Tension Members. ENCE 455 Design of Steel Structures. II. Tension Members. Introduction. Introduction (cont.)

Similar documents
Presented by: Civil Engineering Academy

CONNECTION DESIGN. Connections must be designed at the strength limit state

Job No. Sheet 1 of 6 Rev B. Made by IR Date Oct Checked by FH/NB Date Oct Revised by MEB Date April 2006

FHWA Bridge Design Guidance No. 1 Revision Date: July 21, Load Rating Evaluation of Gusset Plates in Truss Bridges

ENCE 455 Design of Steel Structures. III. Compression Members

Compression Members. ENCE 455 Design of Steel Structures. III. Compression Members. Introduction. Compression Members (cont.)

CHAPTER 2 LITERATURE REVIEW

Timber and Steel Design. Lecture 11. Bolted Connections

SHEAR LAG IN SLOTTED-END HSS WELDED CONNECTIONS

MODULE F: SIMPLE CONNECTIONS

twenty steel construction: columns & tension members ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS FALL 2013 lecture

BLOCK SHEAR BEHAVIOUR OF BOLTED GUSSET PLATES

CH. 5 TRUSSES BASIC PRINCIPLES TRUSS ANALYSIS. Typical depth-to-span ratios range from 1:10 to 1:20. First: determine loads in various members

MECE 3321 MECHANICS OF SOLIDS CHAPTER 1

BLOCK SHEAR CONNECTION DESIGN CHECKS

Chapter Objectives. Design a beam to resist both bendingand shear loads

Example 4: Design of a Rigid Column Bracket (Bolted)

D e s i g n o f R i v e t e d J o i n t s, C o t t e r & K n u c k l e J o i n t s

An investigation of the block shear strength of coped beams with a welded. clip angles connection Part I: Experimental study

Karbala University College of Engineering Department of Civil Eng. Lecturer: Dr. Jawad T. Abodi

ES230 STRENGTH OF MATERIALS

Engineering Mechanics Department of Mechanical Engineering Dr. G. Saravana Kumar Indian Institute of Technology, Guwahati

Failure in Flexure. Introduction to Steel Design, Tensile Steel Members Modes of Failure & Effective Areas

Application nr. 3 (Ultimate Limit State) Resistance of member cross-section

BLOCK SHEAR BEHAVIOUR OF COPED STEEL BEAMS

PLATE GIRDERS II. Load. Web plate Welds A Longitudinal elevation. Fig. 1 A typical Plate Girder

ARC 341 Structural Analysis II. Lecture 10: MM1.3 MM1.13

Theory of structure I 2006/2013. Chapter one DETERMINACY & INDETERMINACY OF STRUCTURES

APRIL Conquering the FE & PE exams Formulas, Examples & Applications. Topics covered in this month s column:

[5] Stress and Strain

MECHANICS OF MATERIALS

CHAPTER 5 Statically Determinate Plane Trusses

General Comparison between AISC LRFD and ASD

CHAPTER 5 Statically Determinate Plane Trusses TYPES OF ROOF TRUSS

SERVICEABILITY OF BEAMS AND ONE-WAY SLABS

Samantha Ramirez, MSE. Stress. The intensity of the internal force acting on a specific plane (area) passing through a point. F 2

STEEL. General Information

Application nr. 7 (Connections) Strength of bolted connections to EN (Eurocode 3, Part 1.8)

RESILIENT INFRASTRUCTURE June 1 4, 2016

SAULTCOLLEGE of AppliedArtsand Technology SaultSte. Marie COURSEOUTLINE

Determine the resultant internal loadings acting on the cross section at C of the beam shown in Fig. 1 4a.

Design of Shear Tab Connections for Gravity and Seismic Loads

Active Shear Planes in Block Shear Failure of Bolted Connections

Solid Mechanics Chapter 1: Tension, Compression and Shear

Abstract Block shear is a mode of failure in which a steel member fails in tension along one plane and shear on a

Unfinished Bolt ordinary, common, rough or black bolts High strength Bolt friction type bolts

ENG1001 Engineering Design 1

Steel connections. Connection name : MEP_BCF_W=14.29[mm]_W=6.35[mm]_tp=63.5[mm]_N=0_N=2_N=0_N=1_W=14.29[mm]_W=14.29[mm]_W=14.29[ mm] Connection ID : 1

Chapter 6: Structural Analysis

D : SOLID MECHANICS. Q. 1 Q. 9 carry one mark each. Q.1 Find the force (in kn) in the member BH of the truss shown.

Accordingly, the nominal section strength [resistance] for initiation of yielding is calculated by using Equation C-C3.1.

MECHANICS OF MATERIALS. Prepared by Engr. John Paul Timola

Final Exam - Spring

Steel Design. Notation:

twenty steel construction: columns & tension members ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS FALL 2018 lecture

STRESS. Bar. ! Stress. ! Average Normal Stress in an Axially Loaded. ! Average Shear Stress. ! Allowable Stress. ! Design of Simple Connections

Design of Steel Structures Prof. Damodar Maity Department of Civil Engineering Indian Institute of Technology, Guwahati

Part 1 is to be completed without notes, beam tables or a calculator. DO NOT turn Part 2 over until you have completed and turned in Part 1.

JointsForTekla Ver January

Project data Project name Project number Author Description Date 26/04/2017 Design code AISC dome anchor. Material.

Chapter 7: Bending and Shear in Simple Beams

Fundamentals of Structural Design Part of Steel Structures

Mechanics of Materials Primer

Jeff Brown Hope College, Department of Engineering, 27 Graves Pl., Holland, Michigan, USA UNESCO EOLSS

MODULE C: COMPRESSION MEMBERS

BRACING MEMBERS SUMMARY. OBJECTIVES. REFERENCES.

7 STATICALLY DETERMINATE PLANE TRUSSES

the Steel Construction Manual

Special edition paper

林保均 / Pao-Chun Lin. National Center for Research on Earthquake Engineering M.S. / Civil Engineering Department, National Taiwan University

db = 23.7 in B C D 96 k bf = 8.97 in tf = in k = 1.09 in 13 Fy = 50 ksi Fu = 65 ksi Member A-B, Interior column: A E

Design of Steel Structures Dr. Damodar Maity Department of Civil Engineering Indian Institute of Technology, Guwahati

MECE 3321 MECHANICS OF SOLIDS CHAPTER 3

ME Statics. Structures. Chapter 4

FLEXIBILITY METHOD FOR INDETERMINATE FRAMES

WRAP-AROUND GUSSET PLATES

PDDC 1 st Semester Civil Engineering Department Assignments of Mechanics of Solids [ ] Introduction, Fundamentals of Statics

2. Rigid bar ABC supports a weight of W = 50 kn. Bar ABC is pinned at A and supported at B by rod (1). What is the axial force in rod (1)?

ME 243. Mechanics of Solids

Experimental investigation on monotonic performance of steel curved knee braces for weld-free beam-to-column connections

ME411 Engineering Measurement & Instrumentation. Winter 2017 Lecture 9

TABLE OF CONTENTS SECTION TITLE PAGE 2 PRINCIPLES OF SEISMIC ISOLATION OF BRIDGES 3

CHAPTER 8 SCREWS, FASTENERS, NONPERMANENT JOINTS

Supplement: Statically Indeterminate Trusses and Frames

Chapter 9: Column Analysis and Design

10012 Creviston DR NW Gig Harbor, WA fax

Karbala University College of Engineering Department of Civil Eng. Lecturer: Dr. Jawad T. Abodi

Duan, L. and Reno, M. Performance-Based Seismic Design Criteria For Bridges Structural Engineering Handbook Ed. Chen Wai-Fah Boca Raton: CRC Press

Steel Design. Notation: a A A b A e

Design of Beams (Unit - 8)

CALCULATION MODE FOR ALUHD23/SH18 Traction and shear aluminium plate for Alufoot R system

TORSION INCLUDING WARPING OF OPEN SECTIONS (I, C, Z, T AND L SHAPES)

ME 354, MECHANICS OF MATERIALS LABORATORY COMPRESSION AND BUCKLING

QUESTION BANK DEPARTMENT: CIVIL SEMESTER: III SUBJECT CODE: CE2201 SUBJECT NAME: MECHANICS OF SOLIDS UNIT 1- STRESS AND STRAIN PART A

NORMAL STRESS. The simplest form of stress is normal stress/direct stress, which is the stress perpendicular to the surface on which it acts.

A CONNECTION ELEMENT FOR MODELLING END-PLATE CONNECTIONS IN FIRE

Buckling-Restrained Braced Frame Connection Design and Testing

Shared on QualifyGate.com

The University of Melbourne Engineering Mechanics

Module 6. Approximate Methods for Indeterminate Structural Analysis. Version 2 CE IIT, Kharagpur

Transcription:

ENCE 455 Design of Steel Structures II. Tension Members C. C. Fu, Ph.D., P.E. Civil and Environmental Engineering Department University of Maryland Tension Members Following subjects are covered: Introduction Design strength Net area Staggered fasteners Block shear Design of tension members Threaded rods, pin-connected members Reading: Chapters 3 of Salmon & Johnson AISC Steel Manual Specifications (Part 16) Chapters B (Design Requirements), D (Tension Members), and J (Connections) 2 Introduction Tension members are structural elements that are subjected to axial tensile forces. Examples include: Members in trusses Cables in cable-stayed and suspension bridges Bracing in frames to resist lateral forces from blast, wind, and earthquake Forth Bridge Queensferry, Scotland Main sections: 5360 ft. Maximum span: 1710(2), 4 spans total Built: 1890 3 Introduction (cont.) Stresses (f) in axially loaded members are calculated using the equation f P A where P is the load and A is the crosssectional area normal to the load. Design of this component involves calculations for Tension member (gross area) Tension member at connection (net area) Gusset plate at connection (net area) Gusset plate at support 4

Design Strength A tension member can fail by Excessive deformation (yielding) - Excessive deformation is prevented by limiting stresses on the gross section to less than the yield stress. For yielding on the gross section, the nominal strength is: T n = F y A g and φ t =0.90 (3.2.1) Fracture - Fracture is avoided by limiting stresses on the net section to less than the ultimate tensile strength. For fracture on the net section, the nominal strength is: T n = F u A e =F u (UA n ) and φ t =0.75 (3.2.2) where A e is the effective net area, A n is the net area and U is the reduction coefficient (an efficient factor) 5 Net Area Net Area - The performance of a tension member is often governed by the response of its connections. The AISC Steel Manual introduces a measure of connection performance known as joint efficiency, which is a function of Material properties (ductility) Fastener spacing Stress concentrations Shear lag (Most important of the four and addressed specifically by the AISC Steel Manual) 6 Net Area (cont.) The AISC Steel Manual introduces the concept of effective net area to account for shear lag effects. For bolted connections: A e =UA n (3.5.1) For welded connections: A e =UA g (3.5.3) where U 1 x 0.9 (3.5.2) L and x is the distance from the plane of the connection to the centroid of the connected member and L is the length of the connection in the direction of the load. (Salmon & Johnson Example 3.5.1 for U) Net Area (cont.)/ x Salmon & Johnson AISC Steel Manual 7 8

Net Area (cont.)/l Net Area (cont.)/u For bolted connections, AISC Table D3.1 gives values for U that can be used in lieu of detailed calculation. 9 10 Net Area (cont.)/u For welded connections, AISC Table D3.1 lists 11 Staggered Fasteners Failure line - When a member has staggered bolt holes, a different approach to finding A e for the fracture limit state is taken. This is because the effective net area is different as the line of fracture changes due to the stagger in the holes. The test for the yielding limit state remains unchanged (the gross area is still the same). For calculation of the effective net area, the Section B2 of the AISC Steel Manual makes use of the product of the plate thickness and the net width. The net width is calculated as 2 s wn wg d 4g 12

Staggered Fasteners (cont.) Staggered Fasteners (cont.) All possible failure patterns should be considered. (Example 3.4.2 for A n ) 13 14 Staggered Fasteners (cont.) Block Shear Block shear is an important consideration in the design of steel connections. Consider the figure below that shows the connection of a single-angle tension member. The block is shown shaded. Figure 3.8.2 Load distribution in plate A (Example 3.8.1) 15 16

Block Shear (cont.) In this example, the block will fail in shear along ab and tension on bc. The AISC Steel Manual procedure is based on one of the two failure surfaces yielding and the other fracturing. Fracture on the shear surface is accompanied by yielding on the tension surface Fracture on the tension surface is accompanied by yielding on the shear surface Both surfaces contribute to the total resistance. 17 Block Shear (cont.) The nominal strength in tension is F u A nt for fracture and F y A gt for yielding where the second subscript t denotes area on the tension surface ( bc in the figure above). The yield and ultimate stresses in shear are taken as 60% of the values in tension. The AISC Steel Manual considers two failure modes: Shear yield - tension fracture -T n = 0.6F y A gv + F u A nt (3.6.1) Shear fracture - tension yield -T n = 0.6F u A nv + F u A nt (3.6.2) One equation to cover all T n = 0.6F u A nv + U bs F u A nt 0.6F y A gv + U bs F u A nt (AISC J4-5) Because the limit state is fracture, the equation with the larger of the two fracture values controls where φ t =0.75. (Example 3.9.2 for block shear) (U 18 bs =1 for uniform; =0.5 for non-uniform tension stress) The design of a tension member involves selecting a member from the AISC Steel Manual with adequate Gross area Net area Slenderness (L/r 300 to prevent vibration, etc; does not apply to cables.) If the member has a bolted connection, the choice of cross section must account for the area lost to the bolt holes. Because the section size is not known in advance, the default values of U are generally used for preliminary design. 19 (cont.) Detailing of connections is a critical part of structural steel design. Connections to angles are generally problematic if there are two lines of bolts. Consider the Gages for Angle figure shown earlier that provides some guidance on sizing angles and bolts. Gage distance g 1 applies when there is one line of bolts Gage distances g 2 and g 3 apply when there are two lines 20

(cont.)/ Thread Rod Threaded Rod (cont.)/ Thread Rod Threaded Rod - Tension on the effective net area T n = A s F u = 0.75A b F u, where A s is the stress area (threaded portion), A b is the nominal (unthreaded area), and 0.75 is a lower bound (conservative) factor relating A s and A b. See Section J3.6 of the AISC Steel Manual Specification for details. The design strength of a threaded rod is calculated as T n =0.75 T n (Example 3.10.2 for Rod Design) 21 22 (cont.)/ Pinned Connections Pinned connections transmit no moment (ideally) and often utilize components machined to tight tolerances (plus, minus 0.001 ). The figure shows failure modes for pin-connected members and each failure mode must be checked for design. Specifically, the following limit states must be checked. 23 (cont.)/ Pinned Connections The following limit states must be checked. Tension on the effective net area T n = 0.75(2 t b eff F u ) where b eff = 2t + 0.63 b (D5-1) Shear on the effective area T n = 0.75(0.6A sf F u ) = 0.75{0.6[2t (a+ d/2)] F u } (D5-2) Bearing on projected area T n = 0.75(1.8 A pb F y ) = 0.75[1.8 (d t ) F y ] (J8-1) where 1.8 A pb F y is based on a deformation limit state under service loads producing stresses of 90% of yield Tension on the gross section T n = 0.9(A g F y ) (D1-1) 24