 5.0 (75% B), 7.00 (75% B); low: 0.6 ml/min; Detector: MS/MS; Ion Mode: ESI+; Mode: MRM; Instrument: HPLC. 4 www.bgb-shop.com/raptor

Get the Power of HILIC and RP Modes in One LC Column HILIC chromatography is becoming the go-to solution for compounds that are difficult to retain on a C8. The Raptor luorophenyl column gives chromatographers the flexibility to evaluate compound retention in both reversed-phase and HILIC modes. The analysis of 4-methylimidazole (4-MEI), which is a byproduct of caramel coloring in foods and beverages, can be problematic by reversed-phase chromatography due to very limited retention. However, 4-MEI is well retained on a Raptor luorophenyl column and can easily be analyzed using HILIC mode and simple LC and LC-MS/MS compatible mobile phases. igure 6: Sometimes, adequate retention cannot be obtained with a C8. The Raptor luorophenyl column performs dependably in either HILIC or RP mode, so you can use the mode that is best for your analytes. Raptor luorophenyl columns give you the flexibility to work in both reversed-phase and HILIC modes. Peaks tr (min) Precursor Ion Product Ion. 4-Methylimidazole (4-MEI).9 83 56 HILIC retention of 4-MEI Lot Lot Lot 3 0.90 0.95.00.05.0.5.0.5.30.35.40.45.50 LC_0560 0.00 0.0 0.40 0.60 0.80.00.0.40.60.80.00.0.40.60.80 3.00 3.0 3.40 LC_0559 Column: Raptor luorophenyl (cat.# 939A5); Dimensions: 50 mm x. mm ID; Particle Size:.7 µm; Temp.: 35 C; Sample: Diluent: Acetonitrile; Conc.: 00 ng/ml; Inj. Vol.: 5 µl; Mobile Phase: A: 0.% ormic acid in water; B: 0.% ormic acid in acetonitrile; Gradient (%B): 0.00 min (95% B),.00 (30% B),.0 (95% B), 3.50 (95% B); low: 0.6 ml/min; Detector: MS/MS; Ion Mode: ESI+; Mode: MRM; Instrument: UHPLC. www.bgb-shop.com/raptor 5

ast, Accurate Analysis of Basic Compounds Taxane drugs such as paclitaxel, docetaxel, and their precursor baccatin III are early chemotherapy treatment options. Accurate analysis is critical because these drugs are used for many types of metastatic cancers. As shown here, the selectivity of the Raptor luorophenyl column provides excellent retention and resolution of these structurally similar compounds. Reliable results for these basic compounds can be obtained in fast analysis times using LC-MS/MS friendly solvents. igure 7: Raptor luorophenyl columns allow taxane drugs and other basic compounds to be separated quickly and effectively. Raptor luorophenyl columns have the retention needed for fast, accurate analysis of basic compounds. Peaks tr (min) Precursor Ion Product Ion Product Ion. Baccatin III 0.97 587.0 405. 05.0. Docetaxel.5 808. 57.3 6. 3. Paclitaxel.33 854. 569.3 86. 3 0.0 0. 0. 0.3 0.4 0.5 0.6 0.7 0.8 0.9.0...3.4.5.6.7.8.9.0 LC_BA035 Column: Raptor luorophenyl (cat.# 93955E); Dimensions: 50 mm x 3 mm ID, Particle Size: 5 µm; Temp.: 35 C; Sample: Diluent: Water; Conc.: 00 ng/ml; Inj. Vol.: 5 µl; Mobile Phase: A: 0.% ormic acid in water; B: 0.% ormic acid in acetonitrile; Gradient (%B): 0.00 (5% B),.00 (95% B),.0 (5% B), 3.50 (5% B); low: 0.8 ml/min; Detector: MS/MS; Ion Mode: ESI+; Mode: MRM; Instrument: UHPLC. 6 www.bgb-shop.com/raptor

Exceptional Selectivity for Clinical Analyses The analysis of normetanephrine and metanephrine provides another example of the power of Raptor luorophenyl columns for analyzing basic compounds. Accurately determining these metabolites of epinephrine/norepinephrine in plasma or urine is one of the best diagnostic tests for neuroendocrine tumors (pheochromocytomas). Normetanephrine and metanephrine are difficult to retain by typical C8 reversed-phase chromatography; however, the Raptor luorophenyl column provides a simple, fast chromatographic solution to this challenging assay. The Raptor luorophenyl column s unique combination of aromatic retention and cation exchange mechanisms are not provided by a C8 column and result in reliable, high-quality separations. igure 8: Rapid analysis of metanephrine and normetanephrine on a Raptor luorophenyl column. Peaks tr (min) Precursor Ion Product Ion Product Ion. Normetanephrine.5 66.. 34.0. Metanephrine.5 80. 65. 48.3 Lot Lot Lot 3 0.0 0.40 0.60 0.80.00.0.40.60.80.00 LC_C0643 0.0 0.40 0.60 0.80.00.0.40.60.80 LC_C064 Column: Raptor luorophenyl (cat.# 939A); Dimensions: 00 mm x. mm ID; Particle Size:.7 µm; Temp.: 30 C; Sample: Diluent: Water; Conc.: 0 ng/ml; Inj. Vol.: 5 µl; Mobile Phase: A: 0.% ormic acid in water; B: Methanol; Gradient (%B): 0.00 min (% B),.00 (40% B),.0 (% B), 6.00 (% B); low: 0.4 ml/min; Detector: MS/MS; Ion Mode: ESI+; Mode: MRM; Instrument: UHPLC. www.bgb-shop.com/raptor 7

Dependable Raptor luorophenyl Columns Give You the lexibility to Use Both HILIC and RP Modes Raptor luorophenyl LC Columns (USP L43) Raptor EXP Guard Cartridges for.7 and 5 µm Raptor Columns Hand-Tight itting No Tools Needed! Unidirectional Raptor EXP Guard Column Cartridge Holder Body Auto-adjusting Titanium Hybrid errule ZDV Connections!. mm cat.# EXP Reusable ittings for HPLC & UHPLC for 0-3 fittings and /6 tubing Effortlessly achieve 8,700+ psi HPLC seals by hand! (Wrench tighten to 0,000+ psi.) Hybrid titanium/peek seal can be installed repeatedly without compromising your seal. 3.0 mm cat.# 4.6 mm cat.# Length.8 µm Columns 30 mm 9393 50 mm 9395 9395E 00 mm 939 939E 50 mm 9396.7 µm Columns 30 mm 939A3 939A3E 939A35 50 mm 939A5 939A5E 939A55 00 mm 939A 939AE 939A5 50 mm 939A6 939A6E 939A65 5 µm Columns 30 mm 93953E 50 mm 93955 93955E 939555 00 mm 9395 9395E 93955 50 mm 93956 93956E 939565 50 mm 939575 Description qty. cat.# EXP Hand-Tight itting (Nut w/errule) ea. 5937 EXP Hand-Tight itting (Nut w/errule) 0-pk. 5938 EXP Hand-Tight Nut (w/o errule) ea. 5939 Hybrid errule U.S. Patent No. 80854, Optimize Technologies. EXP Holders U.S. Patent No. 869690, Optimize Technologies. EXP wrench U.S. Patent No. D766055, Optimize Technologies. Other U.S. and oreign Patents Pending. The Opti- prefix is a registered trademark of Optimize Technologies, Inc. Protect your investment and extend the life of our already-rugged LC columns and change guard column cartridges by hand without breaking fluid connections no tools needed! EXP Direct Connect Holder Description qty. cat.# EXP Direct Connect Holder for EXP Guard Cartridges (includes hex-head fitting & ferrules) ea. 5808 Maximum holder pressure: 0,000 psi (,400 bar) Raptor EXP Guard Column Cartridges 5 x. mm 5 x 3.0 mm 5 x 4.6 mm Description Particle Size qty. cat.# cat.# cat.# Raptor luorophenyl EXP Guard Column Cartridges.7 µm 3-pk. 939A05 939A053 939A050 Raptor luorophenyl EXP Guard Column Cartridges 5 µm 3-pk. 939505 9395053 9395050 Maximum cartridge pressure: 600 bar/8,700 psi (.7 µm) or 400 bar/5,800 psi (5 µm). Raptor SPP LC columns combine the speed of SPP with the resolution of USLC technology. Learn more at www.restek.com/raptor UltraShield UHPLC PreColumn ilter for.8 µm Raptor Columns Description ilter Porosity qty. cat.# UltraShield UHPLC PreColumn ilter 0. µm frit ea. 5809 5-pk. 580 0-pk. 58 Experience Selectivity Accelerated. Order the Raptor luorophenyl today at www.bgb-shop.com/raptor DR-BGB-804 www.bgb-shop.com Switzerland: BGB Analytik AG Rohrmattstrasse 4 446 Böckten Phone +4 6 99 00 46 ax +4 6 99 00 5 sales@bgb-analytik.com BGB Analytik SA Route de Pré-Bois 0 5 Genève 5 Phone +4 788 49 43 ax +4 788 49 45 sales.fr@bgb-analytik.com Austria: BGB Analytik Vertrieb GmbH Josefstrasse 9a 7968 Rheinfelden Phone +49 763 7730 ax +49 763 77399 sales.de@bgb-analytik.com BGB is authorized Restek distributor for Austria and Switzerland.